Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Monte Carlo turbulence simulation using rational approximations to von Karman spectra

Turbulence simulation is computationally much simpler using rational spectra, but turbulence falls off as f exp -5/3 in frequency ranges of interest to aircraft response and as predicted by von Karman's model. Rational approximations to von Karman spectra should satisfy three requirements: (1) the rational spectra should provide a good approximation to the von Karman spectra in the frequency range of interest; (2) for stability, the resulting rational transfer function should have all its poles in the left half-plane; and (3) at high frequencies, the rational spectra must fall off as an integer power of frequency, and since the -2 power is closest to the -5/3 power, the rational approximation should roll off as the -2 power at high frequencies. Rational approximations to von Karman spectra that satisfy these three criteria are presented, along with spectra from simulated turbulence. Agreement between the spectra of the simulated turbulence and von Karman spectra is excellent.

Campbell, C. W.↗

Tag that enhances vehicle radar visibility of objects

A tag enhances vehicle radar visibility of objects by increasing the effective radar cross-section of the object, allowing detection at longer ranges and providing the vehicle/driver with more time to avoid a collision. The tag may include a receive antenna and a bandpass filter configured to receive a signal from the receive antenna and to allow a portion of the frequency range of the signal from the receive antenna through. The tag may also include an amplifier configured to receive and amplify the signal with the portion of the frequency range from the bandpass filter. The tag may further include a transmit antenna configured to transmit the amplified signal. The receive antenna, the transmit antenna, and the amplifier may be configured such that antenna-to-antenna isolation between the receive antenna and the transmit antenna is greater than a gain of the amplifier.

42 ENGINEERING↗

Morphological Degradation of Oxygen Evolution Reaction-Electrocatalyzing Nickel Selenides at Industrially Relevant Current Densities

We investigated electrodeposited nanoparticulate nickel selenide (pre)catalysts that transform into nickel oxides/ oxyhydroxides under oxygen evolution reaction conditions in alkaline solutions. Previous studies of this transformation were conducted at lower current densities than those of industrial relevance (≥1 A cm −2 ). We used ultramicroelectrodes (UMEs) to achieve such current densities, benefiting from their small size, ensuring low absolute currents and low ohmic drop but high current densities. Morphological degradation of the catalyst material was only observed at current densities exceeding 1 A cm −2 but not for smaller ones. Using X-ray absorption, Xray photoemission spectroscopy, and X-ray diffraction, we confirmed that the degradation was accompanied by the literature-known transformation of nanoparticulate Ni 3 Se 2 (bulk)/NiSe (surface) into nickel oxyhydroxide. The transformation of the precatalyst goes along with a significant improvement in the charge transfer kinetics observed by decreasing Tafel slopes with ongoing experimental time extracted from cyclic voltammetry (CV) experiments and electrochemical impedance spectroscopy (EIS) in the high-frequency range. However, these kinetic improvements are accompanied by limitations in mass transport concluded from decreasing current responses at high overpotentials in CVs and increasing impedance in the low-frequency range of the EIS spectra after extended CV cycling. These mass transport limitations originated from morphological degradations at the UME exceeding 1 A cm −2 which we proved by applying identical location scanning electron microscopy. This has not been reported in studies that have been limited to lower current densities before. Our findings showcase how UMEs can be used to study (pre)catalysts (herein nickel selenides) under current densities of industrial relevance in the absence of ohmic drop-related ambiguities, combined with in-depth materials characterization studies, e.g., identical location microscopy and advanced spectroscopic methods. This approach enables direct evaluation and comparison of catalyst materials and thus demonstrates how to overcome long-standing limitations of electrocatalyst design and testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid Alfven resonant mode generation in the magnetosphere-ionosphere coupling system

