Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

Experimental Verification of the Parabolic Deformable Mirror for the ExoSpec Project

For the Habitable Worlds Observatory, it is essential to broaden the controllable wavelength bandwidth for high-contrast imaging and spectroscopy to increase the exoEarth yield and characterization. The Parabolic Deformable Mirrors (PDM) under the NASA Headquarters directed ExoSpec Work package is specifically tailored to do so. We have successfully procured a generation 1 (Gen 1) PDM device and completed in-depth characterization of the device. This robust evaluation has become instrumental in informing subsequent stages of development, particularly in shaping the design and specifying requirements for the next generation, Gen2, PDM device. We have built a testbed in an environmentally controlled cleanroom to experimentally demonstrate the use of a parabolic DM in a coronagraph instrument as well an integral field spectrograph (IFS). This versatile testbed is designed to test different DM architectures, various low-order wavefront schemes, and a lenslet based IFS. This provides us with a basis for comparison with different DM configurations – 1) flat DM, 2) parabolic DMs, and 3) a flat DM and parabolic DMs. In this communication, we will discuss the testbed design and updates, parabolic DM characterization, Gen 2 requirement definitions, and different tests planned for the testbed.

Hari Subedi↗

Low Threshold Voltages Electrochemically Drive Gold Migration in Halide Perovskite Devices

The constituent ions of halide perovskite materials are mobile in the solid state and known to participate in reduction/oxidation reactions. Yet few parameters related to electrochemical processes occurring within devices have been carefully determined. Here, we characterize such reactions in model MAPbI3 perovskite devices, and we quantify threshold voltages for key reactions. Gold is oxidized and mobilized under nitrogen, in the dark, at the MAPbI3/Au interface at 0.8 V. When this interface is buffered with the organic hole transport material (HTM), 2,2',7,7'-tetrakis(N,N-di-p-methoxyphenylamino)-9,9'-spirobifluorene, MAPbI3 begins to degrade at 1.2 V; degradation liberates ions that subsequently enable Au migration. Thresholds are insensitive to MAPbI3 thickness or choice of organic HTM or oxide cathode, which suggests that these reactions are driven electrochemically; the electric field across the device is less important. These results have profound implications for understanding in operando degradation pathways of optoelectronic perovskite devices that are varied in terms of interface structures, active material compositions, and ranges of external stressors.

42 ENGINEERING↗

Characterization and application of a high-resolution microfluidic device in atmospheric ice nucleation research and integrated science teaching

Ambient ice-nucleating particles (INPs) represent an important subset of aerosol particles that facilitate heterogeneous formation of ice crystals in the atmosphere, which can impact Earth system and energy. In this work, we developed an affordable high-resolution platform to replicate atmospheric immersion freezing through the unique capabilities of microfluidics to measure INP concentration of known ice nucleation active materials, as well as high-latitude soil samples. The new instrument produced comparable and extended freezing efficiency data for a multitude of samples over the temperature range of -5 to -35 °C as compared to an existing freezing assay within known uncertainties. Moreover, the new assay was integrated into science teaching at a primarily undergraduate and Hispanic-serving institute, contributing to fostering a deeper understanding of ice nucleation processes among college students, instilling their enthusiasm for science, and addressing the critical need for a well-informed citizenry. Student research assistants were involved in both research and pedagogical development processes. Three students from our team visited the Pacific Northwest National Laboratory to help characterize physicochemical properties of our test samples and to test modeling of atmospheric ice nucleation using a box model as well as a global climate model (E3SM) for the regional-scale conditions over the North Slope of Alaska (NSA) and Southern Great Plains (SGP). We also assessed student learning experience via hands-on training, research processes, and development of educational materials. On pre- and post-participation surveys and in exit interviews, students reported personal growth as advancements in breadth of experience, research-related skill sets, and regarding their educational and career goals. They also affirmed that the methods enacted incorporated the NASA Minority University Research and Education Program (MUREP) STEM Engagement Best Practices.

58 GEOSCIENCES↗

Characterization and Evaluation of a Mass Efficient Heat Storage Device.

