Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The 6 GeV TMD Program at Jefferson Lab

The study of the transverse momentum dependent parton distributions (TMDs) of the nucleon in semi-inclusive deep-inelastic scattering (SIDIS) has emerged as one of the major physics motivations driving the experimental program using the upgraded 11 GeV electron beam at Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF). The accelerator construction phase of the CEBAF upgrade is essentially complete and commissioning of the accelerator has begun as of April, 2014. As the new era of CEBAF operations begins, it is appropriate to review the body of published and forthcoming results on TMDs from the 6 GeV era of CEBAF operations, discuss what has been learned, and discuss the key challenges and opportunities for the 11 GeV SIDIS program of CEBAF.

43 PARTICLE ACCELERATORS↗

A spectrometer for ultrashort gamma-ray pulses with photon energies greater than 10 MeV

Herein we present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction.

47 OTHER INSTRUMENTATION↗

SOLAR WIND DENSITY TURBULENCE AND SOLAR FLARE ELECTRON TRANSPORT FROM THE SUN TO THE EARTH

Solar flare accelerated electron beams propagating away from the Sun can interact with the turbulent interplanetary media, producing plasma waves and Type III radio emission. These electron beams are detected near the Earth with a double power-law energy spectrum. We simulate electron beam propagation from the Sun to the Earth in the weak turbulent regime taking into account the self-consistent generation of plasma waves and subsequent wave interaction with density fluctuations from low-frequency MHD turbulence. The rate at which plasma waves are induced by an unstable electron beam is reduced by background density fluctuations, most acutely when fluctuations have large amplitudes or small wavelengths. This suppression of plasma waves alters the wave distribution which changes the electron beam transport. Assuming a 5/3 Kolmogorov-type power-density spectrum of fluctuations often observed near the Earth, we investigate the corresponding energy spectrum of the electron beam after it has propagated 1 AU. We find a direct correlation between the spectrum of the double power-law below the break energy and the turbulent intensity of the background plasma. For an initial spectral index of 3.5, we find a range of spectra below the break energy between 1.6 and 2.1, with higher levels of turbulence corresponding to higher spectral indices.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a direct-sampling RF receiver for precision beam charge measurements in the MOLLER experiment

Here, we have developed and tested a direct-sampling RF receiver capable of measuring the amplitude of a 1497 MHz sinusoidal beam signal in 0.5 ms integration windows with a relative uncertainty of better than 10 parts per million. The receiver is intended for measuring signals from beam current monitoring cavities on the beamline of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. The beam signal strength, frequency, and integration window fulfill the thus far unmet requirements of the upcoming MOLLER experiment to measure the beam charge for different helicity states.

47 OTHER INSTRUMENTATION↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗

Multislice simulation of transmission electron microscopy imaging of helium bubbles in Fe

Formation of nanoscale helium (He) bubbles in reduced activation ferritic/martensitic steels may lead to degradation of mechanical properties of materials. Transmission electron microscopy (TEM) has been commonly used to image the Fresnel contrast of He bubbles using a defocus of 0.5 µm ~ 1 µm. This paper presents our study of multislice simulation of the size correlation between imaged Fresnel rings and the actual He bubbles. It was found that for bubbles equal to or larger than 3 nm in diameter, the imaged bubble size, represented by its inner diameter of the first dark Fresnel ring (Din) in under-focused imaging conditions, increases with increasing electron-beam incoherency, but decreases with increasing defocus. The electron-beam accelerating voltage, bubble size, bubble position, and TEM sample thickness were found to have no significant influence on the deviation of Din from the actual bubble size (D0). For bubbles equal to or smaller than 2 nm, however, Din/Do increases dramatically with increasing defocus when it is above a threshold defocus. It was also suggested by this study that He bubbles can be differentiated from argon (Ar) bubbles by contrast differences.

Yao, Bo↗

Detecting anomalous SRF cavity behavior with unsupervised learning

We present an unsupervised learning framework for detecting anomalous superconducting radio-frequency (SRF) cavity behavior at the Continuous Electron Beam Accelerator Facility (CEBAF), emphasizing its initial performance and effectiveness. Key to the system’s success was the development of data acquisition systems (DAQs) that capture fast-sampled, information-rich signals, essential for detecting transient effects. The approach involves creating daily cavity-specific models using principal component analysis to handle variations in rf signal behavior and mitigate performance degradation from data drift. This unsupervised method eliminates the need for expensive labeling by continuously updating models with recent data. Deployed and operational for 3 months before a scheduled shutdown, the system successfully identified several issues with DAQ signals, confirming its effectiveness. Despite access to only a fraction of CEBAF’s SRF cavity signals, the framework efficiently detected several instances requiring intervention, demonstrating a significant improvement over traditional, labor-intensive methods of manual plot inspection. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Electroexcitation of nucleon resonances of the [ 70 , 1 - ] multiplet in a light-front relativistic quark model

