Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Investigation of cooling properties of the gaseous medium of a space station

An investigation of cooling properties of the gaseous medium was performed in the biosatellite Kosmos-936 as well as in the orbital complexes Soyuz-28/Salyut-6 and Soyuz-30/Salyut-6 with the aid of an especially constructed electric dynamic catathermometer. In this instrument current was measured which was necessary to keep a steady settled temperature of the sensing device. The investigation was performed because of the disturbed heat exhange of the human body caused by lack of natural convection in weightlessness. The instrument also enabled objective estimation of the temperature of the cosmonaut's ody in six optionally selected regions. The results obtained by means of the catathermometer will also enable defining the appropriate hygienic conditions of the gaseous medium of space stations.

Baranski, S.↗

Mars Environmental Survey (MESUR): Science objectives and mission description

In-situ observations and measurements of Mars are objectives of a feasibility study beginning at the Ames Research Center for a mission called the Mars Environmental SURvey (MESUR). The purpose of the MESUR mission is to emplace a pole-to-pole global distribution of landers on the Martian surface to make both short- and long-term observations of the atmosphere and surface. The basic concept is to deploy probes which would directly enter the Mars atmosphere, provide measurements of the upper atmospheric structure, image the local terrain before landing, and survive landing to perform meteorology, seismology, surface imaging, and soil chemistry measurements. MESUR is intended to be a relatively low-cost mission to advance both Mars science and human presence objectives. Mission philosophy is to: (1) 'grow' a network over a period of years using a series of launch opportunities, thereby minimizing the peak annual costs; (2) develop a level-of-effort which is flexible and responsive to a broad set of objectives; (3) focus on science while providing a solid basis for human exploration; and (4) minimize project cost and complexity wherever possible. In order to meet the diverse scientific objectives, each MESUR lander will carry the following strawman instrument payload consisting of: (1) Atmospheric structure experiment, (2) Descent and surface imagers, (3) Meteorology package, (4) Elemental composition instrument, (5) 3-axis seismometer, and (6) Thermal analyzer/evolved gas analyzer. The feasibility study is primarily to show a practical way to design an early capability for characterizing Mars' surface and atmospheric environment on a global scale. The goals are to answer some of the most urgent questions to advance significantly our scientific knowledge about Mars, and for planning eventual exploration of the planet by robots and humans.

Hubbard, G. Scott↗

A PARC system for terminal docking

A Panoramic viewing system for Automated Rendezvous and Capture (PARC) has been proposed as a visual information feedback system for terminal docking/berthing. The system relies on a unique Panoramic Annular Lens (PAL) which captures an image of its surroundings in real time. This paper describes the evolution of the PAL along with technical details of its imaging capabilities. Several examples are given of radial metrology, where PAL imaging systems are used to perform visual inspections and measurements. Digital image acquisition and processing techniques, used to interpret various features appearing in the images and to transform images for improved human viewing, are also included. These discussions are followed by a potential application for PARC involving berthing of active and passive mechanical assemblies associated with Space Station Freedom.

Gilbert, John A.↗

Mobile Instruments Measure Atmospheric Pollutants

As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

Source record↗

SDBI 1904: Human Factors Assessment of Vibration Effects on Visual Performance during Launch

The primary objective of the of Human Factors Short Duration Bioastronautics Investigation (SDBI) 1904 is to determine visual performance limits during operational vibration and g-loads, specifically through the determination of minimal usable font sizes using Orion-type display formats. Currently there is little to no data available to quantify human visual performance under these extreme conditions. Existing data on shuttle vibration magnitude and frequency is incomplete, does not address seat and crew vibration in the current configuration, and does not address human visual performance. There have been anecdotal reports of performance decrements from shuttle crews, but no structured data has been collected. The SDBI is a companion effort to the Detailed Test Objective (DTO) 695, which will measure shuttle seat accelerations (vibration) during ascent. Data from the SDBI will serve an important role in interpreting the DTO vibration data. This data will be collected during the ascent phase of three shuttle missions (STS-119, 127, and 128). Both SDBI1904 and DTO 695 are low impact with respect to flight resources, and combined they represent an efficient and focused problem solving approach. The SDBI and DTO data will be correlated to determine the nature of perceived visual performance under varying vibrations and g-loads. This project will provide: * Immediate data for developing preliminary human performance vibration requirements * Flight validated inputs for ongoing and future ground-based research * Information of functional needs that will drive Orion display format design decisions

