Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installation tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Top Launch for Higher Off-axis Electron Cyclotron Current Drive Efficiency

Efficient off-axis current drive is crucial for economic, steady-state tokamak fusion power plants. "Top Launch" electron cyclotron current drive (ECCD) is one promising method for driving strong off-axis current to achieve the desired broad current profile for the Advanced Tokamak regime. New simulations show that by launching the electron cyclotron (EC) waves downwards (or upwards) nearly parallel to the resonance plane with a large toroidal steering, higher current drive efficiency can be obtained at large radii owing to the large Doppler shift, wave-particle interactions on HFS of the plasma, and the long absorption path. Implementations on CFETR and DIII-D are simulated identifying clear benefits and optimal configurations. The design of a prototype test being installed on DIII-D is presented, which will experimentally validate whether top launch ECCD can be an improved efficiency current drive technique for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SpackDev: Multi-Package Development with Spack

High Energy Physics (HEP) software environments often involve ~ hundreds of external packages and libraries, and similar numbers of experiment-specific, science-critical packages—many under continuous development. Managing coherent releases of the external software stack is challenging enough, but managing the highly-collaborative—and distributed—development of a large body of code against such a stack adds even more complexity and room for error. Spack is a popular Python-based package management tool with a specific focus on the needs of High Performance Computing (HPC) systems and system administrators whose strength is orchestrating the discrete download, build, testing, and installation of pre-packaged or tagged third-party software against similarly stable dependencies. As such it is becoming increasingly popular within HEP as that community makes increasing use of HPC facilities, and as efforts to develop future HPC systems utilize Spack to provide scientific software on those platforms. SpackDev is a system to facilitate the simultaneous development of interconnected sets of packages. Intended to handle packages without restriction to one internal build system, SpackDev is integrated with Spack as a command extension in order to leverage features such as dependency calculations and build system configuration, and is generally applicable outside HEP. We describe SpackDev’s features and development over the last two years, initial experience using SpackDev in the context of the LArSoft liquid argon detector toolkit, and work remaining before it can be considered a fully-functional multi-package build system for HEP experiments utilizing Spack.

Green, Chris↗

Status of J-PARC Main Ring

The J-PARC (Japan Proton Accelerator Research Complex) facility is under construction as a joint project of KEK and JAEA. In this paper, we present a construction status of slow cycling main ring synchrotron (MR) of J-PARC. Performance test and installation of accelerator components are now in progress. Beam commissioning is scheduled to start in May 2008.

43 PARTICLE ACCELERATORS↗

First HIBP results on the WEGA Stellarator

The heavy ion beam probe (HIBP) is an established non perturbing diagnostic for measuring the spatial distributions of plasma potential, density, temperature and poloidal magnetic field (axial current) of magnetically confined fusion plasma. These are determined from the change in the primary ion beam parameters (charge, intensity and trajectory) passing through a plasma volume due to collisions with electrons and interactions with the confining magnetic field. A heavy ion beam probe plasma diagnostic system has been installed and tested on the WEGA stellarator in Greifswald, Germany in 2006-2007. The WEGA HIBP operates with a beam of singly charged sodium ions with an energy of up to 60 keV, ion current up to 100 {mu}A, and beam diameter of 5-6 mm in the confined plasma region. Plasma experiments with the HIBP diagnostic system were carried out at a magnetic field strength of B{sub 0} = 0.489 T. In the experiments, an argon plasma was heated with ECRH at 28 GHz. In this work the first plasma potential and total current profile measurements results are presented. This work was supported by STCU P-202 project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aperture Size Effect on Extracted Negative Ion Current Density

This paper discusses experimental results obtained at the 1 MV testbed at CEA Cadarache that appear to show a higher extracted D{sup -} current density from small apertures. Plasma grids with different shapes have been installed and tested. All grids had one single aperture. The tests were done in volume operation and in caesium operation. We tested four grids, two with Oe14 mm, one with Oe11 mm and one with Oe8 mm apertures. No aperture size effect was observed in volume operation. In caesiated operation the extracted current density for the Oe8 mm aperture appears to be significantly higher ({approx}50%) than for the Oe14 mm aperture. Simulations with a 3D Monte Carlo Trajectory Following Code have shown an aperture size effect of about 20%. Finally, as byproducts of the experiments, data on backstreaming positive ions and the temperature of the plasma grid have been obtained.

43 PARTICLE ACCELERATORS↗

The Intense Slow Positron Beam Facility at the NC State University PULSTAR Reactor

An intense slow positron beam is in its early stages of operation at the 1-MW open-pool PULSTAR research reactor at North Carolina State University. The positron beam line is installed in a beam port that has a 30-cmx30-cm cross sectional view of the core. The positrons are created in a tungsten converter/moderator by pair-production using gamma rays produced in the reactor core and by neutron capture reactions in cadmium cladding surrounding the tungsten. Upon moderation, slow ({approx}3 eV) positrons that are emitted from the moderator are electrostatically extracted, focused and magnetically guided until they exit the reactor biological shield with 1-keV energy, approximately 3-cm beam diameter and an intensity exceeding 6x10{sup 8} positrons per second. A magnetic beam switch and transport system has been installed and tested that directs the beam into one of two spectrometers. The spectrometers are designed to implement state-of-the-art PALS and DBS techniques to perform positron and positronium annihilation studies of nanophases in matter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

New printed circuit boards magnetic coils in the vacuum vessel of J-TEXT tokamak for position measurement

Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic discharges. Each coordinate is determined by a pair of variable cross-section Rogowski and saddle coils, which measure the tangential and normal magnetic fields (relative to the coil surface). These coils are suitable for mass production and offer advantages in vacuum compatibility and temperature tolerance that are important for J-TEXT. Position measurements using PCB coils are compared with those from soft x-ray image system and match the position well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial measurements of fast ion loss in KSTAR

