Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Photometric and spectroscopic footprint corrections in the SLOAN Digital Sky Survey’s 6th data release

We identify and correct numerous errors within the photometric and spectroscopic footprints (SFs) of the Sloan Digital Sky Survey’s (SDSS) 6th data release (DR6). Within the SDSS’s boundaries hundreds of millions of objects have been detected. Yet we present evidence that the boundaries themselves contain a significant number of mistakes that are being revealed for the first time within this paper. Left unaddressed, these can introduce systematic biases into galaxy clustering statistics. Using the DR6 Main Galaxy Sample (MGS) targets as tracers, we reveal inconsistencies between the photometric and SF definitions provided in the Catalog Archive Server (CAS), and the measurements of targets therein. First, we find that 19.7 deg{sup 2} of the DR6 photometric footprint are devoid of MGS targets. In volumes of radii 7 h{sup −1} Mpc, this can cause errors in the expected number of galaxies to exceed 60%. Second, we identify seven areas that were erroneously included or excluded from the SF. Moreover, the tiling algorithm that positioned spectroscopic fibers during and between DRs caused many areas along the edge of the SF to be significantly undersampled relative to the footprint’s interior. Through our corrections, we increase the completeness 2.2% by trimming 3.6% of the area from the existing SF. The sum total of these efforts has generated the most accurate description of the SDSS DR6 footprints ever created.

79 ASTRONOMY AND ASTROPHYSICS↗

NICMOS OBSERVATIONS OF THE TRANSITING HOT JUPITER XO-1b

We refine the physical parameters of the transiting hot Jupiter planet XO-1b and its stellar host XO-1 using Hubble Space Telescope (HST) NICMOS observations. XO-1b has a radius R{sub p} = 1.21 {+-} 0.03 R{sub J} , and XO-1 has a radius R{sub *} = 0.94 {+-} 0.02 R{sub sun}, where the uncertainty in the mass of XO-1 dominates the uncertainty of R{sub p} and R{sub *}. There are no significant differences in the XO-1 system properties between these broadband NIR observations and previous determinations based upon ground-based optical observations. We measure two transit timings from these observations with 9 s and 15 s precision. As a residual to a linear ephemeris model, there is a 2.0{sigma} timing difference between the two HST visits that are separated by three transit events (11.8 days). These two transit timings and additional timings from the literature are sufficient to rule out the presence of an Earth mass planet orbiting in 2:1 mean motion resonance coplanar with XO-1b. We identify and correct for poorly understood 'gain-like' variations present in NICMOS time series data. This correction reduces the effective noise in time series photometry by a factor of 2 for the case of XO-1.

79 ASTRONOMY AND ASTROPHYSICS↗

Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?

Purpose: To evaluate the usefulness of a six-degrees-of freedom (6D) correction using ExacTrac robotics system in patients with head-and-neck (HN) cancer receiving radiation therapy.Methods: Local setup accuracy was analyzed for 12 patients undergoing intensity-modulated radiation therapy (IMRT). Patient position was imaged daily upon two different protocols, cone-beam computed tomography (CBCT), and ExacTrac (ET) images correction. Setup data from either approach were compared in terms of both residual errors after correction and punctual displacement of selected regions of interest (Mandible, C2, and C6 vertebral bodies).Results: On average, both protocols achieved reasonably low residual errors after initial correction. The observed differences in shift vectors between the two protocols showed that CBCT tends to weight more C2 and C6 at the expense of the mandible, while ET tends to average more differences among the different ROIs.Conclusions: CBCT, even without 6D correction capabilities, seems preferable to ET for better consistent alignment and the capability to see soft tissues. Therefore, in our experience, CBCT represents a benchmark for positioning head and neck cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Attenuation correction in emission tomography using the emission data—A review

