A Global View Programming Abstraction for Transitioning MPI Codes to PGAS Languages

The multicore generation of scientific high performance computing has provided a platform for the realization of Exascale computing, and has also underscored the need for new paradigms in coding parallel applications. The current standard for writing parallel applications requires programmers to use languages designed for sequential execution. These languages have abstractions that only allow programmers to operate on the process centric local view of data. To provide suitable languages for parallel execution, many research efforts have designed languages based on the Partitioned Global Address Space (PGAS) programming model. Chapel is one of the more recent languages to be developed using this model. Chapel supports multithreaded execution with high-level abstractions for parallelism. With Chapel in mind, we have developed a set of directives that serve as intermediate expressions for transitioning scientific applications from languages designed for sequential execution to PGAS languages like Chapel that are being developed with parallelism in mind.

Global Domain↗

Leaching of Degraded Preservative Matrices, Based on Sodium Aluminophosphate Glasses, for High-Level Wastes

The chemical stability of vitrified high-level nuclear industry wastes in contact with water was studied experimentally in application to underground disposal of the wastes. The experiments were performed on samples of sodium aluminophosphate glass used in industrial solidification of wastes. Stable isotopes of strontium, cesium, uranium, and rare-earth elements as geochemical analogs of actinides were introduced into the glass to simulate radionuclides. It was observed that water vapor affects the degradation of the glass when vitrified wastes are placed in temporary repositories. It is shown that as a result of the degradation the rate of leaching of the glass in water increases significantly. In addition, a substantial portion of radionuclide simulators in colloidal form goes into the water medium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multipacting optimization of a 750 MHz rf dipole

Crab crossing schemes have been proposed to re-instate luminosity degradation due to crossing angles at the interaction points in next generation colliders to avoid the use of sharp bending magnets and their resulting large synchrotron radiation generation, highly undessirable in the detector region. The rf dipole has been considered for a different set of applications in several machines, both rings and linear colliders. We present in this paper a study of the effects on the multipacting levels and location depending on geometrical variations on the design for a crabbing/deflecting application in a high current (3/0.5 A), high repetition (750 MHz) electron/proton collider, as a matter to provide a comparison point for similar applications of rf dipoles.

Delayen, Jean R.↗

A High-Density, High-Efficiency, Isolated On-Board Vehicle Battery Charger Utilizing Silicon Carbide Power Devices

This paper presents an isolated on-board vehicular battery charger that utilizes silicon carbide (SiC) power devices to achieve high density and high efficiency for application in electric vehicles (EVs) and plug-in hybrid EVs (PHEVs). The proposed level 2 charger has a two-stage architecture where the first stage is a bridgeless boost ac-dc converter and the second stage is a phase-shifted full-bridge isolated dc-dc converter. The operation of both topologies is presented and the specific advantages gained through the use of SiC power devices are discussed. The design of power stage components, the packaging of the multichip power module, and the system-level packaging is presented with a primary focus on system density and a secondary focus on system efficiency. In this work, a hardware prototype is developed and a peak system efficiency of 95% is measured while operating both power stages with a switching frequency of 200 kHz. A maximum output power of 6.1 kW results in a volumetric power density of 5.0 kW/L and a gravimetric power density of 3.8 kW/kg when considering the volume and mass of the system including a case.

Whitaker, B↗

Intravenous application of an anticalin dramatically lowers plasma digoxin levels and reduces its toxic effects in rats

Lipocalins tailored with high affinity for prescribed ligands, so-called anticalins, constitute promising candidates as antidotes. Here, we present an animal study to investigate both pharmacokinetic and clinical effects of an anticalin specific for the digitalis compound digoxin. Intravenous digoxin (2.5–50 μg/kg/min) was administered to rats until first changes in the ECG occurred (dose finding study) or a priori for 30 min (kinetic study). The anticalin DigA16(H86N), dubbed DigiCal, was administered intravenously at absolute doses of 1, 5, 10 and 20 mg, while the control group received isotonic saline. Hemodynamic changes, several ECG parameters and digoxin concentration in plasma were monitored at given time intervals. After DigiCal administration free digoxin concentration in plasma ultrafiltrate declined dramatically within 1 min to the presumably non-toxic range. There was also a significant and DigiCal dose-dependent effect on longer survival, less ECG alterations, arrhythmia, and improved hemodynamics. Infusion of a lower digoxin dose (2.5 μg/kg/min) resulted in a more sustained reduction of free digoxin in plasma after DigiCal administration compared to a higher digoxin dose (25 μg/kg/min), whereas ECG and hemodynamic parameters did not markedly differ, reflecting the known relative insensitivity of rats towards digoxin toxicity. Notably, we observed a re-increase of free digoxin in plasma some time after bolus administration of DigiCal, which was presumably due to toxin redistribution from tissue in combination with the relatively fast renal clearance of the rather small protein antidote. We conclude that anticalins with appropriately engineered drug-binding activities and, possibly, prolonged plasma half-life offer prospects for next-generation antidotal therapy. -- Highlights: ► We provide an advanced model of digoxin toxicity in rats. ► We report on binding of digoxin to a novel designed anticalin. ► We report on pharmacokinetics of digoxin after intravenous anticalin administration. ► We provide clinical data on outcome improvement after anticalin administration.