The heat sponge is a device for mass-efficient storage of heat. It was developed to be incorporated in the substructure of a reentry or hypersonic vehicle to reduce thermal protection system requirements. The heat sponge consists of a liquid-vapor mixture contained within a number of miniature pressure vessels that can be embedded within a variety of different types of structures. As temperature is increased, pressure in the miniature pressure vessels also increases so that heat absorbed through vaporization of the liquid is spread over a relatively large temperature range. Using water as a working fluid, the heat storage capacity of the liquid-vapor mixture is many times higher than that of typical structural materials and is well above that of common phase change materials over the temperature range of 660oR to 1160oR. Prototype heat sponges were fabricated and characterized. These heat sponges consisted of 1.0 inch diameter hollow stainless steel spheres with a wall thickness of 0.020 inches which had varying percentages of their interior volumes filled with water. An apparatus to measure the heat stored in these prototype heat sponges was designed, fabricated, and verified. The heat storage capacity calculated from measured temperature histories is compared to numerical predictions.

Splinter, Scott C.↗

Hardness Assurance Techniques for New Generation COTS Devices

Hardness Assurance (HA) techniques and total dose radiation characterization data for new generation linear and COTS devices from various manufacturers are presented. A bipolar op amp showed significant degradation at HDR, not at low dose rate environment. New generation low-power op amps showed more degradation at low voltage applications. HA test techniques for COTS devices are presented in this paper.

New Millenium advanced technologies miniature spac↗

Fabrication and Performance of Large Format Transition Edge Sensor Microcalorimeter Arrays

We have produced a variety of superconducting transition edge sensor array designs for microcalorimetric detection of x-rays. Designs include kilopixel scale arrays of relatively small sensors (~75 micron pitch) atop a thick metal heatsinking layer as well as arrays of membrane-isolated devices on 250 micron pitch and smaller arrays of devices up to 600 micron pitch. We discuss the fabrication techniques used for each type of array focusing on unique aspects where processes vary to achieve the particular designs and required device parameters. For example, we evaluate various material combinations in the production of the thick metal heatsinking, including superconducting and normal metal adhesion layers. We also evaluate the impact of added heatsinking on the membrane isolated devices as it relates to basic device parameters. Arrays can be characterized with a time division SQUID multiplexer such that greater than 10 devices from an array can be measured in the same cooldown. Device parameters can be measured simultaneously so that environmental events such as thermal drifts or changes in magnetic fields can be controlled. For some designs, we will evaluate the uniformity of parameters impacting the intrinsic performance of the microcalorimeters under bias in these arrays and assess the level of thermal crosstalk.

Chervenak, James A.↗

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range avalanche photodiodes (APD's) are the best choice for higher signal-to-noise ratio, where there are many water vapor absorption lines. In this study, characterization experiments were performed to evaluate a group of silicon-based APD's. The APD's have different structures representative of different manufacturers. The experiments include setups to calibrate these devices, as well as characterization of the effects of voltage bias and temperature on the responsivity, surface scans, noise measurements, and frequency response measurements. For each experiment, the setup, procedure, data analysis, and results are given and discussed. This research was done to choose a suitable APD detector for the development of an advanced atmospheric water vapor differential absorption lidar detection system operating either at 720, 820, or 940 nm. The results point out the benefits of using the super low ionization ratio (SLIK) structure APD for its lower noise-equivalent power, which was found to be on the order of 2 to 4 fW/Hz(sup (1/2)), with an appropriate optical system and electronics. The water vapor detection systems signal-to-noise ratio will increase by a factor of 10.

Refaat, Tamer F.↗

Experimental Verification of the Parabolic Deformable Mirror for the ExoSpec Project

For the Habitable Worlds Observatory (HWO), it is essential to broaden the controllable wavelength bandwidth for high-contrast imaging and spectroscopy to increase the exoEarth yield and characterization. The Parabolic Deformable Mirrors (PDM) subpackage, under the NASA Headquarters-directed Exoplanet Spectroscopy (ExoSpec) Work Package, is specifically tailored to do so. We have successfully procured a first-generation (Gen 1) PDM device and completed in-depth characterization of the device. This robust evaluation has become instrumental in informing subsequent stages of development, particularly in shaping the design and specifying requirements for the next generation, Gen 2, PDM device. We have built a testbed in an environmentally controlled cleanroom to experimentally demonstrate the use of a PDM in a coronagraph instrument with an integral field spectrograph (IFS). This versatile testbed is designed to test different DM architectures, low-order wavefront sensing schemes, and a lenslet-based IFS. This provides us with a basis for comparison with different DM configurations: 1) flat DM, 2) PDMs, and 3) a flat DM and PDMs. In this communication, we will discuss the testbed design and updates, PDM characterization, and Gen 2 requirement definitions.