The problem of attenuation correction (AC) for quantitative positron emission tomography (PET) had been considered solved to a large extent after the commercial availability of devices combining PET with computed tomography (CT) in 2001; single photon emission computed tomography (SPECT) has seen a similar development. However, stimulated in particular by technical advances toward clinical systems combining PET and magnetic resonance imaging (MRI), research interest in alternative approaches for PET AC has grown substantially in the last years. In this comprehensive literature review, the authors first present theoretical results with relevance to simultaneous reconstruction of attenuation and activity. The authors then look back at the early history of this research area especially in PET; since this history is closely interwoven with that of similar approaches in SPECT, these will also be covered. We then review algorithmic advances in PET, including analytic and iterative algorithms. The analytic approaches are either based on the Helgason–Ludwig data consistency conditions of the Radon transform, or generalizations of John’s partial differential equation; with respect to iterative methods, we discuss maximum likelihood reconstruction of attenuation and activity (MLAA), the maximum likelihood attenuation correction factors (MLACF) algorithm, and their offspring. The description of methods is followed by a structured account of applications for simultaneous reconstruction techniques: this discussion covers organ-specific applications, applications specific to PET/MRI, applications using supplemental transmission information, and motion-aware applications. After briefly summarizing SPECT applications, we consider recent developments using emission data other than unscattered photons. In summary, developments using time-of-flight (TOF) PET emission data for AC have shown promising advances and open a wide range of applications. These techniques may both remedy deficiencies of purely MRI-based AC approaches in PET/MRI and improve standalone PET imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE DATA REDUCTION PIPELINE FOR THE APACHE POINT OBSERVATORY GALACTIC EVOLUTION EXPERIMENT

The Apache Point Observatory Galactic Evolution Experiment (APOGEE), part of the Sloan Digital Sky Survey III, explores the stellar populations of the Milky Way using the Sloan 2.5-m telescope linked to a high resolution (R ∼ 22,500), near-infrared (1.51–1.70 μm) spectrograph with 300 optical fibers. For over 150,000 predominantly red giant branch stars that APOGEE targeted across the Galactic bulge, disks and halo, the collected high signal-to-noise ratio (>100 per half-resolution element) spectra provide accurate (∼0.1 km s{sup −1}) RVs, stellar atmospheric parameters, and precise (≲0.1 dex) chemical abundances for about 15 chemical species. Here we describe the basic APOGEE data reduction software that reduces multiple 3D raw data cubes into calibrated, well-sampled, combined 1D spectra, as implemented for the SDSS-III/APOGEE data releases (DR10, DR11 and DR12). The processing of the near-IR spectral data of APOGEE presents some challenges for reduction, including automated sky subtraction and telluric correction over a 3°-diameter field and the combination of spectrally dithered spectra. We also discuss areas for future improvement.

79 ASTRONOMY AND ASTROPHYSICS↗

Fine Structure of Heliumlike Ions and Determination of the Fine Structure Constant

We report a calculation of the fine-structure splitting in light heliumlike atoms, which accounts for all quantum electrodynamical effects up to order {alpha}{sup 5} Ry. For the helium atom, we resolve the previously reported disagreement between theory and experiment and determine the fine-structure constant with an accuracy of 31 ppb. The calculational results are extensively checked by comparison with the experimental data for different nuclear charges and by evaluation of the hydrogenic limit of individual corrections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Granite Springs Valley, Nevada Play Fairway Analysis - Well data and Temperature Survey

This data is associated with the Nevada Play Fairway project and includes excel files containing raw 2-meter temperature data and corrections. GIS shapefiles and layer files contain ing location and attribute information for the data are included. Well data includes both deep and shallow TG holes, GIS shapefiles and layer files.

15 GEOTHERMAL ENERGY↗

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the magnitude of MBF errors resulting from motion in the superior/inferior and anterior/posterior directions was similar (up to 250%). Body motion effects were more detrimental for higher resolution PET imaging (2 vs 10 mm full-width at half-maximum), and for motion occurring during the mid-to-late time-frames. Motion correction of the reconstructed dynamic image series resulted in significant reduction in MBF errors, but did not account for the residual PET–CTAC misalignment artifacts. MBF bias was reduced further using global partial-volume correction, and using dynamic alignment of the PET projection data to the CT scan for accurate attenuation correction during image reconstruction. Conclusions: Patient body motion can produce MBF estimation errors up to 500%. To reduce these errors, new motion correction algorithms must be effective in identifying motion in the left/right direction, and in the mid-to-late time-frames, since these conditions produce the largest errors in MBF, particularly for high resolution PET imaging. Ideally, motion correction should be done before or during image reconstruction to eliminate PET-CTAC misalignment artifacts.