60 APPLIED LIFE SCIENCES↗

LITERATURE REVIEWS TO SUPPORT ION EXCHANGE TECHNOLOGY SELECTION FOR MODULAR SALT PROCESSING

This report summarizes the results of literature reviews conducted to support the selection of a cesium removal technology for application in a small column ion exchange (SCIX) unit supported within a high level waste tank. SCIX is being considered as a technology for the treatment of radioactive salt solutions in order to accelerate closure of waste tanks at the Savannah River Site (SRS) as part of the Modular Salt Processing (MSP) technology development program. Two ion exchange materials, spherical Resorcinol-Formaldehyde (RF) and engineered Crystalline Silicotitanate (CST), are being considered for use within the SCIX unit. Both ion exchange materials have been studied extensively and are known to have high affinities for cesium ions in caustic tank waste supernates. RF is an elutable organic resin and CST is a non-elutable inorganic material. Waste treatment processes developed for the two technologies will differ with regard to solutions processed, secondary waste streams generated, optimum column size, and waste throughput. Pertinent references, anticipated processing sequences for utilization in waste treatment, gaps in the available data, and technical comparisons will be provided for the two ion exchange materials to assist in technology selection for SCIX. The engineered, granular form of CST (UOP IE-911) was the baseline ion exchange material used for the initial development and design of the SRS SCIX process (McCabe, 2005). To date, in-tank SCIX has not been implemented for treatment of radioactive waste solutions at SRS. Since initial development and consideration of SCIX for SRS waste treatment an alternative technology has been developed as part of the River Protection Project Waste Treatment Plant (RPP-WTP) Research and Technology program (Thorson, 2006). Spherical RF resin is the baseline media for cesium removal in the RPP-WTP, which was designed for the treatment of radioactive waste supernates and is currently under construction in Hanford, WA. Application of RF for cesium removal in the Hanford WTP does not involve in-riser columns but does utilize the resin in large scale column configurations in a waste treatment facility. The basic conceptual design for SCIX involves the dissolution of saltcake in SRS Tanks 1-3 to give approximately 6 M sodium solutions and the treatment of these solutions for cesium removal using one or two columns supported within a high level waste tank. Prior to ion exchange treatment, the solutions will be filtered for removal of entrained solids. In addition to Tanks 1-3, solutions in two other tanks (37 and 41) will require treatment for cesium removal in the SCIX unit. The previous SCIX design (McCabe, 2005) utilized CST for cesium removal with downflow supernate processing and included a CST grinder following cesium loading. Grinding of CST was necessary to make the cesium-loaded material suitable for vitrification in the SRS Defense Waste Processing Facility (DWPF). Because RF resin is elutable (and reusable) and processing requires conversion between sodium and hydrogen forms using caustic and acidic solutions more liquid processing steps are involved. The WTP baseline process involves a series of caustic and acidic solutions (downflow processing) with water washes between pH transitions across neutral. In addition, due to resin swelling during conversion from hydrogen to sodium form an upflow caustic regeneration step is required. Presumably, one of these basic processes (or some variation) will be utilized for MSP for the appropriate ion exchange technology selected. CST processing involves two primary waste products: loaded CST and decontaminated salt solution (DSS). RF processing involves three primary waste products: spent RF resin, DSS, and acidic cesium eluate, although the resin is reusable and typically does not require replacement until completion of multiple treatment cycles. CST processing requires grinding of the ion exchange media, handling of solids with high cesium loading, and handling of liquid wash and conditioning solutions. RF processing requires handling and evaporation of cesium eluates, disposal of spent organic resin, and handling of the various liquid wash and regenerate solutions used. In both cases, the DSS will be immobilized in a low activity waste form. It appears that both technologies are mature, well studied, and generally suitable for this application. Technology selection will likely be based on downstream impacts or preferences between the various processing options for the two materials rather than on some unacceptable performance property identified for one material. As a result, the following detailed technical review and summary of the two technologies should be useful to assist in technology selection for SCIX.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Redundant Execution of HPC Applications with MR-MPI

