Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Deformation and strain hardening of different steels in impact dominated systems

Strain hardening is a common technique to exploit the full potential of materials in diverse applications. Single impact studies were performed to evaluate work hardening effects of different steels, correlated to their deformation at different energy and momentum levels. Three different steels were examined regarding their forming behavior and their tendency to strain harden in impact loading conditions, revealing different intensities of hardness increase, deformation and coinciding microstructural changes. Detailed studies in the deformed zone such as micro hardness mappings were performed to reveal the materials hardness increase in the deformed zones. Additionally high resolution scanning electron microscopy (HRSEM) supported by electron backscatter diffraction (EBSD) was used to determine microstructural changes. Results indicate, that the influence of different velocities/strain rates at constant energy levels cannot be neglected for the strain hardening behavior of steels and provide data for a better control of the hardness increase in impact dominated materials fabrication operations. - Highlights: • Deformation and strain hardening behaviour of three different steels. • Influence of impact energies and momenta on the strain hardening. • Hardness increase and depth controllable by momentum and energy.

36 MATERIALS SCIENCE↗

Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methods was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of control strategies for different smart window combinations using computer simulations

Several studies have shown that the use of switchable windows could lower the energy consumption of buildings. Since the main function of windows is to provide daylight and visual contact with the external world, high visible transmittance is needed. From an energy perspective it is always best to have the windows in their low-transparent state whenever there are cooling needs, but this is generally not preferable from a daylight and visual contact point of view. Therefore a control system, which can be based on user presence, is needed in connection with switchable windows. In this study the heating and cooling needs of the building, using different control mechanisms were evaluated. This was done for different locations and for different combinations of switchable windows, using electrochromic glazing in combination with either low-e or solar control glazing. Four control mechanisms were investigated; one that only optimizes the window to lower the need for heating and cooling, one that assumes that the office is in use during the daytime, one based on user presence and one limiting the perpendicular component of the incident solar irradiation to avoid glare and too strong daylight. The control mechanisms were compared using computer simulations. A simplified approach based on the balance temperature concept was used instead of performing complete building simulations. The results show that an occupancy-based control system is clearly beneficial and also that the best way to combine the panes in the switchable window differs depending on the balance temperature of the building and on the climate. It is also shown that it can be beneficial to have different window combinations for different orientations. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interaction of celecoxib with different anti-cancer drugs is antagonistic in breast but not in other cancer cells

Celecoxib, an inhibitor of cyclooxygenase-2, is being investigated for enhancement of chemotherapy efficacy in cancer clinical trials. This study investigates the ability of cyclooxygenase-2 inhibitors to sensitize cells from different origins to several chemotherapeutic agents. The effect of the drug's mechanism of action and sequence of administration are also investigated. The sensitivity, cell cycle, apoptosis and DNA damage of five different cancer cell lines (HeLa, HCT116, HepG2, MCF7 and U251) to 5-FU, cisplatin, doxorubicin and etoposide {+-} celecoxib following different incubation schedules were analyzed. We found antagonism between celecoxib and the four drugs in the breast cancer cells MCF7 following all incubation schedules and between celecoxib and doxorubicin in all cell lines except for two combinations in HCT116 cells. Celecoxib with the other three drugs in the remaining four cell lines resulted in variable interactions. Mechanistic investigations revealed that celecoxib exerts different molecular effects in different cells. In some lines, it abrogates the drug-induced G2/M arrest enhancing pre-mature entry into mitosis with damaged DNA thus increasing apoptosis and resulting in synergism. In other cells, it enhances drug-induced G2/M arrest allowing time to repair drug-induced DNA damage before entry into mitosis and decreasing cell death resulting in antagonism. In some synergistic combinations, celecoxib-induced abrogation of G2/M arrest was not associated with apoptosis but permanent arrest in G1 phase. These results, if confirmed in-vivo, indicate that celecoxib is not a suitable chemosensitizer for breast cancer or with doxorubicin for other cancers. Moreover, combination of celecoxib with other drugs should be tailored to the tumor type, drug and administration schedule. - Graphical abstract: Display Omitted Highlights: > Celecoxib may enhance effects of anticancer drugs. > Its combination with four drugs was tested in five cancer cell lines. > It antagonized the effects of the four drugs in the breast cancer cell line MCF7. > Doxorubicin's cytotoxic effects were antagonized by celecoxib in four cell lines. > Cell cycle, apoptosis and DNA damage explain the different interactive effects.

