Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hot injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The bulk motion of gas in the core of the Centaurus galaxy cluster

Galaxy clusters contain vast amounts of hot ionized gas known as the intracluster medium (ICM). In relaxed cluster cores, the radiative cooling time of the ICM is shorter than the age of the cluster. However, the absence of line emission associated with cooling suggests heating mechanisms that offset the cooling, with feedback from active galactic nuclei (AGNs) being the most likely source. Turbulence and bulk motions, such as the oscillating (‘sloshing’) motion of the core gas in the cluster potential well, have also been proposed as mechanisms for heat distribution from the outside of the core. Here we present X-ray spectroscopic observations of the Centaurus galaxy cluster with the X-Ray Imaging and Spectroscopy Mission satellite. We find that the hot gas flows along the line of sight relative to the central galaxy, with velocities from 130 km s −1 to 310 km s −1 within about 30 kpc of the centre. This indicates bulk flow consistent with core gas sloshing. Although the bulk flow may prevent excessive accumulation of cooled gas at the centre, it could distribute the heat injected by the AGN and bring in thermal energy from the surrounding ICM. The velocity dispersion of the gas is found to be only ≲120 km s −1 in the core, even within about 10 kpc of the AGN. This suggests that the influence of the AGN on the surrounding ICM motion is limited in the cluster.

galaxies and clusters↗

Identification of Noise Sources During Rocket Engine Test Firings and a Rocket Launch Using a Microphone Phased-Array

A 70 microphone, 10-foot by 10-foot, microphone phased array was built for use in the harsh environment of rocket launches. The array was setup at NASA Wallops launch pad 0A during a static test firing of Orbital Sciences' Antares engines, and again during the first launch of the Antares vehicle. It was placed 400 feet away from the pad, and was hoisted on a scissor lift 40 feet above ground. The data sets provided unprecedented insight into rocket noise sources. The duct exit was found to be the primary source during the static test firing; the large amount of water injected beneath the nozzle exit and inside the plume duct quenched all other sources. The maps of the noise sources during launch were found to be time-dependent. As the engines came to full power and became louder, the primary source switched from the duct inlet to the duct exit. Further elevation of the vehicle caused spilling of the hot plume, resulting in a distributed noise map covering most of the pad. As the entire plume emerged from the duct, and the ondeck water system came to full power, the plume itself became the loudest noise source. These maps of the noise sources provide vital insight for optimization of sound suppression systems for future Antares launches.

acoustics↗

Tabulated Database of Closed-Loop Geothermal Systems Performance for Cloud-Based Technical and Economic Modeling of Heat Production and Electricity Generation: Preprint

To better understand the heat production, electricity generation performance and economic viability of closed loop geothermal systems in hot-dry-rock, the Closed Loop Geothermal Group, a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and super-critical CO2) while varying seven continuous independent parameters of interest (i.e., mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an Organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the TEA (techno-economic analysis) script are provided.

co-axial↗

Argon/UF6 plasma exhaust gas reconstitution experiments using preheated fluorine and on-line diagnostics

The feasibility of employing a flowing, high-temperature, pure fluorine/UF6 regeneration system to efficiently convert a large fraction of the effluent plasma exhaust back to pure UF6 was demonstrated. The custom built T.O.F. mass spectrometer sampling system permitted on-line measurements of the UF6 concentration at different locations in the exhaust system. Negligible amounts ( 100 ppm) of UF6 were detected in the axial bypass exhaust duct and the exhaust ducts downstream of the cryogenic trap system used to collect the UF6, thus verifying the overall system efficiency over a range of operating conditions. Use of a porous Monel duct as part of the exhaust duct system, including provision for injection of pure fluorine, provided a viable technique to eliminate uranium compound residue on the inside surface of the exhaust ducts. Typical uranium compound mass deposition per unit area of duct was 2 micron g/sq cm. This porous duct technique is directly applicable to future uranium compound transfer exhaust systems. Throughout these experiments, additional basic data on the corrosion aspects of hot, pressurized UF6/fluorine were also accumulated.

