Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Development of a large pixel, spectrally optimized, pinned photodiode/interline charge coupled device (CCD) detector for the Earth Observing System (EOS)/Moderate-Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument

A pinned photodiode/interline CCD Detector Array is under development for the EOS/MODIS-T project. Outstanding features of the device include large pixels, spectrally optimized fill factors, and blooming protection. The detector has 30 spatial rows and 32 spectral columns. The device layout is split into two halves; each half has its own detector area, storage area, and output structure.

Ewin, Audrey J.↗

Portable Airborne Laser System Measures Forest-Canopy Height

(PALS) is a combination of laser ranging, video imaging, positioning, and data-processing subsystems designed for measuring the heights of forest canopies along linear transects from tens to thousands of kilometers long. Unlike prior laser ranging systems designed to serve the same purpose, the PALS is not restricted to use aboard a single aircraft of a specific type: the PALS fits into two large suitcases that can be carried to any convenient location, and the PALS can be installed in almost any local aircraft for hire, thereby making it possible to sample remote forests at relatively low cost. The initial cost and the cost of repairing the PALS are also lower because the PALS hardware consists mostly of commercial off-the-shelf (COTS) units that can easily be replaced in the field. The COTS units include a laser ranging transceiver, a charge-coupled-device camera that images the laser-illuminated targets, a differential Global Positioning System (dGPS) receiver capable of operation within the Wide Area Augmentation System, a video titler, a video cassette recorder (VCR), and a laptop computer equipped with two serial ports. The VCR and computer are powered by batteries; the other units are powered at 12 VDC from the 28-VDC aircraft power system via a low-pass filter and a voltage converter. The dGPS receiver feeds location and time data, at an update rate of 0.5 Hz, to the video titler and the computer. The laser ranging transceiver, operating at a sampling rate of 2 kHz, feeds its serial range and amplitude data stream to the computer. The analog video signal from the CCD camera is fed into the video titler wherein the signal is annotated with position and time information. The titler then forwards the annotated signal to the VCR for recording on 8-mm tapes. The dGPS and laser range and amplitude serial data streams are processed by software that displays the laser trace and the dGPS information as they are fed into the computer, subsamples the laser range and amplitude data, interleaves the subsampled data with the dGPS information, and records the resulting interleaved data stream.

Nelson, Ross↗

Imaging Plasma Density Structures in the Soft X-Rays Generated by Solar Wind Charge Exchange with Neutrals

Both heliophysics and planetary physics seek to understand the complex nature of the solar wind's interaction with solar system obstacles like Earth's magnetosphere, the ionospheres of Venus and Mars, and comets. Studies with this objective are frequently conducted with the help of single or multipoint in situ electromagnetic field and particle observations, guided by the predictions of both local and global numerical simulations, and placed in context by observations from far and extreme ultraviolet (FUV, EUV), hard X-ray, and energetic neutral atom imagers (ENA). Each proposed interaction mechanism (e.g., steady or transient magnetic reconnection, local or global magnetic reconnection, ion pick-up, or the Kelvin- Helmholtz instability) generates diagnostic plasma density structures. The significance of each mechanism to the overall interaction (as measured in terms of atmospheric/ionospheric loss at comets, Venus, and Mars or global magnetospheric/ionospheric convection at Earth) remains to be determined but can be evaluated on the basis of how often the density signatures that it generates are observed as a function of solar wind conditions. This paper reviews efforts to image the diagnostic plasma density structures in the soft (low energy, 0.1-2.0 keV) X-rays produced when high charge state solar wind ions exchange electrons with the exospheric neutrals surrounding solar system obstacles.

Sibeck, David G.↗

Backside charging of the CCD

Until recently, the usefulness of the charge coupled device (CCD) as an imaging sensor was thought to be restricted to within rather narrow boundaries of the visible and near IR spectrum. However, since the discovery of backside charging the full potential of CCD performance is now realized. Indeed, the technique of backside charging not only allows the CCD to be used directly in the UV, EUV, and soft X-ray regimes, it has opened up new opportunities in optimizing charge collection processes as well. The technique of backside charging is discussed, and its properties, use, and potential in the future as it applies to the CCD are described.

