Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Utilizing expert systems for satellite monitoring and control

Spacecraft analysts in the spacecraft control center for the Cosmic Background Explorer (COBE) satellite are currently utilizing a fault-isolation expert system developed to assist in the isolation and correction of faults in the communications link. This system, the communication link expert assistance resource (CLEAR), monitors real time spacecraft and ground systems performance parameters in search of configuration discrepancies and communications link problems. If such a discrepancy or problem is isolated, CLEAR alerts the analyst and provides advice on how to resolve the problem swiftly and effectively. The CLEAR system is the first real time expert system to be used in the operational environment of a satellite control center at the NASA Goddard Space Flight Center. Clear has not only demonstrated the utility and potential of an expert system in the demanding environment of a satellite control center, but also has revealed many of the pitfalls and deficiencies of development of expert systems. One of the lessons learned from this and other initial expert system projects is that prototypes can often be developed quite rapidly, but operational expert systems require considerable effort. Development is generally a slow, tedious process that typically requires the special skills of trained programmers. Due to the success of CLEAR and several other systems in the control center domain, a large number of expert systems will certainly be developed to support control center operations during the early 1990's. To facilitate the development of these systems, a project was initiated to develop an integrated, domain-specific tool, the generic spacecraft analyst assistent (GenSAA), that alows the spacecraft analysts to rapidly create simple expert systems themselves. By providing a highly graphical point-and-select method of system development, GenSAA allows the analyst to utilize and/or modify previously developed rule bases and system components; thus, facilitating software reuse and reducing development time and effort.

Hughes, Peter M.↗

Lunar Landing Operational Risk Model

Characterizing the risk of spacecraft goes beyond simply modeling equipment reliability. Some portions of the mission require complex interactions between system elements that can lead to failure without an actual hardware fault. Landing risk is currently the least characterized aspect of the Altair lunar lander and appears to result from complex temporal interactions between pilot, sensors, surface characteristics and vehicle capabilities rather than hardware failures. The Lunar Landing Operational Risk Model (LLORM) seeks to provide rapid and flexible quantitative insight into the risks driving the landing event and to gauge sensitivities of the vehicle to changes in system configuration and mission operations. The LLORM takes a Monte Carlo based approach to estimate the operational risk of the Lunar Landing Event and calculates estimates of the risk of Loss of Mission (LOM) - Abort Required and is Successful, Loss of Crew (LOC) - Vehicle Crashes or Cannot Reach Orbit, and Success. The LLORM is meant to be used during the conceptual design phase to inform decision makers transparently of the reliability impacts of design decisions, to identify areas of the design which may require additional robustness, and to aid in the development and flow-down of requirements.

Mattenberger, Chris↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Analysis and Detection in Microgrids with High PV Penetration

In this report we focus on analyzing current-controlled PV inverters behaviour under faults in order to develop fault detection schemes for microgrids with high PV penetration. Inverter model suitable for steady state fault studies is presented and the impact of PV inverters on two protection elements is analyzed. The studied protection elements are superimposed quantities based directional element and negative sequence directional element. Additionally, several non-overcurrent fault detection schemes are discussed in this report for microgrids with high PV penetration. A detailed time-domain simulation study is presented to assess the performance of the presented fault detection schemes under different microgrid modes of operation.

30 DIRECT ENERGY CONVERSION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Evaluating the Incident Energy of Arcs in Photovoltaic DC Systems: Comparison Between Calculated and Experimental Data

Solar Photovoltaic (PV) systems have permeated the energy generation world at a very high rate, some of the safety codes and standards are still lagging in accurately assessing the hazards and risks associated with PV array arcing energies. Safety professionals and maintenance workers using NFPA 70E have utilized the Doan, Stokes & Oppenlander or Enrique models, meant to determine arc energies in DC power systems using the maximum power method. These methods may lead to an overestimate of energy available in PV systems during a fault. Since PV modules/arrays are non-linear, current limited DC devices, some of these calculation methods may not accurately predict fault energy. This paper will validate current arc energy models for PV systems by comparing experimental and calculated data. Additionally, this data will help modify the current NFPA 70E models related to smaller solar arrays. Understanding where the real safety threshold for DC arc flash in PV systems exists will help maintenance and safety professionals better prepare for a variety of work related activities. This paper will analyze real arc data taken for PV systems <1000VDC and <60amps and compare this to the calculated incident energy models, to include 70E. Thus, using these comparisons, it may be possible to reduce the safety hazard severity and thus relax the PPE requirements for installation and maintenance crews.

