Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Operability of a Natural Gas–Air Rotating Detonation Engine

A combustor was developed to operate with natural gas and air as the primary propellants at elevated chamber pressures and air preheat temperatures representative of land-based power generation gas turbine engines. Detonation dynamics were studied to characterize the operability of rotating detonation-based pressure gain combustion systems for this application. Measurements of chamber wave dynamics were performed using high-frequency pressure transducers and high-speed imaging of broadband combustion chemiluminescence. The rotating detonation engine was tested with two injector configurations across a broad range of mass flux (200–500 kg/m 2 /s), equivalence ratio (0.85–1.2), and oxygen mass fraction (23.2–35%) conditions to determine the effect of operating parameters on the propagation of detonation waves in the combustor. Wave propagation speeds of up to 70% of the mixture Chapman–Jouguet detonation velocity and chamber pressure fluctuations greater than 4 times the mean chamber pressure were observed. Supplementing the air with additional oxygen, varying the equivalence ratio, and enriching the fuel with hydrogen revealed that combustor operability is sensitive to the chemical kinetics of the propellant mixture. Comparing the operational trends of the two injector configurations suggests that one design mixes the incoming propellants more effectively. Although most test conditions exhibited counter-rotating detonation waves within the chamber, the injector design with superior mixing characteristics was able to support single-wave propagation.

20 FOSSIL-FUELED POWER PLANTS↗

Uncertainties in turbulent statistics and fluxes of CO2 associated with density effect corrections

Density effect corrections (DEC) are applied to adjust raw CO2 fluxes measured by eddy covariance (EC) systems with open-path gas analyzers. DEC is also required for adjusting the measured CO2 concentration fluctuations to obtain the adjusted CO2 for analyzing turbulent statistics or quantifying fluxes. However, our data show that the power spectra of the DEC-adjusted CO2 are distorted in the high frequency range, as compared with the corresponding spectra of temperature and water vapor density. This contradicts the similarity behavior of scalars, as suggested by Monin-Obukhov similarity theory. It is demonstrated that such a distortion is caused by the DEC-induced spikes in the DEC-adjusted CO2, altering turbulent statistics of CO2 and scalar similarity between CO2 and other scalars. Our results suggest that CO2 fluxes are overestimated by applying DEC especially under high Bowen ratio conditions, potentially leading to substantial uncertainties in long-term ecosystem carbon exchange in dry regions.

Gao, Zhongming↗

Integrated quantum optical phase sensor in thin film lithium niobate

Abstract The quantum noise of light, attributed to the random arrival time of photons from a coherent light source, fundamentally limits optical phase sensors. An engineered source of squeezed states suppresses this noise and allows phase detection sensitivity beyond the quantum noise limit (QNL). We need ways to use quantum light within deployable quantum sensors. Here we present a photonic integrated circuit in thin-film lithium niobate that meets these requirements. We use the second-order nonlinearity to produce a squeezed state at the same frequency as the pump light and realize circuit control and sensing with electro-optics. Using 26.2 milliwatts of optical power, we measure (2.7 ± 0.2)% squeezing and apply it to increase the signal-to-noise ratio of phase measurement. We anticipate that photonic systems like this, which operate with low power and integrate all of the needed functionality on a single die, will open new opportunities for quantum optical sensing.

