Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

Integrated Dual Imaging Detector

A new type of image detector was designed to simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging detector (IDID) consists of a lenslet array and a polarizing beamsplitter bonded to a commercial charge coupled device (CCD). The IDID simplifies the design and operation of solar vector magnetographs and the imaging polarimeters and spectroscopic imagers used, for example, in atmosphere and solar research. When used in a solar telescope, the vector magnetic fields on the solar surface. Other applications include environmental monitoring, robot vision, and medical diagnoses (through the eye). Innovations in the IDID include (1) two interleaved imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 5) electrons per pixel); (3) simultaneous readout and display of both images; and (4) laptop computer signal processing to produce polarization maps in field situations.

Rust, David M.↗

An equipotential model for auroral arcs

Shaped charge barium release data and high-speed auroral image data show the likely existence of anomalously large (about 1 V/m referred to the 100-km level) electric fields at distances the order of one earth radius above the earth. A model of the electrostatic field above an auroral arc is proposed in which the magnetic field lines are not all equipotentials. Use is made of recent theoretical work on oblique current-driven electrostatic shocks to demonstrate the plausibility of nonequipotential field lines. The model is addressed to the structure of inverted-V electron spectra, current continuity between magnetosphere and ionosphere, and the results of recent shaped charge barium experiments. The model is used to identify specific gaps in our understanding of auroral phenomena.

Swift, D. W.↗

An evaluation of an ICCD imager of dynamic range expansion technique and application of insitu procedures for life-time extension

Research toward practical implementation of the Intensified Charge Coupled Device (ICCD) as a photon-counting array detector for astronomy is reported. The first area of concentration was to determine the rate and extent of the lifetime limiting damage to the CCD caused by the impact of high energy electrons, and to find whether various methods of annealing the damage were productive. The second effort was to determine the performance of the ICCD in a photon-counting mode to produce extended dynamic range measurements. There are two main effects that appear as the practical results of the electron damage to the CCD. One is an increase in the leakage current, i.e., the normal thermal generation of charge carriers in the silicon that provides a background dark signal that adds to the light produced image. In an undamaged CCD, the leakage current is usually fairly uniform across the photosensitive area of the silicon chip, with the exception of various bright pixels which have an anomalous leakage current well above the overall level.

Currie, D. G.↗

Scientific charge-coupled devices

The charge-coupled device dominates an ever-increasing variety of scientific imaging and spectroscopy applications. Recent experience indicates, however, that the full potential of CCD performance lies well beyond that realized in devices currently available.Test data suggest that major improvements are feasible in spectral response, charge collection, charge transfer, and readout noise. These properties, their measurement in existing CCDs, and their potential for future improvement are discussed in this paper.

Janesick, James R.↗

Charge-coupled-device X-ray detector performance model

A model that predicts the performance characteristics of CCD detectors being developed for use in X-ray imaging is presented. The model accounts for the interactions of both X-rays and charged particles with the CCD and simulates the transport and loss of charge in the detector. Predicted performance parameters include detective and net quantum efficiencies, split-event probability, and a parameter characterizing the effective thickness presented by the detector to cosmic-ray protons. The predicted performance of two CCDs of different epitaxial layer thicknesses is compared. The model predicts that in each device incomplete recovery of the charge liberated by a photon of energy between 0.1 and 10 keV is very likely to be accompanied by charge splitting between adjacent pixels. The implications of the model predictions for CCD data processing algorithms are briefly discussed.

Bautz, M. W.↗

Spatially resolved methane band photometry of Saturn. I - Absolute reflectivity and center-to-limb variations in the 6190-, 7250-, and 8900-A bands

Spatially resolved measurements of Saturn's absolute reflectivity in methane bands at 6190, 7250, and 8900 A and in nearby continuum regions are presented. Images were obtained through narrow-band interference filters with a 500 x 500-pixel charge-coupled device. Band/continuum ratios were measured to high accuracy by referencing to the ring brightness in each image. Several data processing techniques enhanced the quality of the observations. These are the use of the ring symmetry to find center position and orientation, accurate subtraction of ring light, and constrained image deconvolution. Uncertainty in the continuum absolute reflectivity is within 10%. Uncertainties in band/continuum ratios are from one to several percent. The Equatorial Zone was much brighter than any other latitude in the strong 8900 band image. Northern midlatitudes were brighter than southern midlatitudes. The latter observation indicates fewer high-altitude aerosols in the south, a possible result of atmospheric dynamics or seasonal sublimation of NH3 crystals. The data are tabulated and presented in a form suitable for quantitative scattering model analyses.

