Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exposure time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Radium Dial Workers: Back to the Future

This report reviews the history of the radium dial workers in the United States, summarizes the scientific progress made since the last evaluation in the early 1990s, and discusses current progress in updating the epidemiologic cohort and applying new dosimetric models for radiation risk assessment. The discoveries of radiation and radioactivity led quickly to medical and commercial applications at the turn of the 20th century, including the development of radioluminescent paint, made by combining radium with phosphorescent material and adhesive. Workers involved with the painting of dials and instruments included painters, handlers, ancillary workers, and chemists who fabricated the paint. Dial painters were primarily women and, prior to the mid to late 1920s, would use their lips to give the brush a fine point, resulting in high intakes of radium. The tragic experience of the dial painters had a significant impact on industrial safety standards, including protection measures taken during the Manhattan Project. The dial workers study has formed the basis for radiation protection standards for intakes of radionuclides by workers and the public. The mortality experience of 3,276 radium dial painters and handlers employed between 1913-1949 is being determined through 2019. The last epidemiologic follow-up was 30 years ago when most of these workers were still alive. Nearly 65% were born before 1920, 37.5% were teenagers when first hired, and nearly 50% were hired before 1930 when the habit of placing brushes in mouths essentially stopped. Comprehensive dose reconstruction techniques are being applied to estimate organ doses for each worker related to the intake of 226Ra, 228Ra, and associated photon exposures. Time dependent dose-response analyses will estimate lifetime risks for specific causes of death. The study of radium dial workers is part of the Million Person Study of low-dose health effects that is designed to evaluate radiation risks among healthy American workers and veterans. Despite being one of the most important and influential radiation effects studies ever conducted, shifting programmatic responsibilities and declining funding led to the termination of the radium program of studies in the early 1990s. Renewed interest and opportunity have arisen. With scientific progress made in dosimetric methodology and models, the ability to perform a study over the entire life span, and the potential applicability to other scenarios such as medicine, environmental contamination and space exploration, the radium dial workers have once again come to the forefront.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrical breakdown dynamics in an argon bubble submerged in conductive liquid for nanosecond pulsed discharges

Abstract This study delves into the dynamics of cold atmospheric plasma and their interaction within conductive solutions under the unique conditions of nanosecond pulsed discharges (22 kV peak voltage, 10 ns FWHM, 4.5 kV ns −1 rate-of-rise). The research focuses on the electrical response, breakdown, and discharge propagation in an argon bubble, submerged in a NaCl solution of varying conductivity. Full or partial discharges were observed at conductivities of 1.5 µ S cm −1 (deionized water) to 1.6 mS cm −1 , but no breakdown was observed at 11.0 mS cm −1 when reducing the electrode gap. It is demonstrated that at higher conductivity electric breakdown is observed only when the gas bubble comes into direct contact with the electrode and multiple emission nodes were observed at different timescales. These nodes expanded in the central region of the bubble over timescales longer than the initial high-voltage pulse. This work offers a temporal resolution of 2 ns exposure times over the first 30 ns of the initial voltage pulse, and insight into plasma formation over decaying reflected voltage oscillations over 200 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of the ERO2.0 code using W7-X and JET experiments and predictions for ITER operation

Abstract The paper provides an overview of recent modelling of global material erosion and deposition in the fusion devices Wendelstein 7-X (W7-X), JET and ITER using the Monte-Carlo code ERO2.0. For validating the modelling tool in a three-dimensional environment, W7-X simulations are performed to describe carbon erosion from the graphite test divertor units, which were equipped in operational phase OP 1.2 and analysed post-mortem. Synthetic spectroscopy of carbon line emission is compared with experimental results from the divertor spectrometer measurement system, showing a good agreement in the e-folding lengths in the radial intensity profiles of carbon. In the case of metallic wall materials, earlier modelling of the Be/W environment in JET and ITER is revisited and extended with an updated set of sputtering and reflection data, as well as including the mixing model for describing the Be/W dynamics in the divertor. Motivated by recent H/D/T isotope experiments in JET, limited and diverted configuration pulses are modelled, showing the expected trend of both Be and W erosion increasing with isotope mass. For the JET diverted configuration pulses, it is shown that Be migrates predominantly to the upper part of the inner divertor where it initially leads to strong W erosion. With longer exposure time, the growth of a Be deposited layer leads to a reduction of W erosion in that region. A similar trend is observed in simulations of the ITER baseline Q = 10 scenario, however with a more symmetric Be migration pattern leading to deposition also on the outer divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗

