Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Investigation on paper cup waste degradation by bacterial consortium and Eudrillus eugeinea through vermicomposting

Highlights: • This piece of work high lights the addition of microbial consortia to the vermin bin reduces the period of degradation of paper cup waste. • This study proves the degradation of paper cup waste through the instrumental analysis like FT-IR, SEM and XRD. • This experimental work leads to the fine separation of polyethylene terephthalate (PET) from paper cups through the action of microbial consortium. • This work highlights the reuse of waste (paper cup waste) into value added product (Organic manure). - Abstract: Disposable Paper cups are a threat to the environment and are composed of 90% high strength paper with 5% thin coating of polyethylene. This polyethylene prevents the paper cup from undergoing degradation in the soil. Hence, in the present study two different approaches towards the management of paper cup waste through vermicomposting technology has been presented. The experimental setup includes 2 plastic reactors namely Vermicompost (VC) (Cow dung + Paper cup waste + Earthworm (Eudrillus eugeinea)) and Vermicompost with bacterial consortium (VCB) (Cow dung + Paper cup waste + Eudrillus eugeinea + Microbial consortia such as Bacillus anthracis, B. endophyticus, B. funiculus, B. thuringiensis, B. cereus, B. toyonensis, Virigibacillius chiquenigi, Acinetobacter baumanni and Lactobacillus pantheries). After treatment the physicochemical parameters were analysed. The results showed that the values of TOC (26.52 and 37.47%), TOM (36.01 and 33.13%) and C/N (15.02 and 11.92%) ratio are reduced in both VC and VCB whereas, the values of pH (8.01 and 7.56), EC (1.2–1.9 µs{sup −1} and 1.4–1.9 µs{sup −1}), TP (46.1 and 51%), TMg (50.52 and 64.3%), TCa (50 and 64%), TNa (1.39 and 1.75%) and TK (1.75 and 1.86%) have increased. This study substantiates the addition of the microbial consortia augmenting the degradation in VCB reactor by reducing the period of process from 19 to 12 weeks. Further the characterisation of the vermicompost prepared from paper cup with FT-IR shows high degradation of carboxylic and aliphatic group; SEM analysis shows the disaggregation of cellulose and lignin; XRD shows the degradation of cellulose. All these analyses endorse the degradation of the paper cup waste faster with microbes (VCB). Thus, this present study high lights management of the paper cup waste in a relatively short period of time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-A-9A-07: X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption

Purpose: To assess whether X-ray acoustic computed tomography (XACT) is more sensitive to X-ray absorption than that of the conventional X-ray imaging. Methods: First, a theoretical model was built to analyze the X-ray absorption sensitivity of XACT imaging and conventional X-ray imaging. Second, an XACT imaging system was developed to evaluate the X-ray induced acoustic signal generation as well as the sensitivity improvement over transmission x-ray imaging. Ultra-short x-ray pulses (60-nanosecond) were generated from an X-ray source operated at the energy of 150 kVp with a 10-Hz repetition rate. The X-ray pulse was synchronized with the acoustic detection via a x-ray scintillation triggering to acquire the X-ray induced acoustic signal. Results: Theoretical analysis shows that X-ray induced acoustic signal is sensitive only to the X-ray absorption, while completely insensitive to out the X-ray scattering and fluorescence. XACT has reduced background and increased contrast-to-noise ratio, and therefore has increased sensitivity compared to transmission x-ray imaging. For a 50-μm size, gadolinium insertion in tissue exposed to 40 keV X-rays; the sensitivity of XACT imaging is about 28.9 times higher than that of conventional X-ray imaging. Conclusion: X-ray acoustic computer tomography (XACT) as a new imaging modality combines X-ray absorption contrast and high ultrasonic resolution in a single modality. It is feasible to improve the imaging sensitivity with XACT imaging compared with conventional X-ray imaging. Taking advantage of the high ultrasonic resolution, it is possible to perform 3-D imaging with a single x-ray pulse with arrays of transducers without any mechanical motion of the imaging system. This single-shot capability offers the potential of reducing radiation dose by a factor of 1000, and imaging 100 times faster when compared to the conventional X-ray CT, and thus revolutionizing x-ray imaging applications in medicine and biology. The authors gratefully acknowledge the Department of Defense Prostate Cancer Research Programs W81XWH-13-1-0481 (LX), the National Institutes of Health 1R01 CA133474 and 1R21 A153587, and SRFDP (20124407120012) for funding.

