Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fixed source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Measuring the speed of light with ultra-compact radio quasars

In this paper, based on a 2.29 GHz VLBI all-sky survey of 613 milliarcsecond ultra-compact radio sources with 0.0035< z <3.787, we describe a method of identifying the sub-sample which can serve as individual standard rulers in cosmology. If the linear size of the compact structure is assumed to depend on source luminosity and redshift as l {sub m} = l L {sup β} (1+ z ) {sup n} , only intermediate-luminosity quasars (10{sup 27} W/Hz< L < 10{sup 28} W/Hz) show negligible dependence (| n |≅ 10{sup −3}, |β|≅ 10{sup −4}), and thus represent a population of such rulers with fixed characteristic length l =11.42 pc. With a sample of 120 such sources covering the redshift range 00.46< z <2.8, we confirm the existence of dark energy in the Universe with high significance under the assumption of a flat universe, and obtain stringent constraints on both the matter density Ω {sub m} =0.323{sup +0.245}{sub −0.145} and the Hubble constant H {sub 0}=66.30{sup +7.00}{sub −8.50} km sec{sup −1} Mpc{sup −1}. Finally, with the angular diameter distances D {sub A} measured for quasars extending to high redshifts (0 z ∼ 3.), we reconstruct the D {sub A} ( z ) function using the technique of Gaussian processes. This allows us to identify the redshift corresponding to the maximum of the D {sub A} ( z ) function: 0 z {sub m} =1.7 and the corresponding angular diameter distance D {sub A} ( z {sub m} )=1719.01±43.46 Mpc. Similar reconstruction of the expansion rate function H ( z ) based on the data from cosmic chronometers and BAO gives us H ( z {sub m} )=176.77±6.11 km sec{sup −1} Mpc{sup −1}. These measurements are used to estimate the speed of light: c =3.039(±0.180)× 10{sup 5} km/s. This is the first measurement of the speed of light in a cosmological setting referring to the distant past.

79 ASTRONOMY AND ASTROPHYSICS↗

The gallium anomaly

In order to test the end-to-end operations of gallium solar neutrino experiments, intense electron-capture sources were fabricated to measure the responses of the radiochemical SAGE and GALLEX/GNO detectors to known fluxes of low-energy neutrinos. Such tests were viewed at the time as a cross-check, given the many tests of 71 Ge recovery and counting that had been routinely performed, with excellent results. However, the four 51 Cr and 37 Ar source experiments yielded rates below expectations, a result commonly known as the Ga anomaly. As the intensity of the electron-capture sources can be measured to high precision, the neutrino lines they produce are fixed by known atomic and nuclear rates, and the neutrino absorption cross section on 71 Ga is tightly constrained by the lifetime of 71 Ge, no simple explanation for the anomaly has been found. To check these calibration experiments, a dedicated experiment BEST was performed, utilizing a neutrino source of unprecedented intensity and a detector optimized to increase statistics while providing some information on counting rate as a function of distance from the source. The results BEST obtained are consistent with the earlier solar neutrino calibration experiments, and when combined with those measurements, yield a Ga anomaly with a significance of approximately 4𝜎, under conservative assumptions. But BEST found no evidence of distance dependence and thus no explicit indication of new physics. In this review we describe the extensive campaigns carried out by SAGE, GALLEX/GNO, and BEST to demonstrate the reliability and precision of their experimental procedures, including 71 Ge recovery, counting, and analysis. We also describe efforts to define uncertainties in the neutrino capture cross section, which now include estimates of effects at the ≲ 0.5% level such as radiative corrections and weak magnetism. With the results from BEST, an anomaly remains even if one retains only the transition to the 71 Ge ground state, whose strength is fixed by the known lifetime of 71 Ge. We then consider the new-physics solution most commonly suggested to resolve the Ga anomaly, oscillations into a sterile fourth neutrino, 𝜈 𝑒 → 𝜈 𝑠 . We find such a solution generates substantial tension with several null experiments, owing to the large mixing angle required. While this does not exclude such solutions – the sterile sector might include multiple neutrinos as well as new interactions – it shows the need for more experimental constraints, if we are to make progress in resolving the Ga and other low-energy neutrino anomalies. We conclude by consider the role future low-energy electron-capture sources could play in this effort.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combined experimental setup for spin- and angle-resolved direct and inverse photoemission

