Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.↗

Electronic heterodyne moire deflectometry: A method for transient and three dimensional density fields measurements

Effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are investigated. The deferred deflectometry is used for measurements of nonsteady phase objects where it is difficult to complete the analysis of the field in real time. The sensitivity, accuracy and resolution of the system are calculated and it is shown that they are weakly affected by diffraction and by nonlinear recording. The feactures of the system are significantly improved compared with the conventional deferred intensity moire technique, and are comparable with the online heterodyne moire. The system was evaluated experimentally by deferred measurements of the refractive index gradients of a weak phase object consisting of a large KD*P crystal. This was done by photographing the phase object through a Ronchi grating and analyzing the tranparency with the electronic heterodyne readout system. The results are compared with the measurements performed on the same phase object with online heterodyne moire deflectometry and with heterodyne holographic interferometry methods. Some practical considerations for system improvement are discussed.

Stricker, Josef↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Soft X-ray spectroscopy of solar flares - An overview

An overview of the current status of high spectral resolution soft X-ray observations of solar flares is given. The review concentrates primarily on recent results and interpretations of results obtained from orbiting Bragg crystal spectrometers flow during the last solar maximum on the US DoD P78-1 spacecraft, the NASA SMM, and the ISAS Hinotori spacecraft. Results and several key issues regarding interpretation of the spectra are presented. Specifically, the dynamics of coronal flare plasmas as revealed by X-ray line profiles and wavelength shifts are discussed. Recent results concerning the theory of chromospheric evaporation are given. The temperature of coronal flare plasma is discussed within the context of a differential mission measure. Results concerning electron density measurements, nonequilibrium processes, and relative element abundances are also reviewed.

Doschek, G. A.↗

High resolution measurements of density structures in the Jovian plasma sheet

A recent effort to digitize the plasma density by using the low frequency cutoff of trapped continuum radiation in the vicinity of the Jovian plasma sheet has revealed the existence of sharply defined density structures in the plasma sheet. These structures typically have a plasma density which is relatively constant but of order 50 percent greater or less than in the surrounding plasma. At the boundaries of these structures, the transitions from low to high density occur on time scales of about ten seconds, which correspond to spatial dimensions on the order of a few ion Larmor radii. The structures themselves last for intervals from less than a minute to more than five minutes, corresponding to size scales from a fraction of a Jovian radius to more than a Jovian radius, depending of the velocity of the structure relative to the spacecraft. In view of the importance of near corotation plasma flows, these structures are likely to be limited in both the longitudinal and radial dimensions and, therefore, could represent flux tubes with greatly varying plasma content. These observations are presented as among the first to directly address the theoretically proposed interchange instability.

Ansher, J. A.↗

High resolution measurements of density structures in the Jovian plasma sheet

A recent effort to digitize the plasma density by using the low frequency cutoff of trapped continuum radiation in the vicinity of the Jovian plasma sheet has revealed the existence of sharply defined density structures in the plasma sheet. These structures typically have a plasma density which is relatively constant but of order 50 percent greater or less than in the surrounding plasma. At the boundaries of these structures, the transitions from low to high density occur on time scales of about ten seconds, which correspond to spatial dimensions on the order of a few ion Larmor radii. The structures themselves last for intervals from less than a minute to more than five minutes, corresponding to size scales from a fraction of a Jovian radius to more than a Jovian radius, depending on the velocity of the structure relative to the spacecraft. In view of the importance of near corotation plasma flows, these structures are likely to be limited in both the longitudinal and radial dimensions and, therefore, could represent flux tubes with greatly varying plasma content. These observations are presented as among the first to directly address the theoretically proposed interchange instability.

Ansher, J. A.↗

The nightside ionosphere of Venus under varying levels of solar EUV flux

Solar activity varied widely over the 14 year lifetime of the Pioneer Venus Orbiter (PVO), and these variations directly affected the properties of the nightside ionosphere. At solar maximum, when solar EUV was largest, the Venus ionosphere was found to extend to highest altitudes and nightward ion transport was the main source of the nightside ionosphere. At solar minimum, nightward ion transport was reduced, and electron precipitation was thought to be the main source. In this study, we have attempted a separation of spatial variations from temporal variations by examining the altitude profiles of the magnetic field, and electron density and temperature for three different solar EUV flux ranges. In the upper ionosphere and near-planet magnetotail (h greater than 1800 km), the solar EUV flux effects are significant. The electron density decreases about an order of magnitude from high to low EUV flux, while the electron temperature at least doubles. The magnetic field also increases 2 - 3 nT. In the lower ionosphere (200 - 600 km), lower EUV fluxes are associated with slightly reduced density, and higher temperature. These results are in accord with recent entry phase observations, where the electron density measured above the ionospheric density peak is lower than that observed at solar maximum during the early Pioneer Venus mission.