47 OTHER INSTRUMENTATION↗

High-pressure high-temperature synthesis and characterization of B 10 C

The boron-rich boron carbide materials have been traditionally synthesized by adding boron powder to B 4 C material and subjecting it to hot pressing sintering for materials composition containing 8.8–20 at. % carbon in boron (composition range of B 10.4 C to B 4 C). Our study explores a synthesis route for B 10 C starting from high-purity boron and carbon and direct conversion under high pressure and high temperature (HPHT) conditions of 2000 °C and 6–8 GPa. Synthesis was verified via x-ray diffraction analysis, showing the conversion of the high-purity boron and carbon powder mixture into a hexagonal B 10 C structure (R-3m space group) with lattice parameters of a = b = 5.6115 Å and c = 12.197 Å. The concentration of boron was measured through x-ray photoelectron spectroscopy, confirming the B 10 C ratio. The measured nanoindentation mean hardness of B 10 C was 40 GPa. Raman spectroscopy of the HPHT synthesized sample shows characteristic vibrational breathing modes of boron icosahedron and an additional intense band at a vibrational frequency of 380 cm –1 . This Raman band, which appears notably weaker in earlier studies and B 4 C samples, is assigned to the linear chain of B–B–B and attributed to the maximal incorporation of boron within the hexagonal structure.

36 MATERIALS SCIENCE↗

Ferroelectricity in boron-substituted aluminum nitride thin films

This manuscript demonstrates ferroelectricity in B-substituted AlN thin films and a complementary set of first-principles calculations to understand their structure-property relationships. Al 1–x B x N films are grown by dual-cathode reactive magnetron sputtering on (110)W/(001)Al 2 O 3 substrates at 300°C at compositions spanning x = 0 to x = 0.20. X-ray diffraction studies indicate a decrease in both the c and a lattice parameters with increasing B concentration, resulting in a decrease in unit cell volume and a constant c/a axial ratio of 1.60 over this composition range. Films with 0.02 ≤ x ≤ 0.15 display ferroelectric switching with remanent polarizations exceeding 125 μCcm –2 while maintaining band gap energies of > 5.2eV. The large band gap allows low frequency hysteresis measurement (200 Hz) with modest leakage contributions. At B concentrations of x > 0.15, c-axis orientation deteriorates and ferroelectric behavior is degraded. Furthermore, density-functional theory calculations corroborate the structural observations and provide predictions for the wurtzite u parameter, polarization reversal magnitudes, and composition-dependent coercive fields.

36 MATERIALS SCIENCE↗

CP-DSSS: A Novel Waveform for Multiple Access in IoT

Cyclic prefix direct sequence spread spectrum (CPDSSS) is a novel waveform with versatile characteristics that positions itself well as a secondary network to relieve the congested wireless spectrum. The underlying structure of CPDSSS allows for efficient and effective multi-access capabilites through frequency and time division schemes in a given system. The sum-rate capacity of the system is maximized when the spectrum is divided and allocated to users with the best signal-to-noise (SNR) ratio for the given channel slice. We propose an algorithm for dividing and allocating portions of the spectrum to multiple users with the final goal of maximizing the sumrate capacity of the network. We also propose and develop a precoding/equalization technique that reduces the length of the channel impulse response. This, when used along with a matched filter detector, leads to some improvement in the sum-rate capacity of the network

5G and Beyond Communications↗

Electromagnetic and Engineering Design of a High-Current 15-MeV/u Cyclotron

The capability to produce high current, low loss, and extracted external ion beams presents an enabling technology for nuclear security, isotope production, and medical applications. We report on a novel, continuous-wave cyclotron for accelerating light ions with a charge-to-mass ratio of 1/2, which is designed for 1 mA maximum and 15 MeV/u energy. This article details the conceptual electromagnetic (EM) and engineering design including the 1.1 T sector magnets and 45 MHz, 200 kV radio frequency (RF) cavities. We discuss the cyclotron beam parameters with respect to potential commercial and industrial applications. The general concept and the accelerator’s layout are followed by a detailed EM design of magnets and RF cavities. Finally, practical engineering design considerations will be provided.

