Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Dynamic characterization, monitoring and control of rotating flexible beam-mass structures via piezo-embedded techniques

A variational principle and a finite element discretization technique were used to derive the dynamic equations for a high speed rotating flexible beam-mass system embedded with piezo-electric materials. The dynamic equation thus obtained allows the development of finite element models which accommodate both the original structural element and the piezoelectric element. The solutions of finite element models provide system dynamics needed to design a sensing system. The characterization of gyroscopic effect and damping capacity of smart rotating devices are addressed. Several simulation examples are presented to validate the analytical solution.

Lai, Steven H.-Y.↗

Optical measurements in rocket engine liquid sprays

The performance of liquid propellant rocket engines is dependent upon many elements of the entire system. One of the most fundamental and most critical is the performance of the injector elements. Their characterization is an important part of the development of combustion devices. Optical measurements within these environments have proven to be invaluable tools in quantifying the physical environment of two phase flows. The effort reported herein involves the measurement of drop velocity, drop size, and most importantly mass flux using Phase-Doppler Particle Anemometry within a spray generated by a single swirl injector element operating in atmospheric pressure conditions. The mass flux has been determined and validated by mechanical patternation methods and by profile integration of the mass flux.

Feikema, Douglas A.↗

Simulation of a Miniature, Low-Power Time-of-Flight Mass Spectrometer for In Situ Analysis of Planetary Atmospheres

We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (less than 1000 cubic centimeters) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions greater than 600 at sensitivity levels on the order of 10(exp -3) cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions approximately 1000, though at the expense of sensitivity and instrument volume.

King, Todd T.↗

Wear and Tear - Mechanical

The focus of this chapter is on the long term wear and tear, or aging, of the mechanical subsystem of a spacecraft. The mechanical subsystem is herein considered to be the primary support structure (as in a skeleton or exoskeleton) upon which all other spacecraft systems rest, and the associated mechanisms. Mechanisms are devices which have some component that moves at least once, in response to some type of passive or active control system. For the structure, aging may proceed as a gradual degradation of mechanical properties and/or function, possibly leading to complete structural failure over an extended period of time. However, over the 50 years of the Space Age such failures appear to be unusual. In contrast, failures for mechanisms are much more frequent and may have a very serious effect on mission performance. Just as on Earth, all moving devices are subject to normal (and possibly accelerated) degradation from mechanical wear due to loss or breakdown of lubricant, misalignment, temperature cycling effects, improper design/selection of materials, fatigue, and a variety of other effects. In space, such environmental factors as severe temperature swings (possibly 100's of degrees C while going in and out of direct solar exposure), hard vacuum, micrometeoroids, wear from operation in a dusty or contaminated environment, and materials degradation from radiation can be much worse. In addition, there are some ground handling issues such as humidity, long term storage, and ground transport which may be of concern. This chapter addresses the elements of the mechanical subsystem subject to wear, and identifies possible causes. The potential impact of such degradation is addressed, albeit with the recognition that the impact of such wear often depends on when it occurs and on what specific components. Most structural elements of the mechanical system typically are conservatively designed (often to a safety factor of greater than approximately 1.25 on yield for unmanned spacecraft) but do not have backup structure due to the added mass this would impose, and also due to the fact that structural elements can be accurately modeled mathematically and in test. Critical mechanisms or devices may have backups, or alternate work-arounds, since characterization of these systems in a 1g environment is less accurate than structure, and repair in-space is often impossible.

Swanson, Theodore↗

Investigation of Seasonal Landscape Freeze/Thaw Cycles in Relation to Cloud Structure in the High Northern Latitudes

