Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling & trapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

378 records · Page 21

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

BOILER Experiment Material Characterization and HFIR Irradiation Status

Pre-oxidized alumina-forming austenitic (AFA) steels have been previously identified as candidate alloys for structural components in lead-cooled fast reactors (LFRs). They offer compatibility with liquid Pb, high-temperature strength, formability, and cost advantages. However, variations in Ni content can affect the formation and stability of the Al 2 O 3 layer, influencing compatibility with liquid Pb. The effect of fast neutron irradiation on Al 2 O 3 stability in liquid Pb also requires evaluation. Therefore, understanding how Ni concentrations impacts pre-oxidized AFAs under combined extremes of irradiation and liquid metal corrosion is essential before safe deployment. The Behavior Of In-situ Lead Environments & Radiation (BOILER) experiment was developed under the Nuclear Science User Facilities (NSUF) program to integrate alloy development, irradiation experiment design, and irradiated materials characterization. In this effort, two pre-oxidized AFA steels with 20 wt% and 25 wt% Ni, hereinafter referred to as GA05-20Ni and GA05-25Ni, were produced. An irradiation experiment was then planned for the High Flux Isotope Reactor (HFIR), designed for passive heating of irradiation rabbit capsules from gamma heating in the HFIR flux trap (1 × 10 15 n/cm 2 ·s, >0.1 MeV). This heating melts Pb and exposes the pre-oxidized AFA steel specimens to nominal temperatures of 400 and 650°C. Detailed neutronics and thermal analyses were performed, though based on nominal design rather than as-built, as-irradiated conditions. This report documents further characterization of the pre-oxidized AFAs in the unirradiated condition. It also includes as-built thermal analysis using measured component dimensions, updated fill gas concentrations, and actual HFIR irradiation positions. Finally, the report summarizes capsule fabrication, current irradiation status, projected completion, estimated damage accumulation, and initial plans for post-irradiation examination plans.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ARC-100 Reactor Security-by-Design Summary

This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the Advanced Reactor Concepts 100 (ARC-100) sodium-cooled fast reactor (SFR) design. The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, and used fuel assembly wash station. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. However, the consequence assessment results are the similar to a previously assessed generic SFR. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. This work will continue in the Fiscal Year 2025 for the remaining ARC-100 systems, including cesium trap, sodium cold trap, noble gas decay tanks (dewar bottles), and used fuel dry storage facility, to provide safety-and-security-by-design insights and recommendations on non-core systems. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Abundance of spring‐ and winter‐active arthropods declines with warming

Abstract Because ectotherm activity and metabolism are sensitive to temperature, terrestrial arthropods may be especially responsive to ongoing climatic warming. Here, we quantified responses of arthropod abundance to two years of warming in an outdoor temperature manipulation experiment at Duke Forest, North Carolina, USA. Nine open‐top chambers were individually heated year‐round from 1.5° to 5.5°C above ambient temperature. From two years of monthly pitfall trapping, we collected and identified 4,468 arthropods representing 24 orders. We initially predicted that arthropods would experience the greatest negative effects of experimental warming during the summer months, when temperatures reach their yearly maximum and arthropods may be close to their maximum thermal tolerance limits. Instead, we found that the strongest negative effects on arthropod abundance occurred during the winter and spring, when ambient temperatures are relatively cooler, whereas the effects of experimental warming on abundance were not significant during the summer or fall. During the spring of 2012, the warmest spring on record for the southeastern USA, total arthropod abundance declined 20% per °C of experimental warming. Abundance declines were driven largely by flies (Diptera), which were the most abundant insect order, representing approximately a third of all arthropods collected. The most abundant arthropod family, Mycetophilidae (fungus gnats), declined 64% per °C of warming during the spring of 2012. Although previous research on climatic warming has focused on the impact of maximum yearly temperatures on organismal performance, our results are more consistent with the cool‐season sensitivity hypothesis, which posits that arthropods adapted for cooler conditions are likely to face the strongest negative effects of warming during the cooler seasons.