West, R. A.↗

An Integrated Imaging Detector of Polarization and Spectral Content

A new type of image detector has been designed to simultaneously analyze the polarization of light at all picture elements in a scene. The Integrated Dual Imaging Detector (IDID) consists of a polarizing beamsplitter bonded to a charge-coupled device (CCD), with signal-analysis circuitry and analog-to-digital converters, all integrated on a silicon chip. It should be capable of 1:10(exp 4) polarization discrimination. The IDID should simplify the design and operation of imaging polarimeters and spectroscopic imagers used, for example, in atmospheric and solar research. Innovations in the IDID include (1) two interleaved 512 x 1024-pixel imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 6) electrons per pixel); (3) simultaneous readout of both images at 10 million pixels per second each; (4) on-chip analog signal processing to produce polarization maps in real time; (5) on-chip 10-bit A/D conversion. When used with a lithium-niobate Fabry-Perot etalon or other color filter that can encode spectral information as polarization, the IDID can collect and analyze simultaneous images at two wavelengths. Precise photometric analysis of molecular or atomic concentrations in the atmosphere is one suggested application. When used in a solar telescope, the IDID will charge the polarization, which can then be converted to maps of the vector magnetic fields on the solar surface.

Rust, D. M.↗

Recent developments in CID imaging

Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.

Michon, G. J.↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

UBV stellar photometry of the 30 Doradus region of the large Magellanic Cloud with the Hubble Space Telescope

We report on Planetary Camera observations of the central region of 30 Doradus in the Large Magellanic Cloud (LMC). These images of 30 Doradus are the first `deep' Hubble Space Telescope (HST) exposures that have appropriate photometric calibration. The B band (F439W) image, which shows R136a at the center of the PC6 charge coupled device (CCD) chip, reveals over 200 stars within 3 sec of the center of R13a, and over 800 stars in a 35 sec x 35 sec area. We used Malumuth et al.'s (1991) Point Spread Function (PSF)-fitting method to measure the magnitudes of all stars on the PC6 chip. These new B magnitudes, along with U and V magnitudes from archival PC images, yield a luminosity function, mass density profile, and initial mass function of the 30 Doradus ionizing cluster. The mass distribution is well fit by a King model with a core radius, R(sub c) = 0.96 sec (0.24 pc), a tidal radius, R(sub t) = 110 sec (28 pc), and a total mass, Mass = 16,800 solar mass. Both the luminosity function and initial mass function show evidence for mass segregation, in the sense that the central region has a higher fraction of massive stars than the outer regions. This is the first observational evidence for mass segregation in a very young cluster (age approximately 3 million years). The observations admit the hypothesis that the mass segregation occurred in the process of star formation and/or that the mass segregation is the result of dynamical evolution.

Malumuth, Eliot M.↗

Physical and chemical analysis of a Ni/H2 cell

A cycled aerospace nickel hydrogen (Ni/H2) cell was subjected to destructive physical analysis to determine the reason for a capacity loss after 5,967 cycles at 60 percent depth of discharge. The positive plates in the cell were analyzed in terms of chemical composition, active material utilization, charge efficiency, and thickness increase. The microstructure of a cross section of the positive plate was determined by backscattered electron image analysis. The results suggest that the capacity loss in the cell is caused by low charge acceptance and low active material utilization at the positive plate. The oxidized nickel species content of the positive plate increased due to corrosion of the nickel sintered skeleton. This appears to circumvent the orderly reaction of the active material. Microstructural analysis has indicated that a new phase of active material is formed with cycling.

H Vaidyanathan↗

Stereo electro-optical tracker study for the measurement of model deformations at the National Transonic Facility

The effects of model vibration, camera and window nonlinearities, and aerodynamic disturbances in the optical path on the measurement of target position is examined. Window distortion, temperature and pressure changes, laminar and turbulent boundary layers, shock waves, target intensity and, target vibration are also studied. A general computer program was developed to trace optical rays through these disturbances. The use of a charge injection device camera as an alternative to the image dissector camera was examined.

