Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Networked Microgrids for Grid Resilience, Robustness, and Efficiency: A Review

Networked microgrids (NMGs) are clusters of microgrids that are physically connected and functionally interoperable. The massive and unprecedented deployment of smart grid technologies, new business models, and involvement of new stakeholders enable NMGs to be a conceptual operation paradigm for future distribution systems. Much work needs to be done, however, to enable NMGs to achieve seamless coordination, including physical, communication, and functional integration. In this paper, we review and summarize the state-of-the-art methodologies for operation and control of NMGs. Furthermore, we also specifically discuss the notion of dynamic boundaries for advanced microgrid applications. In addition, we introduce the opportunities, challenges, and possible solutions regarding NMGs for improving grid resilience, robustness, and efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Wind Market Report: 2022 Edition

The U.S. Department of Energy’s (DOE’s) annual Distributed Wind Market Report analyzes distributed wind projects of all sizes to provide stakeholders with market statistics and analysis along with insights into market trends and characteristics. By providing a comprehensive overview of the distributed wind market, this report can help guide future investments and decisions by industry, utilities, federal and state agencies, and other interested parties. This report provides key information to help stakeholders understand and access market opportunities and inform distributed wind industry research and development needs.

17 WIND ENERGY↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Light Bender Concept for Power Distribution on a Lunar Base

Power generation and distribution is a challenge for a future lunar base. A promising concept for lunar power distribution is the light bender—a system that utilizes autonomously deployed mirrors to reflect sunlight to shaded regions on the lunar surface. The light bender system consists of two components: tandem reflector mirrors (TRM) which reflect sunlight to a permanently shaded region and the Cassegrain Fresnel distribution optics (CFDO) which collects the reflected light from the TRM and redirects light to local consumer nodes. This paper describes the light bender system concepts and the associated system analysis and technology development performed as part of a 2021 NASA Innovative Advanced Concepts (NIAC) phase I award.

Bradford Robertson↗

The Light Bender Concept for Power Distribution on a Lunar Base

Power generation and distribution is a challenge for a future lunar base. A promising concept for lunar power distribution is the light bender—a system that utilizes autonomously deployed mirrors to reflect sunlight to shaded regions on the lunar surface. The light bender system consists of two components: tandem reflector mirrors (TRM) which reflect sunlight to a permanently shaded region and the Cassegrain Fresnel distribution optics (CFDO) which collects the reflected light from the TRM and redirects light to local consumer nodes. This paper describes the light bender system concepts and the associated system analysis and technology development performed as part of a 2021 NASA Innovative Advanced Concepts (NIAC) phase I award.

Bradford Robertson↗

Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/electrical power generation subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C)/Electrical Power Generation (EPG) hardware. The EPD and C/EPG hardware is required for performing critical functions of cryogenic reactant storage, electrical power generation and product water distribution in the Orbiter. Specifically, the EPD and C/EPG hardware consists of the following components: Power Section Assembly (PSA); Reactant Control Subsystem (RCS); Thermal Control Subsystem (TCS); Water Removal Subsystem (WRS); and Power Reactant Storage and Distribution System (PRSDS). The IOA analysis process utilized available EPD and C/EPG hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

Patton, Jeff A.↗

Perpendicular heating of electrons by upper hybrid waves generated by a ring distribution

Satellite observations of electron conical distributions with enhanced fluxes just outside the loss cone suggest that telectrons have been heated perpendicularly to the magnetic field in the mid-altitude polar magnetosphere. To understand electron conical distributions, plasma simulations are conducted to examine an upper hybrid wave instability of a ring electron distribution perpendicular to the magnetic field in a cold electron background. The simulations indicate that both the cold and ring distributions are heated perpendicularly during the saturation stage. From the plasma data, a ring distribution can be identified as a trapped distribution function with an enhancement near 90-deg pitch angle in the phase space density plot. It is suggested that the ring distribution might provide an additional free energy source for generating upper hybrid waves associated with electron conical events.

Lin, C. S.↗

Generation of electron conical distributions by upper hybrid waves in the earth's polar region

The heating of electron populations through resonant wave-particle interaction with upper hybrid turbulence is examined. It is first demonstrated that upper hybrid waves are easily excited by a population of warm electrons with a loss cone type distribution in a background of cold electron plasma. Quasi-linear theory is then used to show that the upper hybrid turbulence can preferentially heat the warm electrons in the perpendicular direction. In analogy to ion conic formation, this perpendicular heating process is a viable mechanism of generating electron conical distributions observed in the Earth's midaltitude polar regions.