We present a combined experimental setup for spin- and angle-resolved direct and inverse photoemission in the vacuum ultraviolet energy range for measurements of the electronic structure below and above the Fermi level. Both techniques are installed in one ultrahigh-vacuum chamber and, as a consequence, allow quasisimultaneous measurements on one and the same sample preparation. The photoemission experiment consists of a gas discharge lamp and an electron energy analyzer equipped with a spin polarization detector based on spin-polarized low-energy electron diffraction. Our homemade inverse-photoemission spectrometer comprises a GaAs photocathode as spin-polarized electron source and Geiger-Mueller counters for photon detection at a fixed energy of 9.9 eV. The total energy resolution of the experiment is better than 50 meV for photoemission and better than 200 meV for inverse photoemission. The performance of our combined direct and inverse-photoemission experiment with respect to angular and energy resolutions is exemplified by the Fermi-level crossing of the Cu(111) L-gap surface state. Spin-resolved measurements of Co films on Cu(001) are used to characterize the Sherman function of the spin polarization detector as well as the spin polarization of our electron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regional Influence of Aerosol Emissions from Wildfires Driven by Combustion Efficiency: Insights from the BBOP Campaign

Abstract Wildfires are important contributors to atmospheric aerosols and a large source of emissions that impact regional air quality and global climate. In this study, wildfire emissions in the Pacific Northwest region of the United States were characterized using real-time measurements near their sources using an aircraft, and farther downwind from a fixed ground site located at the Mt. Bachelor Observatory (~ 2700 m a.s.l.). The characteristics of aerosol emissions were found to depend strongly on the modified combustion efficiency (MCE), a qualitative index of the combustion processes of a fire. Organic aerosol emissions had negative correlations with MCE, whereas the carbon oxidation state of organic aerosol increased with MCE. The relationships between the aerosol properties and MCE were consistent between fresher emissions (~1 hour old) and emissions sampled after atmospheric transport (6 - 45 hours), suggesting that organic aerosol mass loading and chemical properties were strongly influenced by combustion processes at the source and conserved to a significant extent during regional transport. These results suggest that MCE can be a useful metric for describing aerosol properties of regionally transported wildfire emissions and their impacts on regional air quality and global climate.

54 ENVIRONMENTAL SCIENCES↗

RadTrac : A system for detecting, localizing, and tracking radioactive sources in real time.

Within the homeland security and emergency response communities, there is a need for a low-profile system to detect and locate radioactive sources. RadTrac has been developed at Argonne National Laboratory as an integrated system for the detection, localization, identification, and tracking of radioactive sources in real time. The system is based on a network of radiation detectors and advanced signal-processing algorithms. Features include video surveillance, automated tracking, easy setup, and logging of all data and images. This paper describes the advanced algorithms that were developed and implemented for source detection, localization, and tracking in real time. In the physio-spatial integration approach to source localization, counts from multiple detectors are processed according to the underlying physics linking these counts to obtain the probability that a source is present at any point in space. This information is depicted in a probability density function map. This type of depiction allows the results to be presented in a simple, easy-to-understand manner. It also allows for many different complicated factors to be accounted for in a single image as each factor is computed as a probability density in space. These factors include spatial limitations, variable shielding, directional detectors, moving detectors, and different detector sizes and orientations. The utility and versatility of this approach is described in further detail. Advanced signal-processing algorithms have also been incorporated to improve real-time tracking and to increase signal-to-noise ratios including temporal linking and energy binning. Measurements aimed at demonstrating the sensitivity improvements through the use of advanced signal-processing techniques were performed and are presented. Results of tracking weak sources (<100 {micro}Ci {sup 137}Cs) using four fixed-position detectors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Evaluation of Fuel-Reactor Concepts for Advanced LEU Fuel Development

The National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation R&D has commenced a project to evaluate and develop low-enriched uranium (LEU) fuel systems, materials, and fabrication technologies that could be used for compact, advanced LEU (aLEU) fuel, power-producing, high-burnup reactor applications. Potential applications are intended to be off-grid power sources for ship-borne systems and transportable systems to fixed locations, e.g., to a remote base or to a seawater desalination service location. Reactors with these qualities and fuel enrichments between 5 and 20% are atypical. The aLEU Fuel for Nonproliferation Applications Project addresses this technology gap.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scannerless laser range imaging using loss modulation

A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.