Hertel, R. J.↗

Electron-Focus Adjustment for Photo-Optical Imagers

Internal electron focus made independent of optical focus. Procedure enables fine tuning of internal electron-focusing system of photo-optical imager, without complication by imperfections of associated external optics. Applicable to imager in which electrons emitted from photocathode in optical focal plane, then electrostatically and/or magnetically focused to replica of image in second focal plane containing photodiodes, phototransistorss, charge-coupled devices, multiple-anode outputs, or other detectors.

Fowler, Walter B.↗

Orbit determination accuracy assessment for an asteroid flyby - A Galileo case study

The Galileo spacecraft may be targeted for a close flyby of an asteroid on its way to an encounter with Jupiter. An orbit determination accuracy analysis was carried out for the case of the asteroid 29 Amphitrite based on the use of radio metric and optical data types. Prior to encounter, the uncertainty in the asteroid's position, based on astrometric observations from earth, amounts to several hundred kilometers. This ephemeris uncertainty constitutes the dominant error in the determination of the spacecraft orbit with respect to Amphitrite. It is shown that the spacecraft-asteroid relative position can be improved by imaging asteroid-star pairs with the Galileo charge-coupled device (CCD) camera, enabling an accurate flyby of the asteroid. The main benefit of optical navigation is to enable the instrument pointing updates necessary for closeup viewing of the asteroid. A discussion of the evolution of the target error ellipse parameters as a function of data coverage and various combinations of radiometric and optical data types is also presented.

Kechichian, Jean A.↗

The 2nd Symposium on the Frontiers of Massively Parallel Computations

Programming languages, computer graphics, neural networks, massively parallel computers, SIMD architecture, algorithms, digital terrain models, sort computation, simulation of charged particle transport on the massively parallel processor and image processing are among the topics discussed.

Mills, Ronnie↗

A Pulsating X-Ray Hot Spot on Jupiter

Previous observations of jovian auroral x-ray emissions provided limited spectral information and extensive but low spatial resolution images. These emissions have been thought to result from charge exchange and excitation of energetic sulfur and oxygen ions precipitating from the outer edge of the Io Plasma Torus; bremsstrahlung emission from precipitating energetic electrons is too inefficient to produce the x-ray emissions. However, new high spatial resolution observations demonstrate that most of Jupiter's northern auroral x-rays come from a hot spot located much further north than the footprint of the Io Plasma Torus and which is even poleward of the main ultraviolet auroral oval. The hot spot appears fixed in magnetic latitude and longitude and occurs in a region where anomalous infrared and ultraviolet emissions have also been observed. Interestingly, the hot spot x-rays pulsate with an approximately 40-minute period, a period similar to that reported for high-latitude radio and energetic electron bursts observed by near-Jupiter spacecraft. These results invalidate the idea that jovian x-ray emissions are mainly excited by steady precipitation of energetic heavy ions from the region of the Io Plasma Torus. Instead, the x-rays appear to result from currently unexplained processes in the outer magnetosphere that produce highly localized and highly variable emissions over an extremely wide range of wavelengths.

Gladstone, G. R.↗

GEMS X-ray Polarimeter Performance Simulations

The Gravity and Extreme Magnetism Small explorer (GEMS) is an X-ray polarization telescope selected as a NASA small explorer satellite mission. The X-ray Polarimeter on GEMS uses a Time Projection Chamber gas proportional counter to measure the polarization of astrophysical X-rays in the 2-10 keV band by sensing the direction of the track of the primary photoelectron excited by the incident X-ray. We have simulated the expected sensitivity of the polarimeter to polarized X-rays. We use the simulation package Penelope to model the physics of the interaction of the initial photoelectron with the detector gas and to determine the distribution of charge deposited in the detector volume. We then model the charge diffusion in the detector,and produce simulated track images. Within the track reconstruction algorithm we apply cuts on the track shape and focus on the initial photoelectron direction in order to maximize the overall sensitivity of the instrument, using this technique we have predicted instrument modulation factors nu(sub 100) for 100% polarized X-rays ranging from 10% to over 60% across the 2-10 keV X-ray band. We also discuss the simulation program used to develop and model some of the algorithms used for triggering, and energy measurement of events in the polarimeter.

Baumgartner, Wayne H.↗