60 APPLIED LIFE SCIENCES↗

Sex-specific differences in hyperoxic lung injury in mice: Implications for acute and chronic lung disease in humans

Sex-specific differences in pulmonary morbidity in humans are well documented. Hyperoxia contributes to lung injury in experimental animals and humans. The mechanisms responsible for sex differences in the susceptibility towards hyperoxic lung injury remain largely unknown. In this investigation, we tested the hypothesis that mice will display sex-specific differences in hyperoxic lung injury. Eight week-old male and female mice (C57BL/6J) were exposed to 72 h of hyperoxia (FiO{sub 2} > 0.95). After exposure to hyperoxia, lung injury, levels of 8-iso-prostaglandin F{sub 2} alpha (8-iso-PGF 2α) (LC–MS/MS), apoptosis (TUNEL) and inflammatory markers (suspension bead array) were determined. Cytochrome P450 (CYP)1A expression in the lung was assessed using immunohistochemistry and western blotting. After exposure to hyperoxia, males showed greater lung injury, neutrophil infiltration and apoptosis, compared to air-breathing controls than females. Pulmonary 8-iso-PGF 2α levels were higher in males than females after hyperoxia exposure. Sexually dimorphic increases in levels of IL-6 (F > M) and VEGF (M > F) in the lungs were also observed. CYP1A1 expression in the lung was higher in female mice compared to males under hyperoxic conditions. Overall, our results support the hypothesis that male mice are more susceptible than females to hyperoxic lung injury and that differences in inflammatory and oxidative stress markers contribute to these sex-specific dimorphic effects. In conclusion, this paper describes the establishment of an animal model that shows sex differences in hyperoxic lung injury in a temporal manner and thus has important implications for lung diseases mediated by hyperoxia in humans. - Highlights: • Male mice were more susceptible to hyperoxic lung injury than females. • Sex differences in inflammatory markers were observed. • CYP1A expression was higher in females after hyperoxia exposure.

60 APPLIED LIFE SCIENCES↗

Hormone-dependence of sarin lethality in rats: Sex differences and stage of the estrous cycle

Chemical warfare nerve agents (CWNAs) are highly toxic compounds that cause a cascade of symptoms and death, if exposed casualties are left untreated. Numerous rodent models have investigated the toxicity and mechanisms of toxicity of CWNAs, but most are limited to male subjects. Given the profound physiological effects of circulating gonadal hormones in female rodents, it is possible that the daily cyclical fluctuations of these hormones affect females' sensitivity to the lethal effects of CWNAs, and previous reports that included female subjects did not control for the stage of the hormonal cycle. The aim of the current study was to determine the 24-hour median lethal dose (LD{sub 50}) of the CWNA sarin in male, ovariectomized (OVEX) female, and female rats during different stages of the estrous cycle (diestrus, proestrus, and estrus). Additionally, baseline activity levels of plasma acetylcholinesterase, butyrylcholinesterase, and carboxylesterase were measured to determine differences among the groups. Results indicated that females in proestrus had a significantly higher LD{sub 50} of sarin compared to OVEX and estrous females. Although some sex differences were observed in the activity levels of plasma esterases, they were not consistent and likely not large enough to significantly affect the LD{sub 50}s. These results suggest that hormonal cyclicity can influence the outcome of CWNA-related studies using female rodents, and that this variability can be minimized by controlling for the stage of the cycle. Additional research is necessary to determine the precise mechanism of the observed differences because it is unlikely to be solely explained by plasma esterase activity. - Highlights: • The LD{sub 50} of sarin was determined in female rats throughout the stages of the estrous cycle. • Females in proestrus had a significantly higher LD{sub 50} compared to estrous or ovariectomized females. • No sex differences were observed between male and female rats. • It is unlikely that plasma esterase activity underlies the observed differences in LD{sub 50}s.