60 APPLIED LIFE SCIENCES↗

Minimizing Experimental Setup Time and Effort at APS beamline 1-ID through Instrumentation Design

Sector 1-ID at the APS accommodates a number of dif-ferent experimental techniques in the same spatial enve-lope of the E-hutch end station. These include high-energy small and wide angle X-ray scattering (SAXS and WAXS), high-energy diffraction microscopy (HEDM, both near and far field modes) and high-energy X-ray tomography. These techniques are frequently combined to allow the users to obtain multimodal data, often attaining 1 μm spatial resolution and <0.05º angular resolution. Furthermore, these techniques are utilized while the sam-ple is thermo-mechanically loaded to mimic real operat-ing conditions. The instrumentation required for each of these techniques and environments has been designed and configured in a modular way with a focus on stability and repeatability between changeovers. This approach allows the end station to be more versatile, capable of collecting multi-modal data in-situ while reducing time and effort typically required for set up and alignment, resulting in more efficient beam time use. Key instrumentation de-sign features and layout of the end station are presented.

Benda, Erika↗

Optomechanical structure for a multifunctional hard x-ray nanoprobe instrument

A multifunctional hard x-ray nanoprobe instrument for characterization of nanoscale materials and devices includes a scanning probe mode with a full field transmission mode. The scanning probe mode provides fluorescence spectroscopy and diffraction contrast imaging. The full field transmission mode allows two-dimensional (2-D) imaging and tomography. The nanoprobe instrument includes zone plate optics for focusing and imaging. The nanoprobe instrument includes a stage group for positioning the zone plate optics. The nanoprobe instrument includes a specimen stage group for positioning the specimen. An enhanced laser Doppler displacement meter (LDDM) system provides two-dimensional differential displacement measurement in a range of nanometer resolution between the zone-plate optics and the sample holder. A digital signal processor (DSP) implements a real-time closed-loop feedback technique for providing differential vibration control between the zone-plate optics and the sample holder.

Shu, Deming↗

Shielding maze design for Line C tunnel at LANSCE - 25456

The Los Alamos Neutron Science Center (LANSCE) is a major experimental facility at Los Alamos National Laboratory. The LANSCE linear accelerator (linac) supplies proton beams to five experimental areas simultaneously. The Isotope Production Facility (IPF) utilizes a 100-MeV beam after the first stage of acceleration, all other facilities use proton beams at 800 MeV. However, the facility can support sole-use experiments at 200-600 MeV proton beam energies. There are three spallation neutron sources providing neutrons in different energy regimes: Weapons Neutron Research (WNR), Lujan Neutron Scattering Center (Lujan Center) and the Ultra Cold Neutron source (UCN). The proton radiography (pRAD) facility utilizes the energetic proton beam for imaging and tomography directly. The beam to pRAD and UCN facilities is delivered via line X that splits into line C (pRAD) and line B (UCN). Due to engineering access controls it is impossible to deliver beam to UCN while the pRAD facility is occupied. The goal of our project was to design a shielding maze arrangement for line C to allow for simultaneous beam delivery to UCN while pRAD area (dome) is occupied. (authors)

43 PARTICLE ACCELERATORS↗

Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry

After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of pore structures and cracking in cement paste exposed to elevated temperatures by X-ray computed tomography

When cement-based materials are exposed to the high temperatures induced by fire, which can rapidly cause temperatures of over 1000 °C, the changes in pore structure and density prevail. In the present study, mortar specimens were subjected to a series of increasing temperatures to explore the temperature-dependent evolution of internal pore structure. High-performance X-ray computed tomography (CT) was used to observe the evolution of temperature-induced discontinuities at the sub-millimeter level. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were employed to investigate the cause of physical changes in the heated mortar specimens. Results exhibit the changes in pore structure caused by elevated temperatures, and thermally induced fractures. We discuss the progressive formation of thermally induced fracture networks, which is a prerequisite for spalling failure of cement-based materials by fire, based on visual observations of the 3D internal structures revealed by X-ray CT.

