Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Composite Bending Box Section Modal Vibration Fault Detection

One of the primary concerns with Composite construction in critical structures such as wings and stabilizers is that hidden faults and cracks can develop operationally. In the real world, catastrophic sudden failure can result from these undetected faults in composite structures. Vibration data incorporating a broad frequency modal approach, could detect significant changes prior to failure. The purpose of this report is to investigate the usefulness of frequency mode testing before and after bending and torsion loading on a composite bending Box Test section. This test article is representative of construction techniques being developed for the recent NASA Blended Wing Body Low Speed Vehicle Project. The Box section represents the construction technique on the proposed blended wing aircraft. Modal testing using an impact hammer provides an frequency fingerprint before and after bending and torsional loading. If a significant structural discontinuity develops, the vibration response is expected to change. The limitations of the data will be evaluated for future use as a non-destructive in-situ method of assessing hidden damage in similarly constructed composite wing assemblies. Modal vibration fault detection sensitivity to band-width, location and axis will be investigated. Do the sensor accelerometers need to be near the fault and or in the same axis? The response data used in this report was recorded at 17 locations using tri-axial accelerometers. The modal tests were conducted following 5 independent loading conditions before load to failure and 2 following load to failure over a period of 6 weeks. Redundant data was used to minimize effects from uncontrolled variables which could lead to incorrect interpretations. It will be shown that vibrational modes detected failure at many locations when skin de-bonding failures occurred near the center section. Important considerations are the axis selected and frequency range.

Werlink, Rudy↗

Predisposing Factors of Liver Necrosis after Transcatheter Arterial Chemoembolization in Liver Metastases from Neuroendocrine Tumor

PurposeTo investigate predictive factors for liver necrosis after transcatheter arterial chemoembolization (TACE) of neuroendocrine liver metastases.MethodsA total of 164 patients receiving 374 TACE were reviewed retrospectively to analyze predictive factors of liver necrosis. We analyzed patient age and sex; metastasis number and location; percentage of liver involvement; baseline liver function test; and pretreatment imaging abnormalities such as bile duct dilatation (BDD), portal vein narrowing (PVN), and portal vein thrombosis (PVT). We analyzed TACE technique such as Lipiodol or drug-eluting beads (DEB) as the drug’s vector; dose of chemotherapy; diameter of DEB; and number, frequency, and selectivity of TACE.ResultsLiver necrosis developed after 23 (6.1 %) of 374 TACE. In multivariate analysis, DEB > 300 μm in size induced more liver necrosis compared to Lipiodol (odds ratio [OR] 35.20; p < 0.0001) or with DEB < 300 μm in size (OR 19.95; p < 0.010). Pretreatment BDD (OR 119.64; p < 0.0001) and PVT (OR 9.83; p = 0.030) were predictive of liver necrosis. BDD or PVT responsible for liver necrosis were present before TACE in 59 % (13 of 22) and were induced by a previous TACE in 41 % (9 of 22) of cases.ConclusionDEB > 300 μm in size, BDD, and PVT are responsible for increased rate of liver necrosis after TACE. Careful analysis of BDD or PVT on pretreatment images as well as images taken between two courses can help avoid TACE complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Control the polarization state of light with symmetry-broken metallic metastructures

Controlling the polarization state, the transmission direction, the amplitude and the phase of light in a very limited space is essential for the development of on-chip photonics. Over the past decades, numerous sub-wavelength metallic microstructures have been proposed and fabricated to fulfill these demands. In this article, we review our efforts in achieving negative refractive index, controlling the polarization state, and tuning the amplitude of light with two-dimensional (2D) and three-dimensional (3D) microstructures. We designed an assembly of stacked metallic U-shaped resonators that allow achieving negative refraction for pure magnetic and electric responses respectively at the same frequency by selecting the polarization of incident light. Based on this, we tune the permittivity and permeability of the structure, and achieve negative refractive index. Further, by control the excitation and radiation of surface electric current on a number of 2D and 3D asymmetric metallic metastructures, we are able to control the polarization state of light. It is also demonstrated that with a stereostructured metal film, the whole metal surfaces can be used to construct either polarization-sensitive or polarization-insensitive prefect absorbers, with the advantage of efficient heat dissipation and electric conductivity. Our practice shows that metamaterials, including metasurface, indeed help to master light in nanoscale, and are promising in the development of new generation of photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronic and Structural Study of Zn x S x [ x = 12, 16, 24, 28, 36, 48, 96, and 108] Cage Structures