Difficult Measurements of Materials Systems at Cryogenic Temperatures: Cryo-EELS and Cryo-4D-STEM

Scanning/transmission electron microscopy (S/TEM) in materials science has traditionally been accomplished at room temperature due to their solid state in this temperature range and relative insensitivity to radiolysis damage. Cooling to cryogenic temperatures tended to introduce instabilities such as vibration and drift and can lead to the buildup of carbon contamination or ice reducing contrast. The need to expand TEM experimental techniques into new fields such as quantum and battery materials led to new efforts to reduce these instabilities while achieving temperatures at or well below liquid nitrogen (77 K). Further, developments in detector and spectrometer technology brought new capabilities for high resolution electron energy loss spectroscopy (EELS) and scanning nanodiffraction (4D-STEM). These experimental modalities can require even tighter controls of drift, vibration, and exposure time. Here this presentation will discuss accomplishing difficult experiments at cryogenic temperatures in honor of the late Dr. Lena Kourkoutis who inspired and led many such experiments.

36 MATERIALS SCIENCE↗

Imaging systematics and clustering of DESI main targets

ABSTRACT We evaluate the impact of imaging systematics on the clustering of luminous red galaxies (LRG), emission-line galaxies (ELG), and quasars (QSO) targeted for the upcoming Dark Energy Spectroscopic Instrument (DESI) survey. Using Data Release 7 of the DECam Legacy Survey, we study the effects of astrophysical foregrounds, stellar contamination, differences between north galactic cap and south galactic cap measurements, and variations in imaging depth, stellar density, galactic extinction, seeing, airmass, sky brightness, and exposure time before presenting survey masks and weights to mitigate these effects. With our sanitized samples in hand, we conduct a preliminary analysis of the clustering amplitude and evolution of the DESI main targets. From measurements of the angular correlation functions, we determine power law fits $r_0 = 7.78 \pm 0.26\, h^{-1}$Mpc, γ = 1.98 ± 0.02 for LRGs and $r_0 = 5.45 \pm 0.1\, h^{-1}$Mpc, γ = 1.54 ± 0.01 for ELGs. Additionally, from the angular power spectra, we measure the linear biases and model the scale-dependent biases in the weakly non-linear regime. Both sets of clustering measurements show good agreement with survey requirements for LRGs and ELGs, attesting that these samples will enable DESI to achieve precise cosmological constraints. We also present clustering as a function of magnitude, use cross-correlations with external spectroscopy to infer dN/dz and measure clustering as a function of luminosity, and probe higher order clustering statistics through counts-in-cells moments.

79 ASTRONOMY AND ASTROPHYSICS↗

High-frequency gravitational wave detection by the BREAD experiment

The use of experiments searching for light axion dark matter as high-frequency gravitational wave detectors has garnered increasing attention in recent years. We explore the capabilities of the Broadband Reflector Experiment for Axion Detection (BREAD) in probing the GW parameter space and study the directional dependence of its coverage. This detector can investigate frequencies ranging from 0.05 to 200 THz. We find that by employing single photon detectors, BREAD is sensitive to GWs with characteristic strains as low as 10 −21 at 0.1 THz and 10 −25 at 200 THz with a year exposure time, making it competitive with other proposals operating at similar frequencies.

axions↗

Measurement of directional muon beams generated at the Berkeley Lab Laser Accelerator

We present the detection of directional muon beams produced using a PW laser facility at the Lawrence Berkeley National Laboratory. The muon source is a multi-GeV electron beam generated in a laser-plasma accelerator interacting with a high- converter target. The GeV photons resulting from the interaction are converted into a high-flux, directional muon beam via pair production. By employing scintillators to capture delayed events, we were able to identify the produced muons and characterize the source. Using theoretical knowledge of the muon production process combined with simulations that are in excellent agreement with the experiments, we demonstrate that laser-plasma accelerators have the capability of generating electron beams with characteristics suitable to produce GeV-scale muons that offer unique advantages with respect to the cosmic background. Laser-plasma-accelerator-based muon sources can therefore enhance muon imaging applications thanks to their compactness, directionality, and high yields, which reduce the exposure time by orders of magnitude compared to cosmic ray muons. Using the eant4-based simulation code we developed to gain insight into the experimental results, we can design future experiments and applications based on LPA-generated muons.

