Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Mitigation for Removal of Building 01-202681 in the Main Storage Yard of the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

The Main Storage Yard was originally recorded as SHPO Resource No. S2772 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and as contributing to the significance of the potential Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed). The Main Storage Yard retains all seven aspects of integrity. The location, design, materials, workmanship, feeling, and association have not changed since the original construction. Since the purpose of the yard is to maintain storage equipment that is actively being used, the design and feeling will change each time equipment is moved. Such actions reinforce the integrity of design and feeling. Buildings 01-101 and 01-102 were removed (Collins and Menocal 2020), but the other buildings and storage yard remain. Therefore, the setting has been changed, but not to the degree that the Main Storage Yard no longer conveys its significance (see Figures 4 and 5 for comparison). The Main Storage Yard was designed to facilitate the relocation of the Area 3 Subdock to Area 1 in 1985. The design for the overall Subdock provided a centralized cluster of buildings surrounded by two large storage yards. While the North Storage Yard largely serves as overflow storage, the Main Storage Yard holds the majority of drill rigs and drilling equipment needed to support big hole drilling. The Main Storage Yard and its contents were essential elements of the nuclear testing drilling program on the NNSS thus making it eligible for the NRHP under Criterion A for its contribution to broad patterns of history by storing specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is an engineered landscape that now serves as an open-air repository of drilling technology and nuclear testing. In addition to its individual significance, the Main Storage Yard also contributes to the significance of the Area 1 Subdock Historic District as it showcases a variety of big-hole drilling equipment, support facilities, and warehouses that were specially designed for nuclear testing at the NNSS. Despite the demolition of two contributing elements to date, the district still contains numerous examples of other facilities with the purpose of supporting big-hole drilling; therefore, the district still remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Case Study - Propane School Bus Fleets

As part of the U.S. Department of Energy’s (DOE’s) effort to deploy transportation technologies that reduce U.S. dependence on imported petroleum, this study examines five school districts, one in Virginia and four in Texas, successful use of propane school buses. These school districts used school buses equipped with the newly developed liquid propane injection system that improves vehicle performance. Some of the school districts in this study saved nearly 50% on a cost per mile basis for fuel and maintenance relative to diesel. Using Argonne National Laboratory’s Alternative Fuel Life-Cycle Environmental and Economic Transportation (AFLEET) Tool developed for the DOE’s Clean Cities program to help Clean Cities stakeholders estimate petroleum use, greenhouse gas (GHG) emissions, air pollutant emissions and cost of ownership of light-duty and heavy-duty vehicles, the results showed payback period ranges from 3—8 years, recouping the incremental cost of the vehicles and infrastructure. Overall, fuel economy for these propane vehicles is close to that of displaced diesel vehicles, on an energy-equivalent basis. In addition, the 110 propane buses examined demonstrated petroleum displacement, 212,000 diesel gallon equivalents per year, and GHG benefits of 770 tons per year.

Alvin Independent School District↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

Large scale energy analysis and renovation strategies for social housing in the historic city of Venice

Social houses built after the Second World War to accommodate workers and low-income families represent one of the major energy consumers and greenhouse gas emitters in the residential sector. Plans for their renovation are underway in all European countries, and the process is more complicated for Italian cities due to the lack of space and the large number of historical buildings. This study addresses this challenge by proposing a methodology to renovate a low-income district in the city of Venice using CityBES to model and evaluate energy conservation measures. CityBES is a web-based tool that allows users to employ urban building energy modeling for large-scale energy and retrofit analyses of building stocks. In the case study conducted for Venice's Santa Marta district, due to the particular context, four common energy conservation measures covering both the building envelope and heat generation boilers have been applied. The evaluation of energy-saving performances at the district level showed that the four measures together achieved 67% energy savings, an abatement in energy cost equal to 67%, and annual carbon dioxide emissions reduction of 1.1 MtCO 2 . Furthermore, the case study demonstrates a method and workflow replicable for energy retrofit analysis of building stocks in other historical districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The evolving role of geothermal energy for decarbonizing the United States

