Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image understanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

TU-PIS-Exhibit Hall-2: How to Move Beyond Dose Monitoring to Imaging Performance Utilization

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

In Situ EXAFS-Based Nanothermometry of Heterodimer Nanocrystals under Induction Heating

The ability to heat nanocrystalline materials through magnetic induction has been used in the fields of catalysis, biomedical sciences, and polymer degradation. However, the working temperature to which the inductively coupled material rises is still poorly understood. Herein, we use extended X-ray absorption fine structure spectroscopy in conjunction with thermal imaging to improve the understanding of heating in inductively coupled systems. After extraction of the Debye–Waller factor from the spectroscopy, we obtain the temperature of inductively heated nanocrystals from the correlated Debye model. We combine carbon-supported iron oxide nanocrystals as induction heating agents with platinum nanocrystals as thermal probes. By testing these nanocrystal species as both unattached nanocrystals and heterodimers, we report that nanostructured systems show a significant temperature difference of up to 73.60 °C when compared to their local support environment. Furthermore, this result has implications for inductively heated catalysis, magnetic hyperthermia for targeted cell death, and polymer synthesis.

09 BIOMASS FUELS↗

Investigating flow patterns and related dynamics in multi-instability turbulent plasmas using a three-point cross-phase time delay estimation velocimetry scheme

Complexities of flow patterns in the azimuthal cross-section of a cylindrical magnetized helicon plasma and the corresponding plasma dynamics are investigated by means of a novel scheme for time delay estimation velocimetry. The advantage of this introduced method is the capability of calculating the time-averaged 2D velocity fields of propagating wave-like structures and patterns in complex spatiotemporal data. It is able to distinguish and visualize the details of simultaneously present superimposed entangled dynamics and it can be applied to fluid-like systems exhibiting frequently repeating patterns (e.g., waves in plasmas, waves in fluids, dynamics in planetary atmospheres, etc.). The velocity calculations are based on time delay estimation obtained from cross-phase analysis of time series. Each velocity vector is unambiguously calculated from three time series measured at three different non-collinear spatial points. This method, when applied to fast imaging, has been crucial to understand the rich plasma dynamics in the azimuthal cross-section of a cylindrical linear magnetized helicon plasma. The capabilities and the limitations of this velocimetry method are discussed and demonstrated for two completely different plasma regimes, i.e., for quasi-coherent wave dynamics and for complex broadband wave dynamics involving simultaneously present multiple instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Changes in Thermospheric O/N2 Derived from UVI Auroral Images

A rigorous test of our understanding of the coupled ionosphere-thermosphere and its response to geomagnetic storms is the ability to reproduce observed storm effects as seen in the ionosphere and neutral atmosphere. The concept of compositional change is central to studies of thermosphere response to storm conditions. In particular, information about compositional change within the highly dynamic auroral region is limited. The Ultraviolet Imager (UVI) is designed to view the full auroral region using five filters to isolate emissions from atomic oxygen (1304 and 1356) and N2 LBH. This spectral resolution allows auroral energy characteristics to be derived by two separate methods from examining ratios of observed intensities (OI 1356/LBHL or LBHS/LBHL). The LBHS:LBHL ratio is typically used as the mean energy diagnostic since the OI 1356 emission is dependent on changes in the atomic oxygen density, and these changes relative to N2 can be large. However, once the mean energy has been specified by the LBH ratio, this variability in OI 1356 emission can be exploited as a direct diagnostic of total atomic oxygen column density. This opens the potential of using UVI images to monitor the temporal and spatial response of thermospheric O to high latitude forcing within the auroral regions. Initial results of this type of analysis will be presented along with discussion of its limitations and capabilities.

Germany, G. A.↗

WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.

60 APPLIED LIFE SCIENCES↗

SeaDAS Tutorial: Applying Color Ramps to ACOLITE Turbidity Products

This tutorial provides step-by-step instructions for applying color ramps and legends to ACOLITE turbidity products derived from the Dogliotti turbidity equation. The user inputs their own image and the resulting product is a colorized visualization of turbidity. This visualization provides the user with a better understanding of turbidity in their image and can be used to support further analysis of turbidity patterns.