Terzani, Davide↗

Intergalactic magnetic field studies by means of γ -ray emission from GRB 190114C

The presence of delayed GeV emission after a strong transient, such as a gamma-ray burst (GRB), in the very-high energy (VHE) E > 100 GeV band can be the signature of a nonzero magnetic field in the intergalactic medium. Here we used a synchrotron self-Compton multiwavelength model to infer an analytical description of the intrinsic VHE spectrum (corrected for absorption by the extragalactic background light) of GRB 190114C to predict the light curves and spectral energy distributions of the delayed emission with Monte Carlo simulations for different intergalactic magnetic field (IGMF) configurations (strengths B = 8 × 10 -21 G, 10 -20 G, 3 × 10 -20 G and correlation length $\lambda$ > 1 Mpc), and compared them with the Fermi Large Area Telescope (Fermi LAT) limits computed for several exposure times. We found that the Fermi LAT is not sensitive enough to constrain any IGMF strengths using GRB 190114C.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Exotic Dark Matter Search with the Majorana Demonstrator

With excellent energy resolution and ultralow-level radiogenic backgrounds, the high-purity germanium detectors in the enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos ν s → ν a . We report new limits on fermionic dark matter absorption ( χ + A → ν + A ) and sub-GeV DM-nucleus 3 → 2 scattering ( χ + χ + A → ϕ + A ), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1–100)-keV low-energy region of a 37.5-kg y exposure collected by the between May 2016 and November 2019 using a set of Ge 76 -enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

The AUREX cell: a versatile operando electrochemical cell for studying catalytic materials using X-ray diffraction, total scattering and X-ray absorption spectroscopy under working conditions

Understanding the structure–property relationship in electrocatalysts under working conditions is crucial for the rational design of novel and improved catalytic materials. This paper presents the Aarhus University reactor for electrochemical studies using X-rays (AUREX) operando electrocatalytic flow cell, designed as an easy-to-use versatile setup with a minimal background contribution and a uniform flow field to limit concentration polarization and handle gas formation. The cell has been employed to measure operando total scattering, diffraction and absorption spectroscopy as well as simultaneous combinations thereof on a commercial silver electrocatalyst for proof of concept. This combination of operando techniques allows for monitoring of the short-, medium- and long-range structure under working conditions, including an applied potential, liquid electrolyte and local reaction environment. The structural transformations of the Ag electrocatalyst are monitored with non-negative matrix factorization, linear combination analysis, the Pearson correlation coefficient matrix, and refinements in both real and reciprocal space. Upon application of an oxidative potential in an Ar-saturated aqueous 0.1 M KHCO 3 /K 2 CO 3 electrolyte, the face-centered cubic (f.c.c.) Ag gradually transforms first to a trigonal Ag 2 CO 3 phase, followed by the formation of a monoclinic Ag 2 CO 3 phase. A reducing potential immediately reverts the structure to the Ag (f.c.c.) phase. Following the electrochemical-reaction-induced phase transitions is of fundamental interest and necessary for understanding and improving the stability of electrocatalysts, and the operando cell proves a versatile setup for probing this. In addition, it is demonstrated that, when studying electrochemical reactions, a high energy or short exposure time is needed to circumvent beam-induced effects.

Frank, Sara (ORCID:0000000163218363)↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗

The effect of blood viscosity on shear‐induced hemolysis using a magnetically levitated shearing device

Abstract Introduction Blood contacting medical devices, including rotary blood pumps, can cause shear‐induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell‐scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). Methods We empirically investigated hemolysis in a magnetically levitated axial Couette flow device typical of a rotary VAD. The device is able to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Using this device, we explored the effects of both hematocrit and plasma viscosity on shear‐induced hemolysis to characterize blood damage based on the viscosity‐independent shear rate, rather than on shear stress. Results Over a shear rate range of 20 000 – 80 000 1/s, the Index of Hemolysis (IH) was found to be dependent upon and well‐predicted by the shear rate alone. IH was independent of hematocrit, bulk viscosity, or the suspension media viscosity and less correlated to shear stress (MSE = 0.46–0.75) than to shear rate (MSE = 0.06–0.09). Conclusion This study recommends that future investigations of shear‐induced blood damage report findings with respect to the viscosity‐neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.

Krisher, James A.↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