14 SOLAR ENERGY↗

A Hybrid DC Fault Primary Protection Algorithm for Multi-Terminal HVdc Systems

Protection against dc faults is one of the main technical hurdles faced when operating converter-based HVdc systems. Protection becomes even more challenging for multi-terminal dc (MTdc) systems with more than two terminals/converter stations. In this paper, a hybrid primary fault detection algorithm for MTdc systems is proposed to detect a broad range of failures. Sensor measurements, i.e., line currents and dc reactor voltages measured at local terminals, are first processed by a top-level context clustering algorithm. For each cluster, the best fault detector is selected among a detector pool according to a rule resulting from a learning algorithm. The detector pool consists of several existing detection algorithms, each performing differently across fault scenarios. The proposed hybrid primary detection algorithm: i) offers superior performance compared to an individual detector through a data-driven approach; ii) detects all major fault types including pole-to-pole (P2P), pole-to-ground (P2G), and external dc faults; iii) identifies faults with various fault locations and impedances; iv) is more robust to noisy sensor measurements compared to existing methods; v) does not require exhaustive simulation and sampling for training the model. Performance and effectiveness of the proposed algorithm are evaluated and verified based on time-domain simulations in the PSCAD/EMTDC software environment. The results confirm satisfactory operation, accuracy, and detection speed of the proposed algorithm under various fault scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous reconfigurable virtual sensing system for cyber-attack neutralization

An industrial asset may be associated with a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that at least one abnormal monitoring node is currently being attacked or experiencing a fault. A virtual sensing estimator may continuously execute an adaptive learning process to create or update virtual sensor models for the monitoring nodes. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, the virtual sensing estimator may be dynamically reconfigured to estimate a series of virtual node values for the abnormal monitoring node or nodes based on information from normal monitoring nodes and appropriate virtual sensor models. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

97 MATHEMATICS AND COMPUTING↗

Adaptive, self-tuning virtual sensing system for cyber-attack neutralization

An industrial asset may have a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that an abnormal monitoring node is currently being attacked or experiencing a fault. An autonomous, resilient estimator may continuously execute an adaptive learning process to create or update virtual sensor models for that monitoring node. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, a level of neutralization may be automatically determined. The autonomous, resilient estimator may then be dynamically reconfigured to estimate a series of virtual node values based on information from normal monitoring nodes, appropriate virtual sensor models, and the determined level of neutralization. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

Abbaszadeh, Masoud↗

Bridging faults in BiCMOS circuits

Combining the advantages of CMOS and bipolar, BiCMOS is emerging as a major technology for many high performance digital and mixed signal applications. Recent investigations revealed that bridging faults can be a major failure mode in IC's. Effects of bridging faults in BiCMOS circuits are presented. Bridging faults between logical units without feedback and logical units with feedback are considered. Several bridging faults can be detected by monitoring the power supply current (I(sub DDQ) monitoring). Effects of bridging faults and bridging resistance on output logic levels were examined along with their effects on noise immunity.

Menon, Sankaran M.↗

Keeping checkpoint/restart viable for exascale systems.

Next-generation exascale systems, those capable of performing a quintillion (10{sup 18}) operations per second, are expected to be delivered in the next 8-10 years. These systems, which will be 1,000 times faster than current systems, will be of unprecedented scale. As these systems continue to grow in size, faults will become increasingly common, even over the course of small calculations. Therefore, issues such as fault tolerance and reliability will limit application scalability. Current techniques to ensure progress across faults like checkpoint/restart, the dominant fault tolerance mechanism for the last 25 years, are increasingly problematic at the scales of future systems due to their excessive overheads. In this work, we evaluate a number of techniques to decrease the overhead of checkpoint/restart and keep this method viable for future exascale systems. More specifically, this work evaluates state-machine replication to dramatically increase the checkpoint interval (the time between successive checkpoint) and hash-based, probabilistic incremental checkpointing using graphics processing units to decrease the checkpoint commit time (the time to save one checkpoint). Using a combination of empirical analysis, modeling, and simulation, we study the costs and benefits of these approaches on a wide range of parameters. These results, which cover of number of high-performance computing capability workloads, different failure distributions, hardware mean time to failures, and I/O bandwidths, show the potential benefits of these techniques for meeting the reliability demands of future exascale platforms.

