Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Are low-cost sensors good enough for IAQ controls?

Over the past few years there have been advances in sensing of some pollutants, primarily particles, that might lead to ventilation controls based on direct sensing of pollutants – particularly those relating to health. In this study we evaluated low-cost (about $200 US) IAQ monitors that measured PM2.5 - the most important health-related pollutant in indoor air. Controlled laboratory tests were carried out with known sources of particles (cooking, cleaning, candles, cigarettes) and by comparing the IAQ monitors response to research-grade and reference measurement methods. The results show a wide range of performance with the better IAQ monitors able to detect most particle sources/events and the worst ones detecting almost none. The best devices perform well enough to reliably operate a ventilation or filtration system but do not always report the correct magnitude of PM2.5 so there are restrictions on their use for calculating health effects.

Walker, Iain↗

Programmable controller system for wind tunnel diversion vanes

A programmable controller (PC) system automatic sequence control, which acts as a supervisory controller for the servos, selects the proper drives, and automatically sequences the vanes, was developed for use in a subsonic wind tunnel. Tunnel modifications include a new second test section (80 ft x 100 ft with a maximum air speed capability of 110 knots) and an increase in maximum velocity flow from 200 knots to 300 knots. A completely automatic sequence control is necessary in order to allow intricate motion of the 14 triangularly arranged vanes which can be as large as 70 ft high x 35 ft wide and which require precise acceleration and deceleration control. Rate servos on each drive aid in this control, and servo cost was minimized by using four silicon controlled rectifier controllers to control the 20 dc drives. The PC has a programming capacity which facilitated the implementation of extensive logic design. A series of diagrams sequencing the vanes and a block diagram of the system are included.

King, R. F.↗

Semi-Markov Control Processes with Unknown Holding Times Distribution Under an Average Cost Criterion

This paper deals with a class of semi-Markov control models with Borel state and control spaces, possibly unbounded costs, and unknown holding times distribution F. Assuming that F does not depend on state-action pairs, we combine suitable methods of statistical estimation of the mean holding time with control procedures to construct an average cost optimal Markovian policy {pi}-hat={l_brace}f{sub n}{r_brace}, and an optimal stationary policy {l_brace}f{sub {infinity}}{r_brace}, where f{sub n} converges to f{sub {infinity}} in the sense of Schael.

97 MATHEMATICS AND COMPUTING↗

A Low-Cost and Low-Risk Testbed for Control Design of Launch Vehicles and Landing Systems

This research seeks to bridge the gap between the simulation/theory and the flight-testing phases of control algorithmdesign for launch vehicles (LVs) and landing systems (LSs). Thispaper reviews contemporary testbeds for LV and LS control sys-tem design with an emphasis on reducing costs and risks. Also, anew low-cost and low-risk testbed utilizing a quadcopter, flexibleinverted pendulum, and a hanging pendulum is proposed. It is shown that the planar dynamic response of this proposed testbedcan match the planar dynamic response of an LV. As mission objectives for frequent cislunar and interplanetary travel become more complex, the algorithms that control LVs and LSs need to become more advanced to ensure mission safety and success. These control systems are slow to mature because it is difficult to perform experiments in an environment relevant to the mission in a safe and cost-effective manner. A solution to this problem frequently leveraged in the aviation andsatellite industries involves mimicking the dynamic response ofthe vehicle with a test platform that is low-cost and low-risk.

William J Elke III↗

An efficient cost reduction procedure for bounded-control LQR problems

A novel approach has been developed for approximating the solution to the constrained LQR problem, based on updating the final state and costate of a related regular problem, and on slightly shifting the switching times (the instants when the control meets the constraints). The main result is the expression of a suboptimal control in feedback form using the solution of some compatible Riccati equation. The gradient method is applied to reduce the cost via explicit algebraic formula for its partial derivatives with respect to the hidden final state/costate of the related regular problem and to the switching times. The numerical method is termed efficient because it does not involve integrations of states or cost trajectories, and reduces to its minimum the dimension of the unknown parameters at the final condition. All the relevant objects are calculated from a few auxiliary matrices, which are computed only once. The scheme is here applied to two case studies whose optimal solutions are known. The first example is a two-dimensional model of the ‘cheapest stop of a train’ problem. The second one refers to the temperature control of a metallic strip leaving a multi-stand rolling mill, a problem with a high-dimensional state.