Wong, H. K.↗

Simulating self-powered neutron detector responses to infer burnup-induced power distribution perturbations in next-generation light water reactors

Understanding how 3D power distribution will be monitored throughout reactor core volumetric space in next-generation nuclear power reactors is crucial to the design, deployment, and licensing of these reactors. Although numerous techniques exist for 3D power distribution monitoring based on the response of both in situ and ex situ sensors currently implemented or proposed for use in the US reactor fleet, crucial details about these techniques are often unclear. The publicly available documentation does not include information such as how well these techniques are characterized and optimized in their implementations and the levels of uncertainty in the inferred 3D power distribution. The work described herein investigated a recently developed 3D power distribution inferencing method as applied to two next-generation reactor simulations: (1) the NuScale small modular reactor design and (2) the Westinghouse AP1000 design, both of which contain in-core strings of vanadium self-powered neutron detectors (SPNDs). This investigation considered a range of SPND string sensor densities, as well as a range of 3D power distribution axial segment sizes. In this work, SPND response simulation is informed by neutron flux calculations in representative homogenized cores. For the different sensor densities and power distribution axial segment sizes in these simulations, the average solution error, solver iterations, and run time were tracked to parameterize the sensor-core configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent Orbiter Assessment (IOA): Assessment of the Electrical Power Distribution and Control/Electrical Power Generation (EPD and C/EPG) FMEA/CIL

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Electrical Power Distribution and Control/Electrical Power Generation (EPD and C/EPG) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison was provided through additional analysis as required. The results of that comparison is documented for the Orbiter EPD and C/EPG hardware. The IOA product for the EPD and C/EPG analysis consisted of 263 failure mode worksheets that resulted in 42 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 211 FMEA and 47 CIL items.

Mccants, C. N.↗

A Proton-Cyclotron Wave Storm Generated by Unstable Proton Distribution Functions in the Solar Wind

We use audification of 0.092 seconds cadence magnetometer data from the Wind spacecraft to identify waves with amplitudes greater than 0.1 nanoteslas near the ion gyrofrequency (approximately 0.1 hertz) with duration longer than 1 hour during 2008. We present one of the most common types of event for a case study and find it to be a proton-cyclotron wave storm, coinciding with highly radial magnetic field and a suprathermal proton beam close in density to the core distribution itself. Using linear Vlasov analysis, we conclude that the long-duration, large-amplitude waves are generated by the instability of the proton distribution function. The origin of the beam is unknown, but the radial field period is found in the trailing edge of a fast solar wind stream and resembles other events thought to be caused by magnetic field footpoint motion or interchange reconnection between coronal holes and closed field lines in the corona.

instabilities - plasmas↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Dynamic Adaptive Relaying for Distribution Grids with High Inverter-Based Generation

The penetration of distributed energy resources (DERs) in distribution systems is rapidly increasing. This can lead to large variations in the operating load and the fault current seen by a relay, which can impact the reliability of overcurrent protection. Adaptive overcurrent relaying (AOCR) can address this concern by enabling the relay to adjust its pickup settings based on the system operating conditions. This paper presents a novel dynamic AOCR approach that allows the relays to locally estimate the pickup settings and dynamically modify them. The approach is based on a two-stage estimation algorithm that uses local measurements and system information to estimate the worst-case fault current and the relay pickup settings. The relay pickup settings are then dynamically modified based on the estimated fault current. The performance of the proposed approach is evaluated on multiple configurations of the EPRI J1 feeder and the IEEE 13-bus system. The results show that the proposed approach can effectively improve the reliability of overcurrent protection in distribution systems with DERs.

adaptive overcurrent protection↗

Distribution functions in plasmas generated by a volume source of fission fragments

The role played by fission fragments and electron distribution functions in nuclear pumped lasers is considered and procedures for their calculations are outlined. The calculations are illustrated for a He-3/Xe mixture where fission is provided by the He-3(n,p)H-3 reaction. Because the dominant ion in the system depends on the Xe fraction, the distribution functions cannot be determined without the simultaneous consideration of a detailed kinetic model. As is the case for wall sources of fission fragments, the resulting plasmas are essentially thermal but the electron distribution functions are non-Maxwellian.

Deese, J. E.↗

Parameterization in Grid Generation

The distribution of grid points for calculating the solution of partial differential equations is chosen so as to include consideration of truncation error, stability, and the resolution of the solution near boundary layers and shocks. It is important to specify the distribution of points along a grid line. The problem of distributing points along a curve is considered. It is assumed that the curve is defined parametrically. The objective is to select a set of parameter values so that the corresponding points on the curves are properly distributed. The distribution is based on some intrinsic property of the curve such as arc length or curvature.

Mastin, C. W.↗

FINAL PROJECT REPORT SBIR Phase II Next Generation Power Converters for Distributed Wind Applications

Intergrid, LLC, based in Temple, New Hampshire, conducted an 24-month DOE SBIR Phase II research program to develop next-generation electronic power inverters and converters for the United States distributed wind (DW) market. The distributed wind segment is defined as turbines rated from 10 kW to 1 MW, a market segment that has been almost entirely blocked by the absence of UL1741-certified, commercially available inverters.

17 WIND ENERGY↗