Ho, C. M.↗

The Nightside Ionosphere of Venus Under Varying Levels of Solar EUV Flux

Solar activity varied widely over the 14 year lifetime of the Pioneer Venus Orbiter, and these variations directly affected the properties of the nightside ionosphere. At solar maximum, when solar EUV was largest, the Venus ionosphere was found to extend to highest altitudes and nightward ion transport was the main source of the nightside ionosphere. At solar minimum, nightward ion transport was reduced, and electron precipitation was thought to be the main source. In this study, we have attempted a separation of spatial variations from temporal variations by examining the altitude profiles of the magnetic field, and electron density and temperature for three different solar EUV flux ranges. In the upper ionosphere and near-planet magnetotail (h greater than 1800 km), the solar EUV effects are significant. The electron density decreases about an order of magnitude from high to low EUV flux, while the electron temperature at least doubles. The magnetic field also increases 2 - 3 nT. In the lower ionosphere (200 - 600 km), lower EUV fluxes are associated with slightly reduced density, and higher temperature. These results are in accord with recent entry phase observations, where the electron density measured above the ionospheric density peak is lower than that observed at solar maximum during the early Pioneer Venus mission.

Ho, C. M.↗

Biophotonics and Bone Biology

One of the more serious side effects of extended space flight is an accelerated bone loss. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It is well known that bone remodeling responds to mechanical forces. We are developing two-photon microscopy techniques to study bone tissue and bone cell cultures to better understand the fundamental response mechanism in bone remodeling. Osteoblast and osteoclast cell cultures are being studied, and the goal is to use molecular biology techniques in conjunction with Fluorescence Lifetime Imaging Microscopy (FLIM) to study the physiology of in-vitro cell cultures in response to various stimuli, such as fluid flow induced shear stress and mechanical stress. We have constructed a two-photon fluorescence microscope for these studies, and are currently incorporating FLIM detection. Current progress will be reviewed. This work is supported by the NASA John Glenn Biomedical Engineering Consortium.

Zimmerli, Gregory↗

Biophotonics and Bone Biology

One of the more-serious side effects of extended space flight is an accelerated bone loss [Bioastronautics Critical Path Roadmap, http://research.hq.nasa.gov/code_u/bcpr/index.cfm]. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It shows that an extrapolation of the microgravity induced bone loss rates to longer time scales, such as a 2.5 year round-trip to Mars (6 months out at 0 g, 1.5 year stay on Mars at 0.38 g, 6 months back at 0 g), could severely compromise the skeletal system of such a person.

Zimmerli, Gregory↗

Environmental Testing of the NEXT PM1R Ion Engine

The NEXT propulsion system is an advanced ion propulsion system presently under development that is oriented towards robotic exploration of the solar system using solar electric power. The subsystem includes an ion engine, power processing unit, feed system components, and thruster gimbal. The Prototype Model engine PM1 was subjected to qualification-level environmental testing in 2006 to demonstrate compatibility with environments representative of anticipated mission requirements. Although the testing was largely successful, several issues were identified including the fragmentation of potting cement on the discharge and neutralizer cathode heater terminations during vibration which led to abbreviated thermal testing, and generation of particulate contamination from manufacturing processes and engine materials. The engine was reworked to address most of these findings, renamed PM1R, and the environmental test sequence was repeated. Thruster functional testing was performed before and after the vibration and thermal-vacuum tests. Random vibration testing, conducted with the thruster mated to the breadboard gimbal, was executed at 10.0 Grms for 2 min in each of three axes. Thermal-vacuum testing included three thermal cycles from 120 to 215 C with hot engine re-starts. Thruster performance was nominal throughout the test program, with minor variations in a few engine operating parameters likely caused by facility effects. There were no significant changes in engine performance as characterized by engine operating parameters, ion optics performance measurements, and beam current density measurements, indicating no significant changes to the hardware as a result of the environmental testing. The NEXT PM1R engine and the breadboard gimbal were found to be well-designed against environmental requirements based on the results reported herein. The redesigned cathode heater terminations successfully survived the vibration environments. Based on the results of this test program and confidence in the engineering solutions available for the remaining findings of the first test program, specifically the particulate contamination, the hardware environmental qualification program can proceed with confidence

Snyder, John S.↗

High Speed and High Spatial Density Parameter Measurement Using Fiber Optic Sensing Technology