We present a density functional study on the structural and electronic properties of ZnS bubble clusters, specifically, hollow cages whose spontaneous formation was previously observed in classical molecular dynamics simulations by Spano et al. [J. Phys. Chem. B 2003, 107, 10337]. The hollow ZnS cages in our study were modeled as ZnxSx [x = 12, 16, 24, 28, 36, 48, 108], and an onionlike structure was modeled as Zn96S96. The study of energetics and stability, performed using large polarized Gaussian basis sets, indicated all structures to be energetically stable with similar binding energy of 5.5–5.6 eV per ZnS pair. Further computation of electronic properties showed that these cages have large vertical ionization energies and relatively low electron affinities in the ranges of 6.8–8.1 and 1.7–3.0 eV, respectively. They have large highest occupied molecular orbital–lowest unoccupied molecular orbital gaps between 2.5 and 3.3 eV, and quasi-particle gaps vary from 6.2 eV for Zn12S12 to 4.19 for Zn108S108. The computed vibrational frequencies for selected cages, that is, Zn12S12, Zn16S16, Zn28S28 (O, S4, and S8 point groups), and Zn36S36 indicate that these cage structures correspond to local minima on the potential energy surface. Finally, the infrared spectra calculated using large basis sets are also reported.

Bhusal, S.↗

Complex Formation and Dissociation Dynamics on Amorphous Silica Surfaces

Benzene complex formation and dissociation dynamics with silanols on the amorphous silica surfaces of nanoporous SiO 2 , from a benzene/carbon tetrachloride solution, were measured by the growth of off-diagonal peaks in the two dimensional infrared (2D IR) chemical exchange spectrum of the isolated Si-OD stretch. The presence of two types of isolated silanols, referred to as type I and II, was revealed, with dissociation time constants of 82 ps and 4.0 ps for type I and II complexes, respectively. The type I silanols are associated with the main IR absorption feature in the Si-OD stretching region, while the type II silanols give rise to a broader shoulder to lower frequency. Polarization selective pump-probe (PSPP) measurements provided the vibrational lifetimes and orientational relaxation rates of the two silanols in the CCl 4 (free) and benzene (complex) environments. The type II silanols constitute roughly 30% of the isolated silanol population and exhibit a substantially faster rate of vibrational relaxation, making the type I dynamics the dominant contribution to the PSPP and 2D IR signals. From the measured dissociation times, the enthalpies of formation for the two surface complexes were obtained; the formation of the type I complex being significantly more exothermic. Furthermore, as the type II site is preferentially removed from the amorphous silica surface with increasing activation temperature, the results provide a reasonable explanation for the increased exothermicity of benzene adsorption on silica with increasing activation temperature in previous calorimetry experiments.

14 SOLAR ENERGY↗

Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines

Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A broadband gyrotron backward-wave oscillator with tapered interaction structure and magnetic field

The gyro-monotron and gyrotron backward-wave oscillator (gyro-BWO) are the two oscillator versions of gyrotrons. While serving different functions, they are also radically different in the RF field formation mechanisms. The gyro-monotron RF field profile is essentially fixed by the resonant interaction structure, while the gyro-BWO possesses an extra degree of freedom in that the axial RF field profile is self-determined by the beam-wave interaction in a waveguide structure. The present study examines ways to utilize the latter feature for bandwidth broadening with a tapered magnetic field, while also employing a tapered waveguide to enhance the interaction efficiency. We begin with a mode competition analysis, which suggests the theoretical feasibility of broadband frequency tuning in single-mode operation. It is then shown in theory that, by controlling the RF field profile with an up- or down-tapered magnetic field, the gyro-BWO is capable of efficient operation with a much improved tunable bandwidth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On measuring stimulated photon–photon scattering using multiple ultraintense lasers