Hari B. Subedi↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low background IR detector and detector array evaluations

A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

Goebel, J. H.↗

Nonlinear optical thin films

A focused approach to development and evaluation of organic polymer films for use in optoelectronics is presented. The issues and challenges that are addressed include: (1) material synthesis, purification, and the tailoring of the material properties; (2) deposition of uniform thin films by a variety of methods; (3) characterization of material physical properties (thermal, electrical, optical, and electro-optical); and (4) device fabrication and testing. Photonic materials, devices, and systems were identified as critical technology areas by the Department of Commerce and the Department of Defense. This approach offers strong integration of basic material issues through engineering applications by the development of materials that can be exploited as the active unit in a variety of polymeric thin film devices. Improved materials were developed with unprecedented purity and stability. The absorptive properties can be tailored and controlled to provide significant improvement in propagation losses and nonlinear performance. Furthermore, the materials were incorporated into polymers that are highly compatible with fabrication and patterning processes for integrated optical devices and circuits. By simultaneously addressing the issues of materials development and characterization, keeping device design and fabrication in mind, many obstacles were overcome for implementation of these polymeric materials and devices into systems. We intend to considerably improve the upper use temperature, poling stability, and compatibility with silicon based devices. The principal device application that was targeted is a linear electro-optic modulation etalon. Organic polymers need to be properly designed and coupled with existing integrated circuit technology to create new photonic devices for optical communication, image processing, other laser applications such as harmonic generation, and eventually optical computing. The progression from microscopic sample to a suitable film-forming material in a working device is a complex, multifaceted endeavor. It requires close attention to maintaining the optical properties of the electro-optic active portion of the polymer while manipulating the polymer structure to obtain the desired secondary polymer properties.

Leslie, Thomas M.↗

Characterization of Amplification Properties of the Superconducting-Ferromagnetic Transistor

Here we report on the measurement results of the superconducting-ferromagnetic transistors (SFTs). The devices were made at Northwestern University and Hypres (SeeQC), Inc. (Nevirkovets et al., 2014; 2015). SFT is a multiterminal device with the SIS'FIFS (or SFIFS'IS) structure (where S, I, and F denote a superconductor, an insulator, and a ferromagnetic material, respectively) exploiting intense quasiparticle injection in order to modify the nonlinear I-V curve of a superconducting tunnel junction. SFT is capable of providing voltage, current, and power amplification while having good input/output isolation. We characterized the devices using different measurement techniques. We measured S parameters of the single- and double-acceptor devices at frequencies up to 5 MHz. Importantly, we confirmed that the isolation between the input and output of the device is quite good. However, the techniques typically employed to characterize semiconductor devices do not allow for revealing the full potential of our low-resistive SFT devices, especially those having two acceptors. In the latter case, we also tested the devices using the battery-powered current sources with floating grounds. Analyzing double-acceptor I-V curves recorded at different levels of injection currents, for an optimal load, we deduced a small-signal voltage gain of 33 and a power gain of 2.4. We suggest that further improvement of the SFT device parameters is possible in optimized devices, so that the device potentially may serve as a preamplifier for readout of output signals of cryogenic detectors and be useful as an element of other superconductor-based circuits. In addition, we used scanning transmission electron microscopy to identify some problems in the fabrication of the devices without any planarization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Filtering Water by Use of Ultrasonically Vibrated Nanotubes