Shelby G Thompson↗

Population Physiologically-Based Pharmacokinetic Modeling for the Human Lactational Transfer of PCB 153 with Consideration of Worldwide Human Biomonitoring Results

We developed a physiologically based pharmacokinetic model of PCB 153 in women, and predict its transfer via lactation to infants. The model is the first human, population-scale lactational model for PCB 153. Data in the literature provided estimates for model development and for performance assessment. Physiological parameters were taken from a cohort in Taiwan and from reference values in the literature. We estimated partition coefficients based on chemical structure and the lipid content in various body tissues. Using exposure data in Japan, we predicted acquired body burden of PCB 153 at an average childbearing age of 25 years and compare predictions to measurements from studies in multiple countries. Forward-model predictions agree well with human biomonitoring measurements, as represented by summary statistics and uncertainty estimates. The model successfully describes the range of possible PCB 153 dispositions in maternal milk, suggesting a promising option for back estimating doses for various populations. One example of reverse dosimetry modeling was attempted using our PBPK model for possible exposure scenarios in Canadian Inuits who had the highest level of PCB 153 in their milk in the world.

54 ENVIRONMENTAL SCIENCES↗

Disentangling Electronic Transport and Hysteresis at Individual Grain Boundaries in Hybrid Perovskites via Automated Scanning Probe Microscopy

Underlying the rapidly increasing photovoltaic efficiency and stability of metal halide perovskites (MHPs) is the advancement in the understanding of the microstructure of polycrystalline MHP thin film. Over the past decade, intense efforts have been aimed at understanding the effect of microstructures on MHP properties, including chemical heterogeneity, strain disorder, phase impurity, etc. It has been found that grain and grain boundary (GB) are tightly related to lots of microscale and nanoscale behavior in MHP thin films. Atomic force microscopy (AFM) is widely used to observe grain and boundary structures in topography and subsequently to study the correlative surface potential and conductivity of these structures. For now, most AFM measurements have been performed in imaging mode to study the static behavior; in contrast, AFM spectroscopy mode allows us to investigate the dynamic behavior of materials, e.g., conductivity under sweeping voltage. However, a major limitation of AFM spectroscopy measurements is that they require manual operation by human operators, and as such only limited data can be obtained, hindering systematic investigations of these microstructures. Here, we designed a workflow combining the conductive AFM measurement with a machine learning (ML) algorithm to systematically investigate grain boundaries in MHPs. The trained ML model can extract GBs locations from the topography image, and the workflow drives the AFM probe to each GB location to perform a current–voltage (IV) curve automatically. Then, we are able to have IV curves at all GB locations, allowing us to systematically understand the property of GBs. Using this method, we discovered that the GB junction points are less conductive, potentially more photoactive, and can play critical roles in MHP stability, while most previous works only focused on the difference between GB and grains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extinction and visibility measurements in the lower atmosphere with UV-YAG-lidar

With the intention to investigate methods for slant path visibiltiy measurements and to develop information for modelling of extinction profiles in the atmospheric boundary layer, measurements were performed with a lidar based on a YAG-laser. The third harmonic at 355 nm in the ultraviolet was used and thus eye safety problems are avoided. At this wavelength the lens of the human eye is not transparent and the safety distance for the laser is a 50 meters as compared to several km for a corresponding green laser. The lidar is a coaxial system with a turnable mirror system for beam steering. The extinction coefficient at both 355 and 532 nm was measured and the ratio determined. Provided that the wavelength dependence of the aerosol extinction is range independent, the measured extinction profile at 355 nm can be converted to a corresponding profile at 532 nm, which is more relevant for visibility. In order to calculate the extinction profile the lidar equation is inverted by a method, which is based on Klett's method.

