Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inductive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Power factor control system for AC induction motors

A power factor control system for use with ac induction motors was designed which samples lines voltage and current through the motor and decreases power input to the motor proportional to the detected phase displacement between current and voltage. This system provides, less power to the motor, as it is less loaded.

Nola, F. J.↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

ART CCIM PHASE II-A OFF-GAS SYSTEM EVALUATION TEST REPORT

AREVA Federal Services (AFS) is performing a multi-year, multi-phase Advanced Remediation Technologies (ART) project, sponsored by the U.S. Department of Energy (DOE), to evaluate the feasibility and benefits of replacing the existing joule-heated melter (JHM) used to treat high level waste (HLW) in the Defense Waste Processing Facility (DWPF) at the Savannah River Site with a cold crucible induction melter (CCIM). The AFS ART CCIM project includes several collaborators from AREVA subsidiaries, French companies, and DOE national laboratories. The Savannah River National Laboratory and the Commissariat a l’Energie Atomique (CEA) have performed laboratory-scale studies and testing to determine a suitable, high-waste-loading glass matrix. The Idaho National Laboratory (INL) and CEA are performing CCIM demonstrations at two different pilot scales to assess CCIM design and operation for treating SRS sludge wastes that are currently being treated in the DWPF. SGN is performing engineering studies to validate the feasibility of retrofitting CCIM technology into the DWPF Melter Cell. The long-term project plan includes more lab-testing, pilot- and large-scale demonstrations, and engineering activities to be performed during subsequent project phases. A simulant of the DWPF SB4 feed was successfully fed and melted in a small pilot-scale CCIM system during two test series. The OGSE tests provide initial results that (a) provide melter operating conditions while feeding a DWPF SB4 simulant feed, (b) determine the fate of feed organic and metal feed constituents and metals partitioning, and (c) characterize the melter off-gas source term to a downstream off-gas system. The INL CCIM test system was operated continuously for about 30 hours during the parametric test series, and for about 58 hours during the OGSE test. As the DWPF simulant feed was continuously fed to the melter, the glass level gradually increased until a portion of the molten glass was drained from the melter. The glass drain was operated periodically on-demand. A cold cap of unmelted feed was controlled by adjusting the feedrate and melter power levels to obtain the target molten glass temperatures with varying cold cap levels. Three test conditions were performed per the test plan, during which the melter was operated with a target melt temperature of either 1,250oC or 1,300oC, and with either a partial or complete cold cap of unmelted feed on top of the molten glass. Samples of all input and output streams including the starting glass, the simulant feed, the off-gas particulate matter, product glass, and deposits removed from the crucible and off-gas pipe after the test were collected for analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concept for sleeve induction motor with 1-msec mechanical time constant

Conductive sleeve induction motor having a 1-msec mechanical time constant is used with solid-state devices to control all-electric servo power systems. The servomotor rotor inertia is small compared to the maximum force rating of the servo motion, permitting high no-load acceleration.

Wiegand, D. E.↗

Bolt-Tension Sensor

In technique for measuring tensile force of bolt, specially fabricated magnetostrictive washer used as force transducer. Compact, portable inductive electronic sensor placed against washer to measure tension force. New system provides accurate, economical, and convenient way to measure bolt tension in field. Measurements on test assembly shows that tension can be measured to accuracy of about plus or minus 1 percent of load capacity of typical bolt.

Goldie, James H.↗

TAK1 is activated in the myocardium after pressure overload and is sufficient to provoke heart failure in transgenic mice

The transforming-growth-factor-beta-activated kinase TAK1 is a member of the mitogen-activated protein kinase kinase kinase family, which couples extracellular stimuli to gene transcription. The in vivo function of TAK1 is not understood. Here, we investigated the potential involvement of TAK1 in cardiac hypertrophy. In adult mouse myocardium, TAK1 kinase activity was upregulated 7 days after aortic banding, a mechanical load that induces hypertrophy and expression of transforming growth factor beta. An activating mutation of TAK1 expressed in myocardium of transgenic mice was sufficient to produce p38 mitogen-activated protein kinase phosphorylation in vivo, cardiac hypertrophy, interstitial fibrosis, severe myocardial dysfunction, 'fetal' gene induction, apoptosis and early lethality. Thus, TAK1 activity is induced as a delayed response to mechanical stress, and can suffice to elicit myocardial hypertrophy and fulminant heart failure.