07 ISOTOPE AND RADIATION SOURCES↗

Daily evapotranspiration changes during heatwaves at 32 NEON sites, 2019-2021

This dataset provides partitioned evapotranspiration (ET, the combined loss of water from soil and plant surfaces) anomalies during heatwave events—soil evaporation (E) and transpiration (T)—for 268 heatwave events across 32 National Ecological Observatory Network (NEON) flux sites in the contiguous United States from 2019–2021. Using an ensemble of four high-frequency turbulence methods (Flux-variance Similarity, Conditional Eddy Covariance [CEC], CEC with Water-Use Efficiency, and Conditional Eddy Accumulation; see Zahn and Bou-Zeid 2024), half-hourly transpiration-to-evapotranspiration (T/ET) ratios were derived from 20 hertz (Hz, cycles per second) eddy covariance measurements of carbon dioxide (CO₂) and water vapor (H₂O) concentrations. The dataset spans six vegetation types including evergreen and deciduous forests, grasslands, cultivated crops, shrublands, and emergent herbaceous wetlands. Data Package Contents: The dataset includes a single CSV (comma-separated values) file containing daily anomalies (deviations from baseline conditions) for transpiration (Delta_T), evaporation (Delta_E), total evapotranspiration (Delta_ET), and T/ET ratio (Delta_T_ET) during each day of identified heatwave events. The file also includes site codes, dates, heatwave event identifiers, and day-of-heatwave indicators. The CSV file can be opened with spreadsheet software (Microsoft Excel, Google Sheets) or programming environments (Python, R, MATLAB). This resource enables researchers to investigate ecosystem-specific responses to thermal extremes, validate land surface model partitioning of ET fluxes, and examine feedbacks between water cycling and surface energy balance during heatwaves. The dataset is particularly valuable for studies linking vegetation hydraulic strategies to climate resilience, as it captures the divergent responses of shallow-rooted versus deep-rooted ecosystems. Potential applications include improving drought early warning systems, informing irrigation management strategies, and advancing our mechanistic understanding of land-atmosphere interactions under extreme heat conditions.

Day of Heatwave↗

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

Bottom-up synthesis of mesoscale nanomeshes of graphene nanoribbons on germanium

The synthesis of functional graphene nanostructures on Ge(001) provides an attractive route toward integrating graphene-based electronic devices onto complementary metal oxide semiconductor-compatible platforms. In this study, we leverage the phenomenon of the anisotropic growth of graphene nanoribbons from rationally placed graphene nanoseeds and their rotational self-alignment during chemical vapor deposition to synthesize mesoscale graphene nanomeshes over areas spanning several hundred square micrometers. Lithographically patterned nanoseeds are defined on a Ge(001) surface at pitches ranging from 50 to 100 nm, which serve as starting sites for subsequent nanoribbon growth. Rotational self-alignment of the nanoseeds followed by anisotropic growth kinetics causes the resulting nanoribbons to be oriented along each of the equivalent, orthogonal Ge < 110 > directions with equal probability. As the nanoribbons grow, they fuse, creating a continuous nanomesh. In contrast to nanomesh synthesis via top-down approaches, this technique yields nanomeshes with atomically faceted edges and covalently bonded junctions, which are important for maximizing charge transport properties. Additionally, we simulate the electrical characteristics of nanomeshes synthesized from different initial nanoseed-sizes, size-polydispersities, pitches, and device channel lengths to identify a parameter-space for acceptable on/off ratios and on-conductance in semiconductor electronics. The simulations show that decreasing seed diameter and pitch are critical to increasing nanomesh on/off ratio and on-conductance, respectively. With further refinements in lithography, nanomeshes obtained via seeded synthesis and anisotropic growth are likely to have superior electronic properties with tremendous potential in a multitude of applications, such as radio frequency communications, sensing, thin-film electronics, and plasmonics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Optical Trapping of High-Aspect-Ratio NaYF Hexagonal Prisms for kHz-MHz Gravitational Wave Detectors

Here, we present experimental results on optical trapping of Yb-doped β-NaYF subwavelength-thickness high-aspect-ratio hexagonal prisms with a micron-scale radius. The prisms are trapped in vacuum using an optical standing wave, with the normal vector to their face oriented along the beam propagation direction, yielding much higher trapping frequencies than those typically achieved with microspheres of similar mass. This platelike geometry simultaneously enables trapping with low photon-recoil-heating, high mass, and high trap frequency, potentially leading to advances in high frequency gravitational wave searches in the Levitated Sensor Detector, currently under construction. The material used here has previously been shown to exhibit internal cooling via laser refrigeration when optically trapped and illuminated with light of suitable wavelength. Employing such laser refrigeration methods in the context of our work may enable higher trapping intensity and thus higher trap frequencies for gravitational wave searches approaching the several hundred kilohertz range.