Geothermal energy is often referred to as a niche technology that is too localized, too small or too expensive to make much of a difference in how renewable energy will be supplied in a fully decarbonized future. As a result, geothermal energy has been undervalued in terms of what it could provide to complement, rather than compete with, electricity generation from wind, solar photovoltaic, concentrating solar power and other renewables. Geothermal energy systems are fully dispatchable and can provide baseload or load-following electric power or heat suitable for a wide range of applications including supplying district heating for communities and cities, and heating and cooling of individual buildings. The focus of our study is on the potential of utilizing geothermal energy for providing heat for buildings and industry at lower temperatures, a substitute for the combustion of fossil fuels. Because heating represents about 20% (20 EJ per year) of the annual primary energy consumption in the U.S.—with most of it coming from burning natural gas, oil and/or propane in furnaces—deploying geothermal heating on a national scale could have a significant impact on lowering carbon emissions. In heating-dominated states in the U.S. Northern Tier, heating often is among the largest contributors to the state's carbon footprint. This review begins with a discussion of the motivation and rationale behind considering geothermal as a key low-carbon heating option for the U.S. The study summarizes the U.S. geothermal resource and describes the applications and main engineering components of using geothermal energy for heating and cooling, electric power generation, and co-generation using district heating, geothermal heat pumps, and power conversion with steam flashing and organic Rankine plants. Environmental benefits and impacts are described. An extensive discussion of geologic and thermal-hydraulic aspects of the subsurface is included in the review because of their critical role in determining reservoir designs at specific sites to ensure sufficient productivity that is both safe and economically viable. Models for estimating levelized costs of district heating are used to show how costs are affected by reservoir performance, infrastructure capital costs, and financial parameters. Here, the review concludes with an assessment of technical subsurface issues associated with reservoir performance and the economic requirements for providing geothermal heating in district heating systems at a sufficient scale to have an impact on decarbonizing the U.S.

15 GEOTHERMAL ENERGY↗

Soil Dust Aerosols and Wind as Predictors of Seasonal Meningitis Incidence in Niger

Epidemics of meningococcal meningitis are concentrated in sub-Saharan Africa during the dry season, a period when the region is affected by the Harmattan, a dry and dusty northeasterly trade wind blowing from the Sahara into the Gulf of Guinea. We examined the potential of climate-based statistical forecasting models to predict seasonal incidence of meningitis in Niger at both the national and district levels. We used time series of meningitis incidence from 1986 through 2006 for 38 districts in Niger. We tested models based on data that would be readily available in an operational framework, such as climate and dust, population, and the incidence of early cases before the onset of the meningitis season in January–May. Incidence was used as a proxy for immunological state, susceptibility, and carriage in the population. We compared a range of negative binomial generalized linear models fitted to the meningitis data. At the national level, a model using early incidence in December and averaged November–December zonal wind provided the best fit (pseudo-R2 = 0.57), with zonal wind having the greatest impact. A model with surface dust concentration as a predictive variable performed indistinguishably well. At the district level, the best spatiotemporal model included zonal wind, dust concentration, early incidence in December, and population density (pseudo-R2 = 0.41). We showed that wind and dust information and incidence in the early dry season predict part of the year-to-year variability of the seasonal incidence of meningitis at both national and district levels in Niger. Models of this form could provide an early-season alert that wind, dust, and other conditions are potentially conducive to an epidemic.

59 BASIC BIOLOGICAL SCIENCES↗

Urbanization and malaria have a contextual relationship in endemic areas: A temporal and spatial study in Ghana

In West Africa, malaria is one of the leading causes of disease-induced deaths. Existing studies indicate that as urbanization increases, there is corresponding decrease in malaria prevalence. However, in malaria-endemic areas, the prevalence in some rural areas is sometimes lower than in some peri-urban and urban areas. Therefore, the relationship between the degree of urbanization, the impact of living in urban areas, and the prevalence of malaria remains unclear. This study explores this association in Ghana, using epidemiological data at the district level (2015–2018) and data on health, hygiene, and education. We applied a multilevel model and time series decomposition to understand the epidemiological pattern of malaria in Ghana. Then we classified the districts of Ghana into rural, peri-urban, and urban areas using administratively defined urbanization, total built areas, and built intensity. We converted the prevalence time series into cross-sectional data for each district by extracting features from the data. To predict the determinant most impacting according to the degree of urbanization, we used a cluster-specific random forest. We find that prevalence is impacted by seasonality, but the trend of the seasonal signature is not noticeable in urban and peri-urban areas. While urban districts have a slightly lower prevalence, there are still pockets with higher rates within these regions. These areas of high prevalence are linked to proximity to water bodies and waterways, but the rise in these same variables is not associated with the increase of prevalence in peri-urban areas. The increase in nightlight reflectance in rural areas is associated with an increased prevalence. We conclude that urbanization is not the main factor driving the decline in malaria. However, the data indicate that understanding and managing malaria prevalence in urbanization will necessitate a focus on these contextual factors. Finally, we design an interactive tool, ’malDecision’ that allows data-supported decision-making.

