Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Dynamic Formation of a Transient Jet from Arched Magnetized Laboratory Plasma

Abstract A laboratory plasma experiment was built to explore the eruptive behavior of arched magnetized plasmas with dimensionless parameters relevant to the Sun’s photosphere ( β ≈ 10 −3 , Lundquist number ≈10 4 , plasma radius/ion gyroradius ≈20, ion–neutral collision frequency ≫ion cyclotron frequency). Dynamic formation of a transient plasma jet was observed in the presence of the strapping magnetic field. The eruption leading to the jet is unintuitive because the arched plasma is both kink- and torus-stable. The jet structure erupts within a few Alfvén transit times from the formation of the arched plasma. Extensive measurements of plasma temperature, density, magnetic field, and flows are presented. In its early stages, the jet plasma flows away from the arch with supersonic speeds (Mach 1.5). This high-speed flow persists up to the resistive diffusion time in the arched plasma and is driven by large gradients in the magnetic and thermal pressures near the birthplace of jets. There are two distinct electric current channels within the jet, one consisting of outgoing electrons and another composed of electrons returning to the anode footpoint. Significant current density around the jet is a consequence of the diamagnetic current produced by a large thermal pressure gradient in the jet. Ion–neutral charge-exchange collisions provide an efficient mechanism to produce the cross-field current and control the dynamics of the complex current channels of the jet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zener diode controls switching of large direct currents

High-current zener diode is connected in series with the positive input terminal of a dc supply to block the flow of direct current until a high-frequency control signal is applied across the zener diode. This circuit controls the switching of large dc signals.

Source record↗

Optimal redesign study of the harm wing

The purpose of this project was to investigate the use of optimization techniques to improve the flutter margins of the HARM AGM-88A wing. The missile has four cruciform wings, located near mid-fuselage, that are actuated in pairs symmetrically and antisymmetrically to provide pitch, yaw, and roll control. The wings have a solid stainless steel forward section and a stainless steel crushed-honeycomb aft section. The wing restraint stiffness is dependent upon wing pitch amplitude and varies from a low value near neutral pitch attitude to a much higher value at off-neutral pitch attitudes, where aerodynamic loads lock out any free play in the control system. The most critical condition for flutter is the low-stiffness condition in which the wings are moved symmetrically. Although a tendency toward limit-cycle flutter is controlled in the current design by controller logic, wing redesign to improve this situation is attractive because it can be accomplished as a retrofit. In view of the exploratory nature of the study, it was decided to apply the optimization to a wing-only model, validated by comparison with results obtained by Texas Instruments (TI). Any wing designs that looked promising were to be evaluated at TI with more complicated models, including body modes. The optimization work was performed by McIntosh Structural Dynamics, Inc. (MSD) under a contract from TI.

Mcintosh, S. C., Jr.↗

Real-time cartesian force feedback control of a teleoperated robot

Active cartesian force control of a teleoperated robot is investigated. An economical microcomputer based control method was tested. Limitations are discussed and methods of performance improvement suggested. To demonstrate the performance of this technique, a preliminary test was performed with success. A general purpose bilateral force reflecting hand controller is currently being constructed based on this control method.

Campbell, Perry↗

A single-axis testbed for slewing control experiments

A simple single-axis testbed is described, and initial experimental results are presented to illustrate collocated and noncollocated control for this structure. The testbed is made up of a pair of single-axis flexible beams attached to a DC servo motor. An optical encoder and strain gauges provide hub and beam position information, respectively. The system is driven by an IBM PC system; with a motor controller, a programmable digital filter processes position error information through user-selected gains and pole-zero configurations. A 25-kHz data acquisition system provides the necessary interface between processor and motor. The control approaches currently being investigated include collocated PD control and noncollocated phase compensation.

Hamilton, Jonathan↗

The 10 kW power electronics for hydrogen arcjets

A combination of emerging mission considerations such as 'launch on schedule', resource limitations, and the development of higher power spacecraft busses has resulted in renewed interest in high power hydrogen arcjet systems with specific impulses greater than 1000 s for Earth-space orbit transfer and maneuver applications. Solar electric propulsion systems with about 10 kW of power appear to offer payload benefits at acceptable trip times. This work outlines the design and development of 10 kW hydrogen arcjet power electronics and results of arcjet integration testing. The power electronics incorporated a full bridge switching topology similar to that employed in state of the art 5 kW power electronics, and the output filter included an output current averaging inductor with an integral pulse generation winding for arcjet ignition. Phase shifted, pulse width modulation with current mode control was used to regulate the current delivered to arcjet, and a low inductance power stage minimized switching transients. Hybrid power Metal Oxide Semiconductor Field Effect Transistors were used to minimize conduction losses. Switching losses were minimized using a fast response, optically isolated, totem-pole gate drive circuit. The input bus voltage for the unit was 150 V, with a maximum output voltage of 225 V. The switching frequency of 20 kHz was a compromise between mass savings and higher efficiency. Power conversion efficiencies in excess of 0.94 were demonstrated, along with steady state load current regulation of 1 percent. The power electronics were successfully integrated with a 10 kW laboratory hydrogen arcjet, and reliable, nondestructive starts and transitions to steady state operation were demonstrated. The estimated specific mass for a flight packaged unit was 2 kg/kW.

Hamley, John A.↗

Why the Lack of Academic Literature on Export Controls?

