Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eddy current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

OTVE turbopump condition monitoring, task E.5

Recent work has been carried out on development of isotope wear analysis and optical and eddy current technologies to provide bearing wear measurements and real time monitoring of shaft speed, shaft axial displacement and shaft orbit of the Orbit Transfer Vehicle hydrostatic bearing tester. Results show shaft axial displacement can be optically measured (at the same time as shaft orbital motion and speed) to within 0.3 mils by two fiberoptic deflectometers. Evaluation of eddy current probes showed that, in addition to measuring shaft orbital motion, they can be used to measure shaft speed without having to machine grooves on the shaft surface as is the usual practice for turbomachinery. The interim results of this condition monitoring effort are presented.

Coleman, Paul T.↗

Noncontact Measurement Of Sizes And Eccentricities Of Holes

Semiautomatic eddy-current-probe apparatus makes noncontact measurements of nominally round holes in electrically conductive specimens and processes measurement data into diameters and eccentricities of holes. Includes x-y translation platform, which holds specimen and moves it horizontally. Probe mounted on probe scanner, positioning probe along vertical (z) direction and rotates probe about vertical axis at preset low speed. Eddy-current sensing coil mounted in side of probe near tip. As probe rotates, impedance analyzer measures electrical impedance (Z) of coil as function of instantaneous rotation angle. Translation and rotation mechanisms and impedance analyzer controlled by computer, which also processes impedance-measurement data.

Chern, Engmin J.↗

Composite pressure cell for pulsed magnets

We report that extreme pressures and high magnetic fields can affect materials in profound and fascinating ways. However, large pressures and fields are often mutually incompatible; the rapidly changing fields provided by pulsed magnets induce eddy currents in the metallic components used in conventional pressure cells, causing serious heating, forces, and vibration. Here, we report a diamond-anvil-cell made mainly out of insulating composites that minimizes inductive heating while retaining sufficient strength to apply pressures of up to 8 GPa. Any residual metallic component is made of low-conductivity metals and patterned to reduce eddy currents. The simple design enables rapid sample or pressure changes, desired by pulsed-magnetic-field-facility users. The pressure cell has been used in pulsed magnetic fields of up to 65 T with no noticeable heating at cryogenic temperatures. Several measurement techniques are possible inside the cell at temperatures as low as 500 mK.

47 OTHER INSTRUMENTATION↗

Intensification of Hurricane Sally (2020) over the Mississippi River Plume

Abstract Tropical Cyclone (TC) Sally formed on 11 September 2020, traveled through the Gulf of Mexico (GMX), and intensified rapidly before making landfall on the Alabama coast as a devastating category-2 TC with extensive coastal and inland flooding. In this study, using a combination of observations and idealized numerical model experiments, we demonstrate that the Mississippi River plume played a key role in the intensification of Sally near the northern Gulf Coast. As the storm intensified and its translation slowed before landfall, sea surface cooling was reduced along its track, coincident with a pronounced increase in SSS. Further analysis reveals that TC Sally encountered a warm Loop Current eddy in the northern GMX close to the Mississippi River plume. Besides deepening the thermocline, the eddy advected low-salinity Mississippi River plume water into the storm’s path. This resulted in the development of strong upper-ocean salinity stratification, with a shallow layer of freshwater lying above a deep, warm “barrier layer.” Consequently, TC-induced mixing and the associated sea surface cooling were reduced, aiding Sally’s intensification. These results suggest that the Mississippi River plume and freshwater advection by the Loop Current eddies can play an important role in TC intensification near the U.S. Gulf Coast.

54 ENVIRONMENTAL SCIENCES↗

Methods Developed by the Tools for Engine Diagnostics Task to Monitor and Predict Rotor Damage in Real Time

Tools for Engine Diagnostics is a major task in the Propulsion System Health Management area of the Single Aircraft Accident Prevention project under NASA s Aviation Safety Program. The major goal of the Aviation Safety Program is to reduce fatal aircraft accidents by 80 percent within 10 years and by 90 percent within 25 years. The goal of the Propulsion System Health Management area is to eliminate propulsion system malfunctions as a primary or contributing factor to the cause of aircraft accidents. The purpose of Tools for Engine Diagnostics, a 2-yr-old task, is to establish and improve tools for engine diagnostics and prognostics that measure the deformation and damage of rotating engine components at the ground level and that perform intermittent or continuous monitoring on the engine wing. In this work, nondestructive-evaluation- (NDE-) based technology is combined with model-dependent disk spin experimental simulation systems, like finite element modeling (FEM) and modal norms, to monitor and predict rotor damage in real time. Fracture mechanics time-dependent fatigue crack growth and damage-mechanics-based life estimation are being developed, and their potential use investigated. In addition, wireless eddy current and advanced acoustics are being developed for on-wing and just-in-time NDE engine inspection to provide deeper access and higher sensitivity to extend on-wing capabilities and improve inspection readiness. In the long run, these methods could establish a base for prognostic sensing while an engine is running, without any overt actions, like inspections. This damage-detection strategy includes experimentally acquired vibration-, eddy-current- and capacitance-based displacement measurements and analytically computed FEM-, modal norms-, and conventional rotordynamics-based models of well-defined damages and critical mass imbalances in rotating disks and rotors.