60 APPLIED LIFE SCIENCES↗

COVID-19-associated school closures and related efforts to sustain education and subsidized meal programs, United States, February 18-June 30, 2020

Pre-emptive school closures are frontline community mitigation measures recommended by the US Centers for Disease Control and Prevention (CDC) for implementation during severe pandemics. This study describes the spatiotemporal patterns of publicly announced school closures implemented in response to the coronavirus disease 2019 (COVID-19) pandemic and assesses how public K-12 districts adjusted their methods of education delivery and provision of subsidized meals. During February 18–June 30, 2020, we used daily systematic media searches to identify publicly announced COVID-19–related school closures lasting ≥1 day in the United States (US). We also collected statewide school closure policies from state government websites. Data on distance learning and subsidized meal programs were collected from a stratified sample of 600 school districts. The first COVID-19–associated school closure occurred on February 27, 2020 in Washington state. By March 30, 2020, all but one US public school districts were closed, representing the first-ever nearly synchronous nationwide closure of public K-12 schools in the US. Approximately 100,000 public schools were closed for ≥8 weeks because of COVID-19, affecting >50 million K-12 students. Of 600 districts sampled, the vast majority offered distance learning (91.0%) and continued provision of subsidized meal programs (78.8%) during the closures. Despite the sudden and prolonged nature of COVID-19–associated school closures, schools demonstrated flexibility by implementing distance learning and alternate methods to continue subsidized meal programs.

60 APPLIED LIFE SCIENCES↗

DESCRIPTION OF ACTIVITIES AND SELECTED RESULTS FOR THE U.S. DEPARTMENT OF ENERGY S CLEAN ENERGY APPLICATION CENTERS: FISCAL YEAR 2010

The U.S. Department of Energy (DOE) sponsors a set of Clean Energy Application Centers that promote the development and deployment of clean energy technologies. There are eight regional centers that provide assistance for specific areas of the country plus a separate center operated by the International District Energy Association that provides technical assistance on district energy issues and applications to the regional centers. The original focus of the centers was on combined heat and power (CHP) alone but, beginning in fiscal year 2010, their scope expanded to include district energy systems and waste heat recovery. At that time, the official name of the centers changed from CHP Regional Application Centers (RACs) to Clean Energy Application Centers, and their number was expanded to include the previously-mentioned center focusing on district energy. Oak Ridge National Laboratory (ORNL) has performed two previous studies of RAC activities. The first one examined what the RACs had done each year from the initiation of the program through fiscal year (FY) 2008 and the second one examined RAC activities for the 2009 fiscal year. The most recent study, described in this report, examines what was accomplished in fiscal year 2010, the first year since the RACs expanded their focus and changed their name to Clean Energy Application Centers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Playing Hot and Cold: How Can Russian Heat Policy Find Its Way Toward Energy Efficiency?

The Russian district heating has a large energy-saving potential, and, therefore, need for investments. The scale of needed investments is significant: the government estimates that 70 percent of the district heating infrastructure needs replacement or maintenance, a reflection of decades of under investment. Government budgets will be unable to cover them, and iInvolvingement ofthe private industry will be critical to attracting the necessary investementis necessary. For private parties to invest in district heating facilities across Russia, and not only in pockets of already successful enterprises, regulators have to develop a comprehensive policy that works district heating systems under various conditionscost-reflective tariffs, metering, incentives for efficiency and social support for the neediest (instead of subsidies for all).