60 APPLIED LIFE SCIENCES↗

The Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: Large-scale structure catalogues for cosmological analysis

ABSTRACT We present large-scale structure catalogues from the completed extended Baryon Oscillation Spectroscopic Survey (eBOSS). Derived from Sloan Digital Sky Survey (SDSS) IV Data Release 16 (DR16), these catalogues provide the data samples, corrected for observational systematics, and random positions sampling the survey selection function. Combined, they allow large-scale clustering measurements suitable for testing cosmological models. We describe the methods used to create these catalogues for the eBOSS DR16 Luminous Red Galaxy (LRG) and Quasar samples. The quasar catalogue contains 343 708 redshifts with 0.8 < z < 2.2 over 4808 deg2. We combine 174 816 eBOSS LRG redshifts over 4242 deg2 in the redshift interval 0.6 < z < 1.0 with SDSS-III BOSS LRGs in the same redshift range to produce a combined sample of 377 458 galaxy redshifts distributed over 9493 deg2. Improved algorithms for estimating redshifts allow that 98 per cent of LRG observations result in a successful redshift, with less than one per cent catastrophic failures (Δz > 1000 km s−1). For quasars, these rates are 95 and 2 per cent (with Δz > 3000 km s−1). We apply corrections for trends between the number densities of our samples and the properties of the imaging and spectroscopic data. For example, the quasar catalogue obtains a χ2/DoF = 776/10 for a null test against imaging depth before corrections and a χ2/DoF= 6/8 after. The catalogues, combined with careful consideration of the details of their construction found here-in, allow companion papers to present cosmological results with negligible impact from observational systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-MASS STAR FORMATION IN NORMAL LATE-TYPE GALAXIES: OBSERVATIONAL CONSTRAINTS TO THE INITIAL MASS FUNCTION

We use Halpha and far-ultraviolet (FUV, 1539 A) Galaxy Evolution Explorer (GALEX) data for a large sample of nearby objects to study the high-mass (m>= 2 M {sub sun}) star formation activity of normal late-type galaxies. The data are corrected for dust attenuation using the most accurate techniques available at present, namely the Balmer decrement for Halpha data and the total far-infrared to FUV flux ratio for GALEX data. The sample shows a highly dispersed distribution in the Halpha to FUV flux ratio (log f(Halpha)/f(FUV) = 1.10 +- 0.34 A) indicating that two of the most commonly used star formation tracers give star formation rates (SFRs) with uncertainties up to a factor of 2-3. The high dispersion is partly due to the presence of active galactic nuclei, where the UV and the Halpha emission can be contaminated by nuclear activity, highly inclined galaxies, for which the applied extinction corrections are probably inaccurate, or starburst galaxies, where the stationarity in the star formation history required for transforming Halpha and UV luminosities into SFRs is not satisfied. Excluding these objects, normal late-type galaxies have log f(Halpha)/f(FUV) = 0.94 +- 0.16 A, which corresponds to an uncertainty of approx50% on the SFR. The Halpha to FUV flux ratio of the observed galaxies increases with their total stellar mass. If limited to normal star-forming galaxies, however, this relationship reduces to a weak trend that might be totally removed using different extinction correction recipes. In these objects, the Halpha to FUV flux ratio seems also barely related to the FUV - H color, the H-band effective surface brightness, the total star formation activity, and the gas fraction. The data are consistent with a Kroupa and Salpeter initial mass function (IMF) in the high-mass stellar range (m > 2 M {sub sun}) and imply, for a Salpeter IMF, that the variations of the slope gamma cannot exceed 0.25, from gamma = 2.35 for massive galaxies to gamma = 2.60 in low luminosity systems. We show however that these observed trends, if real, can be due to the different micro-history of star formation in massive galaxies with respect to dwarf systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Rotor Speed Dependent Yaw Control of Wind Turbines Based on Empirical Data

When extracting energy from the wind using horizontal-axis upwind wind turbines, a primary condition for maximum power yield is the ability to align the rotor axis with the dominating wind direction. Attempts have been made to improve yaw alignment by applying advanced measurement techniques such as LIDARs. This study is focused at assessing the current performance of an operating turbine and exploring how the yaw alignment can be improved using existing measurements. By analyzing available turbine and met mast data a correction scheme for the original yaw alignment system is synthesized. The correction scheme is applied and it is seen that with the correction scheme in place, the power yield below rated is raised 1-5 percent. Furthermore, results indicate that blade load variations are decreased when the correction scheme is applied. The results are associated with uncertainties due to the amount of available data and the wind site climate. Further work should be focused at gathering more experimental data.