Roman, W. C.↗

Ultra-lean combustion at high inlet temperatures

Combustion at inlet air temperatures of 1100 to 1250 K was studied for application to advanced automotive gas turbine engines. Combustion was initiated by the hot environment, and therefore no external ignition source was used. Combustion was stabilized without a flameholder. The tests were performed in a 12 cm diameter test section at a pressure of 2.5 x 10 to the 5th power Pa, with reference velocities of 32 to 60 m/sec and at maximum combustion temperatures of 1350 to 1850 K. Number 2 diesel fuel was injected by means of a multiple source fuel injector. Unburned hydrocarbons emissions were negligible for all test conditions. Nitrogen oxides emissions were less than 1.9 g NO2/kg fuel for combustion temperatures below 1680 K. Carbon monoxide emissions were less than 16 g CO/kg fuel for combustion temperatures greater than 1600 K, inlet air temperatures higher than 1150 K, and residence times greater than 4.3 microseconds.

Anderson, D. N.↗

Effects of oscillating shock impingement on the mixing of a gaseous jet in a Mach 3 airstream

Oscillating shocks of different frequencies were impinged on a 15 deg downstream angled, sonic helium jet injected into a Mach 3 airflow. The oscillating shocks were produced by the normal injection of a steady liquid jet from an opposing wall into the Mach 3 airflow. The freestream Reynolds number per centimeter was 500,000 producing a boundary layer 1.6 times the helium injector diameter in thickness. Vertical helium concentration profiles were taken at nine transverse stations at an axial station 90 helium jet diameters downstream. Helium concentration was measured using an aspirating hot film probe with an integral thermocouple. Oscillating shock frequencies of 60 kHz, 120 kHz, and 240 kHz were studied, compared with the estimated frequencies of 60 kHz of the largest eddies in the approach boundary layer. Visualization using nanoshadowgraph photographs, showed large turbulent structures in all cases. In addition, there were clear changes in eddy size with changing frequency visible on the nanoshadowgraphs. Impingement of the oscillating shock upstream of the helium jet had no measurable effect on the mixing. Impingement downstream of the helium injector produced measurable changes in the mixing achieved. Increasing the frequency of the oscillating shock decreased the maximum concentration and the penetration height of the maximum concentration. There were additional measurable effects on the area of a typical concentration contour with increased oscillation frequency.

Thomas, R. H.↗

On the effect of pressure, oxygen concentration, air flow and gravity on simulated pool fires

The initial development of a fire is characterized by the establishment of a diffusion flame over the surface of a the condensed fuel and is particularly influenced by gravity, with most of the gaseous flow induced by natural convection. Low initial momentum of the fuel vapor, strong buoyant flows induced by the hot post-combustion gases and consequently low values of the Froude number (inertia-gravity forces ratio) are typical of this kind of scenario. An experimental study is conducted by using a porous burner to simulate the burning of a horizontal combustible surface. Ethane is used as fuel and different mixtures of oxygen and nitrogen as oxidizer. The magnitude of the fuel injection velocities is restricted to values that will keep the Froude number on the order of 10-5, when calculated at normal gravity and pressure, which are characteristic of condensed fuel burning. Two different burners are used, a circular burner (62 mm diameter) placed inside a cylindrical chamber (0.3 m diameter and 1.0 m height) and a rectangular burner (50 mm wide by 200 mm long) placed in a wind tunnel (350 mm long) of rectangular cross section (120 mm wide and 90 mm height). The first burner is used to study the effect of pressure and gravity in the absence of a forced flow parallel to the surface. The second burner is used to study the effect of a forced flow parallel to the burner surface as well as the effect of oxygen concentration in the oxidizer flow. In this case experiments are also conducted at different gravity levels (micro-gravity, 0.2 g(sub 0), g(sub 0) and 1.8 g(sub 0)) to quantify the relative importance of buoyancy.