Roshchanka, Volha↗

Recovery Act: Analysis of Low-Temperature Utilization of Geothermal Resources (Final Technical Report)

Full realization of the potential of what might be considered “low-grade” geothermal resources will require that we examine many more uses for the heat than traditional electricity generation. To demonstrate that geothermal energy truly has the potential to be a national energy source we will be designing, assessing, and evaluating innovative uses for geothermal-produced water such as hybrid biomass-geothermal cogeneration of electricity and district heating and efficiency improvements to the use of cellulosic biomass in addition to utilization of geothermal in district heating for community redevelopment projects. The objectives of this project were: 1) to perform a techno-economic analysis of the integration and utilization potential of low-temperature geothermal sources. Innovative uses of low-enthalpy geothermal water were designed and examined for their ability to offset fossil fuels and decrease CO 2 emissions. 2) To perform process optimizations and economic analyses of processes that can utilize low-temperature geothermal fluids. These processes included electricity generation using biomass and district heating systems. 3) To scale up and generalize the results of three case study locations to develop a regionalized model of the utilization of low-temperature geothermal resources. A national-level, GIS-based, low-temperature geothermal resource supply model was developed and used to develop a series of national supply curves. We performed an in-depth analysis of the low-temperature geothermal resources that dominate the eastern half of the United States. The final products of this study include 17 publications, an updated version of the cost estimation software GEOPHIRES, and direct-use supply curves for low-temperature utilization of geothermal resources. The supply curves for direct use geothermal include utilization from known hydrothermal, undiscovered hydrothermal, and near-hydrothermal EGS resources and presented these results at the Stanford Geothermal Workshop. We also have incorporated our wellbore model into TOUGH2-EGS and began coding TOUGH2-EGS with the wellbore model into GEOPHIRES as a reservoir thermal drawdown option. Additionally, case studies for the WVU and Cornell campuses were performed to assess the potential for district heating and cooling at these two eastern U.S. sites.

15 GEOTHERMAL ENERGY↗

Intelligent Facades for High Performance Green Buildings

Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets. With a team that spans multiple stakeholders across disparate industries, from CPV to A&E partners that are responsible for the design and development of District and Regional Scale Urban Development, this project demonstrates that integrating utility-scale high efficiency CPV installations with urban and suburban environments is both viable and desirable within the marketplace. The historical schism between utility scale CPV and BIPV has been one of differing scale and cultures. There is no technical reason why utility-scale CPV cannot be located within urban embedded district scale sites of energy harvesting. New models for leasing large areas of district scale roofs and facades are emerging, such that the model for utility scale energy harvesting can be reconciled to commercial and public scale building sites and campuses. This consortium is designed to unite utility scale solar harvesting into building applications for smart grid development.

14 SOLAR ENERGY↗

Ir-Rational Number Institute Report 2017-2018

The 2017 – 2018 Los Alamos National Laboratory Math and Science Academy Ir-Rational Number Institute (IrRNI) six-all-day sessions were held on Northern New Mexico College campus (NNMC) between September 2017 and March 2018. The IrRNI included 7 Northern New Mexico school districts (Bloomfield Public Schools, Cuba Independent Schools, Española Public Schools, Los Alamos Public Schools, Pojoaque Valley School District, Pecos Independent School District and Santa Fe Public Schools) and one Bureau of Indian Education school district, Jemez Day School, located in Jemez Pueblo. Twenty-nine teachers of mathematics, kindergarten through eighth grade, 2 principals, 1 STEM Coordinator, and 1 New Mexico Public Education Math and Science Bureau staffer* attended regularly and were eligible for a Certificate of Completion or Certificate of Engagement on the last day of instruction ( 20 participants were new to the IrRNI and 13 were returnees from the previous year or the MSA Summer Institute).

97 MATHEMATICS AND COMPUTING↗

Historic Architectural Resource Survey of the Dosimetry Applications Research (DOSAR) Facility in the 7700 Area of the Oak Ridge National Laboratory

