Development of High-Resolution Dynamic Dust Source Function - A Case Study with a Strong Dust Storm in a Regional Model

A high-resolution dynamic dust source has been developed in the NASA Unified-Weather Research and Forecasting (NU-WRF) model to improve the existing coarse static dust source. In the new dust source map, topographic depression is in 1-km resolution and surface bareness is derived using the Normalized Difference Vegetation Index (NDVI) data from Moderate Resolution Imaging Spectroradiometer (MODIS). The new dust source better resolves the complex topographic distribution over the Western United States where its magnitude is higher than the existing, coarser resolution static source. A case study is conducted with an extreme dust storm that occurred in Phoenix, Arizona in 0203 UTC July 6, 2011. The NU-WRF model with the new high-resolution dynamic dust source is able to successfully capture the dust storm, which was not achieved with the old source identification. However the case study also reveals several challenges in reproducing the time evolution of the short-lived, extreme dust storm events.

Dynamic dust source↗

Goddard high-resolution spectrograph observations of the local interstellar medium and the deuterium/hydrogen ratio along the line of sight toward Capella

HST Goddard High-Resolution Spectrograph observations of the 1216, 2600, and 2800 A spectral regions are analyzed for the spectroscopic binary system Capella, obtained at orbital phase 0.26 with 3.27-3.57 km/s resolution and high SNR. The column densities of H I, D I, Mg II, and Fe II for the local interstellar medium along this 12.5 pc line of sight, together with estimates of the temperature and turbulent velocity are inferred. It is inferred that the atomic deuterium/hydrogen ratio by number is 1.65(+0.07, -0.18) x 10 exp -5 for this line of sight. Galactic evolution calculations indicate that the primordial D/H ratio probably lies in the range of (1.5-3) x (D/H)LISM. If H0 = 80 km/s Mpc, as recent evidence suggests, then the baryonic density in units of the Einstein-de Sitter closure density is 0.023-0.031. Thus the universe is argued to expand forever, unless nonbaryonic matter greatly exceeds the amount of baryonic matter.

Linsky, Jeffrey L.↗

High Resolution X-Ray (HRX) Detector Development

During the performance period of this grant we carried out the following activities: (1) High resolution CCD camera specification and acquisition; (2) Design of CCD camera electronics; (3) Image acquisition hardware and related software development; (4) Design and construction of vacuum-compatible high resolution camera. These activities are described in detail in the report.

Golub, Leon↗

Landslide Mapping Along the Karnali Highway, Nepal using High-Resolution Imagery

The Karnali highway (Figure 1) is the only major transportation link that connects the remote Karnali region to the provincial capital in Province 6 of Nepal. This area becomes inaccessible by roads during every rainy season due to landslides. Despite the known landslide frequency, there have been no systematic landslide inventories conducted along this highway to date. Recent advancements in remote-sensing technologies have significantly increased our ability to map landslides of various sizes rapidly with less in situ surveys or human interaction. Landslide susceptibility, hazard and risk studies require a complete landslide inventory, which might only be possible from very high-resolution (VHR) and high-resolution (HR) imagery. Recent launch of Sentinel-2 in 2015 has provided free access to HR imagery enabling landslide detection at finer scales then what was possible with previous open source satellite imagery obtained from Landsat and ASTER. Satellites providing VHR imagery are commercially owned, expensive and not freely available expect for when disasters charter is activated. NextView licensing agreement, a partnership between the US government and US commercial vendors provides access to VHR imagery to federal agencies in support of scientific research [1]. This partnership provides access to VHR imagery obtained from the DigitalGlobe (DG) constellation which enables mapping of small landslides (< 100 m2). In this study, VHR imagery from DG and HR imagery from Sentinel-2 will be used to map landslides along the Karnali highway using a semi automatic method based on object-oriented analysis (OOA) to create most recent and up-to-date landslide inventory. The effectiveness of this remote sensing based landslide inventory to produce a susceptibility map and its predictive capacity will be tested.