Kelly Young↗

PRMI: A Dataset of Minirhizotron Images for Diverse Plant Root Study

Understanding a plant's root system architecture (RSA) is crucial for a variety of plant science problem domains including sustainability and climate adaptation. Minirhizotron (MR) technology is a widely-used approach for phenotyping RSA non-destructively by capturing root imagery over time. Precisely segmenting roots from the soil in MR imagery is a critical step in studying RSA features. In this paper, we introduce a large-scale dataset of plant root images captured by MR technology. In total, there are over 72K RGB root images across six different species including cotton, papaya, peanut, sesame, sunflower, and switchgrass in the dataset. The images span a variety of conditions including varied root age, root structures, soil types, and depths under the soil surface. All of the images have been annotated with weak image-level labels indicating whether each image contains roots or not. The image-level labels can be used to support weakly supervised learning in plant root segmentation tasks. In addition, 63K images have been manually annotated to generate pixel-level binary masks indicating whether each pixel corresponds to root or not. These pixel-level binary masks can be used as ground truth for supervised learning in semantic segmentation tasks. By introducing this dataset, we aim to facilitate the automatic segmentation of roots and the research of RSA with deep learning and other image analysis algorithms.

Xu, Weihuang↗

Multi-modality molecular imaging of aortic aneurysms

Aneurysms of the thoracic and abdominal aorta are common and can be associated with significant morbidity and mortality when complications, including dissection, rupture, or thrombosis, occur. Current approaches to diagnosis and risk stratification rely on measurements of aneurysm size and rate of growth, often using various imaging modalities, which may be suboptimal in identifying patients at the highest and lowest risk of complications. Targeting the biological processes underlying aneurysm formation and expansion with molecular imaging offers an exciting opportunity to characterize aortic aneurysms beyond size and address current gaps in our approach to diagnosis and treatment. In this review, we summarize the epidemiology and biology of aortic aneurysms and highlight the role of molecular imaging in furthering our understanding of aneurysm pathogenesis and its potential future role in guiding management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification and correction of temporal and spatial distortions in scanning transmission electron microscopy

Scanning transmission electron microscopy (STEM) has become the technique of choice for quantitative characterization of atomic structure of materials, where the minute displacements of atomic columns from high-symmetry positions can be used to map strain, polarization, octahedra tilts, and other physical and chemical order parameter fields. The latter can be used as inputs into mesoscopic and atomistic models, providing insight into the correlative relationships and generative physics of materials on the atomic level. However, these quantitative applications of STEM necessitate understanding the microscope induced image distortions and developing the pathways to compensate them both as part of a rapid calibration procedure for in situ imaging, and the post-experimental data analysis stage. Here, we explore the spatiotemporal structure of the microscopic distortions in STEM using multivariate analysis of the atomic trajectories in the image stacks. Based on the behavior of principal component analysis (PCA), we develop the Gaussian process (GP)-based regression method for quantification of the distortion function. The limitations of such an approach and possible strategies for implementation as a part of in-line data acquisition in STEM are discussed. Here, the analysis workflow is summarized in a Jupyter notebook that can be used to retrace the analysis and analyze the reader's data.

36 MATERIALS SCIENCE↗

Development of an optical Zn 2+ probe based on a single fluorescent protein

Various fluorescent probes have been developed to reveal the biological functions of intracellular labile Zn 2+ . Here we present Green Zinc Probe (GZnP), a novel genetically encoded Zn 2+ sensor design based on a single fluorescent protein (single-FP). The GZnP sensor is generated by attaching two zinc fingers (ZF) of the transcription factor Zap1 (ZF1 and ZF2) to the two ends of a circularly permuted green fluorescent protein (cpGFP). Formation of ZF folds induces interaction between the two ZFs, which induces a change in the cpGFP conformation, leading to an increase in fluorescence. A small sensor library is created to include mutations in the ZFs, cpGFP and linkers between ZF and cpGFP to improve signal stability, sensor brightness and dynamic range based on rational protein engineering and computational design by Rosetta. Using a cell-based library screen, we identify sensor GZnP1 which demonstrates a stable maximum signal, decent brightness (QY = 0.42 at apo state), as well as specific and sensitive response to Zn 2+ in HeLa cells (F max /F min = 2.6, K d = 58 pM, pH 7.4). The subcellular localizing sensors mito-GZnP1 (in mitochondria matrix) and Lck-GZnP1 (on plasma membrane) display sensitivity to Zn 2+ (F max /F min = 2.2). In conclusion, this sensor design provides freedom to be used in combination with other optical indicators and optogenetic tools for simultaneous imaging and advancing our understanding of cellular Zn 2+ function.