Feedback unstable Alfven waves involving global field-line oscillations and the ionospheric Alfven resonator (IAR) were comprehensively studied to clarify their properties of frequency dispersion, growth rate, and eigenfunctions. It is discovered that a new mode called here the hybrid Alfven resonant (HAR) mode can be destabilized in the magnetosphere-ionosphere coupling system with a realistic Alfven velocity profile. The HAR mode found in a high frequency range over 0.3 Hz is caused by coupling of IAR modes with strong dispersion and magnetospheric cavity resonances. The harmonic relation of HAR eigenfrequencies is characterized by a constant frequency shift from those of IAR modes. The three modes are robustly found even if effects of two-fluid process and ionospheric collision are taken into account and thus are anticipated to be detected by magnetic field observations in a frequency range of 0.3-1 Hz in auroral and polar-cap regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SETI prototype system for NASA's Sky Survey microwave observing project - A progress report

Two complementary search strategies, a Targeted Search and a Sky Survey, are part of NASA's SETI microwave observing project scheduled to begin in October of 1992. The current progress in the development of hardware and software elements of the JPL Sky Survey data processing system are presented. While the Targeted Search stresses sensitivity allowing the detection of either continuous or pulsed signals over the 1-3 GHz frequency range, the Sky Survey gives up sensitivity to survey the 99 percent of the sky that is not covered by the Targeted Search. The Sky Survey spans a larger frequency range from 1-10 GHz. The two searches will deploy special-purpose digital signal processing equipment designed and built to automate the observing and data processing activities. A two-million channel digital wideband spectrum analyzer and a signal processor system will serve as a prototype for the SETI Sky Survey processor. The design will permit future expansion to meet the SETI requirement that the processor concurrently search for left and right circularly polarized signals.

Klein, M. J.↗

Comparisons of Long-Term Schumann Resonance Records in Europe and North America

Two stations at a distance comparable with the wavelength in the Schumann resonance (SR) frequency range, one in Europe (Nagycenk, Hungary) and one in North America (West Greenwich, Rhode Island) have simultaneously monitored the natural vertical electric and horizontal magnetic field components in the frequency range of 3-25 Hz. This is a unique opportunity, as Schumann resonance stations are scarce and even fewer station have records with 5-6 year durations. The main purpose of this paper is to make comparisons in the SR time series measured simultaneously at the two field site, thereby providing access to global behavior on the seasonal and interannual time scales. The comparative measurements described here point out distinct differences in the nature of convection in South America and in Africa and reveal new aspects about the behavior of tropical continental convection on the ENSO time scale.

Satori, G.↗

Near-source and Remote Observations of Kilometric Continuum Radiation from Multispacecraft Observations

[I] Kilometric continuum (KC) radiation was first identified from Geotail plasma wave observations. Past authors have shown that this emission has a frequency range that overlaps that of the auroral kilometric radiation (AKR) but is characterized by a fine structure of narrow-bandwidth, linear features that have nearly constant or drifting frequency. This fine structure is distinct from that of AKR. KC also apparently has a distinct source region probably associated with the low-latitude inner magnetosphere, consistent with direction-finding and ray-tracing results. We present new high-resolution electric and magnetic field observations of KC obtained by the Polar plasma wave instrument in the near-source region. These observations show intense electrostatic and less intense electromagnetic emissions near the magnetic equator at the plasmapause. Simultaneously, Geotail, located at 20 to 30 RE in radial distance, observes KC in the same frequency range. These data support a possible mode-conversion source mechanism near a region of high-density gradient. High-resolution data obtained from wideband receivers on board both Polar and Cluster show closely spaced bands of emission near the magnetic equator that may be due to many nearby independent sources of EM emission perhaps associated with density fluctuations or cavities in the plasmasphere.