We utilize the light-front relativistic quark model to predict the 3q core contribution to the electroexcitation of nucleon resonances of the [70,1 – ] multiplet on the proton and neutron at Q 2 < 5 GeV 2 . The investigation is motivated by new experimental data from continuous electron beam accelerator facility large acceptance spectrometer on meson electroproduction for a wide range of the hadronic invariant mass including the full third nucleon resonance region up to √s = 1.8 GeV. For the states N(1520)3/2 – , N(1535)1/2 – , and N(1675)5/2 – , experimental results on the electroexcitation amplitudes on the proton are available for a wide range of Q 2 . Lastly, this allowed us also to quantify the expected meson-baryon contributions to these amplitudes as a function of Q 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty Aware Deep Learning for Fault Prediction Using Multivariate Time Series Signals

The superconducting radio-frequency cavities are a crucial component of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. When a cavity faults, beam delivery to experimental end users is disrupted. Prediction of cavity faults prior to onset is essential to reduce operation and maintenance costs. In this work, a parallel long short-term memory (LSTM)-convolution neural network (CNN)-based deep learning (DL) model is proposed to predict impending faults using pre-fault signals. Further, we introduce an uncertainty quantification approach using Monte Carlo dropout with the LSTM-CNN model to ascertain confidence in the prediction. The model was tested using multivariate time series signals from stable cavity operations and before faults. Initial results show that on the test dataset, the model can identify impending faults before their onset with an average 10-fold cross validation accuracy of 97.39% and a standard deviation of 0.12% using a 100-ms time window. It is also observed that the model performs better as the prediction time moves closer to the fault onset. For additional context, we compare the performance of the model with three machine-learning-based (ML) fault prediction models. Our proposed parallel LSTM-CNN-based DL method shows better performance than the ML-based methods.

Rahman, Md Monibor↗

WE-E-18A-05: Bremsstrahlung of Laser-Plasma Interaction at KeV Temperature: Forward Dose and Attenuation Factors

Purpose: To obtain an analytical empirical formula for the photon dose source term in forward direction from bremsstrahlung generated from laser-plasma accelerated electron beams in aluminum solid targets, with electron-plasma temperatures in the 10–100 keV energy range, and to calculate transmission factors for iron, aluminum, methacrylate, lead and concrete and air, materials most commonly found in vacuum chamber labs. Methods: Bremsstrahlung fluence is calculated from the convolution of thin-target bremsstrahlung spectrum for monoenergetic electrons and the relativistic Maxwell-Juettner energy distribution for the electron-plasma. Unattenuatted dose in tissue is calculated by integrating the photon spectrum with the mass-energy absorption coefficient. For the attenuated dose, energy dependent absorption coefficient, build-up factors and finite shielding correction factors were also taken into account. For the source term we use a modified formula from Hayashi et al., and we fitted the proportionality constant from experiments with the aid of the previously calculated transmission factors. Results: The forward dose has a quadratic dependence on electron-plasma temperature: 1 joule of effective laser energy transferred to the electrons at 1 m in vacuum yields 0,72 Sv per MeV squared of electron-plasma temperature. Air strongly filters the softer part of the photon spectrum and reduce the dose to one tenth in the first centimeter. Exponential higher energy tail of maxwellian spectrum contributes mainly to the transmitted dose. Conclusion: A simple formula for forward photon dose from keV range temperature plasma is obtained, similar to those found in kilovoltage x-rays but with higher dose per dissipated electron energy, due to thin target and absence of filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-E-18A-06: To Remove Or Not to Remove: Comfort Pads From Beneath Neonates for Radiography

Purpose: To obtain an analytical empirical formula for the photon dose source term in forward direction from bremsstrahlung generated from laser-plasma accelerated electron beams in aluminum solid targets, with electron-plasma temperatures in the 10–100 keV energy range, and to calculate transmission factors for iron, aluminum, methacrylate, lead and concrete and air, materials most commonly found in vacuum chamber labs. Methods: Bremsstrahlung fluence is calculated from the convolution of thin-target bremsstrahlung spectrum for monoenergetic electrons and the relativistic Maxwell-Juettner energy distribution for the electron-plasma. Unattenuatted dose in tissue is calculated by integrating the photon spectrum with the mass-energy absorption coefficient. For the attenuated dose, energy dependent absorption coefficient, build-up factors and finite shielding correction factors were also taken into account. For the source term we use a modified formula from Hayashi et al., and we fitted the proportionality constant from experiments with the aid of the previously calculated transmission factors. Results: The forward dose has a quadratic dependence on electron-plasma temperature: 1 joule of effective laser energy transferred to the electrons at 1 m in vacuum yields 0,72 Sv per MeV squared of electron-plasma temperature. Air strongly filters the softer part of the photon spectrum and reduce the dose to one tenth in the first centimeter. Exponential higher energy tail of maxwellian spectrum contributes mainly to the transmitted dose. Conclusion: A simple formula for forward photon dose from keV range temperature plasma is obtained, similar to those found in kilovoltage x-rays but with higher dose per dissipated electron energy, due to thin target and absence of filtration.