59 BASIC BIOLOGICAL SCIENCES↗

Real-Time Diagnostics of 2D Crystal Transformations by Pulsed Laser Deposition: Controlled Synthesis of Janus WSSe Monolayers and Alloys

Energetic processing methods such as hyperthermal implantation hold special promise to achieve the precision synthesis of metastable two-dimensional (2D) materials such as Janus monolayers; however, they require precise control. Here, we report a feedback approach to reveal and control the transformation pathways in materials synthesis by pulsed laser deposition (PLD) and apply it to investigate the transformation kinetics of monolayer WS 2 crystals into Janus WSSe and WSe 2 by implantation of Se clusters with different maximum kinetic energies (<42 eV/Se-atom) generated by laser ablation of a Se target. Real-time Raman spectroscopy and photoluminescence are used to assess the structure, composition, and optoelectronic quality of the monolayer crystal as it is implanted with well-controlled fluxes of selenium for different kinetic energies that are regulated with in situ ICCD imaging, ion probe, and spectroscopy diagnostics. First-principles calculations, XPS, and atomic-resolution HAADF STEM imaging are used to understand the intermediate alloy compositions and their vibrational modes to identify transformation pathways. The real-time kinetics measurements reveal highly selective top-layer conversion as WS 2 transforms through WS 2(1–x) Se 2x alloys to WSe 2 and provide the means to adjust processing conditions to achieve fractional and complete Janus WSSe monolayers as metastable transition states. The general approach demonstrates a real-time feedback method to achieve Janus layers or other metastable alloys of the desired composition, and a general means to adjust the structure and quality of materials grown by PLD, addressing priority research directions for precision synthesis with real-time adaptive control.

2D materials↗

Two coexisting liquid phases in switchable ionic liquids

Switchable ionic liquids (SWILs) derived from organic bases and alcohols are attractive due to their applications in gas capture, separations, and nanomaterial synthesis. However, their exact solvent structure still remains a mystery. Here, we present the first chemical mapping of a SWIL solvent structure using in situ time-of-flight secondary ion mass spectrometry. In situ chemical mapping discovers two coexisting liquid phases and molecular structures vastly different from conventional ionic liquids. SWIL chemical speciation is found to be more complex than the known stoichiometry. Dimers and ionic clusters have been identified in SIMS spectra; and confirmed to be the chemical species differentiating from non-ionic liquids via spectral principal component analysis. Our unique in situ molecular imaging has advanced the understanding of SWIL chemistry and how this “heterogeneous” liquid structure may impact SWILs’ physical and thermodynamic properties and associated applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chapter 6: Luminescence and Thermal Imaging of Thin-Film Photovoltaic Materials, Devices, and Modules

In this chapter, we describe luminescence and thermal imaging in the context of thin-film PV devices. First, we discuss both traditional and developing experimental designs, including dark LIT (DLIT), illuminated LIT, PL using different illumination configurations, traditional EL performed under forward -bias current injection, and contactless EL induced with sub -cell illumination patterns. Next, we provide some brief theoretical background to highlight relationships between fundamental materials properties and the resulting luminescence and thermal images. Finally, we give examples of thin-film PV PL, EL, and LIT images to demonstrate the utility of these imaging methods ranging from understanding the microstructure of active layers to managing the quality and reliability of full PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Obtaining anisotropic velocity data for proper depth seismic imaging

The paper deals with the problem of obtaining anisotropic velocity data due to continuous acoustic impedance-based measurements while scanning in the axial direction along the walls of the borehole. Diagrams of full conductivity of the piezoceramic transducer were used to derive anisotropy parameters of the rock sample. The measurements are aimed to support accurate depth imaging of seismic data. Understanding these common anisotropy effects is important when interpreting data where it is present.

58 GEOSCIENCES↗

Multimodal microfluidic platform for controlled culture and analysis of unicellular organisms

Modern live-cell imaging approaches permit real-time visualization of biological processes, yet limitations exist for unicellular organism isolation, culturing and long-term imaging that preclude fully understanding how cells sense and respond to environmental perturbations and the link between single-cell variability and whole-population dynamics. Here we present a microfluidic platform that provides fine control over the local environment with the capacity to replace media components at any experimental time point, and provides both perfused and compartmentalized cultivation conditions depending on the valve configuration. In this work, the functionality and flexibility of the platform were validated using both bacteria and yeast having different sizes, motility and growth media. The demonstrated ability to track the growth and dynamics of both motile and non-motile prokaryotic and eukaryotic organisms emphasizes the versatility of the devices, which with further scale-up should enable studies in bioenergy and environmental research.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