A fast ion loss detector (FILD) has been installed and tested in Korea Superconducting Tokamak Advanced Research (KSTAR). KSTAR FILD measures the energy and the pitch-angle of the escaping ions with the striking positions on the scintillator plane. Measurements of the fast ion loss have been performed for the neutral beam heated plasmas. Initial experimental results indicate the prompt losses from neutral beam are dominant and the effects of the resonant magnetic perturbation on the fast ion loss are investigated. In addition, further design change of the detector-head in order to avoid excessive heat load and to detect the fusion products or the fast ions having order of MeV of energy is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design approach for the development of a cryomodule for compact crab cavities for Hi-Lumi LHC

A prototype Superconducting RF (SRF) cryomodule, comprising multiple compact crab cavities is foreseen to realise a local crab crossing scheme for the “Hi-Lumi LHC”, a project launched by CERN to increase the luminosity performance of LHC. A cryomodule with two cavities will be initially installed and tested on the SPS drive accelerator at CERN to evaluate performance with high-intensity proton beams. A series of boundary conditions influence the design of the cryomodule prototype, arising from; the complexity of the cavity design, the requirement for multiple RF couplers, the close proximity to the second LHC beam pipe and the tight space constraints in the SPS and LHC tunnels. As a result, the design of the helium vessel and the cryomodule has become extremely challenging. This paper assesses some of the critical cryogenic and engineering design requirements and describes an optimised cryomodule solution for the evaluation tests on SPS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial beam emission spectroscopy diagnostic system on HL-2A tokamak

A beam emission spectroscopy system is being developed and deployed on the HL-2A tokamak to measure local low wavenumber (k ⊥ ρ i < 1) density fluctuations by measuring the Doppler-shifted emission from a 50 kV deuterium heating neutral beam. High spatial resolution (Δr ≤ 1 cm, Δz ≤ 1.5 cm) measurements are achieved with customized in-vacuum optics. High frequency, high-gain preamplifiers sample the light intensity at a Nyquist frequency of 1 MHz and achieve a high S/N ratio via high optical throughput, low-noise preamplifiers, and high quantum efficiency photodiodes. A first set of 16 detector channels [configured in an 8 (radial) × 2 (poloidal) array] has been installed and tested at HL-2A, covering the radial range r/a = 0.8–1.1. The frequency and wavenumber spectra have been measured under different plasma conditions. Initial measurements have demonstrated the capability of measuring edge plasma density fluctuation spectra and the poloidal flow velocity fields with a high S/N ratio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The multi-spectral imaging diagnostic

The Multi-Spectral Imaging system is a new diagnostic that captures simultaneous spectrally filtered images from a common line of sight while maintaining a large étendue and high throughput. Simultaneously imaging several atomic line intensities may enable numerous measurement techniques. By making a novel modification of a polychromator layout, the MSI sequentially filters and focuses images onto commercial CMOS cameras while exhibiting minimal vignetting and aberrations. A four-wavelength system was initially installed and tested on Alcator C-Mod and subsequently moved to TCV. The images are absolutely calibrated and spatially registered enabling 2D mappings of atomic line ratios and absolute line intensities. The spectral transmission of the optical system was calibrated using an integrating sphere of known radiance. The images are inverted by cross-referencing points on TCV with a computer-aided design (CAD) model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design elements and first data from a new Doppler backscattering system on the MAST-U spherical tokamak

A new Doppler backscattering (DBS) system has been installed and tested on the MAST-U spherical tokamak. It utilizes eight simultaneous fixed frequency probe beams (32.5, 35, 37.5, 40, 42.5, 45, 47.5, and 50 GHz). These frequencies provide a range of radial positions from the edge plasma to the core depending on plasma conditions. The system utilizes a combination of novel features to provide remote control of the probed density wavenumber, the launched polarization (X vs O-mode), and the angle of the launched DBS to match the magnetic field pitch angle. The range of accessible density turbulence wavenumbers (kθ) is reasonably large with normalized wavenumbers kθρs ranging from ≤0.5 to 9 (ion sound gyroradius ρs = 1 cm). This wavenumber range is relevant to a variety of instabilities believed to be important in establishing plasma transport (e.g., ion temperature gradient, trapped electron, electron temperature gradient, micro-tearing, kinetic ballooning modes). The system is specifically designed to address the requirement of density fluctuation wavevector alignment which can significantly reduce the SNR if not accounted for.

Instruments & Instrumentation↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

Enhancing Thomson scattering polychromator performance with multi-pass spectral filters

In photon-deficient, noncollective Thomson scattering diagnostics, filter polychromators are typically employed in the spectral analysis of Thomson-scattered signals to achieve acceptable signal-to-noise performance. Currently, the most common polychromator filter configuration employs a set of single-passband optical filters that define individual spectral channels. Here, we introduce a new spectral analysis method for Thomson scattering based on spectral filters with multiple passbands, referred to as Thomson scattering spectral multiplexing. Implementing multi-bandpass spectral filters on polychromators increases the achievable range of electron temperature measurement for a given number of filters employed. In addition, Thomson scattering spectral multiplexing reduces systematic measurement uncertainty, with fewer required spectral channels, thereby decreasing light loss from reduced optical element interactions. A multi-bandpass filter set, optimized by a genetic algorithm, has been successfully installed and tested on the Helically Symmetric eXperiment (HSX), demonstrating the benefits of the Thomson scattering spectral multiplexing method.

Instruments & Instrumentation↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