Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Theoretical and experimental demonstration of the relationship between microstructure and the DC-bias-superposition characteristic of ferrite materials

Highlights: • We proved how to improve DC-bias-superposition characteristic of ferrites. • We confirmed the correctness of the theoretical result by experiment. • This research provides a good guide for developing more stable ferrites. - Abstract: DC-bias superposition is important for ferrite materials used in power components. However, methods of improving this characteristic of ferrites have not yet been clearly established. In this study, we theoretically prove that a ferrite with high intrinsic permeability composition and thick grain-boundary microstructure provides better DC-bias superposition than a ferrite with low intrinsic-permeability composition and thin grain-boundary microstructure given the same permeability. We then validate the theoretical results by experiments. Results can guide the development of ferrite materials while considering permeability and stability for the improvement of DC-bias superposition.

36 MATERIALS SCIENCE↗

A physics‐informed learning technique for fault location of DC microgrids using traveling waves

Abstract Fast and accurate fault location in DC power systems is of particular importance to ensure their reliable operation. One of the approaches for implementing a fast‐tripping protection scheme is to use Traveling waves (TW) initiated by a fault scenario. This paper proposes a physics‐informed machine learning approach that utilizes TWs for fault location in DC microgrids. TWs are extracted by the so‐called multiresolution analysis which identifies the TW's wavelet coefficients for multiple frequency ranges. This paper deploys Parseval's theorem to find the energy of wavelet coefficients as a quantitative metric for describing TWs. The hypothesis of this paper is that once the Parseval energy curves for a specific cable are extracted, they can be utilized to locate faults along with that cable regardless of the DC system in which the cable is deployed. The fault location algorithm uses Parseval energy curves to train a Gaussian Process (GP) estimator. With the Parseval energy values of measured current at the protection device location, the GP estimator is able to estimate fault locations with high accuracy. The effectiveness of the proposed algorithm is verified by simulating a DC microgrid system in PSCAD/EMTDC.

Paruthiyil, Sajay Krishnan↗

Evolution of an electron energy distribution function in a weak dc magnetic field in solenoidal inductive plasma

We investigated the evolution of the electron energy distribution function (EEDF) in a solenoidal inductively coupled plasma surrounded by an axial dc magnetic field. The increase in the dc magnetic field caused the EEDF to evolve from a bi-Maxwellian to a Maxwellian distribution. At the discharge center, the number of low energy electrons was significantly reduced while the high energy electron population showed little change when a weak dc magnetic field was present. However, at the discharge radial boundary, the high energy electron population decreased significantly with the magnetic field while the change in low energy population was not prominent compared to the discharge boundary. These changes in EEDFs at the boundary and center of the discharge are due to the radial confinement and the restriction of radial transport of electrons by dc magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High energy electron fluxes in dc-augmented capacitively coupled plasmas. II. Effects on twisting in high aspect ratio etching of dielectrics

In high aspect ratio (HAR) plasma etching of holes and trenches in dielectrics, sporadic twisting is often observed. Twisting is the randomly occurring divergence of a hole or trench from the vertical. Many causes have been proposed for twisting, one of which is stochastic charging. As feature sizes shrink, the fluxes of plasma particles, and ions in particular, into the feature become statistical. Randomly deposited charge by ions on the inside of a feature may be sufficient to produce lateral electric fields which divert incoming ions and initiate nonvertical etching or twisting. This is particularly problematic when etching with fluorocarbon gas mixtures where deposition of polymer in the feature may trap charge. dc-augmented capacitively coupled plasmas (dc-CCPs) have been investigated as a remedy for twisting. In these devices, high energy electron (HEE) beams having narrow angular spreads can be generated. HEEs incident onto the wafer which penetrate into HAR features can neutralize the positive charge and so reduce the incidence of twisting. In this paper, we report on results from a computational investigation of plasma etching of SiO{sub 2} in a dc-CCP using Ar/C{sub 4}F{sub 8}/O{sub 2} gas mixtures. We found that HEE beams incident onto the wafer are capable of penetrating into features and partially neutralizing positive charge buildup due to sporadic ion charging, thereby reducing the incidence of twisting. Increasing the rf bias power increases the HEE beam energy and flux with some indication of improvement of twisting, but there are also changes in the ion energy and fluxes, so this is not an unambiguous improvement. Increasing the dc bias voltage while keeping the rf bias voltage constant increases the maximum energy of the HEE and its flux while the ion characteristics remain nearly constant. For these conditions, the occurrence of twisting decreases with increasing HEE energy and flux.