Devices that could be characterized as acoustically driven molecular sieves have been proposed for filtering water to remove all biological contaminants and all molecules larger than water molecules. Originally intended for purifying wastewater for reuse aboard spacecraft, these devices could also be attractive for use on Earth in numerous settings in which there are requirements to obtain potable, medical-grade, or otherwise pure water from contaminated water supplies. These devices could also serve as efficient means of removing some or all water from chemical products . for example, they might be useful as adjuncts or substitutes for stills in the removal of water from alcohols and alcoholic beverages. These devices may be constructed using various materials, such as ceramics, metallics, or polymers, depending on end-use requirements. A representative device of this type (see figure) would include a polymeric disk, about 1 mm in diameter and between 1 and 40 microns thick, within which would be embedded single-wall carbon nanotubes aligned along the thickness axis. The polymeric disk would be part of a unitary polymeric ring assembly. An acoustic transducer in the form of a piezoelectric-film-and-electrode subassembly - typically 9 microns thick and made of poly(vinylidene fluoride) coated with copper 150 nm thick -. would be affixed to the outside of the outer polymeric ring by means of an electrically nonconductive epoxy. The nanotubes would be chosen to have diameters between about 8 and about 13.5 A because water molecules could fit into the nanotubes, but larger molecules could not. Water to be purified would be placed in contact with one face (typically, the upper face) of the filter disk. The surface tension of water is low enough that water molecules should enter and travel along the nanotubes, and computational simulations of molecular dynamics and experimental measurements have shown that the water molecules inside the nanotubes in this size range can be expected to become aligned into helical columns that exhibit properties of both hexagonal ice crystals and liquid water

Gavalas, Lillian Susan↗

Characterization of Microwave Loss Using Multimode Superconducting Resonators

Measuring the losses arising from different materials and interfaces is crucial to improving the coherence of superconducting quantum circuits. Although this has been of interest for a long time, current studies can either only provide bounds to those losses, or require several devices for a complete characterization. In this work, we introduce a method to measure the microwave losses of materials and interfaces with a single multi-mode superconducting resonator. We demonstrate a formalism for analyzing the loss sensitivity of multi-mode systems and discuss the design strategies of multi-mode resonators for material loss studies. We present two types of multi-mode superconducting resonators for the study of bulk superconductors: the forky whispering-gallery-mode resonator (FWGMR) and the ellipsoidal cavity. We use these resonators to measure the surface dielectric, conductor, and seam losses of high-purity (5N5) aluminum and aluminum alloy (6061), as well as how they are affected by chemical etching, diamond turning, and thin-film coating. Here, we find that chemical etching and diamond turning reduce both the surface dielectric and conductive losses of high-purity aluminum, but provide no appreciable improvement to the seam. Coating the surfaces of diamond-turned aluminum alloys with e-beam evaporated or sputtered aluminum thinfilms significantly reduces all three losses under study. In addition, we study the effect of chemical etching on the surface of high-purity aluminum using transmission electron microscopy (TEM) and find that the chemical etching process creates a thinner and more uniform oxide layer, consistent with the observed improvement in the surface dielectric loss.

25 ENERGY STORAGE↗

Microgravity Disturbance Characterization of the Quench Module Insert (QMI) Phase Change Device (PCD)

The Materials Science Research Facility (MSRF) is a multi-user, multi-purpose facility for materials science research. One experiment within the MSRF will be the Quench Module Insert (QMI), a high-temperature furnace with unique capabilities for processing different classes of materials. The primary functions of the QMI furnace are to melt, directionally solidify, and quench metallic samples, providing data to aid in understanding the effects of the microgravity environment on the characteristics of these processed metals. The QMI houses sealed individual sample ampoules containing material to be processed. Quenching of the samples in the QMI furnace is accomplished by releasing low-melting-point metallic shoes into contact with the outside of the sample ampoule, dissipating heat and cooling the sample inside. The impact from this method of quench will induce sample vibrations which could be large enough to adversely affect sample quality. Utilizing breadboard hardware, the sample quench sequence, releasing the shoes, was conducted. Data was collected from accelerometers located on the breadboard sample cartridge, indicating the maximum acceleration achieved by the sample. The primary objective of the test described in this presentation was to determine the acceleration imparted on the sample by the shoe contact. From this information, the science community can better assess whether this method of quench will allow them to obtain the data they need.

Gattis, Christy↗

Characterization of 808-nm Quasi-CW Laser Diode Arrays

This viewgraph presentation reviews a study that aimed at a characterization of the Quasi-CW Laser Diode Arrays. NASA's requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. Performance and comprehensive characterization data of Quasi-CW, High-power, laser diode arrays is presented

Stephen, Mark↗