60 APPLIED LIFE SCIENCES↗

Lipopolysaccharide and lipoteichoic acid influence milk production ability via different early responses in bovine mammary epithelial cells

Highlights: • LPS and LTA affect on the milk production of lactating BMECs in different manners. • LPS/TLR4 and LTA/TLR2 signaling induce different innate immune responses in BMECs. • Inhibition of p38 and NF-κB may help recover decrease in milk production in mastitis. Lipopolysaccharide (LPS) and lipoteichoic acid (LTA) are cell wall components of Escherichia coli and Staphylococcus aureus, which cause clinical and subclinical mastitis, respectively. However, the reason of the difference in symptoms by pathogen type remains unclear. In this study, the influence of LPS and LTA on early response and milk production in lactating bovine mammary epithelial cells (BMECs) was comparatively investigated. The results showed that LPS decreased the secretion of β-casein, lactose, and triglycerides, whereas LTA decreased the secretion of lactose and triglycerides but increased lactoferrin production without any influence on β-casein secretion. In addition, the influence of milk lipid droplet size in BMECs and gene expression related to milk fat synthesis was different between LPS and LTA. LPS increased the gene expression of interleukin (IL)-1β, tumor necrosis factor-α, and IL-8 through the activation of the nuclear factor-κB (NF-κB), p38, and c-Jun N-terminal kinase pathways, whereas LTA increased IL-1β and CC chemokine ligand 5 expression through the activation of the NF-κB pathway. Moreover, these cytokines and chemokines differently affected the milk production ability of BMECs. These results suggested that the pathogen-specific symptoms may be related to the differences in the early response of BMECs to bacterial toxins.

60 APPLIED LIFE SCIENCES↗

Reconciling Differences between Lipid Transfer in Free-Standing and Solid Supported Membranes: A Time-Resolved Small-Angle Neutron Scattering Study

Maintaining compositional lipid gradients across membranes in animal cells is essential to biological function, but what is the energetic cost to maintain these differences? It has long been recognized that studying the passive movement of lipids in membranes can provide insight into this toll. Confusingly the reported values of inter- and, particularly, intra-lipid transport rates of lipids in membranes show significant differences. To overcome this difficulty, biases introduced by experimental approaches have to be identified. The present study addresses the difference in the reported intramembrane transport rates of dimyristoylphosphatidylcholine (DMPC) on flat solid supports (fast flipping) and in curved free-standing membranes (slow flipping). Two possible scenarios are potentially at play: one is the difference in curvature of the membranes studied and the other the presence (or not) of the support. Using DMPC vesides and DMPC supported membranes on silica nanoparticles of different radii, we found that an increase in curvature (from a diameter of 30 nm to a diameter of 100 nm) does not change the rates significantly, differing only by factors of order I. Additionally, we found that the exchange rates of DMPC in supported membranes are similar to the ones in vesicles. And as previously reported, we found that the activation energies for exchange on free-standing and supported membranes are similar (84 and 78 kJ/mol, respectively). However, DMPC's flip-flop rates increase significantly when in a supported membrane, surpassing the exchange rates and no longer limiting the exchange process. Although the presence of holes or cracks in supported membranes explains the occurrence of fast lipid flip-flop in many studies, in defect-free supported membranes we find that fast flip-flop is driven by the surface's induced disorder of the bilayer's acyl chain packing as evidenced from their broad melting temperature behavior.