47 OTHER INSTRUMENTATION↗

Duty factor variation possibility from 1% to 100% with PKU microwave driven Cs-free volume H{sup −} sources

Microwave driven cesium-free volume H{sup −} sources, that have the ability to deliver tens of mA H{sup −} at 35 keV both in CW and 10% duty factor (100 Hz/1 ms), were developed at Peking University (PKU) [S. X. Peng et al., in Proceeding of IPAC 2015, WEPWA027, Richmond, Virginia, USA, 3–8 May 2015]. Recently, special efforts were paid on the investigation of duty factor variation possibility from 1% to 100% with them. Most of the experiments were carried out with a pulsed length (τ) of 1 ms and different intervals of 99 ms, 49 ms, 39 ms, 29 ms, 19 ms, 9 ms, 4 ms, 2 ms, 1 ms, 0.5 ms, and 0 ms, respectively. Other experiments were focused on CW operation and fixed duty factor of 1%. Experimental results prove that PKU H{sup −} sources can deliver tens of mA H{sup −} at duty factor from 1% to 100%. The RF power efficiency increases steadily with the increasing of duty factor from 1% to CW at a fixed pulsed length. Under a given duty factor and pulsed length, RF power efficiency keeps constant and the H{sup −} current increases with RF power linearly. Details will be presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How Many Muons Do We Need to Store in a Ring For Neutrino Cross-Section Measurements?

Analytical estimate of the number of muons that must decay in the straight section of a storage ring to produce a neutrino & anti-neutrino beam of sufficient intensity to facilitate cross-section measurements with a statistical precision of 1%. As we move into the era of precision long-baseline {nu}{sub {mu}} {yields} {nu}{sub e} and {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e} measurements there is a growing need to precisely determine the {nu}{sub e} and {bar {nu}}{sub e} cross-sections in the relevant energy range, from a fraction of 1 GeV to a few GeV. This will require {nu}{sub e} and {bar {nu}}{sub e} beams with precisely known fluxes and spectra. One way to produce these beams is to use a storage ring with long straight sections in which muon decays ({mu}{sup -} {yields} e{sup -}{nu}{sub {mu}}{bar {nu}}{sub e} if negative muons are stored, and {nu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} if positive muons are stored) produce the desired beam. The challenge is to capture enough muons in the ring to obtain useful neutrino and anti-neutrino fluxes. Early proposals to use a muon storage ring for neutrino oscillation experiments were based upon injecting 'high energy' charged pions into the ring which then decayed to create stored muons. These proposals were hampered by lack of sufficient intensity to pursue the physics. The Neutrino Factory proposal in 1997 was designed to fix this problem by using a Muon Collider class 'low energy' muon source to capture many more pions at low energy, allow them to decay in an external decay channel, manipulate their phase space to capture as many muons as possible within the acceptance of an accelerator, and then accelerate to the energy of choice before injecting into a specially designed ring with long straight sections. All this technology would do a wonderful job in fixing the intensity problem, but at a price that excludes this solution from being realized in the short term. The question that we are now faced with is whether the older, lower intensity 'parasitic' muon storage ring based on 'high energy' pion decays can, with suitable modification, produce sufficient intensity to measure the desired cross-sections. Fortunately, the intensity requirements for cross-section measurements are less demanding than the corresponding requirements for oscillation measurements, so there is hope. To fuel the discussion, in this note we consider the design goal: how many muons do we need to store?