99 GENERAL AND MISCELLANEOUS↗

Condition monitoring of permanent magnet AC machines for all-electric transportation systems: State of the art

The current state of the art on emerging and efficient techniques for condition monitoring of permanent magnet (PM) alternating-current (AC) machines deployed in electric vehicle (EV) applications is presented. The discussion includes the most common and specific types of faults in PM motors, such as rotor demagnetisation and stator inter-turn faults, respectively. Fault indicators, such as voltage (v s ) and current (i s ) signals and machine signatures based on motor back electromotive force (EMF) (E B ) and magnetic flux (φ), are taken into account as a measuring quantity in diagnosing motor faults. Other signatures, including thermal analysis, acoustic noise, and vibrations, are also illustrated as some of the emerging techniques in estimating the performance of EV motors while under operations. In addition, various fault modelling methods, condition monitoring techniques, and comprehensive approaches applied in diagnosing the effect of machine faults during its incipient stages are illustrated. Since most of the fault diagnostic techniques discussed here include only machine-based quantities as fault indices/indicators, the provided solutions are therefore found to be more reliable and accurate for diagnosing the motor faults. This comprehensive review study is inclusive of the existing fault diagnostic techniques, which are currently employed in industrial and commercial practices, in addition to the new methodologies proposed by the authors. All the given condition monitoring schemes therefore seem significantly vital in estimating the state of health of PM AC machines while under operation in all-electric transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Deep Convolutional Neural Networks for Distribution System Fault Classification

Faults happen very frequently in distribution systems. Identifying fault types and phases are of critical importance for outage management, fault location, and service restoration. However, this task becomes very challenging due to measurement scarcity in distribution systems. This paper is among the first few that applies deep learning techniques in distribution system fault classification. Specifically, a sequential Convolutional Neural Network(CNN)-based classifier is developed to identify fault buses and phases. The input to the CNN is the steady-state voltage and current data measured at substations. The fault identification is modeled as a multi-label classification problem. Training data under various fault scenarios are obtained in OpenDSS and Gaussian noises are added to mimic measurement errors. A case study in IEEE 13-feeder test system is conducted with single and multiple bus faults scenarios. Numerical results demonstrate the high accuracy and fast computation of the proposed deep CNN-based fault classification.

Tian, Guanyu↗

Early Fault Detection in Nuclear Systems: A Digital Engineering Approach

Nuclear energy systems present unique challenges in terms of ensuring safety, reliability, and efficiency during their design and operation. Early fault detection is critical for mitigating risks and fostering system resilience. However, current methods often fall short at identifying faults during early stages, potentially leading to costly delays and safety risks. The present work proposes a comprehensive digital engineering approach that leverages digital twins, digital threads, model-based systems engineering, artificial intelligence, and immersive extended reality to support early fault detection in nuclear systems. Through a series of case studies, we highlight specific gaps in the fault detection mechanisms of traditional nuclear design and operation processes, then demonstrate a suite of solutions we are working to implement to address these shortcomings in similar projects. Our findings suggest that a digital engineering approach to design and operation can significantly improve fault detection, ultimately leading to reductions in risk.

42 - ENGINEERING↗

Fundamental-Frequency Reactive Circulating Current Injection for Capacitor Voltage Balancing in Hybrid-MMC HVDC Systems During Riding Through PTG Faults

Here, this article presents a comprehensive analysis and a novel solution for the discharge problem on the half-bridge submodules' (HBSMs') capacitors in the hybrid modular multilevel converter (MMC)-based high-voltage direct current transmission systems under a long-term (e.g., several minutes or longer) pole-to-ground fault condition. The mechanism of this issue is analyzed, and then a solution based on fundamental-frequency reactive circulating current (FFRCC) injection is proposed. The influence of FFRCC injection is analyzed in terms of the fluctuated arm capacitor energy and the current stress of semiconductors. Moreover, an enhanced arm voltage modulation method based on HBSMs and full-bridge submodules coordinate control is proposed to accelerate the capacitor voltage balance of HBSMs. Finally, the performance of the proposed control strategy is verified by the simulation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