Hagard, A.↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Critical mission tasks required by crews immediately after landing on a planetary surface include walking, jumping, and egressing from a seat. Understanding how these functional tasks are performed in partial gravity such as on the moon or Mars is necessary to define effective and comprehensive countermeasure strategies for preserving crew performance during exploration-class missions. We propose to study the performance of these tasks during the partial gravity phases of parabolic flight. These tasks will be performed using the same equipment and procedures as those used with astronauts returning from spaceflight and with ground-based subjects after prolonged axial body unloading during bed rest (sensorimotor standard measures). HYPOTHESIS We hypothesize that partial gravity during parabolic flight will cause acute changes in vestibular, proprioceptive, and sensorimotor functions, and these changes will impact the performance of mission critical tasks such as standing, walking, and jumping. The largest changes in performance are expected at the lowest gravity level (0.25g) because subjects will no longer be able to use the gravitational reference for the perception of upright. Ultimately, this information could be used to assess performance risks and inform the design of countermeasures for NASA exploration-class human missions. METHODS Twelve subjects will be tested during three flights of 30 parabolas, including 10 parabolas at 0.25g, 10 parabolas at 0.5g, and 10 parabolas at 0.75g. Subjects also will perform tests in 1g between parabolas. The tasks will be the same as those tested on astronauts returning from spaceflight: sit-to-stand with obstacle walk, tandem rail balance, jump down, and recovery from fall. Measurements will include: (a) time to test completion (sit-to-stand with obstacle walk, recovery from fall); (b) time elapsed between the start of motion and the stabilization of upright posture (recovery from fall, jump down); (c) mean sway speed during quiet standing (recovery from fall, jump down); (d) changes in heart rate and blood pressure (recovery from fall); (e) balance time and torso accelerations (tandem rail balance); (f) cone of stability (jump down); and (g) severity of motion sickness symptoms. RELEVANCE Although gravitational dose-response curves have been obtained for some biochemical systems in animals, these dose-responses are unknown for most human physiologic systems. Our study will compare the outcomes of four functional task tests in 0.25g, 0.5g, 0.75g, and 1g with those previously obtained in ground-based subjects after prolonged axial body unloading and in astronauts immediately after spaceflight. These comparisons will help us understand the true extent of functional task performance deficits in partial gravity. The dose-response relationship between gravity level and task performance decrement also will help determining the gravity threshold for these functional tasks. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element.

T. R. Macaulay↗

Subtask 4.8 - Fate and Control of Mercury and Trace Elements

The Center for Air Toxic Metals® (CATM®) Program at the Energy & Environmental Research Center (EERC) continues to focus on vital basic and applied research related to the fate, behavior, measurement, and control of trace metals, especially mercury, and the impact that these trace metals have on human health and the environment. For years, the CATM Program has maintained an international perspective, performing research and providing results that apply to both domestic and international audiences, with reports distributed in the United States and abroad. In addition to trace metals, CATM’s research focuses on other related emissions and issues that impact trace metal releases to the environment, such as SO x , NO x , CO 2 , ash, and wastewater streams. Of paramount interest and focus has been performing research that continues to enable the power and industrial sectors to operate in an environmentally responsible manner to meet regulatory standards. The research funded by the U.S. Department of Energy’s (DOE’s) National Energy Technology Laboratory (NETL) through CATM has allowed significant strides to be made to gain a better understanding of trace metals and other emissions, improve sampling and measurement techniques, fill data gaps, address emerging technical issues, and develop/test control technologies that allow industry to cost-effectively meet regulatory standards. The DOE NETL–CATM research specifically focused on the fate and control of mercury and trace elements in power systems that use CO 2 control technologies, such as oxycombustion and gasification systems, which are expected to be among those technologies that will be used to address climate change issues. In addition, research addressed data gaps for systems that use conventional and multipollutant control technologies, such as electrostatic precipitators, selective catalytic reduction units, flue gas desulfurization systems, and flue gas-conditioning methods, to understand mercury interactions, develop better control strategies and, in some cases, prevent mercury from being reemitted. This research also addressed stakeholder concerns and questions related to sampling and analytical methods for mercury, especially for continuous mercury monitors and sorbent trap methods for future compliance. Advancements were made toward the development of a much simpler dry-based method for measurement of halogens and trace metals. Finally, this research resulted in significant outcomes related to mercury and selenium concentrations in freshwater fish and how it is associated with other elements, thereby potentially impacting health; this has greatly enhanced the understanding of the second-order mechanism of mercury toxicity. The outcomes of this research have been shared with stakeholders in various domestic and international forums, working groups, conferences, educational settings, and published documents, with information available and accessible to those most impacted or interested in timely and current results on toxic metals. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291.