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current State of Neutron Source Term Calculations

SOURCES-4C has some significant deficiencies that are mostly due to problems with the default data libraries that it uses. Some research groups have modified these libraries to fix most of the problems, but not all of them. Adding modern data libraries to SOURCES-4C is one of the most promising approaches to resolving these issues. Other promising options include using either NEDIS or a GEANT4 tool. Both of these codes approximately match the accuracy of the modified SOURCES-4C code. The NEDIS code is Russian. The GEANT4 tool might be computationally slow and it might also no longer be actively maintained. There are a handful of other (α,n) codes, but they are not accurate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A low phase noise microwave source for atomic spin squeezing experiments in {sup 87}Rb

We describe and characterize a simple, low cost, low phase noise microwave source that operates near 6.800 GHz for agile, coherent manipulation of ensembles of {sup 87}Rb. Low phase noise is achieved by directly multiplying a low phase noise 100 MHz crystal to 6.8 GHz using a nonlinear transmission line and filtering the output with custom band-pass filters. The fixed frequency signal is single sideband modulated with a direct digital synthesis frequency source to provide the desired phase, amplitude, and frequency control. Before modulation, the source has a single sideband phase noise near -140 dBc/Hz in the range of 10 kHz-1 MHz offset from the carrier frequency and -130 dBc/Hz after modulation. The resulting source is estimated to contribute added spin-noise variance 16 dB below the quantum projection noise level during quantum nondemolition measurements of the clock transition in an ensemble 7 x 10{sup 5} {sup 87}Rb atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wideband dynamic radio spectra of two ultra-cool dwarfs

A number of radio-loud ultra-cool dwarf (UCD) stars exhibit both continuous broadband and highly polarized pulsed radio emission. In order to determine the nature of the emission and the physical characteristics in the source region, we have made multi-epoch, wideband spectral observations of TVLM 0513-46 and 2M 0746+20. We combine these observations with archival radio data to fully characterize both the temporal and spectral properties of the radio emission. The continuum spectral energy distribution can be well modeled using gyrosynchrotron emission from mildly relativistic electrons in a dipolar field. The pulsed emission exhibits a variety of time-variable characteristics, including frequency drifts, frequency cutoffs, and multiple pulses per period. For 2M 0746+20 we determine a pulse period consistent with previously determined values. We modeled locations of pulsed emission using an oblique rotating magnetospheric model with beamed electron-cyclotron maser (ECM) sources. The best-fit models have narrow ECM beaming angles aligned with the local source magnetic field direction, except for one isolated burst from 2M 0746+20. For TVLM 0513-46, the best-fit rotation axis inclination is nearly orthogonal to the line of sight. For 2M 0746+20 we found a good fit using a fixed inclination i=36{sup ∘}, determined from optical observations. For both stars the ECM sources are located near feet of magnetic loops with radial extents 1.2R{sub s}–2.7R{sub s} and surface fields 2.2–2.5 kG. These results support recent suggestions that radio over-luminous UCDs have a global “weak field” non-axisymmetric magnetic topologies.

79 ASTRONOMY AND ASTROPHYSICS↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Effects of EMF Emissions from Cables and Junction Boxes on Marine Species