In May 2022, Cultural Resource Analysts, Inc., completed a historic architectural resource survey of buildings associated with the Dosimetry Applications Research Facility at the Oak Ridge National Laboratory. The laboratory is one of three Department of Energy facilities located on the Oak Ridge Reservation in Roane and Anderson Counties, Tennessee. The Dosimetry Applications Research Facility is located approximately 2 mi southeast of the main Oak Ridge National Laboratory campus. The survey included Buildings 7709, 7710, and 7712, which date to the 1960s. An additional DOSAR building (Building 7735) dates to the late 1980s and was not surveyed since it is outside the period of significance. The survey was conducted at the request of UT-Battelle, LLC, on behalf of the Department of Energy. As stipulated by the National Historic Preservation Act of 1966, as amended, the Department of Energy is required to identify any properties under its jurisdiction that are included in or eligible for inclusion in the National Register of Historic Places. In order to identify historic properties at the Oak Ridge National Laboratory, in 2017–2018 Cultural Resource Analysts, Inc., conducted a survey of the main campus as well as outlying facilities, publishing the findings in a 2018 report entitled Oak Ridge National Laboratory Historic Architectural Resource Survey. At the time of the 2017–2018 survey, buildings associated with the Dosimetry Applications Research Facility were not accessible for security reasons and the current report serves as an addendum to the 2018 report. In addition, the current survey incorporates information included in a documentation report on Building 7709 completed in 2019. The properties included in the current survey were also evaluated for their collective potential as a historic district. The identification of archaeological properties that are eligible for inclusion in the National Register of Historic Places is beyond the scope of this report. Cultural Resource Analysts, Inc., recommends that none of the buildings surveyed for the current report are individually eligible for listing in the National Register of Historic Places. However, the collective of buildings represents a facility that made notable contributions to the Oak Ridge National Laboratory’s scientific research endeavors from the 1960s to the 1980s, specifically in the field of Health Physics. The buildings and their associated features have also maintained their integrity of setting, materials, design, location, and association. Therefore, Cultural Resource Analysts, Inc., proposes the Dosimetry Applications Research Facility Historic District, which is recommended eligible for listing under Criterion A. The three buildings addressed in the current survey (Buildings 7709, 7710, and 7712) are recommended eligible as contributing resources of the historic district. The district boundary is scribed to incorporate the environs of these three facilities, as well as additional relevant features.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Evaluation of small area crop estimation techniques using LANDSAT- and ground-derived data

Studies completed in fiscal year 1981 in support of the clustering/classification and preprocessing activities of the Domestic Crops and Land Cover project. The theme throughout the study was the improvement of subanalysis district (usually county level) crop hectarage estimates, as reflected in the following three objectives: (1) to evaluate the current U.S. Department of Agriculture Statistical Reporting Service regression approach to crop area estimation as applied to the problem of obtaining subanalysis district estimates; (2) to develop and test alternative approaches to subanalysis district estimation; and (3) to develop and test preprocessing techniques for use in improving subanalysis district estimates.

Amis, M. L.↗

Remote sensing for rural development planning in Africa

Multilevel remote-sensing techniques were combined to provide land resource and land-use information for rural development planning in Arusha Region, Tanzania. Enhanced Landsat imagery, supplemented by low-level aerial survey data, slope angle data from topographic sheets, and existing reports on vegetation and soil conditions, was used jointly by image analysts and district-level land-management officials to divide the region's six districts into land-planning units. District-planning officials selected a number of these land-planning units for priority planning and development activities. For the priority areas, natural color aerial photographs provided detailed information for land-use planning discussions between district officials and villagers. Consideration of the efficiency of this remote sensing approach leads to general recommendations for similar applications. The technology and timing of data collection and interpretation activities should allow maximum participation by intended users of the information.

Dunford, C.↗

City Scale Modeling with OpenStudio

Assessing the impact of energy efficiency technologies at a district or city scale is of great interest to local governments, real estate developers, utility companies, and policymakers. This paper describes a flexible framework that can be used to create and run district and city scale building energy simulations. The framework is built around the new OpenStudio City Database (CityDB). Building footprints, building height, building type, and other data can be imported from public records or other sources. Missing data can be inferred or assigned from a statistical sampling of other datasets. Once all required data is available, OpenStudio Measures are used to create starting point energy models and to model energy efficiency measures for each building. Together this framework allows a user to pose several scenarios such as 'what if 30% of the commercial retail buildings added rooftop solar' or 'what if all elementary schools converted to ground source heat pumps' and then visualize the impacts at a district or city scale. This paper focuses on modeling existing building stock using public records. However, the framework is capable of supporting the evaluation of new construction, district systems, and the use of proprietary data sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