36 MATERIALS SCIENCE↗

Characterization of the crystal structure, kinematics, stresses and rotations in angular granular quartz during compaction

Three-dimensional X-ray diffraction (3DXRD), a method for quantifying the position, orientation and elastic strain of large ensembles of single crystals, has recently emerged as an important tool for studying the mechanical response of granular materials during compaction. Applications have demonstrated the utility of 3DXRD and X-ray computed tomography (XRCT) for assessing strains, particle stresses and orientations, inter-particle contacts and forces, particle fracture mechanics, and porosity evolution in situ . Although past studies employing 3DXRD and XRCT have elucidated the mechanics of spherical particle packings and angular particle packings with a small number of particles, there has been limited effort to date in studying angular particle packings with a large number of particles and in comparing the mechanics of these packings with those composed of a large number of spherical particles. Therefore, the focus of the present paper is on the mechanics of several hundred angular particles during compaction using in situ 3DXRD to study the crystal structure, kinematics, stresses and rotations of angular quartz grains. Comparisons are also made between the compaction response of angular grains and that of spherical grains, and stress-induced twinning within individual grains is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of the effects of different tempers and aging temperatures on the precipitation behavior of Al-Mg (5.25at.%)-Mn alloys

We investigated the effects of different tempers (H131 and H116) and different aging temperatures (50 and 70 °C) on the precipitation behavior of Al-Mg (5.25 at.%)-Mn (Al 5083) alloys aged for a long time (41 and 30 months) using electron backscatter diffraction(EBSD), scanning transmission electron microscopy(STEM), energy-dispersive X-ray spectroscopy(EDS), atom probe tomography (APT), and small angle neutron scattering (SANS). Results for the GP zones and β'' phases were found in Al 5083 H116 aged at 50 °C for 24 months using APT. EDS and SANS revealed that a phase transformation process from GP zones to β'/β phases occurred for precipitates formed in both Al 5083 H131 and H116 aged at 70 °C. The effective diffusion coefficient of Mg in Al 5083 H131 is 1.8 times of that in Al 5083 H116 aged at 70 °C. The precipitation process in Al 5083 H116 aged at 50 °C is much slower than that in the sample aged at 70 °C. Finally, we identified the coarsening process in Al 5083 H131 and H116 aged at 70 °C for > 9 months.

36 MATERIALS SCIENCE↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Laser Scattering Tomography for the Study of Defects in Protein Crystals

The goal of this research is to explore the application of the non-destructive technique of Laser Scattering Tomography (LST) to study the defects in protein crystals and relate them to the x-ray diffraction performance of the crystals. LST has been used successfully for the study of defects in inorganic crystals and. in the case of lysozyme, for protein crystals.

Feigelson, Robert S.↗

The Diamond Beamline I13L for Imaging and Coherence

I13L is the first long beamline at Diamond dedicated to imaging and coherence. Two independent branches will operate in the energy range of 6-30 keV with spatial resolution on the micro- to nano-lengthscale. The Imaging branch is dedicated to imaging and tomography with In-line phase contrast and full-field microscopy on the micron to nano-length scale. Ultimate resolution will be achieved on the Coherence branch at I13L with imaging techniques in the reciprocal space. The experimental stations will be located about 250 m from the source, taking advantage of the coherence properties of the source. The beamline has some outstanding features such as the mini-beta layout of the storage ring's straight section. The optical layout is optimized for beam stability and high optical quality to preserve the coherent radiation. In the experimental stations several methods will be available, starting for the first user with in-line phase contrast imaging on the imaging branch and Coherent X-ray Diffraction (CXRD) on the coherence branch.

43 PARTICLE ACCELERATORS↗

Semi-Automated, Object-Based Tomography of Dislocation Structures

The characterization of the three-dimensional arrangement of dislocations is important for many analyses in materials science. Dislocation tomography in transmission electron microscopy is conventionally accomplished through intensity-based reconstruction algorithms. Although such methods work successfully, a disadvantage is that they require many images to be collected over a large tilt range. Here, we present an alternative, semi-automated object-based approach that reduces the data collection requirements by drawing on the prior knowledge that dislocations are line objects. Our approach consists of three steps: (1) initial extraction of dislocation line objects from the individual frames, (2) alignment and matching of these objects across the frames in the tilt series, and (3) tomographic reconstruction to determine the full three-dimensional configuration of the dislocations. Drawing on innovations in graph theory, we employ a node-line segment representation for the dislocation lines and a novel arc-length mapping scheme to relate the dislocations to each other across the images in the tilt series. We demonstrate the method for a dataset collected from a dislocation network imaged by diffraction-contrast scanning transmission electron microscopy. Based on these results and a detailed uncertainty analysis for the algorithm, we discuss opportunities for optimizing data collection and further automating the method.