97 MATHEMATICS AND COMPUTING↗

Target diagnostic control system implementation for the National Ignition Facility (invited)

The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Uncertainty from Load-Based Reserves and Renewables on Dispatch Costs and Emissions

Aggregations of controllable loads are considered to be a fast-responding, cost-efficient, and environmental-friendly candidate for power system ancillary services. Unlike conventional service providers, the potential capacity from the aggregation is highly affected by factors like ambient conditions and load usage patterns. Previous work modeled aggregations of controllable loads (such as air conditioners) as thermal batteries, which are capable of providing reserves but with uncertain capacity. A stochastic optimal power flow problem was formulated to manage this uncertainty, as well as uncertainty in renewable generation. In this paper, we explore how the types and levels of uncertainty, generation reserve costs, and controllable load capacity affect the dispatch solution, operational costs, and CO2 emissions. We also compare the results of two methods for solving the stochastic optimization problem, namely the probabilistically robust method and analytical reformulation assuming Gaussian distributions. Case studies are conducted on a modified IEEE 9-bus system with renewables, controllable loads, and congestion. We find that different types and levels of uncertainty have significant impacts on dispatch and emissions. More controllable loads and less conservative solution methodologies lead to lower costs and emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technoeconomic Design Optimization for Fast Reactors. Part II: Impact of Technoeconomic Constraints on Optimal Design

There is a current drive toward optimizing reactors, particularly small/micro reactors to minimize cost and maximize performance. Previous work has investigated the development of technoeconomic workflows for the design optimization of pool-type fast reactors that aim to deploy into district energy grids. Initial scoping studies verified that the workflow was capable of capturing design trends throughout a variety of design configurations and problem formulations while remaining sufficiently flexible. In this paper, this methodology is applied to understand how cost functions and technoeconomic constraints can drive optimal reactor design. Specifically, the UPu10Zr-fueled fast reactor model from Part I is adapted to include changes in the fissile content limits, control rod worth limits, control rod drive cost, and assumed fuel form. In the case of constraint relaxation at fixed power (fissile content and control rod worth limits), cost sensitivities of 5% to 10% were uncovered. Multi-objective optimization at varying reactor power levels with individualized control rod drives for each assembly (as opposed to one operational and one safety drive) increased cost by $\$10$ to $\$25$ million and substantially altered the optimal core geometry, favoring geometries with substantially fewer control rod placements relative to baseline optimization. Finally, a multi-objective optimization was performed at varying power levels with the fuel form overhauled to metallic, high-assay low-enriched uranium–based U10Zr with more refined fuel cost models. In the case of uranium fueling, the costs increased by at least $50 million relative to the baseline case. Furthermore, economic fuel zoning and lower reactivity swing cores were recovered. Each case serves to demonstrate the value of applying technoeconomic workflows to initial reactor design scoping studies to better understand the trade-off for a proposed concept between different design options.

Argonne Reactor Computation (ARC) codes↗

14 Steps to Creating Value in Cost and Schedule Resources for Nuclear Waste Management - 20188

While Waste Management budgets are shrinking, DOE required cost and schedule controls are becoming increasingly stringent. At the same time, there is a scarcity of adept, qualified, and competent projects controls staff who both understand nuclear waste management and are capable of addressing today's cost and schedule challenges. In response, we have developed a systematic approach to training and mentoring project controls staff. The approach is based on the observations and lessons learned on projects, both successful and unsuccessful, over the past 20 years. During that time, we evaluated staff development and used that experience to design a program that progresses the maturity, knowledge and experience of the individual. The program is based on the unique needs of cost and schedule specialists while incorporating the best leadership and managerial applications. The system is not limited to developing individual software skills, which is a primary focus of many project controls training programs. Instead, our system develops an individual's soft and hard skill sets. The system develops the user's skill, talent, attitude, and drive to do the best job possible. It focuses on all aspects of becoming a more productive technical team while accepting responsibility for individual growth. It also enhances the project controls team by setting up checks and balances that everyone is aware of and participates in. The system is based on 14 steps of increasing complexity in knowledge and application. The system clarifies roles, responsibilities and expectations. It helps eliminate uncertainty and reduces stress on staff and managers. It contains everyday routine actions and is simple to implement. It allows the development of a consistent rhythm to staff growth and development. Mastering the steps will allow the user to achieve excellence in cost and schedule control. The 14 steps are: 1 - Key Performance Objectives, 2 - Check Lists, 3 - Desktop Guides, 4 - System Description, 5 - Procedures, 6 - Software and On the Job Training (OTJ), 7 - Traceability Checks, 8 - Surveillances, 9 - 32 Criteria, 10 - The Contract, 11 - Customer/Government Guidance, 12 - Training and Mentoring Others, 13 - Master your weekly and daily schedules, 14 - Improving your interpersonal skills. Application and mastery of this system will produce better cost and schedule control results. Your project controls staff will write better reports, analyze data better, make better use of their time, and be more valuable to decision makers. If followed rigorously, our system will produce a great project controls team, which is invaluable to the success of each project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial Building Sensors and Controls Systems: Barriers and Drivers: Preprint