36 MATERIALS SCIENCE↗

A highly stable DC power supply for precision magnetic field measurements and other purposes

A homogeneous magnetic field is essential for the {sup 3}He neutron spin filter used to polarize neutron beams and analyze neutron spins in neutron scattering. The required spatial uniformity of the magnetic field is on the order of 10{sup -4}/cm or less. To measure such uniformity, one needs a DC current source with a current stability much better than 10{sup -4}. However, laboratory DC power supplies, which are commonly used in many {sup 3}He neutron spin filters, do not have such stabilities. To attain a highly stable current with a common laboratory DC power supply for every {sup 3}He neutron spin filter, a simple feedback circuit has been developed to keep the output current stable up to 10{sup -6}. Such a highly stable current or voltage from a common laboratory DC power supply can also be used for various other research applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introduction of DC line structures into a superconducting microwave 3D cavity

We report a technique that can noninvasively add multiple DC wires into a 3D superconducting microwave cavity for electronic devices that require DC electrical terminals. We studied the influence of our DC lines on the cavity performance systematically. We found that the quality factor of the cavity is reduced if any of the components of the electrical wires cross the cavity equipotential planes. Using this technique, we were able to incorporate a quantum dot (QD) device into a 3D cavity. We then controlled and measured the QD transport signal using the DC lines. We have also studied the heating effects of the QD by the microwave photons in the cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DC electric field generation and distribution in magnetized plasmas

Very large DC and AC electric fields cannot be sustained between conducting electrodes because of volume gas breakdown and/or surface field emission. However, very large potential fields are now routinely generated in plasma structures, such as laser generated wake in unmagnetized plasmas. In magnetized plasmas, large DC fields can also be sustained and controlled perpendicular to the magnetic field, but the metallic end plates limiting the plasma, terminating the magnetic field lines, and usually providing the voltage drop feed between the field lines impose severe restrictions on the maximum field. However, it is shown that very large radial DC voltage drops can be sustained by injecting waves of predetermined frequencies and wave vectors, traveling along the azimuthal direction of an axially magnetized plasma cylinder, or by injecting fast neutral particles beams along this azimuthal direction. The large conductivity along the magnetic field lines and the small conductivity between the field lines then distribute this voltage drop. Furthermore, the global power balance and control parameters of wave and beam generated large DC electric fields in magnetized plasmas are identified, described, and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗

Decoherence and dephasing errors caused by the dc Stark effect in rapid ion transport

We investigate the error due to the dc Stark effect for quantum information processing for trapped ion quantum computers using the scalable architecture proposed in D. Wineland et al. [J. Res. Natl. Inst. Stand. Technol. 103, 259 (1998)] and D. Kielpinski et al. [Nature (London) 417, 709 (2002)]. As the operational speed increases, dephasing and decoherence due to the dc Stark effect become prominent as a large electric field is applied for rapidly transporting ions. We estimate the relative significance of the decoherence and dephasing effects and find that the latter is dominant. We find that the minimum possible dephasing is quadratic in the length of a trap and an inverse cubic in the operational time scale. From these relations, we obtain the operational speed range at which the shifts, caused by the dc Stark effect, are no longer negligible, no matter on which trajectory the ion is transported. Without phase correction, the shortest time a qubit can be transferred across a 100-micrometer-long trap, without excessive error, is about 10 ns for a {sup 40}Ca{sup +} ion and 50 ps for a {sup 9}Be{sup +} ion. In practice, the accumulated error is difficult to track and to calculate; thus, our paper gives an estimate for the range of the speed limit imposed by the dc Stark effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Common-mode noise reduction with impedance balancing in DC-fed motor drives

Unlike conventional passive or active filters, an impedance balancing circuit reduces the common-mode (CM) electromagnetic interference (EMI) noise by establishing an impedance balancing bridge. The EMI noise can be significantly reduced when the impedance bridge is designed to be well balanced. This paper investigates impedance balancing circuits in Dc-fed motor drive systems where both DC input and AC output need to meet EMI standards and thus EMI filters are needed for both sides. An impedance balancing circuit is proposed to reduce both DC and AC side CM noise. Two auxiliary branches are added to the conventional passive filters to establish an impedance bridge and reduce CM noise. The design criteria are presented, and the impact of the proposed impedance balancing circuit on both sides CM noise are investigated. It shows that the proposed impedance balancing circuit can reduce DC side and AC side CM noise based on different mechanisms. The CM noise reduction performance of the proposed method does not depend on the motor and cable models. Experiment results are presented to demonstrate the feasibility and effectiveness of the proposed method.