Studies have shown that diverse aquatic species are electrosensitive. Many fishes, and marine mammals, can either detect, navigate by, or are affected by electromagnetic fields (EMF) with various sensitivities, and their behavior may be impacted by unnatural EMF emissions in the water column. Sharks, rays and skates are known to have the highest sensitivity to electric fields. Electric field emissions in the range 0.5–100 micro volt/m appear to attract them, and emissions over 100 micro volt/m to repulse them. A marine hydrokinetic MHK device will have multiple components and associated multiple submarine cables on the seafloor and running through the water column and would potentially increase the level of EMF emissions to which the marine species at the site may be exposed to. There are therefore concerns amongst stakeholders that EMF emissions associated with MHK devices and their components may act as barriers to species migration, cause disorientation, change community compositions and ecosystems, and that they may attract sharks, leading to a local increase in the risk of shark attacks. However, field data to validate and model potential relationships between observed responses and the EMF emissions in situ are sparse. A program of experimental field surveys were conducted off the coast of South Florida, USA to characterize the electromagnetic field (EMF) emissions in the water column from a submarine cable, and to monitor for responses of local aquatic species. The field surveys were conducted at the South Florida Ocean Measurement Facility (SFOMF) off Fort Lauderdale, which is a cabled offshore in-water navy range. It consists of multiple active submarine power cables and a number of junction boxes, with the capability to transmit AC/DC power at a range of strength and frequencies. The site includes significant marine life activities and community structure, including highly mobile species, such as sharks, stingrays, mammals and turtles. SFOMF therefore typifies a setting representative of an offshore location where a MHK device may be sited. Background electromagnetic field (EMF) levels and EMF emissions due to submarine cables were measured using a custom E-field sensor and a commercial magnetometer deployed from an autonomous underwater vehicle (AUV) at various fixed altitudes above the seafloor. EMF signatures detected from power cables and junction boxes are contrasted against ambient background levels and other EMF sources. The potential responses of local marine species were observed at selected representative locations using divers on SCUBA, complemented with fixed cameras on the sea bottom and by a set of video cameras mounted on the AUV. The objectives of the study were: 1) to characterize the EMF emission levels associated with submarine cables 2) to monitor potential responses of aquatic animals to the emissions and 3) to develop an associated database of field observations. As control, observations of EMF levels and in situ marine species were conducted with power in the cable turned off. Good quality measurements of EMF emissions were obtained using the mobile AUV platform and the data from the surveys were used to develop contour maps of the EMF levels in the water column above the live cable as well as to provide information about how the field decays away from the cable. The measurements show good agreement with theoretical models of the how EMF levels decay away from the cable in deep and shallow water environment. Electric fields in excess of 200µV/m were measured in the vicinity of the cable during the power on state. Quarterly surveys by SCUBA divers were conducted, using point and transect count methods, over a period of one year at three locations, one at a shallow site where the water depth is approximately 5m, and the other at the Barracuda Reef where the water depth is approximately 10m. The sampling results were analyzed to determine if the presence of an SFOMF generated EMF alters: (1) abundance, species richness, and assemblage structure of coral reef fishes, (2) the behavior of fishes including elasmobranchs, and (3) the distribution of marine turtles and mammals. Diver observations were also used in attempt to discern if there were any noticeable organismal responses during the transitional period between ambient OFF to energized AC or DC power states, and video footage was intended to augment the in-situ visual survey data and aid in interpretation of the results. Comparisons are provided between observation datasets between the three sites and between the point and transect count methods. Presence of several individual elasmobranch species, including sharks and stingrays, were recorded during the surveys. No apparent effect on richness could be discerned between the power on and off states. No apparent sudden animal movements were observed during transitions between power states.

16 TIDAL AND WAVE POWER↗

A room temperature electron cyclotron resonance ion source for the DC-110 cyclotron

The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intensive Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. This article reviews the design and construction of DECRIS-5 ion source along with some initial commissioning results.

43 PARTICLE ACCELERATORS↗

A Quick Overview of the Extended Feynman Project

The low natural background rates and the penetrating nature of neutron radiation makes neutron detection a good method for quantifying and accounting for large amounts of special nuclear material capable of neutron induced fission and fission chains. Fission is one of the few natural processes that produces time-correlated neutrons, the others are spallation-type processes (e.g. (n,Xn), cosmic induced background, etc) which have low but measurable rates in common terrestrial material. The high rates of most transuranic spontaneous fission sources of even a gram or less usually swamp any cosmic induced background rate but even Kilogram quantities of natural uranium produce neutrons only on the same order as that of the cosmic generated background flux. However the primary characteristic of special nuclear material is its ability to fission and to support fission chains through neutron induced fission. This means that neutrons produced from fission are not produced randomly singly but rather in time-correlated bursts. Almost from the beginning of the atomic age, the measurement of time-correlated neutrons has been used to detect and quantify fission and fission processes. Feynman himself proposed a method, the grandfather of what is used today, to compare correlation rates of neutron flux in a fixed time to that which would be expected of a random neutron source. The larger variance (broader distribution) as compared to a random distribution is a tell-tale sign of correlated production and commonly used as signature of fission and more importantly fission chains, the broader the distribution (and its departure from a random distribution) the higher the multiplication. Feynman’s original method was used to determine the criticality of the first reactor and other critical or near critical systems. We at LLNL have been developing this concept over the past decade and a half and have employed it for the detection and assessment of nuclear materials. Our method for doing this involved generating a theoretical prediction of what we might expect to see, given a neutron source (spontaneous fission with a nubar, or alpha-n) and a possibly multiplying material (Plutonium or Uranium) and comparing it to a measured result and deducing from this what it is we are measuring. We first developed these methods for portable (low efficiency) thermal neutron detectors that were used predominantly for emergency response situations and we have applied some of these techniques with thermal neutron detectors to arms control verification and authentication, for example verifying that there are multiplying quantities of plutonium in an unknown object. In recent years we have been exploring the use of fast neutrons using liquid scintillator cells with Pulse Shape Discrimination (PSD) and in this project we developing both the theory of fast particle production from fission and fission chains and the use of fast particle detection methods primarily for arms control verification and authentication, but for other uses. We have found that fast detection has many advantages, primarily because the speed of the detection (nanoseconds) preserves the original time scale of the particles produced by fission (and more importantly from induced fission) but also because the fast time scales allow for considering much shorter measurement times (binning) that greatly reduce the pollution of random correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of interferometer system for Keda Torus eXperiment using terahertz solid-state diode sources