The seasonal freezing and thawing of Earth's cryosphere (the portion of Earth's surface permanently or seasonally frozen) has an immense impact on Earth's climate as well as on its water, carbon and energy cycles. During the spring, snowmelt and the transition between frozen and non-frozen states lowers Earth's surface albedo. This change in albedo causes more solar radiation to be absorbed by the land surface, raising surface soil and air temperatures as much as 5 C within a few days. The transition of ice into liquid water not only raises the surface humidity, but also greatly affects the energy exchange between the land surface and the atmosphere as the phase change creates a latent energy dominated system. There is strong evidence to suggest that the thawing of the cryosphere during spring and refreezing during autumn is correlated to local atmospheric conditions such as cloud structure and frequency. Understanding the influence of land surface freeze/thaw cycles on atmospheric structure can help improve our understanding of links between seasonal land surface state and weather and climate, providing insight into associated changes in Earth's water, carbon, and energy cycles that are driven by climate change.Information on both the freeze/thaw states of Earth's land surface and cloud characteristics is derived from data sets collected by NOAA's Special Sensor Microwave/Imager (SSM/I), the Advanced Microwave Scanning Radiometer on NASA's Earth Observing System(AMSR-E), NASA's CloudSat, and NASA's SeaWinds-on-QuickSCAT Earth remote sensing satellite instruments. These instruments take advantage of the microwave spectrum to collect an ensemble of atmospheric and land surface data. Our analysis uses data from radars (active instruments which transmit a microwave signal toward Earth and measure the resultant backscatter) and radiometers (passive devices which measure Earth's natural microwave emission) to accurately characterize salient details on Earth's surface and atmospheric states. By comparing the cloud measurements and the surface freeze-thaw data sets, a correlation between the two phenomena can be developed.

clouds↗

Particulate Sensor Technology Development at NASA Glenn Research Center

GRC has developed multiple innovative particulate sensor technologies for spacecraft cabin environmental monitoring, spacecraft fire safety, and lunar dust characterization. This has been driven by lack of commercial (COTS) devices to meet the volume, mass, power, reliability, and measurement requirements of any given application.

Fischer, David G.↗

Evaluation of asynchronous geiger-mode avalanche photodiode arrays for deep-space optical communications

The NASA Psyche mission is set to explore an asteroid located between Mars and Jupiter with a launch date in 2022. On-board the Psyche spacecraft is experimental demonstrator technology that will allow scientists to explore the capabilities of optical communications – a program called Deep Space Optical Communication (DSOC) led by Jet Propulsion Laboratory (JPL). DSOC seeks to improve communications performance by developing a space-based Flight Laser Transceiver (FLT) and a ground-based transceiver to enable photon-efficient communications with equipment in deep space. An integral part to this FLT system is a high-efficiency photon-counting camera (PCC) that is able to detect both the 1064nm uplink/beacon laser photons and 1550nm downlink laser photons with low background noise, and is capable of withstanding the rigors of space-travel. The paper details the characterization of several asynchronous Geiger-Mode Avalanche Photodiode (GmAPD) arrays developed by MIT Lincoln Laboratory for use in the PCC- specifically evaluating the temperature dependence of background noise, photon detection efficiency at 1064nm and 1550nm wavelengths, pixel lifetime testing, and angle of acceptance measurements. The results of this characterization are used to determine the nominal conditions for the device to operate in while in flight to maintain an efficient link with the ground-based transceiver.

Duerr, E.↗

Dual-Resonator Kinetic-Inductance Detector for Distinction between Signal and 1/ƒ Frequency Noise

Astronomical kinetic inductance detectors (KIDs), similar to quantum information devices, experience performance-limiting noise from materials. In particular, 1/ƒ (frequency) noise arises from two-level system defects (TLSs) in the circuit dielectrics and material interfaces and can be a dominant noise mechanism. Here, we present a dual-resonator KID (DuRKID), which is designed for improved noise-equivalent power relative to standard 1/ƒ -noise-limited KIDs. In this study we present the DuRKID schematic, a fabricated example, our first measurement results, a theoretical model including 1/ƒ noise, and a system-noise model containing additional noise sources. The circuit consists of two superconducting resonators sharing an electrical capacitance bridge of four capacitors, each of which hosts TLSs. The device is intended to operate using hybridization of the modes, which causes TLSs to either couple to one mode or the other, depending upon which capacitor they reside in. In contrast, the signal will affect a resonator inductance and, due to mode hybridization, this causes correlated frequency changes in both modes. Therefore, one can better distinguish the photon signal from the TLS frequency noise. To achieve hybridization, a TiN inductor is current biased to allow tuning of one bare-resonator mode into degeneracy with the other. Measurements show that the resonator modes hybridize as expected. The inter-resonator coupling and unintentional coupling of the two resonators to transmission lines are also characterized in measurements. A quantum information-science model allows device-parameter extraction from experimental data and a 1/ƒ noise analysis with uncorrelated noise. A system-noise analysis of the DuRKID, with comparisons to standard KIDs, is performed with generation-recombination noise and amplifier noise. The study reveals that the DuRKID can exhibit a large performance advantage over TLS-limited KID detectors.