Wah, Benny↗

Pedestal formation via different trajectories in the stability space in response to the timing scan of neutral beam heating in DIII-D

The frequency of type-I ELMs decreases as the initiation of the neutral beam injection (NBI) heating is delayed with respect to the time when plasma current (I p ) reaches flat-top in the ITER Baseline Scenario discharges in DIII-D. Henceforth, the time gap between the NBI initiation and I p flat-top will be referred to as “heating delay.” As the heating delay is modified, pedestal formation follows different trajectories in the edge current density–pedestal pressure gradient (j edge -∇p e ped ) space from the L-H transition toward the first ELM event. During the stationary phase after the first ELM, the ELM frequency (f ELM ) decreases by a factor of ~2 as the heating delay is increased. A longer pedestal recovery time in the inter-ELM period is observed for the low f ELM discharges as compared to the high f ELM discharges. Both low and high f ELM discharges show nearly identical profiles of electron density and temperature and have a similar MHD stability just before an ELM crash. However, a marked difference is observed in the magnetic spectrogram of the high and low f ELM discharges in response to the variation in the heating delay. The main difference is in the 200–400 kHz range of the magnetic spectra. A quasi-coherent mode (QCM) at 220 kHz and weaker broadband fluctuations are observed in the high f ELM discharges, while only strong broadband fluctuations are prevalent in the low f ELM discharges. ELM-synchronized analysis shows that the time evolution of these modes is different for the high and low f ELM discharges. The localization of both these modes is confirmed at the maximum gradient region of the pedestal. We hypothesize that these modes cause important pedestal transport and that the difference in the pedestal recovery of the high and low f ELM discharges is a result of the difference in transport driven by these modes, as they change with changes in the heating delay. It is demonstrated experimentally for the first time that discharges with similar pedestal parameters can carry the history of the heating delay into the stationary phase and that changes in turbulent-driven transport are a likely cause of changes in f ELM observed with variations of heating delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural differences between yeast and mammalian microtubules revealed by cryo-EM

Microtubules are polymers of αβ-tubulin heterodimers essential for all eukaryotes. Despite sequence conservation, there are significant structural differences between microtubules assembled in vitro from mammalian or budding yeast tubulin. Yeast MTs were not observed to undergo compaction at the interdimer interface as seen for mammalian microtubules upon GTP hydrolysis. Lack of compaction might reflect slower GTP hydrolysis or a different degree of allosteric coupling in the lattice. The microtubule plus end–tracking protein Bim1 binds yeast microtubules both between αβ-tubulin heterodimers, as seen for other organisms, and within tubulin dimers, but binds mammalian tubulin only at interdimer contacts. At the concentrations used in cryo-electron microscopy, Bim1 causes the compaction of yeast microtubules and induces their rapid disassembly. In conclusion, our studies demonstrate structural differences between yeast and mammalian microtubules that likely underlie their differing polymerization dynamics. These differences may reflect adaptations to the demands of different cell size or range of physiological growth temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

EARLY-TYPE GALAXIES AT z {approx} 1.3. II. MASSES AND AGES OF EARLY-TYPE GALAXIES IN DIFFERENT ENVIRONMENTS AND THEIR DEPENDENCE ON STELLAR POPULATION MODEL ASSUMPTIONS

We have derived masses and ages for 79 early-type galaxies (ETGs) in different environments at z {approx} 1.3 in the Lynx supercluster and in the GOODS/CDF-S field using multi-wavelength (0.6-4.5 {mu}m; KPNO, Palomar, Keck, Hubble Space Telescope, Spitzer) data sets. At this redshift the contribution of the thermally pulsing asymptotic giant branch (TP-AGB) phase is important for ETGs, and the mass and age estimates depend on the choice of the stellar population model used in the spectral energy distribution fits. We describe in detail the differences among model predictions for a large range of galaxy ages, showing the dependence of these differences on age. Current models still yield large uncertainties. While recent models from Maraston and Charlot and Bruzual offer better modeling of the TP-AGB phase with respect to less recent Bruzual and Charlot models, their predictions do not often match. The modeling of this TP-AGB phase has a significant impact on the derived parameters for galaxies observed at high redshift. Some of our results do not depend on the choice of the model: for all models, the most massive galaxies are the oldest ones, independent of the environment. When using the Maraston and Charlot and Bruzual models, the mass distribution is similar in the clusters and in the groups, whereas in our field sample there is a deficit of massive (M {approx}> 10{sup 11} M{sub sun}) ETGs. According to those last models, ETGs belonging to the cluster environment host on average older stars with respect to group and field populations. This difference is less significant than the age difference in galaxies of different masses.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SIZE DIFFERENCE BETWEEN RED AND BLUE GLOBULAR CLUSTERS IS NOT DUE TO PROJECTION EFFECTS