Menietti, J. D.↗

PARTICLE ACCELERATION IN PLASMOID EJECTIONS DERIVED FROM RADIO DRIFTING PULSATING STRUCTURES

We report observations of slowly drifting pulsating structures (DPSs) in the 0.8-4.5 GHz frequency range of the RT4 and RT5 radio spectrographs at Ondřejov Observatory, between 2002 and 2012. We found 106 events of DPSs, which we classified into four cases: (I) single events with a constant frequency drift (12 events), (II) multiple events occurring in the same flare with constant frequency drifts (11 events), (III) single or multiple events with increasing or decreasing frequency drift rates (52 events), and (IV) complex events containing multiple events occurring at the same time in a different frequency range (31 events). Many DPSs are associated with hard X-ray (HXR) bursts (15-25 keV) and soft X-ray (SXR) gradient peaks, as they typically occurred at the beginning of HXR peaks. This indicates that DPS events are related to the processes of fast energy release and particle acceleration. Furthermore, interpreting DPSs as signatures of plasmoids, we measured their ejection velocity, their width, and their height from the DPS spectra, from which we also estimated the reconnection rate and the plasma beta. In this interpretation, constant frequency drift indicates a constant velocity of a plasmoid, and an increasing/decreasing frequency drift indicates a deceleration/acceleration of a plasmoid ejection. The reconnection rate shows a good positive correlation with the plasmoid velocity. Finally we confirmed that some DPS events show plasmoid counterparts in Solar Dynamics Observatory/Atmospheric Imaging Assembly images.

79 ASTRONOMY AND ASTROPHYSICS↗

Multicolored microwave absorbers with dynamic frequency modulation

Microwave-absorbing materials are extensively used in intelligent electronic devices and stealth technologies where the ability to dynamically adjust microwave-absorbing capacity in response to specific requirements is vitally important. Herein, we report a new approach for constructing dynamically tunable microwave absorbers with ultrawide tunable frequency ranges that are simultaneously endowed with vibrant structural colors. Here, the methodology produces structural colors and adjusts absorption properties by constructing ZnO coatings with precisely adjustable thicknesses on a polypyrrole/melamine foam (PPy/MF) surface by atomic layer deposition (ALD) in conjunction with a pressure-driven strategy that regulates the compression ratio. The electrical conductivity, electromagnetic parameters, thickness, and pore size of the ZnO-coated PPy/MF (ZnO/PPy/MF) are effectively adjusted, and simply applying external pressure widens the tunable frequency range and the effective absorption bandwidth. As a result, the effective absorption frequency of ZnO/PPy/MF is dynamically adjustable from the S band to the Ku band, thereby covering 94.3% of the entire microwave spectrum. Moreover, the brilliant and uniform structural colors of ZnO/PPy/MF, which span various color categories, are precisely regulated by tuning the thickness of the ZnO coating by adjusting the number of ALD cycles. ZnO/PPy/MF is strongly hydrophobic, which endows it with remarkable self-cleaning properties. Therefore, ZnO/PPy/MF provides a conceptually novel platform for the development of next-generation smart microwave-absorbing materials due to its integrated dynamic frequency-regulating ability, brilliant structural coloration, and self-cleaning features.

36 MATERIALS SCIENCE↗

Dark Photon Dark Matter and Low-frequency Gravitational-wave Detection with Gaia-like Astrometry

Astrometric surveys offer us a method for searching for elusive cosmic signatures, such as ultralight dark photon dark matter and gravitational waves (GWs), by observing the temporal change of stars’ apparent locations. The detection capabilities of such surveys rapidly decrease at low frequencies, because the signals become hardly distinguishable from the background motion of stars. In this work, we find that the background motion can be well described by a linear model over time, based on which we propose a linear background subtraction scheme. Compared to the conventional quadratic subtraction, the advantage of linear subtraction emerges within the frequency range below 6 × 10 −9 Hz. Taking dark photons with purely gravitational interactions, dark photons with additional U(1) B or U(1) B−L gauge interactions, and low-frequency GWs as examples, we illustrate that the linear subtraction scheme can result in an enhancement of more than 1 order of magnitude in the exclusion limits of Gaia-like experiments in the low-frequency range.