NASA Discipline Cardiopulmonary↗

Cold Crucible Induction Melter Testing at The Idaho National Laboratory for the Advanced Remediation Technologies Program

AREVA Federal Services (AFS) is performing a multi-year, multi-phase Advanced Remediation Technologies (ART) project, sponsored by the U.S. Department of Energy (DOE), to evaluate the feasibility and benefits of replacing the existing joule-heated melter (JHM) used to treat high level waste (HLW) in the Defense Waste Processing Facility (DWPF) at the Savannah River Site with a cold crucible induction melter (CCIM). The AFS ART CCIM project includes several collaborators from AREVA subsidiaries, French companies, and DOE national laboratories. The Savannah River National Laboratory and the Commissariat a l’Energie Atomique (CEA) have performed laboratory-scale studies and testing to determine a suitable, high-waste-loading glass matrix. The Idaho National Laboratory (INL) and CEA are performing CCIM demonstrations at two different pilot scales to assess CCIM design and operation for treating SRS sludge wastes that are currently being treated in the DWPF. SGN is performing engineering studies to validate the feasibility of retrofitting CCIM technology into the DWPF Melter Cell. The long-term project plan includes more lab-testing, pilot- and large-scale demonstrations, and engineering activities to be performed during subsequent project phases. This paper provides preliminary results of tests using the engineering-scale CCIM test system located at the INL. The CCIM test system was operated continuously over a time period of about 58 hours. As the DWPF simulant feed was continuously fed to the melter, the glass level gradually increased until a portion of the molten glass was drained from the melter. The glass drain was operated semi-continuously because the glass drain rate was higher than the glass feedrate. A cold cap of unmelted feed was controlled by adjusting the feedrate and melter power levels to obtain the target molten glass temperatures with varying cold cap levels. Three test conditions were performed per the test plan, during which the melter was operated with a target melt temperature of either 1,250oC or 1,300oC, and with either a partial or complete cold cap of unmelted feed on top of the molten glass. Samples of all input and output streams were collected for analysis. Laboratory analyses and mass balances will be used to determine the fate of feed constituents, especially Cs. The melter off-gas composition was measured at the melter outlet duct. Sample analyses are still in progress; but preliminary conclusions are possible using the continuous emissions monitoring system (CEMS) data. The concentrations of CO2, CO, CH4, total hydrocarbons (THC), and NOx increased with increasing feedrate of the feed containing water, nitrates, and formate. Over 90% of the formate (a reductant used in the simulant feed) was converted to CO2 and water vapor. Under 6-9% of the H in the formate converted to H2, and under 1% of the formate decomposed to gaseous hydrocarbons. This small degree of formate conversion to potentially flammable off-gas species reduces off-gas flammability concerns. About 36-61% of the NOx in the off-gas (evolved from nitrites and nitrates in the feed) was destroyed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Investigation of the Effect of Rolling on the Localized Stress and Strain Induction for Wire + Arc Additive Manufactured Structures