Stimulated photon–photon scattering is a predicted consequence of quantum electrodynamics that has yet to be measured directly. Measuring the cross section for stimulated photon–photon scattering is the aim of a flagship experiment for NSF OPAL, a proposed laser user facility with two, 25-PW beamlines. We present optimized experimental designs for achieving this challenging and canonical measurement. A family of experimental geometries is identified that satisfies the momentum- and energy-matching conditions for two selected laser frequency options. Numerical models predict a maximum signal exceeding 1000 scattered photons per shot at the experimental conditions envisaged at NSF OPAL. Experimental requirements on collision geometry, polarization, cotiming and copointing, background suppression, and diagnostic technologies are investigated numerically. These results confirm that a beam cotiming shorter than the pulse duration and control of the copointing on a scale smaller than the shortest laser wavelength are needed to robustly scatter photons on a per-shot basis. Finally, we assess the bounds that a successful execution of this experiment may place on the mass scale of Born–Infeld nonlinear electrodynamics beyond the standard model of physics.

Beyond the Standard Model↗

Acousto-optic method of spatial frequency filtration based on diffraction of two eigenmodes of a crystal

A method is proposed for two-dimensional spatial frequency filtration based on acousto-optic (AO) diffraction of two eigenmodes of a crystal on a single acoustic wave. It is shown that AO filters, based on the use of such diffraction, ensure the enhancement of the two-dimensional image edge during its optical Fourier processing. The main theoretical conclusions are experimentally confirmed using an AO paratellurite filter. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics↗

Low-loss millimeter-wave resonators with an improved coupling structure

Millimeter-wave superconducting resonators are a useful tool for studying quantum device coherence in a new frequency domain. However, improving resonators is difficult without a robust and reliable method for coupling millimeter-wave signals to 2D structures. We develop and characterize a tapered transition structure coupling a rectangular waveguide to a planar slotline waveguide with better than 0.5 dB efficiency over 14 GHz, and use it to measure ground-shielded resonators in the W band (75–110 GHz). Having decoupled the resonators from radiative losses, we consistently achieve single-photon quality factors above 10 5 , with a two-level-system loss limit above 10 6 , and verify the effectiveness of oxide removal treatments to reduce loss. These values are 4–5 times higher than those previously reported in the W band, and much closer to typical planar microwave resonators. The improved losses demonstrated by these on-chip millimeter-wave devices shed new light on quantum decoherence in a different frequency regime, offer increased selectivity for high-frequency detectors, and enables new possibilities for hybrid quantum experiments integrating millimeter-wave frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin state and spectroscopic modes of multiferroic BiFeO 3

Spectroscopic modes provide the most sensitive probe of the very weak interactions responsible for the properties of the long-wavelength cycloid in the multiferroic phase of BiFeO 3 below T N ≈ 640 K. Three of the four modes measured by terahertz (THz) and Raman spectroscopies were recently identified using a simple microscopic model. While a Dzyaloshinskii-Moriya (DM) interaction D along [-1, 2, -1] induces a cycloid with wave vector (2π/α) (0.5 + δ, 0.5, 0.5 - δ) (δ ≈ 0.0045), easy-axis anisotropy K along the [1, 1, 1] direction of the electric polarization P induces higher harmonics of the cycloid, which split the ${\Psi}_{1}$ modes at 2.49 and 2.67 meV and activate the ${{\Phi}}_{2}$ mode at 3.38 meV. However, that model could not explain the observed low-frequency mode at about 2.17 meV. We now demonstrate that an additional DM interaction D' along [1, 1, 1] not only produces the observed weak ferromagnetic moment of the high-field phase above 18 T but also activates the spectroscopic matrix elements of the nearly degenerate, low-frequency ${\Psi}_{0}$ and ${\Phi}_{1}$ modes, although their scattering intensities remain extremely weak. Even in the absence of easy-axis anisotropy, D' produces cycloidal harmonics that split ${\Psi}_{1}$ and activate ${\Phi}_{2}$. However, the observed mode frequencies and selection rules require that both D' and K are nonzero. This work also resolves an earlier disagreement between spectroscopic and inelastic neutron-scattering measurements.