17 WIND ENERGY↗

Epi Archive: automated data collection of notifiable disease data

LANL has built a software program that automatically collects global notifiable disease data—particularly data stored in files—and makes it available and shareable within the Biosurveillance Ecosystem(BSVE) as a new data source. This will improve the prediction and early warning of disease events and other applications. Most countries do not report national notifiable disease data in a machine-readable format. Data are often in the form of a file that contains text, tables and graphs summarizing weekly or monthly disease counts. This presents a problem when information is needed for more data intensive approaches to epidemiology, biosurveillance and public health as exemplified by the Biosurveillance Ecosystem(BSVE).While most nations do likely store their data in a machine-readable format, the governments are often hesitant to share data openly for a variety of reasons that include technical, political, economic, and motivational issues. For example, an attempt by LANL to obtain a weekly version of openly available monthly data, reported by the Australian government, resulted in an onerous bureaucratic reply. The obstacles to obtaining data included: paperwork to request data from each of the Australian states and territories, a long delay to obtain data (up to 3 months) and extensive limitations on the data’s use that prohibit collaboration and sharing. This type of experience when attempting to contact public health departments or ministries of health for data is not uncommon. A survey conducted by LANL of notifiable disease data reporting in 52 countries identified only 10 as being machine-readable and 42 being reported in pdf files on a regular basis. Within the 42 nations that report in pdf files, 32 report in a structured, tabular format and10 in a non-structured way. As a result, LANL has developed a tool-Epi Archive (formerly known as EPIC)-to automatically and continuously collect global notifiable disease data and make it readily accessible. We conducted a survey of the national notifiable disease reporting systems notating how the data is reported in two important dimensions: date standards and case definitions. The development of software to regularly ingests notifiable disease data frand makes this data available involved four main steps scraping, extracting, parsing and persisting. For scraping: we would examine website designs and determine reporting mechanisms for each country/website as well as what varies across the reporting mechanisms. We then designed and wrote code to automate the downloading of report pdf files, for each country. We stored report pdfs along with appropriate metadata for extracting and parsing. For extracting: we developed software that can extract notifiable disease data presented in tabular form from a pdf file. We combined the methodology of figure placement detection with the in-house developed table extraction and annotation heuristics. For parsing: we determined what to extract from each pdf dataset from the survey conducted. We then parsed the extracted data into uniform data structures correctly accommodating the dimensions surveyed and the various human languages. This task involved ingesting notifiable disease data in many disparate formats extracted from pdf files and coalescing the data into a standardized format. For persisting: We then store the data in the Epi Archive PostgreSQL database and make it available through the BSVE. The EpiArchive tool currently contains subnational notifiable disease data from 10 nations. When a user accesses the EpiArchive site, they are prompted with four fields: country, region, disease, and date duration. These fields allow the user to specify the location(down to the state level), the disease of interest, and the duration of interest. Upon form submission, a time series is generated from the users’ specifications. The generated time series can then be downloaded into a csv file if a user is interested in performing personal analysis. Additionally, the data from EpiArchive can be reached through an API. LANL as part of a currently funded DTRA effort so that it will automatically and continuously collect global notifiable disease data—particularly data stored in pdf files—and make it available and shareable within the Biosurveillance Ecosystem (BSVE) as a new data source. This will provide data to analytics and users that will improve the prediction and early warning of disease events and other applications.

59 BASIC BIOLOGICAL SCIENCES↗

SPITZER SECONDARY ECLIPSE DEPTHS WITH MULTIPLE INTRAPIXEL SENSITIVITY CORRECTION METHODS OBSERVATIONS OF WASP-13b, WASP-15b, WASP-16b, WASP-62b, AND HAT-P-22b