Cold rolling can be used in-process or post-process to improve microstructure, mechanical properties and residual stress in directed-energy-deposition techniques, such as the high deposition rate wire + arc additive manufacturing (WAAM) process. Finite element simulations of the rolling process are employed to investigate the effect of rolling parameters, in particular rolling load and roller profile radius on the residual stress field as well as plastic strain distribution for the profiled roller. The results show the response to rolling of commonly used structural metals in WAAM, i.e., AA2319, S335JR steel and Ti-6Al-4V, taking into account the presence of residual stresses. The rolling load leads to changes in the location and the maximum value of the compressive residual stresses, as well as the depth of the compressive residual stresses. However, the roller profile radius only changes the maximum value of these compressive residual stresses. Changing the rolling load influences the equivalent plastic strain close to the top surface of the wall as well as in deeper areas, whereas the influence of the roller profile radius is negligible. The plastic strain distribution is virtually unaffected by the initial residual stresses prior to rolling. Finally, design curves were generated from the simulations for different materials, suggesting ideal rolling load and roller profile combinations for microstructural improvement requiring certain plastic strains at a specific depth of the additive structure.

36 MATERIALS SCIENCE↗

Efficient weakly-radiative wireless energy transfer: An EIT-like approach

Inspired by a quantum interference phenomenon known in the atomic physics community as electromagnetically induced transparency (EIT), we propose an efficient weakly radiative wireless energy transfer scheme between two identical classical resonant objects, strongly coupled to an intermediate classical resonant object of substantially different properties, but with the same resonance frequency. The transfer mechanism essentially makes use of the adiabatic evolution of an instantaneous (so called 'dark') eigenstate of the coupled 3-object system. Our analysis is based on temporal coupled mode theory (CMT), and is general enough to be valid for various possible sorts of coupling, including the resonant inductive coupling on which witricity-type wireless energy transfer is based. We show that in certain parameter regimes of interest, this scheme can be more efficient, and/or less radiative than other, more conventional approaches. A concrete example of wireless energy transfer between capacitively-loaded metallic loops is illustrated at the beginning, as a motivation for the more general case. We also explore the performance of the currently proposed EIT-like scheme, in terms of improving efficiency and reducing radiation, as the relevant parameters of the system are varied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel LCC-CLCC Resonant Tuning Network for Light-Load Conditions in Wireless Power Transfer Systems

In wireless power transfer (WPT) systems, voltage and current distortions are observed at the vehicle side rectifier when power flow is from grid to vehicle (G2V) under light load conditions. These distortions can increase switching losses and decrease the overall efficiency of the WPT system. To address this issue, this paper proposes adding a higher value inductor in series with the original LCC tuning network at the vehicle side. However, increasing the series inductance causes the input impedance and phase angle to move away from the resonant frequency. To solve this problem, a capacitor is added in series to tune out the difference between the original and modified inductor values. This series tuning capacitor also improves the power factor and brings the input impedance and phase angle back to the resonant frequency. The traditional LCC-LCC and proposed LCC-CLCC WPT systems are compared and analyzed analytically, and simulated in a MATLAB/Simulink environment to verify parameters such as efficiency and power transfer capacity. An experimental prototype is implemented and compared with the simulation. The obtained results confirm the validity of the proposed method.

Harave, Sudarshan↗

High-Speed Electromagnetic Drives of Shock Systems

The capabilities of a shock system with an electromagnetic shock unit creating a load with peak acceleration 10{sup 6} m/s{sup 2} for samples attached to the free end of the waveguide are considered.

42 ENGINEERING↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fatigue and Fracture Behavior of Induction-Hardened and Superimposed Mechanically Post-treated Steel Surface Layers

This paper focuses on the effect of induction hardening and superimposed stroke peening, as mechanical post-treatment, on the fatigue and fracture behavior of gas engine 50CrMo4 steel crankshafts. Comprehensive analysis in regard to local microstructure, hardness and residual stress profile in depth is performed to examine the local characteristics of the investigated crankshafts and the representative notched round specimens. An evaluation of the equivalent von Mises residual stress condition in depth demonstrates an increase by over 70% of the average compressive residual stress state due to the superimposed stroke peening compared to the induction-hardened condition. Rotating bending fatigue tests reveal that the additional stroke-peening process elevates the high-cycle fatigue strength of the induction-hardened surface layer by 20%, which validates the beneficial effect of the enhanced compressive residual stress state. An extensive fracture surface analysis presents the position of crack initiation for each investigated manufacturing condition indicating that the failure origin preferably starts at the surface for higher load levels. On the contrary, the crack initiation shifts beneath the hardened layer in case of lower load levels leading to subsurface failure origin.