Fishman, Randy Scott↗

Sparsity of Radiating Characteristic Modes on Infinite Periodic Structures

Characteristic modes on infinite periodic structures are studied using spectral dyadic Green’s functions. This formulation demonstrates that, in contrast to the modal analysis of finite structures, the number of radiating characteristic modes is limited by unit cell size and incident wave vector (i.e., scan angle or phase shift per unit cell). Here, the reflection tensor is decomposed into modal contributions from radiating modes, indicating that characteristic modes are a predictably sparse basis in which to study reflection phenomena.

42 ENGINEERING↗

Evaluation and Specifications for In-Line Uranium Separations Using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) Detection for Trace Elemental Analysis

Automated introduction platforms integrated with inductively coupled plasma optical emission spectroscopy (ICP-OES) systems are continuously being improved. Expanding on the introduction systems, a newly developed automated ion chromatography system was explored for performing rapid in-line separations coupled to ICP-OES for the detection of trace elements in uranium. Trace elements are separated from a uranium material and the analytes are directed into the ICP-OES for subsequent detection. Detection parameters such as exposure time frequency, wavelength selection, and settling times were explored to gain insight on optimal detection schemes for in-line trace elemental analysis. The methodology was applied in the analysis of a uranium oxide (U3O8) certified reference material, CRM-124. It was found here that the sensitivity and uncertainty of the technique are greatly affected by how the ICP-OES is employed to collect data. Overall it was determined that faster exposure replicates can provide greater peak resolution with higher fidelity measurements but are limited with respect to the total analysis time (i.e., limited in detection timely separations). In conclusion zeta scores, which combine accuracy and uncertainty of certified values and experimental values, were used to validate the ICP-OES modes of operation.

47 OTHER INSTRUMENTATION↗

The telstar satellite system

This paper describes the Telstar system and discusses the over-all system design. System considerations, the orbit selection and frequency allocation considerations are covered. A general description of the Telstar satellite and Andover, Maine, ground station provides background for companion articles in this series. Finally, the transmission performance is given with some discussion of system parameters.

TELSTAR SATELLITE↗

Prototype ultrasonic instrument for quantitative testing

Ultrasonic instrument has been developed for use in quantitative nondestructive evaluation of material defects such as cracks, voids, inclusions, and unbonds. Instrument is provided with standard pulse source and transducer for each frequency range selected and includes integral aids that allow calibration to prescribed standards.

Lynworth, L. C.↗

A parametric investigation of ride quality rating scales

The relative merits of various category scales for the prediction of human discomfort response to vibration and the mathematical relationships that allow for transformations of subjective data from one scale to another scale were determined. A total of 16 category scales were studied and these represented various parametric combinations of polarity, scale type, and number of scalar points. Sixteen subject groups were used and each subject group evaluated its comfort/discomfort to vertical sinusoidal vibration using one of the rating scales. The passenger ride quality apparatus which can expose six subjects simultaneously to predetermined vibrations was utilized. The vibration stimuli were composed of repeats of selected sinusoidal frequencies applied at each of nine peak floor acceleration levels. A higher degree of reliability and discriminability was generally obtained from unipolar continuous type scales containing either seven or nine scalar points as opposed to the other scales investigated.

Dempsey, T. K.↗