Baaklini, George Y.↗

The trade-off characteristics of acoustic and pressure sensors for the NASP

Results of a trade study for the development of pressure and acoustic sensors for use on the National Aerospace Plane (NASP) are summarized. Pressure sensors are needed to operate to 100 psia; acoustic sensors are needed that can give meaningful information about a 200 dB sound pressure level (SPL) environment. Both sensors will have to operate from a high temperature of 2000 F down to absolute zero. The main conclusions of the study are the following: (1) Diaphragm materials limit minimum size and maximum frequency response attainable. (2) No transduction is available to meet all the NASP requirements with existing technology. (3) Capacitive sensors are large relative to the requirement, have limited resolution and frequency response due to noise, and cable length is limited to approximately 20 feet. (4) Eddy current sensors are large relative to the requirement and have limited cable lengths. (5) Fiber optic sensors provide the possibility for a small sensor, even though present developments do not exhibit that characteristic. The need to use sapphire at high temperature complicates the design. Present high temperature research sensors suffer from poor resolution. A significant development effort will be required to realize the potential of fiber optics. (6) Short-term development seems to favor eddy current techniques with the penalty of larger size and reduced dynamic range for acoustic sensors. (7) Long-term development may favor fiber optics with the penalties of cost, schedule, and uncertainty.

Winkler, Martin↗

Dynamic Characterization of Galfenol (Fe81.6Ga18.4)

Galfenol has the potential to transform the smart materials industry by allowing for the development of multifunctional, load-bearing devices. One of the primary technical challenges faced by this development is the very limited experimental data on Galfenol's frequency-dependent response to dynamic stress, which is critically important for the design of such devices. This report details a novel and precise characterization of the constitutive behavior of polycrystalline Galfenol (Fe81.6Ga18.4) under quasi-static (1 Hz) and dynamic (4 to 1000 Hz) stress loadings. Mechanical loads are applied using a high-frequency load frame. Quasi-static minor and major hysteresis loop measurements of magnetic flux density and strain are presented for constant electromagnet currents (0 to 1.1 A) and constant magnetic fields 0 to 14 kA/m (0 to 180 Oe). The dynamic stress amplitude for minor and major loops is 2.88 and 31.4 MPa (418 and 4550 psi), respectively. Quasi-static material properties closely match published values for similar Galfenol materials. Quasi-static actuation responses are also measured and compared to quasi-static sensing responses; the high degree of reversibility seen in the comparison is consistent with published measurements and modeling results. Dynamic major and minor loops are measured for dynamic stresses up to 31 MPa (4496 psi) and 1 kHz, and the bias condition resulting in maximum, quasi-static sensitivity. Eddy current effects are quantified by considering solid and laminated Galfenol rods. Three key sources of error in the dynamic measurements are accounted for: (1) electromagnetic noise in strain signals due to Galfenol's magnetic response, (2) error in load signals due to the inertial force of fixturing, and (3) phase misalignment between signals due to conditioning electronics. For dynamic characterization, strain error is kept below 1.2 percent of full scale by wiring two collocated gauges in series (noise cancellation) and through leadwire weaving. Inertial force error is kept below 0.41 percent by measuring the dynamic force in the specimen using a nearly collocated piezoelectric load washer. The phase response of all conditioning electronics is explicitly measured and corrected for. In general, as frequency is increased, the sensing response becomes more linear because of an increase in eddy currents. As frequency increases above approximately 100 Hz, the elbow in the strain-versus-stress response disappears as the active (soft) regime stiffens toward the passive (hard) regime. Under constant-field conditions, the loss factors of the solid rod peak between 200 and 600 Hz, rather than exhibiting a monotonic increase. Compared to the solid rod, the laminated rod exhibits much slower increases in hysteresis with frequency, and its quasi-static behavior extends to higher frequencies. The elastic modulus of the laminated rod decreases between 100 and 300 Hz; this trend is currently unexplained.