The present invention is an improved fiber optic sensing system (FOSS) having the ability to provide both high spatial resolution and high frequency strain measurements. The inventive hybrid FOSS fiber combines sensors from high acquisition speed and low spatial resolution Wavelength-Division Multiplexing (WDM) systems and from low acquisition speed and high spatial resolution Optical Frequency Domain Reflection (OFDR) systems. Two unique light sources utilizing different wavelengths are coupled with the hybrid FOSS fiber to generate reflected data from both the WDM sensors and OFDR sensors operating on a single fiber optic cable without incurring interference from one another. The two data sets are then de-multiplexed for analysis, optionally with conventionally-available WDM and OFDR system analyzers.

Parker, Allen R. Jr.↗

Thermosphere Global Time Response to Geomagnetic Storms Caused by Coronal Mass Ejections

We investigate, for the first time with a spatial superposed epoch analysis study, the thermosphere global time response to 159 geomagnetic storms caused by coronal mass ejections (CMEs) observed in the solar wind at Earth's orbit during the period of September 2001 to September 2011. The thermosphere neutral mass density is obtained from the CHAMP (CHAllenge Mini-Satellite Payload) and GRACE (Gravity Recovery Climate Experiment) spacecraft. All density measurements are intercalibrated against densities computed by the Jacchia-Bowman 2008 empirical model under the regime of very low geomagnetic activity. We explore both the effects of the pre-CME shock impact on the thermosphere and of the storm main phase onset by taking their times of occurrence as zero epoch times (CME impact and interplanetary magnetic field Bz southward turning) for each storm. We find that the shock impact produces quick and transient responses at the two high-latitude regions with minimal propagation toward lower latitudes. In both cases, thermosphere is heated in very high latitude regions within several minutes. The Bz southward turning of the storm onset has a fast heating manifestation at the two high-latitude regions, and it takes approximately 3 h for that heating to propagate down to equatorial latitudes and to globalize in the thermosphere. This heating propagation is presumably accomplished, at least in part, with traveling atmospheric disturbances and complex meridional wind structures. Current models use longer lag times in computing thermosphere density dynamics during storms. Our results suggest that the thermosphere response time scales are shorter and should be accordingly adjusted in thermospheric empirical models.

mass ejections↗

Analysis of the density field around a supersonic conical projectile using quantitative schlieren

Quantitative schlieren imaging is a flow measurement technique that is capable of measuring density fields throughout refractive flowfields. The technique was applied here to measure the density field surrounding supersonic conical projectiles in free flight. Shock waves attached to a supersonic conical projectile offer a simple geometry with the well-established Taylor–Maccoll analytical flow solution to which these experimental measurements were compared. The schlieren images recorded a projection of the index of refraction field surrounding the 10° half-angle cones which was converted to density first through an Abel inversion and then the Gladstone–Dale law. Three Abel inversion methods—two-point, three-point, and arbitrary ray axisymmetric projection (ARAP)—were applied to deconvolute the three-dimensional flow within the constrained axisymmetric flow field. The resulting reconstructed density profiles were compared to the Taylor–Maccoll solution, parameterized by cone geometry and Mach number. The experimental density fields demonstrated strong agreement with the theoretical profiles. Experimental consistency was confirmed across various projectile speeds, demonstrating quantitative schlieren’s capability to accurately reconstruct the density of the flow field, even within the resolution constraints imposed by high-speed imaging. In conclusion, an assessment of experimental uncertainties in the density reconstruction was performed.

Abel Inversion↗

Oak Ridge National Laboratory Official TM Cover: Development and Qualification of Tungsten Reference Materials for LA-ICP-MS

Reference materials have been developed to provide areal density measurements of tungsten that is deposited on graphite when using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Several reference materials of varying areal densities have been produced using a magnetron sputtering, thin film deposition technique. With multiple reference materials that have varying areal densities, a calibration curve has been developed for translating the detector response of an ICP-MS into a quantitative measurement. These results provide the opportunity to make calibrated comparisons across graphite samples that were exposed to tungsten transport experiments for nuclear fusion research. In addition, these methods may be applied to provide individual areal density measurements for the five unique isotopes of tungsten. It is found that areal density measurements via LA-ICP-MS agree with characterization for the same samples when using the more traditional Rutherford backscattering ion beam technique. Qualification of these reference materials was completed using ion beam laboratories at the University of Tennessee, Knoxville and Massachusetts Institute of Technology, and Sandia National Laboratory.

36 MATERIALS SCIENCE↗