Astrometry↗

Octave-spanning terahertz quarter-wave plates based on over-coupled Fabry–Pérot resonances in reflective metal–dielectric–metal metasurfaces

Compact devices for broadband polarization control in the terahertz (THz) regime remain challenging to realize due to the intrinsic phase dispersion associated with birefringent materials and resonant structures. Here, we demonstrate achromatic THz quarter-wave plates with near-unity efficiency and operating under a wide range of incidence angles, based on over-coupled metal–dielectric–metal reflective metasurfaces. The devices operate as single-port anisotropic Fabry–Pérot cavities, in which the phase dispersion of the over-coupled resonances is engineered to maintain an approximately constant relative phase delay between orthogonal field components over a broad frequency range. Four complementary metasurface designs operating at an incidence angle of 45° collectively cover the 0.25–3 THz frequency range accessible to a typical THz time-domain spectroscopy system. Each device exhibits an approximately octave-wide operational bandwidth, with axial ratios below 3 dB and polarization-conversion efficiencies exceeding 80% across most of the operating band. Systematic structural optimization suppresses coupling to diffraction and guided-wave modes, thereby further extending the usable bandwidth while preserving the required phase relationship between orthogonal polarizations. The demonstrated metasurfaces are compatible with wafer-scale fabrication processes, and experimental results show excellent agreement with simulations. These findings establish over-coupled reflective metasurfaces as a robust, scalable, and versatile platform for broadband THz polarization control.

36 MATERIALS SCIENCE↗

Use of a Microphone Phased Array to Determine Noise Sources in a Rocket Plume

A 70-element microphone phased array was used to identify noise sources in the plume of a solid rocket motor. An environment chamber was built and other precautions were taken to protect the sensitive condenser microphones from rain, thunderstorms and other environmental elements during prolonged stay in the outdoor test stand. A camera mounted at the center of the array was used to photograph the plume. In the first phase of the study the array was placed in an anechoic chamber for calibration, and validation of the indigenous Matlab(R) based beamform software. It was found that the "advanced" beamform methods, such as CLEAN-SC was partially successful in identifying speaker sources placed closer than the Rayleigh criteria. To participate in the field test all equipments were shipped to NASA Marshal Space Flight Center, where the elements of the array hardware were rebuilt around the test stand. The sensitive amplifiers and the data acquisition hardware were placed in a safe basement, and 100m long cables were used to connect the microphones, Kulites and the camera. The array chamber and the microphones were found to withstand the environmental elements as well as the shaking from the rocket plume generated noise. The beamform map was superimposed on a photo of the rocket plume to readily identify the source distribution. It was found that the plume made an exceptionally long, >30 diameter, noise source over a large frequency range. The shock pattern created spatial modulation of the noise source. Interestingly, the concrete pad of the horizontal test stand was found to be a good acoustic reflector: the beamform map showed two distinct source distributions- the plume and its reflection on the pad. The array was found to be most effective in the frequency range of 2kHz to 10kHz. As expected, the classical beamform method excessively smeared the noise sources at lower frequencies and produced excessive side-lobes at higher frequencies. The "advanced" beamform routine CLEAN-SC created a series of lumped sources which may be unphysical. We believe that the present effort is the first-ever attempt to directly measure noise source distribution in a rocket plume.

Panda, J.↗

An investigation of hydraulic-line resonance and its attenuation

An investigation of fluid resonance in high-pressure hydraulic lines has been made with two types of fluid dampers (or filters) installed in the line. One type involved the use of one or more closed-end tubes branching at right angles from a main line, and the other type was a fluid muffler installed in-line. These devices were evaluated in forced vibration tests with oscillatory disturbances over a 1000-Hz range applied to one end of the line and with oscillatory pressures measured at various stations along the main pipe. Limited applications of acoustic-wave theory to the branched systems are also included. Results show varying attenuations of pressure perturbations, depending on the number and location of branches and the type of muffler. Up to three branches were used in the branch-resonator study, and the largest frequency range with maximum attenuation was obtained for a three-branch configuration. The widest frequency ranges with significant attenuations were obtained with two types of fluid mufflers.