Dynamic sensing↗

Ultralow Friction in a Superconducting Magnetic Bearing

Passive levitation by superconducting magnetic bearings can be utilized in flywheels for energy storage. Basic design criteria of such a bearing are high levitation force, sufficient vertical and horizontal stability and low friction. A test facility was built for the measurement and evaluation of friction in a superconducting magnetic bearing as a function of operating temperature and pressure in the vacuum vessel. The bearing consists of a commercial disk shaped magnet levitated above single grain, melt-textured YBCO high-temperature superconductor material. The superconductor was conduction cooled by an integrated AEG tactical cryocooler. The temperature could be varied from 50 K to 80 K. The pressure in the vacuum chamber was varied from 1 bar to 10(exp -5) mbar. At the lowest pressure setting, the drag torque shows a linear frequency dependence over the entire range investigated (0 less than f less than 40 Hz). Magnetic friction, the frequency independent contribution, is very low. The frequency dependent drag torque is generated by molecular friction from molecule-surface collisions and by eddy currents. Given the specific geometry of the set-up and gas pressure, the molecular drag torque can be estimated. At a speed of 40 Hz, the coefficient of friction (drag-to-lift ratio) was measured to be mu = 1.6 x 10(exp -7) at 10(exp -5) mbar and T = 60 K. This is equivalent to a drag torque of 7.6 x 10(exp -10) Nm. Magnetic friction causes approx. 1% of the total losses. Molecular friction accounts for about 13% of the frequency dependent drag torque, the remaining 87% being due to eddy currents and losses from rotor unbalance. The specific energy loss is only 0.3% per hour.

Bornemann, Hans J.↗

Formation of the lunar crust - An electrical source of heating

A model for formation of the lunar crust based on heating by electrical induction is explored, while adherence is maintained to certain constraints associated with existing models of the solar system. The heating mechanism is based on eddy current induction from disordered magnetic fields swept outwards by an intense (T Tauri-like) plasma flow from the sun. The electrical theory is an alternative to intense short-period accretion as a source of heat for the evolution of lunar maria and highlands, provided that long-lived radioactives are not swept to the surface from too large a melt volume during the initial thermal episode. This formation of the lunar highlands does not intrinsically require rapid accretion, nor on this basis is the time of formation of the planets generally restricted to a very short time. The threshold temperature for eddy current heating is attained by either a solar nebula at 300-400 C during formation of the moon or a very low energy long-period accumulation of the moon, both leading to melting in ten to the fifth to ten to the seventh power years.

Sonett, C. P.↗

Influence of scan pattern and geometry on the microstructure and soft-magnetic performance of additively manufactured Fe-Si

The influence of geometry and scan pattern on the microstructure evolution and magnetic performance of additively manufactured Fe-3Si components was investigated. To reduce eddy current losses, novel geometries were designed and built and the microstructure and properties of these samples were characterized. The laser scan pattern was shown to strongly influence both the as-built grain structure and strength of the crystallographic texture, resulting in measurable changes in the as-built magnetic performance. In thin wall samples, heat treatment resulted in an increase in the maximum relative magnetic permeability and decrease in power losses in most samples, consistent with grain growth. However, decreases in the spacing between thin walls to increase the stacking factor of the cross-section was shown to result in unwanted electrical shorting between walls and an increase in eddy current losses. Compared to simple parallel plate construction and a mesh structure, a novel cross-section design based on the Hilbert space filling curve was found to produce the lowest power losses. The mechanisms behind these results were explored using a combination of heat conduction and electromagnetic simulations, providing a route for future component and process optimization.

36 MATERIALS SCIENCE↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

The application of macroscopic flakes for Fe-6.5%Si bulk magnetics with superior magnetic properties

Silicon steel is the most popular crystalline soft magnetic material for motor and transformer applications. The material must be in thin thickness to reduce the eddy current loss. Conventional thin steel sheet manufacturing process starts with cast slab, followed by a series of hot/cold roll process. For transformer, thin sheet is wrapped to form the core; for motor, the sheet is stamped, coated, heat treated, and stacked to form stator/rotor. This process requires the steel to possess sufficient ductility. For Si steel, increasing Si content will improve its electrical and magnetic properties, but it will also lead to embrittlement with 3.5% Si as the limit for the conventional manufacturing processes. Despite poor mechanical properties, high Si steel, especially the one with 6.5% Si, is gaining more attention due to its lower iron loss, higher permeability, and near zero magnetostriction. To address the brittleness problem of the 6.5% Si steel, we developed a novel process, using rapid solidification to prepare thin flakes with high ductility, then using hot press to consolidate the flakes into near net shape bulk sample. The obtained Fe-6.5%Si sample with 0.2 mm thickness exhibits an iron loss of 7.2 W/kg at 400Hz and magnetic flux density of 1 Tesla, and a maximum permeability of 28,400. In addition, various coating materials and processes were investigated as inter-flake insulators for their effect on reducing the eddy current losses for thicker configuration.