Chen, Ruirui↗

Analytical Analysis of Ac and Dc Side Harmonics of Three-level Active Neutral Point Clamped Inverter with Space Vector Modulation

This paper presents a comprehensive analytical analysis of the ac and dc side harmonics of the three-level active neutral point clamped (ANPC) inverter with space vector modulation (SVM) scheme. An analytical model to calculate the harmonics of a three-level converter with SVM is developed. The ac side output voltage harmonics and dc side current harmonics characteristics are calculated and analyzed. With the developed models, the impact of interleaving on both sides harmonics are studied which considers the modulation index, interleaving angle, and power factor. The analysis provides guideline for interleaving angle optimization to reduce the ac side power filter and dc side dc-link capacitor. The relationship between electromagnetic interference (EMI) filter corner frequency and switching frequency is also analytically derived which provides guideline for switching frequency and EMI filter design optimization. Two paralleled three-level ANPC inverters are constructed and experimental results are presented to verify the analytical analysis.

Chen, Ruirui↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗

Measured and Calculated DC Arc-Flash Incident Energy in a Large-Scale Photovoltaic Plant

There is a growing amount of high-power dc equipment being deployed, including solar photovoltaic (PV) plants, but very few studies have measured and quantified dc arc-flash risks. Most dc arc-flash literature is based on the theory and, when their theoretical calculations are applied to real-world conditions, can significantly deviate from actual measured values. For PV, the nonlinearity of the power source (i.e., PV modules) creates an additional level of uncertainty for theoretical approaches. This paper quantifies the thermal hazards from arc flash in a real-world 1000-kWdc PV plant by measuring arc current, arc voltage, and incident energy (IE) and then compares results against existing IE models. The study reveals that none of the available models adequately represent real-world hazards. It is also found that a PV source acts as a sustainable constant-current source during an arcflash event. As a result, this paper is an important first step toward developing an improved model that more accurately assesses dc arc-flash risk in a PV system.

14 SOLAR ENERGY↗

Solar/Photovoltaic DC Systems: Information for Electrical Workers and Firefighters

Solar photovoltaic (PV) systems are common and continue to gain popularity. This article helps electrical workers and firefighters understand basic operating principles and hazards of PV dc arrays. The effects of solar radiation and temperature on power output are discussed including; PV-module testing standards; methods for calculating the number of modules in a PV string; some National Electrical Code (NEC) guidelines that are aimed toward improving array safety; dc-array commissioning, periodic maintenance, and testing; arc-flash-hazard potential ways firefighters can work safely around PV arrays; potential risks posed by moonlight and other light sources; some unique dc-system hazards. We also present statistics on PV dc-array electrical incidents and injuries.

14 SOLAR ENERGY↗

A Multilevel DC to Three-phase AC Architecture for Photovoltaic Power Plants

This study presents a photovoltaic (PV) inverter architecture composed of stackable dc to three-phase ac converter blocks. Several such blocks, each containing a converter power stage and controls, are connected in series on their ac sides to obtain transformerless medium-voltage ac interfaces for PV power plants. The series-connected structure is made possible by a quadruple active bridge dc-dc converter that provides isolation between the PV input and each of the three ac-side phases within each block. Furthermore, since incoming PV power is transferred as constant balanced three-phase ac power, instantaneous inputoutput power balance bypasses the need for bulk energy storage. To streamline implementation and maximize system scalability and resilience, decentralized block-level controllers accomplish dc-link voltage regulation, maximum power point tracking, and ac-side power sharing without centralized means. The proposed architecture is validated by simulations of a PV string to mediumvoltage ac system consisting of six blocks and on a proof-of-concept hardware prototype that consists of three cascaded converter blocks.

14 SOLAR ENERGY↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation

Abstract Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high-flow-rate [50 cubic feet per minute (CFM) and higher] 12-VDC (where VDC refers to voltage direct current) fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower-flow-rate (35 CFM) 120-VAC (where VAC refers to voltage alternating current) fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsets for these black-and-white pyranometers are always small, usually no more than 1 W m−2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated and ventilated pyranometers. An important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.

14 SOLAR ENERGY↗

Anisotropic Thermal Behavior of Silicone Polymer, DC 745

In material applications, it is important to understand how polymeric materials behave in the various environments they may encounter. One factor governing polymer behavior is processing history. Differences in fabrication will result in parts with varied or even unintended properties. In this work, the thermal expansion behavior of silicone DC 745 is studied. Thermomechanical analysis (TMA) is used to determine changes in sample dimension resulting from changes in temperature. This technique can measure thermal events such as the linear coefficient of thermal expansion (CTE), melting, glass transitions, cure shrinkage, and internal relaxations. Using a thermomechanical analyzer (Q400 TMA), it is determined that DC 745 expands anisotropically when heated. This means that the material has a different CTE depending upon which direction is being measured. In this study, TMA experiments were designed in order to confirm anisotropic thermal behavior in multiple DC 745 samples of various ages and lots. TMA parameters such as temperature ramp rate, preload force, and temperature range were optimized in order to ensure the most accurate and useful data. A better understanding of the thermal expansion of DC 745 will allow for more accurate modeling of systems using this material.

36 MATERIALS SCIENCE↗