N Forouzani↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

Are Current SEE Test Procedures Adequate for Modern Devices and Electronics Technologies?

Believe it or not, this has been a simplistic look at starting a checklist for SEE testing. Given a memory that has 68 operating modes, when a SEU occurs that changes the mode, just how do you determine what's going on? Laser and microbeam tests can help, but not easily for modern packaged devices. Expanding this approach to other more complex devices such as ADCs or processors as well as analog devices should be considered. The recommendation is to use the existing text standards as the starting point. Just make your own checklist for the device/technology/issues being considered. At HEART 2007, we presented some of the burgeoning challenges associated with single event effect(SEE) testing of modern commercial memories: a) Package, device complexity, test fixture, and data analysis issues were discussed; b) "Complete" SEE Characterization would take 15 years; c) Qualification test costs have a greater than 4 times increase over the last decade. In this talk, we continue to explore the roles of technology with an emphasis on the existing SEE Test Procedures and some of the concerns related to modern devices. The primary objective of the briefing is to provide some overarching guidance concerning the many considerations involved in the formulation of a SEE test plan provided in a " Checklist" format.we note that there is no such thing as a complete check list and that the best approach is to develop a flexible test plan that takes into account the device type and functions, the device technology, circuit and package design, and, of course, test facility and beam characteristics.

LaBel, Kenneth A.↗

Microsampling techniques for infrared spectroscopic analysis of lunar and terrestrial minerals

Microsampling techniques have been developed for infrared analysis of single mineral grains from lunar rocks and dusts, allowing a detailed molecular structure characterization of these complex fine-grained samples. The methods include special devices for isolating single grains, preparing micropellets from the grains, and obtaining in situ microspecular reflectance spectra from grains in polished rock samples. Although specifically developed for the work on lunar samples, the special techniques for single grain infrared analysis were found to be equally useful in studies of complex terrestrial mineral samples. For example, infrared microanalysis has contributed substantially in solving problems concerned with our natural resources, such as the structural characterization of minerals from commercial iron ores, marine deposits, coal, and fly ash derived from coal.

Estep, P. A.↗

Silicon Carbide Epitaxial Films Studied by Atomic Force Microscopy

Silicon carbide (SiC) holds great potential as an electronic material because of its wide band gap energy, high breakdown electric field, thermal stability, and resistance to radiation damage. Possible aerospace applications of high-temperature, high-power, or high-radiation SiC electronic devices include sensors, control electronics, and power electronics that can operate at temperatures up to 600 C and beyond. Commercially available SiC devices now include blue light-emitting diodes (LED's) and high-voltage diodes for operation up to 350 C, with other devices under development. At present, morphological defects in epitaxially grown SiC films limit their use in device applications. Research geared toward reducing the number of structural inhomogeneities can benefit from an understanding of the type and nature of problems that cause defects. The Atomic Force Microscope (AFM) has proven to be a useful tool in characterizing defects present on the surface of SiC epitaxial films. The in-house High-Temperature Integrated Electronics and Sensors (HTIES) Program at the NASA Lewis Research Center not only extended the dopant concentration range achievable in epitaxial SiC films, but it reduced the concentration of some types of defects. Advanced structural characterization using the AFM was warranted to identify the type and structure of the remaining film defects and morphological inhomogeneities. The AFM can give quantitative information on surface topography down to molecular scales. Acquired, in part, in support of the Advanced High Temperature Engine Materials Technology Program (HITEMP), the AFM had been used previously to detect partial fiber debonding in composite material cross sections. Atomic force microscopy examination of epitaxial SiC film surfaces revealed molecular-scale details of some unwanted surface features. Growth pits propagating from defects in the substrate, and hillocks due, presumably, to existing screw dislocations in the substrates, were imaged. Away from local defects, step bunching was observed to yield step heights of hundreds of angstroms, with possible implications for the uniformity of dopants incorporated in SiC devices during fabrication. The quantitative topographic data from the AFM allow the relevant defect information to be extracted, such as the size and distribution of step bunching and the Burgers vector of screw dislocations. These atomic force microscopy results have furthered the understanding of the dynamic epitaxial SiC growth process. A model describing the observed hillock step bunching has been proposed. This cooperation between researchers involved in crystal growth, electronic device fabrication, and surface structural characterization is likely to continue as atomic force microscopy is used to improve SiC films for high-temperature electronic devices for NASA's advanced turbine engines and space power devices, as well as for future applications in the automotive industry.