Torero, J. L.↗

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗

Near-infrared mapping of spiral barred galaxies

In external galaxies, near-infrared emission originates from stellar populations, hot dust, free-free emission from H+ regions, gaseous emission, non-thermal nucleus if any. Because of the low extinction compared to the visible, infrared wavelengths are useful to probe regions obscured by dust such as central parts where starburst phenomena can occur because of the large quantity of matter. The results presented were obtained with a 32 x 32 InSb charge injection device (CID) array cooled at 4K, at the f/36 cassegrain focus of the 3m60 Canada-France-Hawaii telescope with a spatial resolution of 0.5 inches per pixel. The objects presented are spiral barred galaxies mapped at J(1.25 microns), H(1.65 microns) and K(2.2 microns). The non-axisymetric potential due to the presence of a bar induces dynamical processes leading to the confinement of matter and peculiar morphologies. Infrared imaging is used to study the link between various components. Correlations with other wavelengths ranges and 2-colors diagrams ((J-H), (H-K)) lead to the identification of star forming regions, nucleus. Maps show structures connected to the central core. The question is, are they flowing away or toward the nucleus. Observations of M83 lead to several conclusions. The star forming region, detected in the visible and the infrared cannot be very compact and must extend to the edge of the matter concentration. The general shape of the near-infrared emission and the location of radio and 10 micron peaks suggest the confinement of matter between the inner Linblad resonances localized from CO measurements about 100 and 400 pc. The distribution of color indices in the arc from southern part to the star forming region suggests an increasing amount of gas and a time evolution eventually triggered by supernova explosions. Close to the direction of the bar, a bridge-like structure connects the arc to the nucleus with peculiar color indices. Perhaps, this structure can be linked to a height velocity component seen in UV and we can attribute it to a jet and/or a matter flow along the bar toward the nucleus, fuelling it. NGC 1068 is the nearest Seyfert 2 galaxy. It has been a subject of many studies at all wavelengths. This object was mapped at J, H, K, L and M, and in polaro-imagery. Results are given.

Gallais, P.↗

Experiments to verify nonparallel stability theory at Virginia Polytechnic Institute and State University, Blacksburg, Virginia

The effects of normal mass injection and suction on boundary-layer stability and transition are studied on a flat plate. Titanium panels, in which 0.063 mm diameter holes were drilled on 0.635 mm centers, are inserted in the plate. Suction level and distribution are variable. Disturbances are introduced by means of a vibrating ribbon and measurements of both mean- and disturbance-flow velocities are made with a hot wire. Disturbance amplitudes are measured as a function of Reynolds number, frequency, and suction characteristics, and are compared with the previous results obtained over a Dynapore surface. Transition measurements under natural and forced conditions are also made. The stabilizing effects of suction are documented. It is also shown that very high local flow rates through the suction holes (which approach a hole Reynolds number of 300) do not destabilize the flow. On the other hand, weak blowing lowers the transition Reynolds number, but is found not to cause serious problems.

Saric, William S.↗

Advanced Thin Film Core Technology: CIGS Final Technical Report (FTR)

Cu(In,Ga)Se 2 (CIGS) thin-film photovoltaics are a high-efficiency and reliable technology. This project completed research in two important areas and was designed to work collaboratively with industrial partners. Task 1: Alkali Science focused on alkali post-deposition treatments (PDT). PDTs have been instrumental in the dramatic voltage improvements that have moved CIGS device efficiencies from 20% to 23.35% [1]. Based on a survey of CIGS companies at the beginning of the project, the single biggest breakthrough for the CIGS community would be a mechanistic understanding of the role of alkalis in the material system. Significant accomplishments of Task 1: Alkali Science: 1) KF post-deposition treatments were shown to improve lifetime, open-circuit voltage (VOC), and efficiency of industrial partner samples, even when done as a later step, separate from the original CIGS deposition. 2) KF boosted efficiency when incorporated at the end of the third stage of NREL CIGS growth. 3) XPS characterization of CIGS surfaces with and without PDTs led to a proposed mechanism whereby K drives structural transformation at 350 degrees C that is locked in at room temperature even after K is rinsed away. 4) Published recipes for KF and RbF PDTs. Literature to date did not provide enough detail to quickly reproduce experimental results. 5) Identified most important parameters (RbF cell temperature and lamp setpoint temperature) and set boundaries for successful RbF PDTs. The purpose of Task 2: Cell-level Reliability was to overcome the largest challenges to investor confidence and long product lifetime in CIGS-based photovoltaic products: metastability, shading-induced hot spots, and potential-induced degradation (PID). Key findings were made in each of these areas by studying CIGS reliability at the cell level: 1) Published NREL's cell-level reliability testing procedures along with challenges that were encountered while developing them. These were also distributed to the community through an MRS conference presentation. 2) Decreased metastability by adding a CdS hole-injection layer between the CIGS and Zn(O,S) in the device stack. It also improved device performance. Materials other than CdS can be used for the same purpose. 3) Reduced front-glass PID by replacing soda-lime glass with low-Na borosilicate glass. 4) Found that PID depends on leakage current and light/electrical bias. This will help labs avoid test-specific degradation. 5) Discovered that CIGS can suffer from two different types of PID with different mechanisms. Front is slower and leads to shunting ZnO. Back is faster and degrades the p-n junction. 6) Holding cells at open circuit slows PID compared to short circuit. This affects testing protocols for glass/glass modules.