54 ENVIRONMENTAL SCIENCES↗

Submillimeter-Wave Cloud Ice Radiometry

Submillimeter-wave cloud ice radiometry is a new and innovative technique for characterizing cirrus ice clouds. Cirrus clouds affect Earth's climate and hydrological cycle by reflecting incoming solar energy, trapping outgoing IR radiation, sublimating into vapor, and influencing atmospheric circulation. Since uncertainties in the global distribution of cloud ice restrict the accuracy of both climate and weather models, successful development of this technique could provide a valuable tool for investigating how clouds affect climate and weather. Cloud ice radiometry could fill an important gap in the observational capabilities of existing and planned Earth-observing systems. Using submillimeter-wave radiometry to retrieve properties of ice clouds can be understood with a simple model. There are a number of submillimeter-wavelength spectral regions where the upper troposphere is transparent. At lower tropospheric altitudes water vapor emits a relatively uniform flux of thermal radiation. When cirrus clouds are present, they scatter a portion of the upwelling flux of submillimeter-wavelength radiation back towards the Earth as shown in the diagram, thus reducing the upward flux o f energy. Hence, the power received by a down-looking radiometer decreases when a cirrus cloud passes through the field of view causing the cirrus cloud to appear radiatively cool against the warm lower atmospheric thermal emissions. The reduction in upwelling thermal flux is a function of both the total cloud ice content and mean crystal size. Radiometric measurements made at multiple widely spaced frequencies permit flux variations caused by changes in crystal size to be distinguished from changes in ice content, and polarized measurements can be used to constrain mean crystal shape. The goal of the cloud ice radiometry program is to further develop and validate this technique of characterizing cirrus. A multi-frequency radiometer is being designed to support airborne science and spacecraft validation missions. This program has already extended the initial millimeter-wave modeling studies to submillimeter-wavelengths and has improved the realism of the cloud scattering models. Additionally a proof-of-concept airborne submillimeter-wave radiometer was constructed and fielded. It measured a radiometric signal from cirrus confirming the basic technical feasibility of this technique. This program is a cooperative effort of the University of Colorado, Colorado State University, Swales Aerospace, and Jet Propulsion Laboratory. Additional information is contained in the original.

Walter, Steven J.↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AGR 5/6/7 Data Qualification Report for ATR Cycles 162B through 168A

This report provides the qualification status of experimental data for the Advanced Gas Reactor (AGR) 5/6/7 fuel irradiation. AGR-5/6/7 was conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tri-structural isotropic (TRISO) low-enriched fuel for use in high temperature gas-cooled reactors. The objectives of the AGR-5/6/7 experiments are to: (i) irradiate reference-design fuel particles to support fuel qualification, (ii) establish operating margins for the fuel beyond normal operating conditions, and (iii) provide irradiated-fuel performance data and irradiated-fuel samples for post-irradiation examination (PIE) and safety testing. The test train contains five separate capsules that were independently controlled and monitored. Each capsule contains multiple 12.51-mm-long compacts filled with low enriched uranium carbide/oxide (UCO) TRISO fuel particles. The primary objective of the AGR-5/6 test (Capsules 1, 2, 4, and 5) is to verify successful performance of the reference-design fuel under normal operating conditions. The AGR-7 test (Capsule 3) was designed to explore fuel performance at higher temperatures to demonstrate the capability of the fuel to withstand conditions beyond normal operating conditions in support of plant design and licensing. AGR 5/6/7 will also provide irradiated-fuel performance data on fission-gas release from failed particles during irradiation. The AGR-5/6/7 capsules were irradiated in the ATR northeast flux trap location. The experiment began on February 16, 2018 and ended on July 22, 2020, spanning nine ATR cycles over two and a half years. Thus, the AGR-5/6/7 fuel compacts were irradiated for a total of 360.9 effective full power days. The AGR 5/6/7 experiment was able to remain in the reactor core during all three Powered Axial Locator Mechanism (PALM) cycles (163A, 165A, and 167A) without overheating its fuel compacts. This report includes irradiation monitoring data from nine ATR Cycles: 162B, 163A, 164A, 164B, 165A, 166A, 166B, 167A, and 168A, as stored in the Nuclear Data Management and Analysis System (NDMAS). During irradiation, data records consisted of instantaneous measurements recorded every minute and provided by text files automatically every 2 hours. The AGR 5/6/7 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates [capsule inlet, outlet, and downstream at detector], pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates and release to birth rate ratios [R/Bs]) for each of the five capsules. A total of 94,989,908 TC temperature and sweep gas data records were received and processed by NDMAS for AGR 5/6/7 irradiation. Of these records, 41,593,387 (or 43.7% of the total) met data collection and accuracy requirements and are labeled as Qualified. A total of 57,746,693 TC temperature readings were captured from 54 installed TCs. Among them, 10,034,676 TC temperature records (only 17.4%) were Qualified and 47,701,371 TC temperatures (or 82.6%) are Failed due to 48 TC failures (63.5%) and due to missing values (19.1%). To assess performance of the operational TCs, analysis of daily correlations between TCs found no evidence of virtual junction failure for any TCs. Analyses on control charts of TC temperature differences revealed trending in TC readings for TC2, 4, 5, and 13 in Capsule 3, but there is no conclusive indication of TC drift failure that caused those trends. Therefore, TC control charts are not used to disqualify TC data, but only for users’ consideration. For sweep gas flow rates, a total of 31,519,747 gas flow records (84.4%) are Qualified for use for AGR-5/6/7 experiment; 5,723,468 gas flow records (15.4%) are Failed due mostly to missing values; and 74,641 high sweep gas flow rates (0.2 %) are Trend. A large number of Failed missing TC temperature and gas flow values were caused by an error in the data output script that outputted a ‘NULL’ value when values were unchanged. This problem was fixed during the outage of Cycle 166B, which led to a substantially decreased number of missing values during the last three cycles. Nonetheless, a large amount of non-missing data remained because of the high data acquisition frequency (1-minute) and still provided sufficient data to effectively monitor the experiment as designed. For FPMS data, NDMAS received and processed fission product release and R/B data for nine ATR cycles, when ATR core reached full power during AGR 5/6/7 irradiation. These data consist of 110,388 release rate records and 110,388 R/B records for the twelve radionuclides (Kr 85m, Kr 87, Kr 88, Kr 89, Kr 90, Xe 131m, Xe 133, Xe 135, Xe 135m, Xe 137, Xe 138, and Xe 139) for each of the five capsules. Equivalent numbers of uncertainty records associated the release rates and R/B values were provided. To date, qualification status of the FPMS data stored in the NDMAS dat