Sewall, J. L.↗

TRW plasma wave experiment for the IMP-H mission

The IMP-H plasma wave experiment is designed to extend knowledge of wave-particle interactions in the disturbed cislunar region, the distant geomagnetic tail, the upstream solar wind, and the flanks of the magnetosheath-shock interface. It is expected to identify plasma instabilities, study particle acceleration and heating at collisionless shocks and other discontinuities, analyze turbulent conductivity and field line merging, and provide new information on dissipation processes for suprathermal particles. Instrumentation for the plasma wave experiment is designed to measure local electric and magnetic field oscillations over the frequency range 10 Hz to 100 kHz. A 24 inch electric dipole, a 7 inch diameter air core search coil, and the associated preamplifiers are mounted on a spacecraft counterweight boom. The frequency range of 10 Hz to 100 kHz for both E and B is processed using an eight-channel spectrum analyzer located in the instrument main-body package (a standard IMP trapezoidal module, 3 inches high). Electric fields as small as 10-100 microvolts/meter and magnetic signals as small as 1-3 milligamma will be detected.

Virobik, P. F.↗

Analysis of proposed criteria for human response to vibration

The development of criteria for human vibration response is reviewed, including the evolution of the ISO standard 2631. The document is analyzed to show why its application to vehicle ride evaluation is strongly opposed. Alternative vertical horizontal limits for comfort are recommended in the ground vehicle ride frequency range above 1 Hz. These values are derived by correlating the absorbed power findings of Pradko and Lee with other established criteria. Special emphasis is placed on working limits in the frequency range of 1 to 10 Hz since this is the most significant area in ground vehicle ride evaluation.

Janeway, R. N.↗

Dual nature of the orientational effect of ultrasound on liquid crystals

The new model of thresholdless distortion of the orientational structure in a homeotropic layer of nematic liquid crystal with free ends in ultrasonic field has been experimentally substantiated for the first time. The model is constructed within the concepts of nonequilibrium thermodynamics and statistical hydrodynamics of liquid crystals for the frequency range in which the elastic and viscous wavelengths are, respectively, longer and shorter than the layer thickness. The main regularities of the phenomenon, which relate the conditional effect threshold to the ultrasonic frequency and layer thickness, have been established based on the experimental data for (20–150)-μm-thick layers in the frequency range of 0.1–9 MHz. These data are compared with the results of numerical calculations, performed taking into account two mechanisms of liquid crystal structure distortion (convective and nonlinear relaxation ones).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Experimental study of noise transmission into a general aviation aircraft

The effect of add-on treatments on noise transmission into a cabin of a light aircraft was studied under laboratory conditions for diffuse and localized noise inputs. Results indicate that stiffening skin panels with honeycomb would provide on the average 3dB to 7 dB insertion loss over the most of selected frequency range H1 to 1000 Hz. Addition of damping tape on top of the honeycomb treatment increases insertion loss by 2dB to 3dB. Porous acoustic blankets show no attenuation of transmitted noise for frequencies below 300 Hz. Insertion of impervious vinyl septa between the layers of porous acoustic blankets do not provide additional noise reduction for frequencies up to about 500 Hz. Similar behavior was observed for noise barriers composed of urethane elastomer, decoupler foam and acoustic foam. A treatment composed from several layers of acoustic foams does not increase noise attenuation for the entire frequency range studied. An acoustic treatment composed of honeycomb panels, constrained layer damping tape, 2 to 3 inches of porous acoustic blankets, and limptrim which is isolated from the vibrations of the main fuselage structure seems to provide the best option for noise control.

Vaicaitis, R.↗