14 SOLAR ENERGY↗

Low gravity quenching of hot tubes with cryogens

An experimental proceedure for examining flow boiling in low gravity environment is presented. The proceedure involves both ground based and KC-135 flight experiments. Two experimental apparati were employed, one for studying subcooled liquid boiling and another for examining saturated liquid boiling. For the saturated flow experiments, liquid nitrogen was used while freon 113 was used for the subcooled flow experiments. The boiling phenomenon was investigated in both cases using flow visualization techniques as well as tube wall temperature measurements. The flow field in both cases was established by injecting cold liquid in a heated tube whose temperature was set above the saturation values. The tubes were both vertically and horizontally supported with the liquid injected from the lower end of the tube. The results indicate substantial differences in the flow patterns established during boiling between the ground based, (1-g), experiments and the flight experiments, (low-g). These differences in the flow patterns will be discussed and some explanations will be offered.

Antar, Basil N.↗

Physical processes in photon-starved nonthermal pair plasmas

Compton spectra produced by relativistic, unmagnetized, nonthermal electron-positron pairs injected into 'photon-starved' plasmas, where the luminosity in soft photons is much less than the power in the nonthermal pair injection, are studied. The overall form of the spectra consists of a rising spectrum at low energies, a single or double peak in the 0.1-1 MeV energy range, a cutoff above the peak, and a gamma-ray tail with a varying slope depending on the plasma parameters. The low-energy power law is mostly due to the primary soft photons being repeatedly upscattered by the hot thermal electrons. Comparisons are made with observations of compact objects.

Zdziarski, Andrzej A.↗

A viscous flow study of shock-boundary layer interaction, radial transport, and wake development in a transonic compressor

A numerical study based on the 3D Reynolds-averaged Navier-Stokes equation has been conducted to investigate the detailed flow physics inside a transonic compressor. 3D shock structure, shock-boundary layer interaction, flow separation, radial mixing, and wake development are all investigated at design and off-design conditions. Experimental data based on laser anemometer measurements are used to assess the overall quality of the numerical solution. An additional experimental study to investigate end-wall flow with a hot-film was conducted, and these results are compared with the numerical results. Detailed comparison with experimental data indicates that the overall features of the 3D shock structure, the shock-boundary layer interaction, and the wake development are all calculated very well in the numerical solution. The numerical results are further analyzed to examine the radial mixing phenomena in the transonic compressor. A thin sheet of particles is injected in the numerical solution upstream of the compressor. The movement of particles is traced with a 3D plotting package. This numerical survey of tracer concentration reveals the fundamental mechanisms of radial transport in this transonic compressor.

Hah, Chunill↗

Development of a Pressure-Fed Rocket Engine Using Hydrogen Peroxide and JP-8

A pressure-fed rocket engine using hydrogen peroxide and JP-8 was designed and demonstrated for upper stage space transportation applications. The engine utilizes silver plated screen catalyst to decompose 85% hydrogen peroxide (by weight). The decomposed high-temperature gas causes the JP-8 to auto-ignite and undergo chemical reaction. An ablative chamber using silica phenolic was used as the combustion chamber. The present effort includes catalyst development, injector evaluation, and chamber char and erosion characterization. Wagonwheel-type distribution and support plates were used in the catalyst bed design to reduce pressure drop, to increase active area, and to avoid flow channeling. Various fuel injection and mixing approaches were investigated and the combustion efficiency was in the range from 89 to 98%, depending on injector design and operating conditions. Fuel film cooling, up to 40% of the total fuel flow, was found to be ineffective with the current engine configuration. A ring injector was selected because of the satisfactory performance and its low cost. The char and erosion rates were determined through hot-fire tests. The char depth was found to be a function of axial distance, which was related to the progress of chemical reaction. Correlation of the char and erosion rates was developed as a design database for future applications,