Janesick, J.↗

Simultaneous neutron and X-ray tomography for visualization of graphite electrode degradation in fast-charged lithium-ion batteries

Advanced battery characterization using neutron and X-ray-based imaging modalities is crucial to reveal fundamental degradation modes of lithium-ion batteries (LIBs). Taking advantage of the sensitivity of neutrons to some low-Z (Li) and X-rays to high-Z materials (Cu), here we demonstrate the viability of simultaneous neutron and X-ray tomography (NeXT) as a non-destructive imaging platform for ex-situ 3D visualization of graphite electrode degradation following extreme fast charging (XFC). In addition, we underscore the benefits of the simultaneous of NeXT by combining the neutron and X-ray tomography data from the same sample location for material identification and segmentation of one pristine and two XFC-cycled graphite electrodes (9C charge for 450 cycles). Our ex-situ results and methodology development pave the way for the design of NeXT-friendly LIB geometries that will allow operando and/or in-situ 3D visualization of electrode degradation during XFC.

25 ENERGY STORAGE↗

Demonstration of Non-linear Optical Spectroscopy Enhancement utilizing Entangled Photons

Laser-based nonlinear optical spectroscopy approaches have enabled the direct sensing of important chemistry in nearly every fundamental or applied field of science. Yet in many applications, increased detectivity is needed to unravel fundamental mechanisms. One possibility is the use of quantum entanglement to increase detection cross-sections, but it is unproven that enhancement from quantum light extends to practical intensities for chemical sensing. In this report, we investigated the creation and use of entangled photons in nonlinear optical mixing for second harmonic generation and infrared imaging. We observe that the linear scaling of nonlinear mixing from entangled photon sources extends to the mW laser power regime, and enhances direct infrared imaging on Si-based charge coupled device cameras. These results motivate future experimentation on practical uses of entangled photons for nonlinear optical sensing applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy and Resolution Evaluation of the E-Beam Profile Scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Bevalac calibration of the SOFIE range and hodoscope detectors

The scintillating optical fiber isotope experiment (SOFIE) is a Cerenkov-dE/dx-Range experiment which was developed initially for balloon flight to study the isotopic composition of cosmic rays in the iron region. The electronic range and hodoscope detectors use scintillating optical fibers to image the tracks of stopping charged particles and to determine their trajectory. The particle range is determined and used together with a Cerenkov measurement to determine the mass of the stopping particle. Preliminary results of a Bevalac calibration performed in August, 1984 with a prototype of the balloon flight instrument, to study the measurement precision in range and trajectory which could be attained with this detector are described.

Binns, W. R.↗

Evaluation of selected detector arrays for space applications

The development of a high density Schottky barrier Infrared Charged Coupled Device (IRCCD) type image sensor for earth observation was initiated. A dual band 512 pixel linear array was developed, which was capable of being butted end to end to make an arbitrarily long linear array. Measurement made on palladium silicide IRCCDs that were two-dimensional 63 x 32 pixel arrays were summarized. The test data on a 512 pixel linear array is also summarized.

Lowrance, J. L.↗

Imaging Spectrometer With Liquid-Crystal Tunable Filter

Imaging spectrometer constructed from charged-coupled-device video camera; liquid-crystal tunable filter (LCTF) placed in front of camera lens; and associated digital and analog control, signal-processing, and data-processing circuits. To enable operation of instrument in specific application for which designed (balloon flights in cold weather), camera and LCTF surrounded by electric heating pad. Total operating power, excluding that consumed by heating pad, 16 W. Instrument weighs 4.5 kg.