Building sensors and controls systems, including building automation systems, comprise the sensor-based devices installed in buildings as well as the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 13% of small commercial buildings, however, have installed sensors and controls systems, largely because of cost barriers. To accelerate adoption, this work seeks to increase the transparency of system costs and identify specific barriers and drivers. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 21 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. We collected the cost data in the form of invoices and used it to develop a percentage-based cost category breakdown. The interview data were analyzed using grounded theory to identify overarching concepts such as barriers, drivers, and future directions. From this analysis, we found the primary barriers to be complex and confusing systems, lack of user skills, and financial concerns, and the primary drivers to be operational benefits, insight into operations, and remote access to data. The future directions analysis highlighted the potential technological solutions to address gaps and barriers, as well as predicted drivers to increase adoption. This greater understanding of the costs, barriers, and drivers associated with commercial building sensors and controls systems lays the groundwork for increasing system adoption, reducing energy consumption, and transforming the market.

building automation system↗

Economically efficient operation of a power generator

A method of operating a power generator comprises receiving, a fault code corresponding to an operating condition of the power generator being outside of an acceptable range. A generator controller determines a cost of increased maintenance or repairing damage associated with overriding the fault code and maintaining existing power output from the power generator through the operating condition. A cost of a utility fine or contractual penalty associated with shutting down the power generator is determined in response to the fault code. The generator controller compares the cost of the utility fine or contractual penalty associated with shutting down the power generator with the cost of increased maintenance or damage repair to the power generator associated with overriding the fault code and maintaining existing power output through the operating condition. In response to the comparing, the fault code is overridden continuing operation of the power generator.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resonance Suppression based on Predictive Control of Grid-following Inverters with LCL Filter in Weak Grid Condition

This paper presents an effective resonance suppression control when grid interactive inverter with LCL filter experience weak grid conditions. The resonance suppression mechanism is based on finite-set model predictive control (FSMPC) with adaptive cost function to alter the controller objectives seamlessly. The large parasitic impedance and low short circuit ratio (SCR) of weak grid challenges the operation of gridconnected inverters. Specifically, the LCL filter resonance may get excited, resulting in collapse of the inverter operation. To address this issue, an effective active damping approach is implemented in the proposed control. In the proposed active damping scheme for resonance suppression, the feedback currents are switched based on the operating conditions of inverter. During the stiff grid conditions, grid current serves as feedback to the controller. While in the weak grid conditions, the inverter current is selected as feedback signal. The toggling action between these two feedback currents is determined by comparing moving RMS of grid current with threshold current as constraint in the cost function of the proposed MPC scheme. The threshold current for toggling action is based on the reference active and reactive power setpoints plus an acceptable band of variation. The theoretical analysis is verified by several case studies.

Umar, Muhammad Farooq↗

Automated Testing Experience of the Linear Aerospike SR-71 Experiment (LASRE) Controller

System controllers must be fail-safe, low cost, flexible to software changes, able to output health and status words, and permit rapid retest qualification. The system controller designed and tested for the aerospike engine program was an attempt to meet these requirements. This paper describes (1) the aerospike controller design, (2) the automated simulation testing techniques, and (3) the real time monitoring data visualization structure. Controller cost was minimized by design of a single-string system that used an off-the-shelf 486 central processing unit (CPU). A linked-list architecture, with states (nodes) defined in a user-friendly state table, accomplished software changes to the controller. Proven to be fail-safe, this system reported the abort cause and automatically reverted to a safe condition for any first failure. A real time simulation and test system automated the software checkout and retest requirements. A program requirement to decode all abort causes in real time during all ground and flight tests assured the safety of flight decisions and the proper execution of mission rules. The design also included health and status words, and provided a real time analysis interpretation for all health and status data.

Larson, Richard R.↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary study, analysis and design for a power switch for digital engine actuators

Innovative control configurations using high temperature switches to operate actuator driving solenoids were studied. The impact on engine control system life cycle costs and reliability of electronic control and (ECU) heat dissipation due to power conditioning and interface drivers were addressed. Various power supply and actuation schemes were investigated, including optical signal transmission and electronics on the actuator, engine driven alternator, and inside the ECU. The use of a switching shunt power conditioner results in the most significant decrease in heat dissipation within the ECU. No overall control system reliability improvement is projected by the use of remote high temperature switches for solenoid drivers.

Beattie, E. C.↗

Performance Evaluation of an Advanced Distributed Energy Resource Management Algorithm

This paper presents performance evaluation of a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of sub-transmission and distribution networks, the DERMS software controller, and 84 power hardware solar photovoltaic (PV) inverters, standard communication protocols, and a capacitor bank controller. The DERMS algorithm is also called, Grid-Optimization of Solar (GO-Solar) platform which includes predictive state estimation (PSE) and online multiple objective optimization (OMOO) to dispatch the legacy devices and distributed energy resources (e.g., PV). The voltage regulation performance is evaluated under three scenarios, volt-var smart inverter (baseline), and DERMS control for 100% and 30% of PV. The results show that controlling 30% of PV systems with the GO-Solar platform may provide the best balance of control performance and implementation cost.

distributed energy resource management system (DER↗