Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Data Analytics for SAR

We assess the ability of variants of anomalous change detection (ACD) to identify human activity associated with large outdoor music festivals as they are seen from synthetic aperture radar (SAR) imagery collected by the Sentinel-1 satellite constellation. We found that, with appropriate feature vectors, ACD using random-forest machine learning was most effective at identifying changes associated with the human activity.

47 OTHER INSTRUMENTATION↗

Report on PTT Imaging of Defects in AM Metallic Materials-Part 2

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study.

36 MATERIALS SCIENCE↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

Cardiotachometer with linear beat-to-beat frequency response

Cardiotachometer detects and displays the human heart rate during physiological studies. It provides linear response to the heart rate, records heart rate during rest and under heavy stress, provides a beat-to-beat indication of changes in heart rate, and is relatively free of interfering signals from activities other than the heart rate.

Deboo, G. J.↗

Phytochrome-mediated responses: Implications for controlled environment research facilities

Light is undoubtedly the most important environmental variable for plant growth and development; plants not only use radiant energy in photosynthesis, they also respond to the quantity, quality, direction and timing of incident radiation through photomorphogenic response that can have huge effects on the rate of growth and the pattern of development. It is surprising, therefore, that the manufacturers and suppliers of controlled environment facilities have been singularly uninventive in the design of the lighting assemblies they provide. The consumer has one choice only - a lighting assembly that provides irradiance levels usually only a fraction of sunlight, and a control system that is limited to regulating the timing of the on-off switch. The reasons for these limitations are partly technological, but in the main they result from ignorance on the part of both the consumer and the manufacturer. A specific and powerful example of this ignorance relates to the importance of the so-called far-red wavelengths (FR = 700-800 nm). Because the human eye can hardly detect wavelengths above 700 nm, and photosynthesis also cuts off at about 700 nm, the majority of plant and crop physiologists are still almost completely unaware that FR radiation can have massive effects on growth rate and development. In consequence, most growth cabinets have light sources based on fluorescent tubes, and provide very little FR apart from that emitted by a token number of small incandescent bulbs. Larger growth facilities often use broader spectrum light sources, but growth facilities that provide the capability to vary the FR incident upon the plants are about as abundant as seals in the Sahara. This article sets the background of the significance of FR radiation in the natural environment and its importance for plant growth and development in the hope that it might inform intelligently those concerned with improving the design of plant growth facilities.

Smith, Harry↗

Security in Full-Force

When fully developed for NASA, Vanguard Enforcer(TM) software-which emulates the activities of highly technical security system programmers, auditors, and administrators-was among the first intrusion detection programs to restrict human errors from affecting security, and to ensure the integrity of a computer's operating systems, as well as the protection of mission critical resources. Vanguard Enforcer was delivered in 1991 to Johnson Space Center and has been protecting systems and critical data there ever since. In August of 1999, NASA granted Vanguard exclusive rights to commercialize the Enforcer system for the private sector. In return, Vanguard continues to supply NASA with ongoing research, development, and support of Enforcer. The Vanguard Enforcer 4.2 is one of several surveillance technologies that make up the Vanguard Security Solutions line of products. Using a mainframe environment, Enforcer 4.2 achieves previously unattainable levels of automated security management.

Source record↗

Quantifying the performance limits of human saccadic targeting during visual search

In previous studies of saccadic targeting, the issue how visually guided saccades to unambiguous targets are programmed and executed has been examined. These studies have found different degrees of guidance for saccades depending on the task and task difficulty. In this study, we use ideal-observer analysis to estimate the visual information used for the first saccade during a search for a target disk in noise. We quantitatively compare the performance of the first saccadic decision to that of the ideal observer (ie absolute efficiency of the first saccade) and to that of the associated final perceptual decision at the end of the search (ie relative efficiency of the first saccade). Our results show, first, that at all levels of salience tested, the first saccade is based on visual information from the stimulus display, and its highest absolute efficiency is approximately 20%. Second, the efficiency of the first saccade is lower than that of the final perceptual decision after active search (with eye movements) and has a minimum relative efficiency of 19% at the lowest level of saliency investigated. Third, we found that requiring observers to maintain central fixation (no saccades allowed) decreased the absolute efficiency of their perceptual decision by up to a factor of two, but that the magnitude of this effect depended on target salience. Our results demonstrate that ideal-observer analysis can be extended to measure the visual information mediating saccadic target-selection decisions during visual search, which enables direct comparison of saccadic and perceptual efficiencies.

