NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VitriEdge: Repairable & Durable Vitrimer Coatings for Wind Turbine Blade Leading Edges

The primary goal of this Level 1b incubator project was to explore the use of vitrimer coatings for repair of leading-edge erosion on end-of-life wind turbine blade surfaces, beyond coating strength of adhesion which has previously been demonstrated in the Level 1a project. Uniform vitrimer coatings (thickness: 400 µm) were applied to two end-of-life wind turbine blades for flexural, fatigue, and laminate tensile testing where the addition of the coating did not produce any statistical variation in tensile properties with minor drops in flexural strength for some laminate formulations. However, a <2% variation in storage modulus was measured for laminate structures (i.e., blade samples with vitrimer coatings) across 100,000 flexural cycles and upon laminate tensile failure, the vitrimer coatings displayed no visible signs of delamination. In addition, three methods to heal vitrimer coating damage was displayed: oven heating, addition of hot water, and a forced convection heat gun. All three heating and healing mechanisms demonstrated significant healing with scratch depths decreasing between 79-91% at healing times ranging between 1-min and 10-minutes. Finally, a water jet machine was used to simulate rain erosion for both the blade surfaces and vitrimer-coated blade surfaces where the diameter and depth of the damage was recorded as a function of exposure time, water pressure, height of exposure, and angle of exposure. Of interest, while the vitrimer coating did not significantly lessen the damage experienced during rain erosion, the addition of vitrimer composite coatings(5 wt.% mica addition) did result in a crack-resistant, durable coating capable of self-healing behavior and in all cases the angle of rain exposure was the most critical parameter explored. It is crucial to continue exploring this space where vitrimer coatings are of interest for both their self-healing properties and potential use as reversible adhesives.

17 WIND ENERGY↗

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In vivo stabilization of a less toxic asparaginase variant leads to a durable antitumor response in acute leukemia

Asparagine is a non-essential amino acid since it can either be taken up via the diet or synthesized by asparagine synthetase. Acute lymphoblastic leukemia (ALL) cells do not express asparagine synthetase or express it only minimally, which makes them completely dependent on extracellular asparagine for their growth and survival. This dependency makes ALL cells vulnerable to treatment with L-asparaginase, an enzyme that hydrolyzes asparagine. To date, all clinically approved L-asparaginases have significant L-glutaminase co-activity, associated with non-immune related toxic side effects observed during therapy. Therefore, reduction of L-glutaminase co-activity with concomitant maintenance of its anticancer L-asparaginase effect may effectively improve the tolerability of this unique drug. Previously, we designed a new alternative variant of Erwinia chrysanthemi (ErA; Erwinaze) with decreased L-glutaminase co-activity, while maintaining its L-asparaginase activity, by the introduction of three key mutations around the active site (ErA-TM). However, Erwinaze and our ErA-TM variant have very short half-lives in vivo. Here, we show that the fusion of ErA-TM with an albumin binding domain (ABD)-tag significantly increases its in vivo persistence. In addition, we evaluated the in vivo therapeutic efficacy of ABD-ErA-TM in a B-ALL xenograft model of SUP-B15. Our results show a comparable long-lasting durable antileukemic effect between the standard-of-care pegylated-asparaginase and ABD-ErA-TM L-asparaginase, but with fewer co-glutaminase-related acute side effects. Since the toxic side effects of current L-asparaginases often result in treatment discontinuation in ALL patients, this novel ErA-TM variant with ultra-low L-glutaminase co-activity and long in vivo persistence may have great clinical potential.

60 APPLIED LIFE SCIENCES↗

Machine tests crease durability of sheet materials

To test the crease resistance of sheet materials, the mid-section is folded over crease-control blades. One end is clamped to a motor-driven eccentric, the other to a spring, and durability is measured by the cycles required to produce failure.

Jones, L. K.↗

Double copper sheath multiconductor instrumentation cable is durable and easily installed in high thermal or nuclear radiation area

Multiconductor instrumentation cable in which the conducting wires are routed through two concentric copper tube sheaths, employing a compressed insulator between the conductors and between the inner and outer sheaths, is durable and easily installed in high thermal or nuclear radiation area. The double sheath is a barrier against moisture, abrasion, and vibration.

Mc Crae, A. W., Jr.↗

Durability tests of a five centimeter diameter ion thruster system

A modified Hughes SIT-5 system is being tested for durability at the Lewis Research Center. As of October 1, 1972, the thruster subsystem has logged over 8000 hours of operation. The initial 2023 hours were run with a translating screen thrust vector grid. The thruster is currently operating with an electrostatic type vector grid. Profiles and maps taken at widely separated intervals show that performance and operating characteristics have remained essentially constant. Overall efficiency is about 32 percent and power to thrust ratio is 170 watts per millipound at a specific impulse of 2500 seconds. Telescopic examination of the vector grid shows some sputtering erosion due to charge exchange and direct impingement ions.

Nakanishi, S.↗

A 2000-Hour Durability Test of a 5-Centimeter Diameter Mercury Bombardment Ion Thruster

A 2000-hour durability test of a modified Hughes SIT-5 (Structurally Integrated Thruster, 5 cm) was conducted at the Lewis Research Center. The thruster operated with a translating screen thrust vector grid locked in position for 10 deg beam deflection. The test was essentially continuous except for seven stoppages of beam current. The neutralizer keeper voltage and thruster floating potential increased slightly with time. Performance profiles and maps of thruster characteristics were obtained at 453 and 2023 hours into the test. Overall efficiency was nearly constant at 31 - 32 percent, and operating characteristics were similar at both points in the test. A post-shutdown inspection showed negligible erosion damage to the accelerator and cathode baffle. Some erosion was found in the aperture of the neutralizer cathode.