landslide↗

Achieving High-Resolution Hard X-ray Microscopy using Monolithic 2D Multilayer Laue Lenses

This article introduces the 2D multilayer Laue lens (MLL) nanofocusing optics recently developed for high-resolution hard X-ray microscopy. The new optics utilized a micro-electro-mechanical-system (MEMS)-based template to accommodate two linear MLL optics in a pre-aligned configuration. Angular misalignment between the two lenses was controlled in tens of millidegrees, and the lateral position error was on a micrometer scale. Using the developed 2D MLLs, an astigmatism-free point focus of approximately 14 nm by 13 nm in horizontal and vertical directions, respectively, at 13.6 keV photon energy was obtained. In conclusion, the success of 2D MLL optics with an approaching 10 nm resolution is a significant step forward for the development of high-resolution hard X-ray microscopy and applications of MLL optics in the hard X-ray community.

36 MATERIALS SCIENCE↗

Initial Fulcher band observations from high resolution spectroscopy in the MAST-U divertor

High resolution D$^*_2$ Fulcher band spectroscopy was used in the MAST-U divertors during Super-X and (shorter-legged) elongated divertor density ramps with D 2 fuelling from the mid-plane high-field side. In the Super-X case, the upper divertor showed ground state rotational temperatures of the D 2 molecules increasing from ~6000 K, starting at the detachment onset, to ~9000 K during deepening detachment. This was correlated with the movement of the Fulcher emission region towards the X-point, which is in turn correlated with the movement of the ionisation source. The increase in rotational temperature occurred throughout the divertor except near the divertor entrance, where ionisation was still the dominant process. Qualitative agreement was obtained between the lower and upper divertor. Similar rotational temperatures were obtained in the elongated divertor before the detachment onset, although the increase in rotational temperature during detachment was less clearly observed as less deep detachment was obtained. The measured vibrational distribution of the upper Fulcher state does not agree with a ground state Boltzmann distribution but shows a characteristically elevated population in the ν = 2 and ν = 3 bands in particular; which is strongly correlated to the rotational temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstrating the Power of Chandra High Resolution Spectroscopy Plasma Diagnostics

The Chandra spectrometers can resolve spectroscopic features that can be used to diagnose the state of emitting plasma. Based on high resolution Chandra High Energy Transmission Grating (HETG) calibration observations of the active RS CVn-type Binary V711 Tau (HR1099), we determine for the first time the plasma density at a range of coronal temperatures for this type of object. The results are used to constrain coronal structural models and build a picture of the change in coronal structure from stars of solar-like activity to the most active RS CVn-type binaries.

Drake, Jeremy↗

A High-Resolution Capability for Large-Eddy Simulation of Jet Flows

A large-eddy simulation (LES) code that utilizes high-resolution numerical schemes is described and applied to a compressible jet flow. The code is written in a general manner such that the accuracy/resolution of the simulation can be selected by the user. Time discretization is performed using a family of low-dispersion Runge-Kutta schemes, selectable from first- to fourth-order. Spatial discretization is performed using central differencing schemes. Both standard schemes, second- to twelfth-order (3 to 13 point stencils) and Dispersion Relation Preserving schemes from 7 to 13 point stencils are available. The code is written in Fortran 90 and uses hybrid MPI/OpenMP parallelization. The code is applied to the simulation of a Mach 0.9 jet flow. Four-stage third-order Runge-Kutta time stepping and the 13 point DRP spatial discretization scheme of Bogey and Bailly are used. The high resolution numerics used allows for the use of relatively sparse grids. Three levels of grid resolution are examined, 3.5, 6.5, and 9.2 million points. Mean flow, first-order turbulent statistics and turbulent spectra are reported. Good agreement with experimental data for mean flow and first-order turbulent statistics is shown.