Chrien, Thomas G.↗

Observed On-Orbit Background of the ACIS Detector on the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic X-rays. The ACIS instrument contains 8 Front-Illuminated (FI) CCDs and 2 Back-Illuminated (BI) CCDs. The FI and BI CCD)s exhibit dramatically different responses to enhancements in the particle flux. The F1 CCDs show relatively little increase in the overall count rate, typical increases are 1 - 3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The duration of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the power-law. The events produce morphologies which are similar to cosmic X-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, P. P.↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

Sensitive, Rapid Detection of Bacterial Spores

A method of sensitive detection of bacterial spores within delays of no more than a few hours has been developed to provide an alternative to a prior three-day NASA standard culture-based assay. A capability for relatively rapid detection of bacterial spores would be beneficial for many endeavors, a few examples being agriculture, medicine, public health, defense against biowarfare, water supply, sanitation, hygiene, and the food-packaging and medical-equipment industries. The method involves the use of a commercial rapid microbial detection system (RMDS) that utilizes a combination of membrane filtration, adenosine triphosphate (ATP) bioluminescence chemistry, and analysis of luminescence images detected by a charge-coupled-device camera. This RMDS has been demonstrated to be highly sensitive in enumerating microbes (it can detect as little as one colony-forming unit per sample) and has been found to yield data in excellent correlation with those of culture-based methods. What makes the present method necessary is that the specific RMDS and the original protocols for its use are not designed for discriminating between bacterial spores and other microbes. In this method, a heat-shock procedure is added prior to an incubation procedure that is specified in the original RMDS protocols. In this heat-shock procedure (which was also described in a prior NASA Tech Briefs article on enumerating sporeforming bacteria), a sample is exposed to a temperature of 80 C for 15 minutes. Spores can survive the heat shock, but nonspore- forming bacteria and spore-forming bacteria that are not in spore form cannot survive. Therefore, any colonies that grow during incubation after the heat shock are deemed to have originated as spores.

Kern, Roger G.↗

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Near-infrared Reflectance of Rocks at high Temperature: Preliminary Results and Implications for Near-infrared Emissivity of Venus's Surface

Light emitted from Venus’s surface can be viewed through spectral “windows” in its atmosphere, in the nearinfrared (NIR) around 1000 nanometer (nm) wavelengths. The NIR emissivity of Venus’s surface can constrain rock types and their weathering state; emissivities can be measured directly or calculated from reflectances. We measured the reflectances of igneous and sedimentary rocks at Venus’s surface temperature, 400 °C–500 °C at 850 and 950 nm; samples were heated in a box furnace in air, illuminated by light-emitting diodes (LEDs), and imaged with a modified charge-coupled device (CCD) camera. Reflectances were also measured at 25 °C from 350 to 1400 nm. Rock reflectances at 850 and 950 nm and 400 °C–500 °C are nearly identical to those at 25 °C, except for the effects of nanophase hematite forming on some surfaces. Fresh basalts have reflectances (high and low temperatures) near 7.5%; a leucogranite similarly has reflectances near 50%. Pigmentary hematite has nearly identical reflectances at high- and low-temperature at these wavelengths. Pigmentary hematite appears dark brown 400 °C–500 °C because its absorption edge has shifted to beyond the limit of human vision. These rock reflectances imply that basalts should have emissivities near 0.9, and granite (and similar felsic rocks) should have lower emissivities ∼0.5. Thus, basalt and felsic rock should be easily distinguished in NIR emissivity measurements of Venus’s surface, such as are baselined in recent Venus mission proposals. Other sedimentary rocks should have even lower emissivities: quartz sand at around ∼0.3, and anhydrite as low as 0.1.

Allan H Treiman↗

Monitoring Both Sides Of A Weld In Progress

Proposed remote vision system provides simultaneous viewing of front and back of workpiece while being welded. Enables human or automatic controller to monitor both weld pool on front and weld penetration on back. Nitrogen laser generates ultraviolet light, distributed to both sides of workpiece through two optical fiber cables. Image-intensifier tubes convert reflected ultraviolet light to visible light. Video cameras equipped with high-resolution charge-coupled devices convert visible outputs of image intensifiers into images for viewing on video monitors.

Dickinson, C. B.↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