Wu, P.-K.↗

Two opposed lateral jets injected into swirling crossflow

Experiments have been conducted to obtain the time-mean and turbulent quantities of opposed lateral jets in a low speed, nonreacting flowfield. A jet-to-crossflow velocity ratio of R = 4 was used throughout the experiments, with swirl vane angles of 0 (swirler removed), 45 and 70 degrees used with the crossflow. Flow visualization techniques used were neutrally-buoyant helium-filled soap bubbles and multispark photography in order to obtain the gross flowfield characteristics. Measurements of time-mean and turbulent quantities were obtained utilizing a six-orientation single hot-wire technique. For the nonswirling case, the jets were found not to penetrate past the test-section centerline, in contrast to the single lateral jet with the same jet-to-crossflow velocity ratio. In the swirling cases, the crossflow remains in a narrow region near the wall of the test section. The opposed jets are swept from their vertical courses into spiral trajectories close to the confining walls. Extensive results are presented in r-x plane plots.

Lilley, D. G.↗

Voltage Controller Saves Energy, Prolongs Life of Motors

In 1985, Power Efficiency Corporation of Las Vegas licensed NASA voltage controller technology from Marshall Space Flight Center. In the following years, Power Efficiency made patented improvements to the technology and marketed the resulting products throughout the world as the Performance Controller and the Power Efficiency energy-saving soft start. Soft start gradually introduces power to an electric motor, thus eliminating the harsh, violent mechanical stresses of having the device go from a dormant state to one of full activity; prevents it from running too hot; and increases the motor's lifetime. The product can pay for itself through the reduction in electricity consumed (according to Power Efficiency, within 3 years), depending on the duty cycle of the motor and the prevailing power rates. In many instances, the purchaser is eligible for special utility rebates for the environmental protection it provides. Common applications of Power Efficiency's soft start include mixers, grinders, granulators, conveyors, crushers, stamping presses, injection molders, elevators with MG sets, and escalators. The device has been retrofitted onto equipment at major department store chains, hotels, airports, universities, and for various manufacturers

Source record↗

Closed Loop Geothermal Working Group: GeoCLUSTER App, Subsurface Simulation Results, and Publications

To better understand the heat production, electricity generation performance, and economic viability of closed-loop geothermal systems in hot-dry rock, the Closed-Loop Geothermal Working Group -- a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed-loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and supercritical CO2) while varying seven continuous independent parameters of interest (mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying Python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the techno-economic analysis script are provided. This data submission will contain results from the Closed Loop Geothermal Working Group study that are within the public domain, including publications, simulation results, databases, and computer codes. GeoCLUSTER is a Python-based web application created using Dash, an open-source framework built on top of Flask that streamlines the building of data dashboards. GeoCLUSTER provides users with a collection of interactive methods for streamlining the exploration and visualization of an HDF5 dataset. The GeoCluster app and database are contained in the compressed file geocluster_vx.zip, where the "x" refers to the version number. For example, geocluster_v1.zip is Version 1 of the app. This zip file also contains installation instructions. **To use the GeoCLUSTER app in the cloud, click the link to "GeoCLUSTER on AWS" in the Resources section below. To use the GeoCLUSTER app locally, download the geocluster_vx.zip to your computer and uncompress this file. When uncompressed this file comprises two directories and the geocluster_installation.pdf file. The geo-data app contains the HDF5 database in condensed format, and the GeoCLUSTER directory contains the GeoCLUSTER app in the subdirectory dash_app, as app.py. The geocluster_installation.pdf file provides instructions on installing Python, the needed Python modules, and then executing the app.

15 GEOTHERMAL ENERGY↗