07 ISOTOPE AND RADIATION SOURCES↗

Momentum Dependence of Near-Threshold J/ψ Photoproduction off Nuclei

The photoproduction of J/ψ mesons off nuclei at the energies of 8 and 11 GeV, which are close to the threshold for their production on a free nucleon, is considered on the basis of the first-collisionmodel relying on the nuclear spectral function and including incoherent processes of charmonium production in photon–nucleon collisions. The model takes into account the absorption of final J/ψ mesons, the binding of target nucleons, and their Fermi motion, as well as the effect of the scalar J/ψ–nucleus potential (or the inmedium shift of the J/ψ-meson mass) on these processes. Under various assumptions on the magnitude of this shift, the momentum dependences of various observables, such as the relative transparency of carbon and gold nuclei and the J/ψ-meson yields, are calculated for meson production on these nuclei. The observables in question include the relative transparencies of these nuclei to J/ψ mesons and the absolute and relativemeson yields from them. It is shown that, at the energy of 11 GeV, which is above the threshold, the first observable is virtually independent of the in-medium change in the J/ψ-meson mass. At the same time, it is moderately sensitive to this change at the subthreshold energy of 8 GeV. On the other hand, it is shown that, at these photon energies, the absolute and relative values of the differential cross sections, especially for the the heavy nucleus of {sup 197} Au, in the momentum range of 4–6 GeV/с are highly sensitive to the in-medium change in the J/ψ-meson mass. Therefore, the present calculations can be used to determine the unknown shift of the J/ψ-meson mass in nuclei by means of comparing their results with data expected from experiments in Hall C at the Continuous Electron Beam Accelerator Facility (CEBAF, USA) upgraded to the energy of 12 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing charged lepton flavor violation with a positron beam at CEBAF (JLAB)

The addition of a high intensity 11 GeV polarized positron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) at JLAB would allow for a search of Charged Lepton Flavor Violation (CLFV) via the process $e^+N \rightarrow \mu^+ X$. The proposed Solenoidal Large Intensity Detector (SoLID) spectrometer, in the configuration with muon chambers, would be ideal for such CLFV searches. Various new physics scenarios, including the phenomenologically convenient Leptoquark (LQ) framework, predict CLFV rates that are within reach of current or planned experiments. A positron beam with instantaneous luminosity, ${\cal L}\sim 10^{38}$ cm$^{-2}$s$^{-1}$, could improve on existing HERA limits by two or three orders of magnitude. The availability of positron beam polarization would also allow for distentangling CLFV effects mediated by left-handed vs. right-handed LQs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strong interaction physics at the luminosity frontier with 22 GeV electrons at Jefferson Lab

Here, the purpose of this document is to outline the developing scientific case for pursuing an energy upgrade to 22 GeV of the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (TJNAF, or JLab). This document was developed with input from a series of workshops held in the period between March 2022 and April 2023 that were organized by the JLab user community and staff with guidance from JLab management (see Sec. 10). The scientific case for the 22 GeV energy upgrade leverages existing or already planned Hall equipment and world-wide uniqueness of CEBAF high-luminosity operations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel↗

Meson Spectroscopy At Jlab At 12 Gev

The 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab will enable a new generation of experiments in hadronic nuclear physics, seeking to address fundamental questions in our understanding of QCD. The existence of exotic states, suggested by both quark models and lattice calculations, would allow gluonic degrees of freedom to be explored, and may help explain the role played by gluons in the QCD interaction. This article will review the meson spectroscopy program being planned at the lab following the 12 GeV upgrade, utilising real and quasi-real photon beams in two of the lab's four experimental halls, whose distinct capabilities will enable an extensive set of spectroscopy experiments to be performed at the same facility.

Fegan, Stuart↗

Jefferson Lab at 12 GeV: The Science Program

Jefferson Lab’s upgrade of its Continuous Electron Beam Accelerator Facility (CEBAF) has recently been completed. The project involved an upgrade of the accelerator to achieve a maximum beam energy of 12 GeV and the construction of a fourth end station, Experimental Hall D, as well as new detector equipment for two of the three existing halls (A, B, and C). A broad experimental program has been developed to map the nucleon’s intrinsic quark distributions in transverse space and in longitudinal momentum through measurements of deeply exclusive and semi-inclusive processes, and to probe color confinement by studying the spectrum of hadrons with active gluon degrees of freedom in the wave function. Other programs include the forward parton distribution function at large quark momentum fraction χ, the quark and gluon polarized distribution functions, measurements of electromagnetic form factors of the nucleon ground state and of nucleon resonance transitions at short distances, and the exploration of physics beyond the Standard Model in high-precision parity-violating processes and in the search for signals of dark matter. The higher beam energy is also suitable for exploration of quark hadronization properties using the nucleus as a laboratory. This review highlights major areas of hadron and nuclear science that will be the focus of the first 5 years of operation.

3D imaging↗