Non-NASA Center↗

Adjustably Autonomous Multi-agent Plan Execution with an Internal Spacecraft Free-Flying Robot Prototype

We present an multi-agent model-based autonomy architecture with monitoring, planning, diagnosis, and execution elements. We discuss an internal spacecraft free-flying robot prototype controlled by an implementation of this architecture and a ground test facility used for development. In addition, we discuss a simplified environment control life support system for the spacecraft domain also controlled by an implementation of this architecture. We discuss adjustable autonomy and how it applies to this architecture. We describe an interface that provides the user situation awareness of both autonomous systems and enables the user to dynamically edit the plans prior to and during execution as well as control these agents at various levels of autonomy. This interface also permits the agents to query the user or request the user to perform tasks to help achieve the commanded goals. We conclude by describing a scenario where these two agents and a human interact to cooperatively detect, diagnose and recover from a simulated spacecraft fault.

Dorais, Gregory A.↗

Using an Ultrasonic Instrument to Size Extravascular Bubbles

In an ongoing development project, microscopic bubbles in extravascular tissue in a human body will be detected by use of an enhanced version of the apparatus described in Ultrasonic Bubble- Sizing Instrument (MSC-22980), NASA Tech Briefs, Vol. 24, No. 10 (October 2000), page 62. To recapitulate: The physical basis of the instrument is the use of ultrasound to excite and measure the resonant behavior (oscillatory expansion and contraction) of bubbles. The resonant behavior is a function of the bubble diameter; the instrument exploits the diameter dependence of the resonance frequency and the general nonlinearity of the ultrasonic response of bubbles to detect bubbles and potentially measure their diameters. In the cited prior article, the application given most prominent mention was the measurement of gaseous emboli (essentially, gas bubbles in blood vessels) that cause decompression sickness and complications associated with cardiopulmonary surgery. According to the present proposal, the instrument capabilities would be extended to measure extravascular bubbles with diameters in the approximate range of 1 to 30 m. The proposed use of the instrument could contribute further to the understanding and prevention of decompression sickness: There is evidence that suggests that prebreathing oxygen greatly reduces the risk of decompression sickness by reducing the number of microscopic extravascular bubbles. By using the ultrasonic bubble-sizing instrument to detect and/or measure the sizes of such bubbles, it might be possible to predict the risk of decompression sickness. The instrument also has potential as a tool to guide the oxygen-prebreathing schedules of astronauts; high-altitude aviators; individuals who undertake high-altitude, low-opening (HALO) parachute jumps; and others at risk of decompression sickness. For example, an individual at serious risk of decompression sickness because of high concentrations of extravascular microscopic bubbles could be given a warning to continue to prebreathe oxygen until it was safe to decompress.

Magari, Patrick J.↗

Multi-Parameter Aerosol Scattering Sensor

This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration

Greenberg, Paul S.↗

Microgravity Science Glovebox (MSG) Space Science's Past, Present, and Future on the International Space Station (ISS)

The Microgravity Science Glovebox (MSG) is a double rack facility designed for microgravity investigation handling aboard the International Space Station (ISS). The unique design of the facility allows it to accommodate science and technology investigations in a "workbench" type environment. MSG facility provides an enclosed working area for investigation manipulation and observation in the ISS. Provides two levels of containment via physical barrier, negative pressure, and air filtration. The MSG team and facilities provide quick access to space for exploratory and National Lab type investigations to gain an understanding of the role of gravity in the physics associated research areas. The MSG is a very versatile and capable research facility on the ISS. The Microgravity Science Glovebox (MSG) on the International Space Station (ISS) has been used for a large body or research in material science, heat transfer, crystal growth, life sciences, smoke detection, combustion, plant growth, human health, and technology demonstration. MSG is an ideal platform for gravity-dependent phenomena related research. Moreover, the MSG provides engineers and scientists a platform for research in an environment similar to the one that spacecraft and crew members will actually experience during space travel and exploration. The MSG facility is ideally suited to provide quick, relatively inexpensive access to space for National Lab type investigations.

