Neutron backscatter edges as a diagnostic of burn propagation

High gain in hotspot-ignition inertial confinement fusion (ICF) implosions requires the propagation of thermonuclear burn from a central hotspot to the surrounding cold dense fuel. As ICF experiments enter the burning plasma regime, diagnostic signatures of burn propagation must be identified. In previous work [A. J. Crilly et al., Phys. Plasmas 27(1), 012701 (2020)], it has been shown that the spectral shape of the neutron backscatter edges is sensitive to the dense fuel hydrodynamic conditions. The backscatter edges are prominent features in the ICF neutron spectrum produced by the 180° scattering of primary deuterium–tritium fusion neutrons from ions. In this work, synthetic neutron spectra from radiation-hydrodynamics simulations of burning ICF implosions are used to assess the backscatter edge analysis in a propagating burn regime. Significant changes to the edge's spectral shape are observed as the degree of burn increases, and a simplified analysis is developed to infer scatter-averaged fluid velocity and temperature. The backscatter analysis offers direct measurement of the increased dense fuel temperatures that result from burn propagation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining spectral response of the National Ignition Facility particle time of flight diagnostic to x rays

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V –1 mm –1 and b = 0.00 ± 0.04 V –1 . Finally, we also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

47 OTHER INSTRUMENTATION↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

Aligning the Thomson scattering and charge exchange recombination diagnostics using neutral beam emission at DIII-D

This work addresses discrepancies in the alignment of the H-mode pedestal profiles of the electron and ion properties in the DIII-D tokamak as measured by Thomson Scattering (TS) and Charge Exchange Recombination Spectroscopy (CER) diagnostics. While the alignment of these profiles is key for accurate studies of tokamak physics and plasma confinement, misalignments can occur due to inaccuracies, such as in magnetic equilibrium reconstructions required to map measurements in different poloidal and toroidal locations. Both FIDASIM, an established simulation package, and a simplified collisional radiative model are used to simulate neutral beam state densities and neutral beam emission. Simulated neutral beam emissions are calculated based on shifted TS profiles and compared to beam emission measurements from the Main Ion CER system to determine the best shift for aligning TS with CER. This analysis is performed on various DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Analysis of an induced Langmuir wave by ponderomotive forces and its applicability for plasma diagnostics

We present a numerical study on the electron and ion density perturbation in low-temperature plasmas driven by the frequency detuning of two intense laser beams. Our study is performed in the hydrodynamic regime, which becomes applicable when the plasma grating period induced by the beating of the laser beams is greater than the Debye length and collective processes such as plasma oscillations can be excited. Our findings show a resonance in electron density perturbation as the frequency detuning approaches a value consistent with the Bohm–Gross dispersion relation in low- and high-pressure plasmas. We discuss the potential of this resonance as a diagnostic tool for precisely measuring electron temperature and density in low-temperature plasmas through coherent scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reaction-in-flight neutrons as a diagnostic for hydrodynamical mixing in double shell inertial confinement fusion capsules

We examine reaction-in-flight (RIF) neutrons as diagnostics for hydrodynamical mixing of high-Z shell material into the hotspot of double shell capsules that are designed for the National Ignition Facility. In particular, we consider the effects of different levels of mixing of tungsten shell material into the DT gas on RIF spectra. Using a set of 1D simulations from the radiation hydrodynamic code xRAGE to determine the temperature and density profiles of the mixed W-DT gas, we find that increasing the mass of mix systematically reduces the ratio of RIF neutrons to primary 14 MeV neutrons. The shape of the RIF spectrum also changes with mix, with the predicted spectrum softening in energy with increasing mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state↗

Preface to the Proceedings of the 25th Topical Conference on High-Temperature Plasma Diagnostics

The 25th Topical Conference on High-Temperature Plasma Diagnostics (HTPD 2024) was held in Asheville, NC, USA, at the Renaissance Asheville Downtown Hotel from 21 to 25 April 2024. This biennial conference brings together scientists and engineers from a variety of fields, including magnetic confinement fusion, inertial confinement fusion, space plasmas, astrophysics, and industrial applications, to discuss mutual problems in the development of instrumentation and experimental techniques for the characterization of high-temperature plasmas. As the 25th meeting, HTPD 2024 represents ∼50 years of ongoing international collaboration on these topics.

Biewer, Theodore [ORNL] (ORCID:0000000174563509)↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.