We measure the 4.5 μ m thermal emission of five transiting hot Jupiters, WASP-13b, WASP-15b, WASP-16b, WASP-62b, and HAT-P-22b using channel 2 of the Infrared Array Camera (IRAC) on the Spitzer Space Telescope . Significant intrapixel sensitivity variations in Spitzer IRAC data require careful correction in order to achieve precision on the order of several hundred parts per million (ppm) for the measurement of exoplanet secondary eclipses. We determine eclipse depths by first correcting the raw data using three independent data reduction methods. The Pixel Gain Map (PMAP), Nearest Neighbors (NNBR), and Pixel Level Decorrelation (PLD) each correct for the intrapixel sensitivity effect in Spitzer photometric time-series observations. The results from each methodology are compared against each other to establish if they reach a statistically equivalent result in every case and to evaluate their ability to minimize uncertainty in the measurement. We find that all three methods produce reliable results. For every planet examined here NNBR and PLD produce results that are in statistical agreement. However, the PMAP method appears to produce results in slight disagreement in cases where the stellar centroid is not kept consistently on the most well characterized area of the detector. We evaluate the ability of each method to reduce the scatter in the residuals as well as in the correlated noise in the corrected data. The NNBR and PLD methods consistently minimize both white and red noise levels and should be considered reliable and consistent. The planets in this study span equilibrium temperatures from 1100 to 2000 K and have brightness temperatures that require either high albedo or efficient recirculation. However, it is possible that other processes such as clouds or disequilibrium chemistry may also be responsible for producing these brightness temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. Erratum

Please insert erratum page in report PNNL-14805. This erratum serves to correct the K g (Glass apparent equilibrium constant based on the SiO 2 (aq) activity) values affected by a calculation error for glasses LAWA44, LAWB45 and LAWC22. The error was first identified by Papathanassiu et al. (2011). The K g values were corrected by Freedman et al. (2015) by multiplying the erroneous K g values by approx. 3.4. As indicated in Freedman et al. (2015), this 3.4 factor originates from the erroneous use of the molecular weight of H 4 SiO 4 (96.114 g·mol –1 ) instead of the molecular weight for Si (28.086 g·mol –1 ).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the ring tension test (RTT) for robust determination of material strengths

The ring tension test (RTT) is an experimental method for determining mechanical behavior in a material’s circumferential or hoop direction. It is a crucial test for testing anisotropic materials with tube geometry, such as nuclear fuel cladding or irradiated pipes. Several RTT configurations exist, each with their own advantages and disadvantages. However, this test is significantly more complex than traditional tensile testing and can be especially sensitive to small differences and inconsistencies in the test setup and geometry, ultimately affecting the derived mechanical properties. Previous research has focused on method development, and little work has been done on understanding the subtle differences between an ideal test and experiments, specifically when the tests are performed on highly irradiated materials in hot cells. In this work, a finite element-based investigation of the RTT is conducted to fill this gap. The two most used test configurations are investigated, comparing their ability to determine accurate material strengths through plastic deformation. Several non-ideal conditions and uncontrollable effects which are likely to occur during experimental testing such as machining tolerances, variations of specimen geometry from nominal dimensions, rotation of specimens and fixturing, and other test setup discrepancies are studied. The sensitivity of measured strengths to these conditions is presented. A mechanics-based approach to describing and correcting raw data to determine actual strengths is also included for one of the configurations, resulting in a robust correction method with highly accurate material strength measurements. Finally, based on these analyses, the hemicylindrical mandrel configuration is recommended with a gauge region oriented at a 45° angle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanics of the Ring Tension Test (RTT): A Finite Element-based Investigation

The ring tension test (RTT) is an experimental method for determining mechanical behavior in a material’s circumferential or hoop direction. It is a crucial test for testing anisotropic materials with tube geometry, such as nuclear fuel cladding or irradiated pipes. Several RTT configurations exist, each with their own advantages and disadvantages. However, this test is significantly more complex than traditional tensile testing and can be especially sensitive to small differences and inconsistencies in the test setup and geometry, ultimately affecting the derived mechanical properties. Previous research has focused on method development, and little work has been done on understanding the subtle differences between an ideal test and experiments, specifically when the tests are performed on highly irradiated materials in hot cells. In this work, a finite element-based investigation of the RTT is conducted. Two promising test configurations are investigated, comparing their ability to determine accurate material strengths through plastic deformation. Several non-ideal conditions and uncontrollable effects which are likely to occur during experimental testing such as machining tolerances, variations of specimen geometry from nominal dimensions, rotation of specimens and fixturing, and other test setup discrepancies are studied. The sensitivity of measured strengths to these conditions is presented. A mechanics-based approach to describing and correcting raw data to determine actual strengths is also included for one of the configurations, resulting in a robust correction method with highly accurate material strength measurements. Based on these analyses, the hemicylindrical mandrel configuration is recommended with a gauge region oriented at a 45° angle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