47 OTHER INSTRUMENTATION↗

The influence of dietary intake of omega-3 polyunsaturated fatty acids on the association between short-term exposure to ambient nitrogen dioxide and respiratory and cardiovascular outcomes among healthy adults

Background: Short-term exposure to ambient nitrogen dioxide (NO 2 ) is associated with adverse respiratory and cardiovascular outcomes. Supplementation of omega-3 polyunsaturated fatty acids (PUFA) has shown protection against exposure to fine particulate matter. This study aims to investigate whether habitual omega-3 PUFA intake differentially modify the associations between respiratory and cardiovascular responses and short-term exposure to ambient NO 2 . Methods: Sixty-two healthy participants were enrolled into low or high omega-3 groups based on their habitual omega-3 PUFA intake. Each participant was repeatedly assessed for lung function, blood lipids, markers of coagulation and fibrinolysis, vascular function, and heart rate variability (HRV) in up to five sessions, each separated by at least 7 days. This study was carried out in the Research Triangle area of North Carolina, USA between October 2016 and September 2019. Daily ambient NO 2 concentrations were obtained from an area air quality monitoring station on the day of outcome assessment (Lag0), 4 days prior (Lag1-4), as well as 5-day moving average (5dMA). The associations between short-term exposure to NO 2 and the measured indices were evaluated using linear mixed-effects models stratified by omega-3 levels and adjusted by covariates including relative humidity and temperature. Results: The average concentration of ambient NO 2 during the study periods was 5.3±3.8 ppb which was below the National Ambient Air Quality Standards (NAAQS). In the high omega-3 group, an interquartile range (IQR) increase in short-term NO 2 concentrations was significantly associated with increased lung function [e.g. 1.2% (95%CI: 0.2%, 2.2%) in FVC at lag1, 2.6% (95%CI: 0.4%, 4.8%) in FEV1 at 5dMA], decreased blood lipids [e.g. -2.6% (95%CI: -4.4%, -0.9%) in total cholesterol at lag2, -3.1% (95%CI: -6.1%, 0.0%) in HDL at 5dMA, and -3.1% (95%CI: -5.5%, -0.7%) in LDL at lag2], improved vascular function [e.g. 8.9% (95%CI: 0.6%, 17.2%) increase in FMD and 43.1% (95%CI: -79.8%, -6.3%) decrease in endothelin-1 at 5dMA], and changed HRV parameters [e.g. -7.2% (95%CI: -13.6%, -0.8%) in HFn and 13.4% (95%CI: 0.2%, 28.3%) in LF/HF ratio at lag3]. In the low omega-3 group, an IQR increase in ambient NO 2 was associated with elevations in coagulation markers (von Willebrand Factor, D-dimer) and a decrease in HRV (very-low frequency); however, null associations were observed between short-term NO 2 exposure and changes in lung function, blood lipids, and vascular function. Conclusions: The results in this study imply that dietary omega-3 PUFA consumption may offer respiratory and vascular benefits in response to short-term exposure of healthy adults to NO 2 levels below the NAAQS.

54 ENVIRONMENTAL SCIENCES↗

Microscopic understanding of the effects of impurities in low RRR SRF cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

43 PARTICLE ACCELERATORS↗

Microscopic Understanding of the Effects of Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Understanding of the Effects of Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

Microscopic understanding of the effects of impurities in low RRR SRF cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