Source record↗

An error criterion for determining sampling rates in closed-loop control systems

The determination of an error criterion which will give a sampling rate for adequate performance of linear, time-invariant closed-loop, discrete-data control systems was studied. The proper modelling of the closed-loop control system for characterization of the error behavior, and the determination of an absolute error definition for performance of the two commonly used holding devices are discussed. The definition of an adequate relative error criterion as a function of the sampling rate and the parameters characterizing the system is established along with the determination of sampling rates. The validity of the expressions for the sampling interval was confirmed by computer simulations. Their application solves the problem of making a first choice in the selection of sampling rates.

Brecher, S. M.↗

Premixed turbulent flame propagation in microgravity

To reduce pollutant formation there is, at present, an increased interest in employing premixed fuel/air mixture in combustion devices. It is well known that greater control over local temperature can be achieved with premixed flames and with lean premixed mixtures, significant reduction of pollutants such as NO(x) can be achieved. However, an issue that is still unresolved is the predictability of the flame propagation speed in turbulent premixed mixtures, especially in lean mixtures. Although substantial progress has been made in recent years, there is still no direct verification that flame speeds in turbulent premixed flows are highly predictable in complex flow fields found in realistic combustors. One of the problems associated with experimental verification is the difficulty in obtaining access to all scales of motion in typical high Reynolds number flows, since, such flows contain scales of motion that range from the size of the device to the smallest Kolmogorov scale. The overall objective of this study is to characterize the behavior of turbulent premixed flames at reasonable high Reynolds number, Re(sub L). Of particular interest here is the thin flame limit where the laminar flame thickness is much smaller than the Kolmogorov scale. Thin flames occur in many practical combustion devices and will be numerically studied using a recently developed new formulation that is briefly described.

Menon, S.↗

Pyroshock Environments Characterized for Spacecraft Missions

Pyrotechnic shock, or pyroshock, is the transient response of a structure to loading induced by the ignition of pyrotechnic (explosive or propellant activated) devices. These devices are typically used to separate structural systems (e.g., separate a spacecraft from a launch vehicle) and deploy appendages (e.g., solar panels). Pyroshocks are characterized by high peak acceleration, high-frequency content, and short duration. Because of their high acceleration and high-frequency, pyroshocks can cause spaceflight hardware to fail. Verifying by test that spaceflight hardware can withstand the anticipated shock environment is considered essential to mission success. The Earth Observing System (EOS) AM-1 spacecraft for NASA's Mission to Planet Earth is scheduled to be launched on an Atlas IIAS vehicle in 1999, and the NASA Lewis Research Center is the launch vehicle integrator for this NASA Goddard Space Flight Center spacecraft. The EOS spacecraft was subjected to numerous ground shock tests to verify that its scientific instruments and avionics components will withstand the shock-induced vibration produced when the spacecraft separates from the launch vehicle. Shock test data from these tests represent the third largest available pyroshock database in the United States. Future spacecraft missions will directly benefit from the knowledge gained from these tests. The payload separation system used for EOS is a new system that operates by firing six separation nuts. This system was tested to verify its functional operation and to characterize the resulting shock levels. The launch vehicle contractor (Lockheed Martin Astronautics) and spacecraft contractor (Lockheed Martin Missiles & Space) completed 16 separation test firings. This resulted in an unusually large amount of pyroshock data. Typically, only one or two pyroshock test firings are performed for a spacecraft mission. Because of the size of this separation system shock database, engineers were able to perform unique statistical analyses to characterize the distribution of the test data. For example, it was proven that the shock data follow a lognormal distribution, a concept often assumed but rarely proven. The test-to-test repeatability of the shock source level was analyzed, and the effects of various test configurations and separation nut production lots were examined and quantified. Engineers investigated the change in shock level as the shock traveled from the spacecraft separation interface to the avionics components of the upper stage and analyzed the effects of the structural fidelity (simulator versus real) of the components and their weight on vibrational response. In addition, the shock attenuation with distance and across joints was quantified and compared with concepts originally generated in 1970, and the effects of separation nut preload and firing sequences effects were examined. Because of this EOS shock testing and the analyses performed at NASA Lewis, a significant amount of new information on pyroshock and its characteristics is now available to the aerospace industry. We hope that this information will help future spacecraft test planners to perform better and cheaper spacecraft separation shock tests and to better understand their test data.