54 ENVIRONMENTAL SCIENCES↗

SU-F-I-27: Measurement of SAR and Temperature Elevation During MRI Scans

Purpose: The poor reliability and repeatability of the manufacturer-reported SAR values on clinical MRI systems have been acknowledged. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation at 1.5 and 3T MRI systems. Methods: SAR measurement experiment was performed at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T1w inversion recovery, and T2w TSE) with imaging parameters were selected. A hydroxyl-ethylcelluose (HEC) gelled saline phantom mimicking human body tissue was made. Human torso phantom were constructed, based on Korean adult standard anthropometric reference data (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located inside the phantom. 55 Fiber Bragg Grating (FBG) temperature sensors (27 sensors in upper and lower cover lids, and one sensor located in the center as a reference) were located inside the phantom to measure temperature change during MRI scan (Fig.2). Results: Simulation shows that SAR value is 0.4 W/kg in the periphery and 0.001 W/kg in the center (Fig.2). One 1.5T and one of two 3T MRI systems represent that the measured SAR values were lower than MRI scanner-reported SAR values. However, the other 3T MRI scanner shows that the averaged SAR values measured by probe 2, 3, and 4 are 6.83, 7.59, and 6.01 W/kg, compared to MRI scanner-reported whole body SAR value (<1.5 W/kg) for T2w TSE (Table 1). The temperature elevation measured by FBG sensors is 5.2°C in the lateral shoulder, 5.1°C in the underarm, 4.7°C in the anterior axilla, 4.8°C in the posterior axilla, and 4.8°C in the lateral waist for T2w TSE (Fig.3). Conclusion: It is essential to assess the safety of MRI system for patient by measuring accurate SAR deposited in the body during clinical MRI.

60 APPLIED LIFE SCIENCES↗

Experimental Evaluation of Electric Power Grid Visualization Tools in the EIOC

The present study follows an initial human factors evaluation of four electric power grid visualization tools and reports on an empirical evaluation of two of the four tools: Graphical Contingency Analysis, and Phasor State Estimator. The evaluation was conducted within specific experimental studies designed to measure the impact on decision making performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Role of S100A12 in the pathogenesis of osteoarthritis

Highlights: Black-Right-Pointing-Pointer This is the first report of S100A12 expression in human OA articular cartilages. Black-Right-Pointing-Pointer Exogenous S100A12 increased the production of MMP13 and VEGF in OA chondrocytes. Black-Right-Pointing-Pointer Soluble RAGE suppressed the increased production of MMP13 and VEGF. Black-Right-Pointing-Pointer p38MAPK and NF-{kappa}B inhibitors abrogated S100A12-induced MMP13 and VEGF production. Black-Right-Pointing-Pointer S100A12 may contribute to OA progression by increasing MMP13 and VEGF production. -- Abstract: S100A12 is a member of the S100 protein family, which are intracellular calcium-binding proteins. Although there are many reports on the involvement of S100A12 in inflammatory diseases, its presence in osteoarthritic cartilage has not been reported. The purpose of this study was to investigate the expression of S100A12 in human articular cartilage in osteoarthritis (OA) and to evaluate the role of S100A12 in human OA chondrocytes. We analyzed S100A12 expression by immunohistochemical staining of cartilage samples obtained from OA and non-OA patients. In addition, chondrocytes were isolated from knee cartilage of OA patients and treated with recombinant human S100A12. Real-time RT-PCR was performed to analyze mRNA expression. Protein production of matrix metalloproteinase 13 (MMP-13) and vascular endothelial growth factor (VEGF) in the culture medium were measured by ELISA. Immunohistochemical analyses revealed that S100A12 expression was markedly increased in OA cartilages. Protein production and mRNA expression of MMP-13 and VEGF in cultured OA chondrocytes were significantly increased by treatment with exogenous S100A12. These increases in mRNA expression and protein production were suppressed by administration of soluble receptor for advanced glycation end products (RAGE). Both p38 mitogen-activated protein kinase (MAPK) and nuclear factor-{kappa}B (NF-{kappa}B) inhibitors also suppressed the increases in mRNA expression and protein production of MMP-13 and VEGF. We demonstrated marked up-regulation of S100A12 expression in human OA cartilages. Exogenous S100A12 increased the production of MMP-13 and VEGF in human OA chondrocytes. Our data indicate the possible involvement of S100A12 in the development of OA by up-regulating MMP-13 and VEGF via p38 MAPK and NF-{kappa}B pathways.