Metal-rich (red) globular clusters in massive galaxies are, on average, smaller than metal-poor (blue) globular clusters. One of the possible explanations for this phenomenon is that the two populations of clusters have different spatial distributions. We test this idea by comparing clusters observed in unusually deep, high signal-to-noise images of M87 with a simulated globular cluster population in which the red and blue clusters have different spatial distributions, matching the observations. We compare the overall distribution of cluster effective radii as well as the relationship between effective radius and galactocentric distance for both the observed and simulated red and blue sub-populations. We find that the different spatial distributions does not produce a significant size difference between the red and blue sub-populations as a whole or at a given galactocentric distance. These results suggest that the size difference between red and blue globular clusters is likely due to differences during formation or later evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of the low temperature transcriptomes and CBF regulons of three plant species that differ in freezing tolerance: Solanum commersonii, Solanum tuberosum, and Arabidopsis thaliana

Solanum commersonii and Solanum tuberosum are closely related plant species that differ in their abilities to cold acclimate; whereas S. commersonii increases in freezing tolerance in response to low temperature, S. tuberosum does not. In Arabidopsis thaliana, cold-regulated genes have been shown to contribute to freezing tolerance, including those that comprise the CBF regulon, genes that are controlled by the CBF transcription factors. The low temperature transcriptomes and CBF regulons of S. commersonii and S. tuberosum were therefore compared to determine whether there might be differences that contribute to their differences in ability to cold acclimate. The results indicated that both plants alter gene expression in response to low temperature to similar degrees with similar kinetics and that both plants have CBF regulons composed of hundreds of genes. However, there were considerable differences in the sets of genes that comprised the low temperature transcriptomes and CBF regulons of the two species. Thus differences in cold regulatory programmes may contribute to the differences in freezing tolerance of these two species. However, 53 groups of putative orthologous genes that are cold-regulated in S. commersonii, S. tuberosum, and A. thaliana were identified. Given that the evolutionary distance between the two Solanum species and A. thaliana is 112–156 million years, it seems likely that these conserved coldregulated genes—many of which encode transcription factors and proteins of unknown function—have fundamental roles in plant growth and development at low temperature.

54 ENVIRONMENTAL SCIENCES↗

Proton-proton bremsstrahlung: Consequences of different on-shell-point conditions

Background: Proton-proton bremsstrahlung (pp{gamma}) is investigated both theoretically and experimentally. The pp{gamma} amplitudes can be classified according to the number and location of on-shell points at which they are evaluated. Quantitative understanding of the effect on the pp{gamma} cross section of using different on-shell-point conditions is lacking, but it is essential to identifying the photon emission mechanism governing the pp{gamma} process. Method: Four different pp{gamma} amplitudes, which include four-on-shell-point amplitudes and one-on-shell-point amplitude, are generated from a realistic one-boson-exchange (ROBE) model for pp scattering. These ROBE amplitudes are used to investigate the consequence of using different on-shell-point conditions in calculating the pp{gamma} cross sections. Purpose: We verify the validity of the ROBE pp{gamma} amplitudes. We explore similarities between the four-on-shell-point ROBE and two-u-two-t special (TuTts) soft-photon pp{gamma} amplitudes and important differences with the one-on-shell-point ROBE and Low pp{gamma} amplitudes. We demonstrate that the precision Kernfysisch Versneller Instituut (KVI) data can only be described by the four-on-shell-point (ROBE or TuTts) amplitude. We use the ROBE four-on-shell-point amplitude and one-on-shell-point amplitude to investigate systematically the effect of using different on-shell-point conditions to calculate the pp{gamma} cross section. Furthermore, we identify a general principle that governs the process. This general principle is also applicable to other bremsstrahlung processes involving the scattering of two identical nucleons. Results: (i) The four-on-shell-point ROBE (or TuTts) amplitude describes the high-precision KVI data much better than does the one-on-shell-point ROBE (or Low) amplitude. Although the contribution from the anomalous magnetic moment of the proton is very significant, it does not completely dominate the KVI pp{gamma} cross sections. (ii) The four-on-shell-point ROBE (or TuTts) amplitude describes the TRIUMF data better than does the one-on-shell-point ROBE (or Low) amplitude. (iii) The effect on the pp{gamma} cross section of using different on-shell-point conditions is significant in the hard-photon region, i.e., for small proton scattering angles {theta} (={theta}{sub 3}={theta}{sub 4}, symmetric scattering angles) far from the elastic limit ({theta}{yields}45 deg.); in contrast, the effect becomes insignificant in the vicinity of the elastic limit. Near the limit as {theta} tends to 45 deg. (or as the photon energy K approaches zero), the four-on-shell-point and one-on-shell-point amplitudes approach one another, a general principle applicable to all bremsstrahlung processes because only kinematics is involved. Conclusion: The four-on-shell-point ROBE amplitude provides a quantitative description of pp{gamma} cross sections. The anomalous magnetic moment is an important component of the photon emission mechanism. The four-on-shell-point property of the full ROBE amplitude is essential to properly describing the complete range of the precision KVI data and the TRIUMF data, although the one-on-shell-point ROBE amplitude is adequate in the region near the elastic limit.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demand Response Analysis for Different Residential Personas in a Comfort-Driven Behavioral Context