A solid-state source based terahertz (THz) interferometer diagnostic system has been designed and characterized for the Keda Torus eXperiment (KTX). The THz interferometer utilizes the planar diodes based frequency multiplier (X48) to provide the probing beam at fixed frequency 0.650 THz, and local oscillator is provided by an independent solid-state diode source with tunable frequency (0.650 THz +/− 10 MHz). Both solid-state sources have approximately 1 mW power. The planar-diode mixers optimized for high sensitivity, ∼750 mV/mW, are used in the heterodyne detection system, which permits multichannel interferometer on KTX with a low phase noise. A sensitivity of {sub min} = 4.5 × 10{sup 16} m{sup −2} and a temporal resolution of 0.2 μs have been achieved during the initial bench test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculation of helical tomotherapy dose delivery

Helical tomotherapy delivers intensity modulated radiation therapy using a binary multileaf collimator (MLC) to modulate a fan beam of radiation. This delivery occurs while the linac gantry and treatment couch are both in constant motion, so the beam describes, from a patient/phantom perspective, a spiral or helix of dose. The planning system models this continuous delivery as a large number (51) of discrete gantry positions per rotation, and given the small jaw/fan width setting typically used (1 or 2.5 cm) and the number of overlapping rotations used to cover the target (pitch often <0.5), the treatment planning system (TPS) potentially employs a very large number of static beam directions and leaf opening configurations to model the modulated fields. All dose calculations performed by the system employ a convolution/superposition model. In this work the authors perform a full Monte Carlo (MC) dose calculation of tomotherapy deliveries to phantom computed tomography (CT) data sets to verify the TPS calculations. All MC calculations are performed with the EGSnrc-based MC simulation codes, BEAMnrc and DOSXYZnrc. Simulations are performed by taking the sinogram (leaf opening versus time) of the treatment plan and decomposing it into 51 different projections per rotation, as does the TPS, each of which is segmented further into multiple MLC opening configurations, each with different weights that correspond to leaf opening times. Then the projection is simulated by the summing of all of the opening configurations, and the overall rotational treatment is simulated by the summing of all of the projection simulations. Commissioning of the source model was verified by comparing measured and simulated values for the percent depth dose and beam profiles shapes for various jaw settings. The accuracy of the MLC leaf width and tongue and groove spacing were verified by comparing measured and simulated values for the MLC leakage and a picket fence pattern. The validated source and MLC configuration were then used to simulate a complex modulated delivery from fixed gantry angle. Further, a preliminary rotational treatment plan to a delivery quality assurance phantom (the 'cheese' phantom) CT data set was simulated. Simulations were compared with measured results taken with an A1SL ionization chamber or EDR2 film measurements in a water tank or in a solid water phantom, respectively. The source and MLC MC simulations agree with the film measurements, with an acceptable number of pixels passing the 2%/1 mm gamma criterion. 99.8% of voxels of the MC calculation in the planning target volume (PTV) of the preliminary plan passed the 2%/2 mm gamma value test. 87.0% and 66.2% of the voxels in two organs at risk (OARs) passed the 2%/2 mm tests. For a 3%/3 mm criterion, the PTV and OARs show 100%, 93.2%, and 86.6% agreement, respectively. All voxels passed the gamma value test with a criterion of 5%/3 mm. The TomoTherapy TPS showed comparable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