Fe-6.5%Si Steel↗

The Damper Spring Unit of the Sentinel 1 Solar Array

The Damper Spring Unit (DSU, see Figure 1) has been designed to provide the damping required to control the deployment speed of the spring driven solar array deployment in an ARA Mk3 or FRED based Solar Array in situations where the standard application of a damper at the root-hinge is not feasible. The unit consists of four major parts: a main bracket, an eddy current damper, a spring unit, an actuation pulley which is coupled via Kevlar cables to a synchro-pulley of a hinge. The damper slows down the deployment speed and prevents deployment shocks at deployment completion. The spring unit includes 4 springs which overcome the resistances of the damper and the specific DSU control cable loop. This means it can be added to any spring driven deployment system without major modifications of that system. Engineering models of the Sentinel 1 solar array wing have been built to identify the deployment behavior, and to help to determine the optimal pulley ratios of the solar array and to finalize the DSU design. During the functional tests, the behavior proved to be very sensitive for the alignment of the DSU. This was therefore monitored carefully during the qualification program, especially prior to the TV cold testing. During TV "Cold" testing the measured retarding torque exceeded the max. required value: 284 N-mm versus the required 247 N-mm. Although this requirement was not met, the torque balance analysis shows that the 284 N-mm can be accepted, because the spring unit can provide 1.5 times more torque than required. Some functional tests of the DSU have been performed without the eddy current damper attached. It provided input data for the ADAMS solar array wing model. Simulation of the Sentinel-1 deployment (including DSU) in ADAMS allowed the actual wing deployment tests to be limited in both complexity and number of tests. The DSU for the Sentinel-1 solar array was successfully qualified and the flight models are in production.

Doejaaren, Frans↗

TU-H-206-07: Assessment of Geometric Distortion in EPI with a SPAMM Tagged Acquisition

Purpose: Echo planar imaging (EPI) is known to exhibit gross geometric distortion caused by multiple factors, including B0 inhomgeneity and transient eddy currents. However, diffusion weighted (DW) EPI has become indispensable for diagnosis and therapy assessment. We propose a methodology for quantifying distortion in EPI sequences that does not require the use of dedicated spatial accuracy phantoms, enabling flexibility in phantom design for QA of distortion effects in EPI protocols. Methods: The proposed methodology utilizes a saturation technique known as Spatial Modulation of Magnetization (SPAMM) that tags the imaging subject with saturated grid lines. Originally intended for tracking cardiac motion, these grids are applied to assess differences between diffusion weighting directions and b-values, or against a more geometrically robust sequence such as fast spin echo (FSE). The saturation preparation sequence consists of binomially weighted (e.g. 1-3-3-1) pulses interleaved with gradient blips along the frequency encode direction, followed by the same sequence with gradient blips in the phase encode direction. Three phantoms were assessed with these sequences: a spherical head-sized phantom, a large shimming phantom, and a modified PET ACR phantom that included compartments of water, air, oil, and Teflon. Each phantom was acquired with three sequences using parameters from a clinically appropriate protocol (22 cm head or 46 cm abdomen): a conventional DW-EPI sequence (3 DW directions), and both the DW-EPI and FSE sequences with tagging. Differences in grid locations were visualized with minimum intensity projection between images, and measured using intersecting locations on the grids. Results: Grid lines were clearly visualized on tagged images and enabled quantification of distortions. Maximum eddy current induced errors of 10.8 to 14.8 mm were observed in areas away from isocenter with DW gradients applied in various directions. Conclusion: SPAMM tagging provides a promising mechanism for assessing spatial distribution of distortion in EPI sequences.

60 APPLIED LIFE SCIENCES↗

NDT System for Metal Components in Concrete Structures (Final Report)