DeBonis, James R.↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

High resolution absorption coefficients for Freon-12

The ultra high resolution absorption coefficients of the Q-branch of Freon-12 obtained with tunable diode laser spectroscopy are presented. Continuous spectra are presented from 1155/cm to 1163/cm, and absolute wavelength calibration was obtained using SO2 spectra as a standard and a 5 cm Ge etalon for relative calibration between SO2 lines. The Freon-12 data obtained at a pressure of 0.05 torr showed a rich and highly structured spectra, but with the exception of three isolated features, collisional broadening reduces the spectra to a structureless continuum for nitrogen pressures greater than 20 torr. The spectra at 1161/cm continue to exhibit structure at atmospheric pressure.

Hoell, J. M.↗

New spectral features of stratospheric trace gases identified from high-resolution infrared balloon-borne and laboratory spectra

A new Michelson-type interferometer system operating in the infrared at very high resolution has been used to record numerous balloon-borne solar absorption spectra of the stratosphere, ground-based solar absorption spectra, and laboratory spectra of molecules of atmospheric interest. In the present work results obtained for several important stratospheric trace gases, HNO3, CIONO2, HO2NO2, NO2, and COF2, in the 8- to 12-micron spectral region are reported. Many new features of these gases have been identified in the stratospheric spectra. Comparison of the new spectra with line-by-line simulations shows that previous spectral line parameters are often inadequate and that new analysis of high-resolution laboratory and atmospheric spectra and improved theoretical calculations will be required for many bands. Preliminary versions of several sets of improved line parameters under development are discussed.

Goldman, A.↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

A non-LTE model for the Jovian methane infrared emissions at high spectral resolution

High resolution spectra of Jupiter in the 3.3 micrometer region have so far failed to reveal either the continuum or the line emissions that can be unambiguously attributed to the nu(sub 3) band of methane (Drossart et al. 1993; Kim et al. 1991). Nu(sub 3) line intensities predicted with the help of two simple non-Local Thermodynamic Equilibrium (LTE) models -- a two-level model and a three-level model, using experimentally determined relaxation coefficients, are shown to be one to three orders of magnitude respectively below the 3-sigma noise level of these observations. Predicted nu(sub 4) emission intensities are consistent with observed values. If the methane mixing ratio below the homopause is assumed as 2 x 10(exp -3), a value of about 300 K is derived as an upper limit to the temperature of the high stratosphere at microbar levels.

Halthore, Rangasayi N.↗

Detection and Bulk Properties of the HR 8799 Planets with High-resolution Spectroscopy

Using the Keck Planet Imager and Characterizer, we obtained high-resolution (R ~ 35,000) K-band spectra of the four planets orbiting HR 8799. We clearly detected H{sub 2}O and CO in the atmospheres of HR 8799 c, d, and e, and tentatively detected a combination of CO and H{sub 2}O in b. These are the most challenging directly imaged exoplanets that have been observed at high spectral resolution to date when considering both their angular separations and flux ratios. We developed a forward-modeling framework that allows us to jointly fit the spectra of the planets and the diffracted starlight simultaneously in a likelihood-based approach and obtained posterior probabilities on their effective temperatures, surface gravities, radial velocities, and spins. We measured vsin (i) values of 10.1{sub -2.7}{sup +2.8} km s{sup -1} for HR 8799 d and 15.0{sub -2.6}{sup +2.3} km s{sup -1} for HR 8799 e, and placed an upper limit of <14 km s{sup -1} of HR 8799 c. Under two different assumptions of their obliquities, we found tentative evidence that rotation velocity is anticorrelated with companion mass, which could indicate that magnetic braking with a circumplanetary disk at early times is less efficient at spinning down lower-mass planets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Plant respirometer enables high resolution of oxygen consumption rates

Plant respirometer permits high resolution of relatively small changes in the rate of oxygen consumed by plant organisms undergoing oxidative metabolism in a nonphotosynthetic state. The two stage supply and monitoring system operates by a differential pressure transducer and provides a calibrated output by digital or analog signals.

Foster, D. L.↗