60 APPLIED LIFE SCIENCES↗

Kalman-filtered compressive sensing for high resolution estimation of anthropogenic greenhouse gas emissions from sparse measurements.

The estimation of fossil-fuel CO2 emissions (ffCO2) from limited ground-based and satellite measurements of CO2 concentrations will form a key component of the monitoring of treaties aimed at the abatement of greenhouse gas emissions. The limited nature of the measured data leads to a severely-underdetermined estimation problem. If the estimation is performed at fine spatial resolutions, it can also be computationally expensive. In order to enable such estimations, advances are needed in the spatial representation of ffCO2 emissions, scalable inversion algorithms and the identification of observables to measure. To that end, we investigate parsimonious spatial parameterizations of ffCO2 emissions which can be used in atmospheric inversions. We devise and test three random field models, based on wavelets, Gaussian kernels and covariance structures derived from easily-observed proxies of human activity. In doing so, we constructed a novel inversion algorithm, based on compressive sensing and sparse reconstruction, to perform the estimation. We also address scalable ensemble Kalman filters as an inversion mechanism and quantify the impact of Gaussian assumptions inherent in them. We find that the assumption does not impact the estimates of mean ffCO2 source strengths appreciably, but a comparison with Markov chain Monte Carlo estimates show significant differences in the variance of the source strengths. Finally, we study if the very different spatial natures of biogenic and ffCO2 emissions can be used to estimate them, in a disaggregated fashion, solely from CO2 concentration measurements, without extra information from products of incomplete combustion e.g., CO. We find that this is possible during the winter months, though the errors can be as large as 50%.

Ray, Jaideep↗

Performance Assessment for the Waste Management Area C at the Hanford Site in Southeast Washington - 17515

An initial performance assessment (PA) of Single-Shell Tank (SST) Waste Management Area C (WMA C) located at the U.S. Department of Energy's (DOE) Hanford Site in southeastern Washington has been completed to satisfy the requirements of the Hanford Federal Facility Agreement and Consent Order (HFFACO), as well as other Federal requirements and State-approved closure plans and permits. The WMA C PA assesses the fate, transport, and impacts of radionuclides within residual wastes left in tanks and ancillary equipment and facilities in their assumed closed configuration, and the subsequent risks to humans into the far future. This PA focused on radiological impacts has been developed to meet the requirements for a closure authorization under DOE O 435.1 that includes a waste incidental to reprocessing determination for residual wastes remaining in tanks, ancillary equipment, and facilities. PA results indicate that the performance objectives and measures for the all-pathways dose, the air pathway dose, the radon flux, and groundwater protection are met for both the 1,000-year compliance time period (2020 to 3020) and the post-compliance period (3020 to 12020). The peak dose for the all-pathways analysis in the 1,000-year compliance period is associated with the air pathway, with the peak dose of 4 x 10{sup -5} mSv/yr dominated by tritium resulting from upward gaseous diffusive flux from the residual waste. The peak dose within the sensitivity/uncertainty analysis time period (1,000 to 10,000 years after closure) occurs at about 1,500 years after closure, and results primarily from a peak in {sup 99}Tc groundwater concentration at 100 m down-gradient of the facility. The peak total dose within the sensitivity/uncertainty analysis time period is 0.001 mSv/yr. For all of the sensitivity analyses and uncertainty analyses evaluated, the disposal system also met the performance objectives. In the uncertainty analysis performed with the system level model based on GoldSim{sup C}, the highest calculated groundwater dose in the compliance period was about 7 x 10{sup -4} mSv/yr, and the highest calculated peak dose in the sensitivity/uncertainty analysis period was 0.025 mSv/yr.Doses associated with hypothetical inadvertent human intrusion were calculated for all sources in WMA C and compared to the acute and chronic performance measures in DOE O 435.1. The calculated doses for acute and chronic exposure scenario from potential intrusion into a waste transfer pipeline remain below the DOE O 435.1 performance measure for the time period evaluated beyond 100 years after closure. Acute exposure from drilling into the waste yielded a dose of about 0.36 mSv after the assumed 100-year institutional control period, well below the 5 mSv performance measure for acute exposure. Chronic exposure to waste from drill cuttings in a rural pasture scenario resulted in a dose of about 0.08 mSv/yr after the assumed 100-year institutional control period, well below the 1 mSv/yr performance measure for chronic exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding the Impact of User Frustration Intensities on Task Performance Using the OCC Theory of Emotions