Steel reinforcements embedded within concrete can corrode and crack, leading to weakening of the structures, and existing NDT (non-destructive testing) techniques do not provide the full picture. Condition assessment is critical in evaluating these structures in order to ensure safe, long-term operation of the nuclear power plants. Improved NDT techniques are needed as the nation’s generating stations age and require action based on increasingly critical inspection data. The power industry uses eddy current test (ECT) during in-service inspections to detect and monitor defects such as cracks and corrosion in metals, particularly metal pipes. However, the detection of defects in the reinforcing steel embedded in concrete is far more challenging for numerous reasons. Primary among them is the concrete layer’s thickness, which prevents the ability to have a close proximity between sensor and metallic sample. One solution to this problem is to create a higher sensitivity technique which can inspect at depth, with good spatial resolution and excellent directional sensitivity, to isolate the metal buried deep in the concrete and characterize defects in the metal. The goal of the phase II research program was to study and develop a new reinforced concrete NDT technology based on anisotropic magnetoresistive (AMR) sensors designed specifically for ECT of steel reinforcements in concrete. The first technical objective was to demonstrate the capability of inspecting steel reinforcement structures, including metal rebar and tensioning cable at or below 6” of depth embedded in concrete. Another objective was to be able to confidently identify multiple layers of reinforcements at varying depths. In addition, the technique needed to be able to provide condition assessment of the metal, providing data on the structure and positioning of the steel members, material loss, and detection of the presence of breaks. An important part of the research and development was aimed at achieving superior performance compared to existing technology. The ability to detect corrosion breaks in unbonded multi-wire and multi-strand tendons was another important objective. The final objective that led to a successful program was to build a complete prototype portable scanning system capable of demonstrating the probe performance in the field. All of these objectives were met, which provided data for the system development work going forward. RMD worked with the engineering firm Simpson Gumpertz & Heger to develop a detailed problem definition for concrete structures and the necessary sensor specifications. In addition, we developed finite element simulation models for the eddy current based NDT system through the analysis of the electromagnetic (EM) properties of sample materials and the orientation of the transmitter, sensor array (receivers), metal, and intervening materials like concrete and air. Based on the modeling and specifications, we designed and fabricated prototype sensor modules. We then acquired and fabricated test samples to characterize and optimize the sensors. Finally, we built a complete prototype for testing on actual concrete structures. This new NDT technology has high promise for greatly improving capabilities in the inspection of steel reinforcements within concrete structures, such as rebar, liners, anchors, and prestressing cables. This method could be valuable in the maintenance of nuclear power plants, and many other structures critical to our nation’s infrastructure.

42 ENGINEERING↗

Fourier-based magnetic induction tomography for mapping resistivity

Magnetic induction tomography is used as an experimental tool for mapping the passive electromagnetic properties of conductors, with the potential for imaging biological tissues. Our numerical approach to solving the inverse problem is to obtain a Fourier expansion of the resistivity and the stream functions of the magnetic fields and eddy current density. Thus, we are able to solve the inverse problem of determining the resistivity from the applied and measured magnetic fields for a two-dimensional conducting plane. When we add noise to the measured magnetic field, we find the fidelity of the measured to the true resistivity is quite robust for increasing levels of noise and increasing distances of the applied and measured field coils from the conducting plane, when properly filtered. We conclude that Fourier methods provide a reliable alternative for solving the inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetically Induced Current Piston for Generating Extreme-ultraviolet Fronts in the Solar Corona

Single-pulse, globally propagating coronal fronts, called Extreme-ultraviolet (EUV) waves, were first confirmed in 1995 by the Extreme-ultraviolet Imaging Telescope and every observed EUV wave since has been associated with a coronal mass ejection (CME). The physical mechanism underlying these waves has been debated for two decades with wave or pseudo-wave theories being advocated. We introduce a hybrid model where EUV waves are compressional fronts driven by a reverse electric current layer induced by the time-dependent CME core current. The reverse current layer flows in a direction opposite to the CME core current and is an eddy current layer necessary to maintain magnetic flux conservation above the layer. Repelled by the core current, the reverse current layer accelerates upward so it acts as a piston that drives a compressional perturbation in the coronal regions above. Given a sufficiently fast piston speed, the compressional perturbation becomes a shock that separates from the piston when the piston slows down. Since the model relates the motion of the EUV front to CME properties, the model provides a bound for the core current of an erupting CME. The model is supported and motivated by detailed results from both laboratory experiments and ideal 3D magnetohydrodynamic simulations. Overlaps and differences with other models and spacecraft observations are reported on.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma current position measurements in the Korea Superconducting Tokamak Advanced Research device

The plasma current position is measured based on the current multipole moment method in the Korea Superconducting Tokamak Advanced Research (KSTAR) device [G. S. Lee et al., Nucl. Fusion 41, 1515 (2001)]. Since a limited number of magnetic probes and flux loops were installed for the first campaign, an iteration method is used to interpolate the magnetic field in the area absent of probes. A numerical technique is developed which automatically compensates for the linear drift of the integrator. The measured plasma position is cross checked with the charge coupled device images. In KSTAR, the plasma current is displaced toward the lower outboard direction during the current initiation phase. This displacement is expected due to eddy currents but the exact amount and direction needs more study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