Export controls is currently a relevant and dynamic topic. Given the growth of global operations and the high-tech nature of many products, an increase in awareness and understanding of the impacts of export controls are necessary. A structured approach to export controls has been in existence since 1949. Despite over 50 years of history, surprisingly little academic research and literature exists on the topic. This paper explores the current export control environment and explores possible reasons for the limited academic interest. Five possible reasons are discussed: (1) dynamic nature of the topic; (2) difficulty in ensuring accurate data; (3) Complexity of the problem; (4) relatively small economic impact; and (5) sensitive information. A research approach is recommended that considers these potential obstacles.

Kremic, Tibor↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

Oxygen pressure control for electrolysis cells

Duty cycle of switched, constant current circuit controlled by pressure sensor provides oxygen at a constant pressure from a cell which electrolyzes water, eliminating possibility of cell damage by excessive oxygen demand.

Powell, J. D.↗

Adaptive Flight Control for Aircraft Safety Enhancements

This poster presents the current adaptive control research being conducted at NASA ARC and LaRC in support of the Integrated Resilient Aircraft Control (IRAC) project. The technique "Approximate Stability Margin Analysis of Hybrid Direct-Indirect Adaptive Control" has been developed at NASA ARC to address the needs for stability margin metrics for adaptive control that potentially enables future V&V of adaptive systems. The technique "Direct Adaptive Control With Unknown Actuator Failures" is developed at NASA LaRC to deal with unknown actuator failures. The technique "Adaptive Control with Adaptive Pilot Element" is being researched at NASA LaRC to investigate the effects of pilot interactions with adaptive flight control that can have implications of stability and performance.

Nguyen, Nhan T.↗

Magnetically Controlled Variable Transformer

Improved variable-transformer circuit, output voltage and current of which controlled by use of relatively small current supplied at relatively low power to control windings on its magnetic cores. Transformer circuits of this type called "magnetic amplifiers" because ratio between controlled output power and power driving control current of such circuit large. This ratio - power gain - can be as large as 100 in present circuit. Variable-transformer circuit offers advantages of efficiency, safety, and controllability over some prior variable-transformer circuits.

Kleiner, Charles T.↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗

Closed loop dynamics of in-core thermionic reactor systems.

Use of a point model of an in-core thermionic converter to investigate alternative schemes for providing closed-loop reactor control. It was found that schemes based on variable-gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small; even for a complete electric load drop the emitter temperature transient is less than 100 K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that, even though the emitter temperature distribution is about 200 K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Improved temperature control for measuring the humidity dependence of aerosol optical properties

Aerosols impact climate and cloud formation by their ability to take up water, which leads to changes in their optical properties. To better characterize the interactions of aerosol with water vapor, a humidification section has been added to the Cavity Attenuation Phase-shift Spectrometry (CAPS) instrument. The CAPS is a diode based method that provides simultaneous measurements of both aerosol total optical extinction and scattering in real-time. We are improving the humidity controlled sample line with new temperature controls. The current system suffers from particlelosses and poorly controlled humidity profiles, both of which were corrected for in the systems redesign. This improved wet-CAPS system has been integrated with a dry-CAPS to simultaneously measure the wet and dry aerosol optical properties. The two CAPS monitors were operated in a dry collection mode to ensure there were no biases between the instruments. Initial calibrations and data were collected to test the functionality of the dual CAPS system (wet + dry). The new two channel CAPS system improves our ability to measure the effects of humidity on aerosol optical properties.

58 GEOSCIENCES↗

Operation and Control of Soft Switching Solid State Transformer as a Virtual Synchronous Machine for Photovoltaic Application

Possibility for control and operation of a three-phase solid state soft switching transformer based as a virtual synchronous machine or synchronverter has been investigated in this paper. The soft switching solid state transformer is used as an interface between the ac grid and a photovoltaic power generation unit supported by a battery bank. The control architecture investigated in this paper is that of a synchronverter to achieve inertial support to the grid and local loads. The operation of the soft switching solid state transformer has also been investigated as a V S M during unbalanced/distorted grid voltage condition. Control objective to achieve oscillation free power transfer between the ports (photovoltaic, battery and grid) has been achieved. The presented architecture has been verified for several important case studies via numerical simulations based on MATLAB/Simulink domain.

grid current controller↗

An investigation of the SNS Josephson junction as a three-terminal device

A particular phenomenon of the SNS Josephson junction was investigated; i.e., control by a current entering the normal region and leaving through one of the superconducting regions. The effect of the control current on the junction was found to be dependent upon the ration of the resistances of the two halves of the N layer. A low frequency, lumped, nonlinear model was proposed to describe the electrical characteristics of the device, and a method was developed to plot the dynamic junction resistance as a function of junction current. The effective thermal noise temperature of the sample was determined. Small signal linearized analysis of the device suggests its use as an impedance transformer, although geometric limitations must be overcome. Linear approximation indicates that it is reciprocal and no power gain is possible. It is felt that, with suitable metallurgical and geometrical improvements, the device has promise to become a superconducting transistor.

Meissner, H.↗

Closed-loop Dynamics of In-core Thermionic Reactor Systems

Using a point model of an in-core thermionic converter, alternative schemes for providing closed loop reactor control were investigated. It was found that schemes based on variable gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small-even for a complete electric load drop the emitter temperature transient is less than 100 deg K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that even though the emitter temperature distribution is about 200 deg K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