This paper presents a modular-redundant Message Passing Interface (MPI) solution, MR-MPI, for transparently executing high-performance computing (HPC) applications in a redundant fashion. The presented work addresses the deficiencies of recovery-oriented HPC, i.e., checkpoint/restart to/from a parallel file system, at extreme scale by adding the redundancy approach to the HPC resilience portfolio. It utilizes the MPI performance tool interface, PMPI, to transparently intercept MPI calls from an application and to hide all redundancy-related mechanisms. A redundantly executed application runs with r*m native MPI processes, where r is the number of MPI ranks visible to the application and m is the replication degree. Messages between redundant nodes are replicated. Partial replication for tunable resilience is supported. The performance results clearly show the negative impact of the O(m^m) messages between replicas. For low-level, point-to-point benchmarks, the impact can be as high as the replication degree. For applications, performance highly depends on the actual communication types and counts. On single-core systems, the overhead can be 0% for embarrassingly parallel applications independent of the employed redundancy configuration or up to 70-90% for communication-intensive applications in a dual-redundant configuration. On multi-core systems, the overhead can be significantly higher due to the additional communication contention.

Engelmann, Christian↗

Reactive transport codes for subsurface environmental simulation

A general description of the mathematical and numerical formulations used in modern numerical reactive transport codes relevant for subsurface environmental simulations is presented. The formulations are followed by short descriptions of commonly used and available subsurface simulators that consider continuum representations of flow, transport, and reactions in porous media. These formulations are applicable to most of the subsurface environmental benchmark problems included in this special issue. The list of codes described briefly here includes PHREEQC, HPx, PHT3D, OpenGeoSys (OGS), HYTEC, ORCHESTRA, TOUGHREACT, eSTOMP, HYDROGEOCHEM, CrunchFlow, MIN3P, and PFLOTRAN. The descriptions include a high-level list of capabilities for each of the codes, along with a selective list of applications that highlight their capabilities and historical development.

54 ENVIRONMENTAL SCIENCES↗

Tuning Ligand–Coordinated Single Metal Atoms on TiO 2 and their Dynamic Response during Hydrogenation Catalysis

Ligand-coordinated supported catalysts (LCSCs) are of growing interest for heterogeneous single-atom catalysis. Here, the effect of the choice of organic ligand on the activity and stability of TiO 2 -supported single-atom Pt-ligand catalysts was investigated for ethylene hydrogenation. The activity of these catalysts showed a significant dependence on the choice of ligand and also correlated with coordination number for Pt-ligand and Pt-Cl - . Of the three ligands examined in this study, the one with the lowest Pt coordination number, 1,10-phenanthroline-5,6-dione (PDO), showed the lowest reaction temperature and highest reaction rate, likely due to those metal sites being more accessible to reactant adsorption. In-situ X-ray absorption spectroscopy (XAS) experiments showed that the activity also correlated with good heterolytic dissociation of hydrogen, which was supported by OH/OD exchange experiments and was the rate-determining step of the hydrogenation reaction. In these in-situ XAS experiments up to 190 degrees C, the supported Pt-ligand catalyst showed excellent stability against structural and chemical change. Instead of Pt, the PDO ligand could be coordinated with Ir on TiO 2 to form Ir LCSCs that showed slow activation by loss of Ir-Cl bonds, then excellent stability in the hydrogenation of ethylene. Furthermore, these results provide the chance to engineer ligand-coordinated supported catalysts at the single-atom catalyst level by the choice of ligand and enable new applications at relatively high temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rahasak—Scalable blockchain architecture for enterprise applications

Blockchain-based decentralized infrastructure has been adapted in various industries to handle the sensitive data in a privacy-preserving manner without trusting third parties. However, integrating state-of-the-art blockchain platforms with the scalable, enterprise-level applications result in several challenges. Current blockchain platforms do not support high transaction throughput, lack high scalability, and cannot provide real-time transaction processing and back-pressure operation handling in high transaction throughput applications(e.g Big data, IoT). In this paper, we propose a novel permissioned blockchain platform “Rahasak” for highly scalable, enterprise applications. Rahasak blockchain adopts the Apache Kafka-based consensus on top of a “Validate-Execute-Group” blockchain architecture to handle realtime transaction execution on the blockchain. The architecture is equipped with a functional programming and actor-based smart contract platform that enables concurrent execution of transactions in the blockchain. Rahasak supports high transaction throughput, high scalability, concurrent transaction execution, data analytics features. Finally, with Rahasak, we make blockchain more scalable, secure, structured and meaningful for further data analytics.