Hughes, William O.↗

Fabrication and Atomic Force Microscopy Characterization of Molecular Composites of Fullerenes in Aerogel Matrix for Optical Limiting

An optical limiter is a device which exhibits a decrease in the transmittance in a material with an increase in intensity of light. Sol-gel techniques offer many advantages in the fabrication of materials. These materials possess many desirable properties for nonlinear optical (NLO) device applications which include transparency, high thermal and chemical stabilities, very low refractive index and dielectric constants. C60 shows a higher excited state absorption cross section than the ground state absorption cross section over the complete visible spectrum, and the spectrum of the excited state absorption of C60 has the same general shape as the ground state absorption. This fact suggests that fullerenes are ideal optical limiting materials. Aerogels are fabricated by sol-gel processing. One of the key issues is the dispersion of fullerenes into small and uniform pores of silica aerogel host matrices. The aerogel network was characterized by Raman spectroscopy. Atomic force microscopy is a technique with many advantages to characterize the aerogel materials. The morphology of the cleaved surface for a C60/aerogel sample shows that there are long paralleled shaped stripes with 20-30 nm in width and about 500 nm in length on the cleaved surface. The cleaved surface also was etched by 5% HF solution for one minutes, and it became smoother after HF etching. The main feature in on the surface is the spherical particles with the size of few nanometers, and no aggregated fullerenes appear. The fullerenes are well dispersed in the aerogel matrices.

Lu, W. J .↗

Recent Developments in NASA Piezocomposite Actuator Technology

In this paper, we present an overview of recent progress in the development of the NASA Macro-Fiber Composite (MFC) piezocomposite actuator device. This will include a brief history of the development of the MFC, a description of the standard manufacturing process used to fabricate MFC actuators, and a summary of ongoing MFC electromechanical characterization testing. In addition, we describe the development of a prototype single-crystal piezoelectric MFC device, and compare its performance with MFC actuator specimens utilizing conventional piezoceramic materials.

Wilkie, William K.↗

Characterization and Analysis of InGaAsSb Detectors

Profiling of atmospheric CO2 at 2 micron wavelength using the LIDAR technique, has recently gained interest. Although several detectors might be suitable for this application, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the detector signal-to-noise ratio and minimizes the background signal, thereby increasing the device sensitivity and dynamic range. Detectors meeting the above idealized criteria are commercially unavailable for this particular wavelength. In this paper, the characterization and analysis of Sb-based detectors for 2 micron lidar applications are presented. The detectors were manufactured by AstroPower, Inc., with an InGaAsSb absorbing layer and AlGaAsSb passivating layer. The characterization experiments included spectral response, current versus voltage and noise measurements. The effect of the detectors bias voltage and temperature on its performance, have been investigated as well. The detectors peak responsivity is located at the 2 micron wavelength. Comparing three detector samples, an optimization of the spectral response around the 2 micron wavelength, through a narrower spectral period was observed. Increasing the detector bias voltage enhances the device gain at the narrow spectral range, while cooling the device reduces the cut-off wavelength and lowers its noise. Noise-equivalent-power analysis results in a value as low as 4 x 10(exp -12) W/Hz(exp 1/2) corresponding to D* of 1 x 10(exp 10) cmHz(exp 1/2)/W, at -1 V and 20 C. Discussions also include device operational physics and optimization guidelines, taking into account peculiarity of the Type II heterointerface and transport mechanisms under these conditions.

Abedin, M. Nurul↗