Have you heard the saying "frustration is written all over your falce"? Well this saying is true, but that is not the only place. Frustration is written all over your face and your body. The human body has various means to communicate an emotion without the utterance of a single word. The Media Equation says that people interact with computers as if they are human: this includes experiencing frustration. This research measures frustration by monitoring human body-based measures such as heart rate, posture, skin temperature. and respiration. The OCC Theory of Emotions is used to separate frustration into different levels or intensities. The results of this study showed that individual intensities of frustration exist, so that task performance is not degraded. Results from this study can be used by usability testers to model how much frustration is needed before task performance measures start to decrease.

Washington, Gloria↗

2,3,7,8-Tetrachlorodibenzo-p-dioxin increases reactive oxygen species production in human endothelial cells via induction of cytochrome P4501A1

Studies in our laboratory have demonstrated that subchronic 2,3,7,8,-tetrachlorodibenzo-p-dioxin (TCDD) exposure of adult mice results in hypertension, cardiac hypertrophy, and reduced nitric oxide (NO)-mediated vasodilation. Moreover, increased superoxide anion production was observed in cardiovascular organs of TCDD-exposed mice and this increase contributed to the reduced NO-mediated vasodilation. Since cytochrome P4501A1 (CYP1A1) can contribute to some TCDD-induced toxicity, we tested the hypothesis that TCDD increases reactive oxygen species (ROS) in endothelial cells by the induction of CYP1A1. A concentration-response to 24 h TCDD exposure (10 pM-10 nM) was performed in confluent primary human aortic endothelial cells (HAECs). Oxidant-sensitive fluorescent probes dihydroethidium (DHE) and 2',7'-dichlorofluorescin diacetate (DCFH-DA), were used to measure superoxide anion, and hydrogen peroxide and hydroxyl radical, respectively. NO was also measured using the fluorescent probe diaminofluorescein-2 diacetate (DAF-2DA). These assessments were conducted in HAECs transfected with siRNA targeting the aryl hydrocarbon receptor (AhR), CYP1A1, or CYP1B1. TCDD concentration-dependently increased CYP1A1 and CYP1B1 mRNA, protein, and enzyme activity. Moreover, 1 nM TCDD maximally increased DHE (Cont = 1.0 +- 0.3; TCDD = 5.1 +- 1.0; p = 0.002) and DCFH-DA (Cont = 1.0 +- 0.2; TCDD = 4.1 +- 0.5; p = 0.002) fluorescence and maximally decreased DAF-2DA fluorescence (Cont = 1.0 +- 0.4; TCDD = 0.68 +- 0.1). siRNA targeting AhR and CYP1A1 significantly decreased TCDD-induced DHE (siAhR: Cont = 1.0 +- 0.1; TCDD = 1.3 +- 0.2; p = 0.093) (siCYP1A1: Cont = 1.0 +- 0.1; TCDD = 1.1 +- 0.1; p = 0.454) and DCFH-DA (siAhR: Cont = 1.0 +- 0.2; TCDD = 1.3 +- 0.3; p = 0.370) (siCYP1A1: Cont = 1.0 +- 0.1; TCDD = 1.3 +- 0.2; p = 0.114) fluorescence and increased DAF-2DA fluorescence (siAhR: Cont = 1.00 +- 0.03; TCDD = 0.97 +- 0.03; p = 0.481) (siCYP1A1: Cont = 1.00 +- 0.03; TCDD = 0.92 +- 0.03; p = 0.034), while siRNA targeting CYP1B1 did not. These data suggest that TCDD-induced increase in ROS is AhR-dependent and may be mediated, in part, by CYP1A1 induction.

60 APPLIED LIFE SCIENCES↗