97 MATHEMATICS AND COMPUTING↗

Molecular photoionization cross sections by Stieltjes-Chebyshev moment theory applied to Lanczos pseudospectra

Stieltjes imaging technique is widely used for the ab initio computation of photoionization cross sections and decay widths. The main problem hampering the application of the standard Stieltjes imaging algorithms in conjunction with high-level ab initio methods to polyatomic molecules is the requirement of full diagonalization of excessively large Hamiltonian matrices. Here we show that the full diagonalization bottleneck can be overcome by applying the Stieltjes imaging procedure to Lanczos pseudospectrum of the atomic or molecular Hamiltonian. Using the helium and neon atoms as examples, we demonstrate that the Lanczos pseudospectrum obtained after only a relatively small number of iterations can be used for Stieltjes-type calculations of photoionization cross sections essentially without loss of accuracy. The new technique is applied to the calculation of the total photoionization cross section of benzene within an ab initio approach explicitly taking into account single and double electronic excitations. Good agreement with experimental results is obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

The CMS Online Cluster: IT for a Large Data Acquisition and Control Cluster

The CMS online cluster consists of more than 2000 computers running about 10000 application instances. These applications implement the control of the experiment, the event building, the high level trigger, the online database and the control of t he buffering and transferring of data to the Central Data Recording at CERN. In this paper the IT solutions employed to fulfil the requirements of such a large cluster are revised. Details are given on the chosen network structure, configuration managemen t system, monitoring infrastructure and on the implementation of the high availability for the services and infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

p4est : Scalable Algorithms for Parallel Adaptive Mesh Refinement on Forests of Octrees

We present scalable algorithms for parallel adaptive mesh refinement and coarsening (AMR), partitioning, and 2:1 balancing on computational domains composed of multiple connected two-dimensional quadtrees or three-dimensional octrees, referred to as a forest of octrees. By distributing the union of octants from all octrees in parallel, we combine the high scalability proven previously for adaptive single-octree algorithms with the geometric flexibility that can be achieved by arbitrarily connected hexahedral macromeshes, in which each macroelement is the root of an adapted octree. A key concept of our approach is an encoding scheme of the interoctree connectivity that permits arbitrary relative orientations between octrees. Based on this encoding we develop interoctree transformations of octants. These form the basis for high-level parallel octree algorithms, which are designed to interact with an application code such as a numerical solver for partial differential equations. We have implemented and tested these algorithms in the p4est software library. We demonstrate the parallel scalability of p4est on its own and in combination with two geophysics codes. Using p4est we generate and adapt multioctree meshes with up to $5.13\times10^{11}$ octants on as many as 220,320 CPU cores and execute the 2:1 balance algorithm in less than 10 seconds per million octants per process.

Mathematics↗

Situational Awareness Geospatial Application (iSAGA)

Situational Awareness Geospatial Application (iSAGA) is a geospatial situational awareness software tool that uses an algorithm to extract location data from nearly any internet-based, or custom data source and display it geospatially; allows user-friendly conduct of spatial analysis using custom-developed tools; searches complex Geographic Information System (GIS) databases and accesses high resolution imagery. iSAGA has application at the federal, state and local levels of emergency response, consequence management, law enforcement, emergency operations and other decision makers as a tool to provide complete, visual, situational awareness using data feeds and tools selected by the individual agency or organization. Feeds may be layered and custom tools developed to uniquely suit each subscribing agency or organization. iSAGA may similarly be applied to international agencies and organizations.

Sher, Benjamin↗

Experimental study on GaP surface damage threshold induced by a high repetition rate femtosecond laser

The surface damage threshold of undoped bulk <110> GaP induced by a high repetition rate femtosecond pulse at 1040 nm with a duration of 61 fs was studied. The threshold value was obtained by a linear fit of the incident single pulse fluence and was confirmed with a breakdown test around the threshold level. The result will be useful in high intensity, high repetition rate laser applications and ultrafast processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward real-time quantum imaging with a single pixel camera

In this paper, we present a workbench for the study of real-time quantum imaging by measuring the frame-by-frame quantum noise reduction of multi-spatial-mode twin beams generated by four wave mixing in Rb vapor. Exploiting the multiple spatial modes of this squeezed light source, we utilize spatial light modulators to selectively pass macropixels of quantum correlated modes from each of the twin beams to a high quantum efficiency balanced detector. Finally, in low-light-level imaging applications, the ability to measure the quantum correlations between individual spatial modes and macropixels of spatial modes with a single pixel camera will facilitate compressive quantum imaging with sensitivity below the photon shot noise limit.

47 OTHER INSTRUMENTATION↗