Spivey, Reggie A.↗

In-Flight Microbial Monitor

Previous research has shown that potential human pathogens have been detected on the International Space Station (ISS). New microorganisms are introduced with every exchange of crew and cargo. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e., ECLSS, environmental control and life support systems). Current microbial characterization methods require a culture-based enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of microorganisms. The culture-based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS samples requires that the microbes be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, inflight method of microbial detection, identification, and enumeration is needed. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.

Technology Portfolio System↗

UAS-NAS Project Demo - Mini HITL Week 2 Stats

The UAS-NAS Project demo will showcase recent research efforts to ensure the interoperability between proposed UAS detect and avoid (DAA) human machine interface requirements (developed within RTCA SC-228) and existing collision avoidance displays. Attendees will be able to view the current state of the art of the DAA pilot traffic, alerting and guidance displays integrated with Traffic advisory and Collision Avoidance (TCAS) II in the UAS-NAS Project's research UAS ground control station (developed in partnership with the Air Force Research Laboratory). In addition, attendees will have the opportunity to interact with the research UAS ground control station and "fly" encounters, using the DAA and TCAS II displays to avoid simulated aircraft. The display of the advisories will be hosted on a laptop with an external 30" monitor, running the Vigilant Spirit system. DAA advisories will be generated by the JADEM software tool, connected to the system via the LVC Gateway. A repeater of the primary flight display will be shown on a 55" monitor mounted on a stand at the back of the booth to show the pilot interaction to the passersby.

UAS↗

AIAA Aviation UAS DAA Demonstration-Mini HITL Week 2 Stats

The UAS-NAS Project demo will showcase recent research efforts to ensure the interoperability between proposed UAS detect and avoid (DAA) human machine interface requirements (developed within RTCA SC-228) and existing collision avoidance displays. Attendees will be able to view the current state of the art of the DAA pilot traffic, alerting and guidance displays integrated with Traffic advisory and Collision Avoidance (TCAS) II in the UAS-NAS Project's research UAS ground control station (developed in partnership with the Air Force Research Laboratory). In addition, attendees will have the opportunity to interact with the research UAS ground control station and "fly" encounters, using the DAA and TCAS II displays to avoid simulated aircraft. The display of the advisories will be hosted on a laptop with an external 30" monitor, running the Vigilant Spririt system. DAA advisories will be generated by the JADEM software tool, connected to the system via the LVC Gateway. A repeater of the primary flight display will be shown on a 55" tv/monitor mounted on a stand at the back of the booth to show the pilot interaction to the passersby.

UAS↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

Supporting Crew Medical Decisions on Deep Space Missions: A Real-Time Performance Monitoring

Crewed missions into deep space will require astronauts to respond autonomously to safety- and time-critical anomalies. These and other potential issues will require the continuous monitoring and recognition of potentially subtle, but complex, anomalous data patterns. NASA continues to investigate real-time metrics for Extravehicular Operations1 and for providing feedback to improve performance2. Since it is unknown how long-term exposure to deep space will affect crew health, continuous monitoring of clinical and subclinical status is warranted. NASA is characterizing crew medical decision-support needs and identifying the recommended requirements of a Clinical Decision Support System (CDSS) within the Exploration Medical Capability Element (ExMC) of the Human Research Program3. Early detection, and continuous monitoring, of performance may provide an effective prognostic capability for assessing crew health state, and the identified requirements could be provided for an in-vehicle CDSS that acts as an assistant for delivering optimal health and performance and medical care during exploration missions. There is evidence to suggest that automatic, unobtrusive collection of keystroke features, such as alphanumeric key latencies, backspaces or typing rhythm, could be a valuable performance screening tool. Keystroke features show significant differences between control subjects and patients with overt clinical illness, such as multiple sclerosis4 and Parkinson’s disease5, as well as behavioral health and performance issues, such as mild cognitive impairment6 and depression7. This work is exploring a capability for the assessment of early task performance decline in crew as they perform daily activities. Timestamped keyboard entries are continuously collected and stored. Nominal keystroke interactions are compared to those obtained after exposure to spaceflight stressors, e.g., fatigue, to determine the methods sensitivity. This work will pave the way toward an objective detection tool that may be deployed in a spaceflight setting.

clinical↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