Low demand response (DR) participation and high program drop-out rates continue to impede DR goals that could save up to $13 billion in annual grid expansion and electricity demand costs. Yet, the literature lacks a thorough understanding of how different residential customer segments enrolled in DR programs respond to utility signals in view of occupant comfort considerations. The objective of this study is to gain a clear understanding of the effects of four different customer personas on residential DR. Given current data limitations, this work developed an array of hypothetical personas with varied priorities, activity levels, and comfort thresholds based on demographic variables that have been found in previous studies to influence energy consumption. A BEopt DR model for a reference residential single-family building located in Colorado was built to isolate the effect of differences in buildings or climate. The results provide useful evidence on how persona-comfort differences lead to significant deviations in DR goals (especially peak demand reduction), ranging from 0.1% to 20%. This work presents a novel framework representing comfort preferences in DR models. The data generated, albeit synthetic, and the results could inform DR program design considerations of how different people respond to different comfort priorities.

BEopt↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-07: A Comparison of SSD and Field Size Dependence of Output for Megavoltage Electron Beams for Different Manufacturers

Purpose: The purpose of this study was to compare the electron beam in-air output factor (H) for Varian and Siemens accelerators. Methods: Measurements were performed among four accelerators: Varian CL2300ix, Varian TrueBeam, Siemens Oncor, and Siemens Primus. The nominal electron energy measured ranges from 6 to 21 MeV. Measurements were made in air using a diode detector for different square cone sizes (6 – 25cm) with circular field inserts with radius r between 1 cm and 8 cm and for different SSD (100 – 120 cm). H is defined asH(r,SSD){sup =} X(r,SSD)/X(open,SSD), where X is the charge measured by the diode detector without buildup cap in air. Results: For the same nominal energy, cone size, radius of circular cutout, and SSD, H agreed within a maximum deviation of 2.3% and standard deviation of 1% among Varian accelerators but can be as much as 8.7% different between the Varian and the Siemens accelerators. H is a function of electron energy and cutout radius only when the field radius for H measured at different SSD is renormalized as r = r0*5/(SSD-95), where r{sub 0} is the physical field radius at the end of the cone. The radius dependence of H for five cone sizes (6×6, 10×10, 15×15, 20×20 and 25×25cm{sup 2}) and three SSD(100, 110 and 120cm) for three energies was measured. Conclusion: The in air output factor (H) measured for the same manufacturer can be treated as identical to within 1.1% for Varian machines and to within 1.6% for Siemens machines, but the difference in H measured for the different manufacturers is large enough (>2%) to require machine specific data set.

43 PARTICLE ACCELERATORS↗