36 MATERIALS SCIENCE↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

Combined Normal and Disruption, Electromagnetic Transient, Thermal, and Structural Analysis of COMPASS Upgrade

We report that COMPASS Upgrade is a replacement for the COMPASS device at the Institute of Plasma Physics (IPP) of the Czech Academy of Sciences. It is a cryogenic copper machine with a major radius of 0.89 m, with 5 T at the plasma centerline and 2-MA plasma current. It is intended to develop ITER relevant plasma densities and high power fluxes in the divertor region. The entire vacuum vessel is planned to reach 500 °C. The COMPASS-U TF coil is a bitter plate-like design with radial conductor plates that extend the width of the TF inner leg. Currents redistribute radially based on resistive and inductive effects. This necessitates an electromagnetic (EM) transient analysis of the coil current distribution. For copper coils like COMPASS Upgrade, the solution must be coupled with a thermal solution to properly include the temperature-dependent resistive effects. The EM transient solution includes the TF magnetic loads, and a stress pass on the results produces in-plane loads. The EM solution chosen requires inclusion of all the conducting and nonconducting regions surrounding the TF coil. With the TF current distribution solved, the addition of the poloidal coils and resulting background fields allows the determination of the out-of-plane loads. Integration of the Joule heating produced from the EM solution produces temperature distributions throughout the shot, which can be read in to a structural pass to include thermal stresses in the evaluation. This is true of both TF and PF temperature prediction with appropriate packing fractions. Currents in the PF coils, with computed background fields, produce Lorentz loads. Time transients of the PF currents produce startup eddy currents in the structures included in the model; inclusion of the vessel and other passive structures allows these to be included in a stress pass. The EM transient solution includes all the elements needed for a disruption analysis with prescribed motions and quench of the plasma. From a model originally intended to simulate current diffusion in the TF coil, the analysis can be refined to be used to predict the performance of most of the components of the tokamak or provide boundary conditions for more detailed submodels. In this article, the use of the current diffusion model for bounding assessments of the COMPASS Upgrade TF, PF, vessel, external structure, and disruption analyses will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic braking for Mars spacecraft

Aerobraking concepts are being studied to improve performance and cost effectiveness of propulsion systems for Mars landers and Mars interplanetary spacecraft. Access to megawatt power levels (nuclear power coupled to high-storage inductive or capacitive devices) on a manned Mars interplanetary spacecraft may make feasible electromagnetic braking and lift modulation techniques which were previously impractical. Using pulsed microwave and magnetic field technology, potential plasmadynamic braking and hydromagnetic lift modulation techniques have been identified. Entry corridor modulation to reduce loads and heating, to reduce vertical descent rates, and to expand horizontal and lateral landing ranges are possible benefits. In-depth studies are needed to identify specific design concepts for feasibility assessments. Standing wave/plasma sheath interaction techniques appear to be promising. The techniques may require some tailoring of spacecraft external structures and materials. In addition, rapid response guidance and control systems may require the use of structurally embedded sensors coupled to expert systems or to artificial intelligence systems.

Holt, A. C.↗

Field Repair Of Thermoplastic Windows And Canopies

Toroid bonding techniques further developed to meet typical field-repair requirements. Induction-heating power supply engineered into "ruggedized" solid-state unit, in a 1-ft to the third power package weighing 20 lb. Hand-held bonding gun weighing 3 lb plugs into this power supply on long cord. Maximum power required is 300 W. Lightly loaded repair bonds made in several minutes at average power input of 150 W on metallic, polymeric, or polymermatrix materials.

Fox, Robert L.↗