47 OTHER INSTRUMENTATION↗

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE↗

Boron Removal by Adsorption on Cobalt(II) Doped Chitosan Bio-composite

Cobalt(II) doped chitosan bio-composite was prepared, characterized and used to oxoborate separation from aqueous solutions. The adsorption process was carried out in a batch system. The effect of pH, temperature, time and initial boron concentration on the boron adsorption were tested. The maximum boron adsorption was reached at pH range 8.0–8.5 at room temperature and within 60 min. Calculations based on Langmuir and Freundlich models showed the heterogeneous nature of boron adsorption on Co-CTS bio-composite. On the base of research on optimization of pH and results from XRD and FTIR analysis it was found that boron adsorption by Co-CTS occurred through the co-precipitation and adsorption of B on cobalt hydroxide following the Coulomb attraction of B(OH){sub 4}{sup −} species on positively charged sites and molecular attraction of H{sub 3}BO{sub 3} through hydrogen bond with amine or hydroxyl groups of chitosan. The modelling of the thermodynamic data indicated the nonspontaneous and exothermic nature of the adsorption process. The pseudo-second-order model adequately described the boron adsorption on Co-CTS hydrogel. Desorption by means of alkaline solution at pH 12 was carried out successfully. Adsorption–desorption efficiencies in 3 cycles were almost 100%.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-performance and stable AgSbTe 2 -based thermoelectric materials for near room temperature applications

AgSbTe 2 -based ternary chalcogenides show excellent thermoelectric performance at low- and middle-temperature ranges, yet their practical applications are greatly limited by their intrinsic poor thermodynamic stability. In this work, we demonstrate that AgSbTe 2 -based ternary chalcogenides can be stabilized for service below their decomposition threshold. A series of Ag x Sb 2-x Te 3-x (x = 1.0, 0.9, 0.8 and 0.7) samples have been prepared by the melt-quenching method. Among them, phase pure Ag 0.9 Sb 1.1 Te 2.1 is verified by comprehensive structural characterizations from macroscale by X-ray diffraction to microscale by energy-dispersive spectroscopy and then to sub-nanometer scale by atom probe tomography. This composition is further chosen for the stability investigation. The decomposition threshold of Ag 0.9 Sb 1.1 Te 2.1 appears around 473K. Below this temperature, the chemical compositions and thermoelectric properties are barely changed even after 720 h annealing at 473 K. The figure-of-merit (zT) value of Ag 0.9 Sb 1.1 Te 2.1 below the decomposition threshold is very competitive for real applications even compared with Bi 2 Te 3 -based alloys. The average zT of Ag 0.9 Sb 1.1 Te 2.1 at 300–473 K reaches 0.84, which is higher than most other thermoelectric materials in a similar temperature range, promising applications in miniaturized refrigeration and power generation near room temperature.

36 MATERIALS SCIENCE↗

Effect of laser power on defect, texture, and microstructure of a laser powder bed fusion processed 316L stainless steel

The effect of laser power on defect characteristics, microstructure development, constituent phases, and crystallographic texture was studied on a laser powder bed fusion (L-PBF) processed 316L stainless steel. A series of cylindrical specimens were additively manufactured as a function of laser power ranging from 380 to 200W with a fixed scan speed of 300 mm/s using a selective laser melting system. The density (in terms of count, surface area, and porosity), size (mean values of major axis length, surface area, and volume), shape (aspect ratio and sphericity), and orientation (in terms of the angle between the major axis and build direction) of macroscopic defects in as-printed L-PBF cylinders were characterized using high-resolution synchrotron x-ray computed microtomography with a 0.65μm resolution. Moreover, the changes in the preferred crystallographic orientations and constituent phases were investigated using high-energy synchrotron x-ray diffraction. Finally, the melt pool shape and grain size/orientation were analyzed using metallography. The results show that the porosity increases linearly from 0.13 to 0.88% with the decrease in laser power. However, even with the decrease in laser power by about half and corresponding seven-fold increase in porosity, the 200W case can still be considered as nearly fully dense. On the other hand, with the same decrease in the laser power, the melt pool size/shape, grain size, and texture changed significantly. In conclusion, the role of energy input in the simultaneous changes in defect properties and microstructure development will be discussed.

36 MATERIALS SCIENCE↗