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Apollo 15 Mare Basalt Fragment and Lunar Mare Provinces

Lunar sample 15474,4 is a tiny fragment of olivine-augite vitrophyre that is a mare basalt. Although petroraphically distinct from all other Apollo 15 samples, it has been ignored since its first brief description. Our new petrographic and mineral chemical data show that the olivines and pyroxenes are distinct from those in other basalts. The basalt cooled and solidified extremely rapidly; some of the olivine might be cumulate or crystallized prior to extrusion. Bulk-chemical data show that the sample is probably similar to an evolved Apollo 15 olivine-normative basalt in major elements but is distinct in its rare earth element pattern. Its chemical composition and petrography both show that 15474,4 cannot be derived from other Apollo 15 mare basalts by shallow-level crystal fractionation. It represents a distinct extrusion of magma. Nonetheless, the chemical features that 15474,4 has in common with other Apollo 15 mare basalts, including the high FeO/Sc, the general similarity of the rare earth element pattern, and the common (and chondritic) TiO2/Sm ratio, emphasize the concept of a geochemical province at the Apollo 15 site that is distinct from basalts and provinces elsewhere. In making a consistent picture for the derivation of all of the Apollo 15 basalts, both the commonalities and the differences among the basalts must be explained. The Apollo 15 commonalities and differences suggest that the sources must have consisted of major silicate phases with the same composition but with varied amounts of a magma trapped from a contemporary magma ocean. They probably had a high olivine/pyroxene ratio and underwent small and reasonably consistent degrees of partial melting to produce the basalts. These inferences may be inconsistent with models that suggest greatly different depths of melting among basalts, primitive sources for the green glasses, or extensive olivine fractionation during ascent. An integrated approach to lunar mare provinces, of which the Apollo 15 mare basalts constitute only one, offers advances in our understanding of the physical and chemical processes of source formation and mare production but has so far not been utilized.

Ryder, Graham↗

Radiation Environment and Surface Radiolytic Interactions at Mimas

Saturn's innermost principal moon Mimas shares the distinction with Europa at Jupiter of being the most irradiated icy moon in its respective planetary system, although the energetic electron energy flux at Mimas is forty times smaller than at Europa. High energy (> 10 MeV) proton fluxes are low in this moon's orbital corridor, likely since slowly diffusing protons from the weak but steady source of cosmic ray albedo neutron decay (CRAND) cannot accumulate without impacting the moon surface. Lower energy proton fluxes are also evidently suppressed in this orbital region. Plasma ion and electron fluxes are also low apparently due to cooling by interaction with E-ring dust and neutral gas from Enceladus. Due to energy-dependent effects of longitudinal gradient-curvature drift for the electrons, the trailing hemisphere is mainly irradiated by electrons at energies below 1 MeV that drift relative to Mimas in the prograde direction of orbital motion around Saturn, while higher energy electrons primarily impact the leading hemisphere. Plasma ions in the inner magnetosphere of Saturn are mainly pickup ions forming from the dissociation products of Enceladus plume water molecules, additionally including some contribution from photosputtering of the main rings, and do not introduce new elemental materials at Mimas via surface implantation from the corotating plasma. Thus the primary interaction at the surface is radiolytic chemistry induced in pure water ice by relatively deep penetration of the energetic electrons to millimeter and greater depths, as compared to the micron depths impacted by the corotating plasma ions. If surface erosion by sputtering from relatively low fluxes of the plasma and more energetic ions is indeed ineffective, then molecular products (OH, H2O2, 02, 03) of the radiolytic interactions may accumulate in the meters-deep impact regolith of the surface ices. An effect of regolith trapped gas accumulation could be to increase porosity and reduce thermal conductivity of the ice, potentially contributing to reported thermal anomalies from Cassini infrared map observations. Low amplitude of trailing-leading asymmetry in optical albedo and color maps at Mimas is suggestive of relative weakness of asymmetrical effects from low-energy ions. Greater induced asymmetries are expected and observed for the moons beyond Enceladus in the middle magnetospheric region of hot plasma ions at much greater fluxes than at Mimas. Low density (1.15 g/cc) of this moon indicates paucity of mineral salts and radiogenic heating to maintain subsurface liquids, so Enceladus-like cryovolcanism as a resurfacing process is unlikely despite closer proximity to Saturn, greater tidal forcing, and more intense surface irradiation than for Enceladus.

Cooper, J. F.↗

Analysis of Direct Samples of Early Solar System Aqueous Fluids

Over the past three decades we have become increasingly aware of the fundamental importance of water, and aqueous alteration, on primitive solar-system bodies. Some carbonaceous and ordinary chondrites have been altered by interactions with liquid water within the first 10 million years after formation of their parent asteroids. Millimeter to centimeter-sized aggregates of purple halite containing aqueous fluid inclusions were found in the matrix of two freshly-fallen brecciated H chondrite falls, Monahans (1998, hereafter simply "Monahans") (H5) and Zag (H3-6) (Zolensky et al., 1999; Whitby et al., 2000; Bogard et al., 2001) In order to understand origin and evolution of the aqueous fluids inside these inclusions we much measure the actual fluid composition, and also learn the O and H isotopic composition of the water. It has taken a decade for laboratory analytical techniques to catch up to these particular nanomole-sized aqueous samples. We have recently been successful in (1) measuring the isotopic composition of H and O in the water in a few fluid inclusions from the Zag and Monahans halite, (2) mineralogical characterization of the solid mineral phases associated with the aqueous fluids within the halite, and (3) the first minor element analyses of the fluid itself. A Cameca ims-1270 equipped with a cryo-sample-stage of Hokkaido University was specially prepared for the O and H isotopic measurements. The cryo-sample-stage (Techno. I. S. Corp.) was cooled down to c.a. -190 C using liquid nitrogen at which the aqueous fluid in inclusions was frozen. We excavated the salt crystal surfaces to expose the frozen fluids using a 15 keV Cs+ beam and measured negative secondary ions. The secondary ions from deep craters of approximately 10 m in depth emitted stably but the intensities changed gradually during measurement cycles because of shifting states of charge compensation, resulting in rather poor reproducibility of multiple measurements of standard fluid inclusions of +/- 90 0/00(2 sigma) for delta D, and +/- 29 0/00 (2 sigma) for delta O-18. On the other hand, the reproducibility of Delta O-17 is plus or minus 8 /00 (2 sigma ) because the observed variations of isotope ratios follow a mass dependent fractionation law. Variations of delta D of the aqueous fluids range over sog,a 330(90; 2 sigma ) to +1200(90) 0/00 for Monahans and delta 300(96) 0/00 to +90(98)0/00 for Zag. Delta O-17 of aqueous fluids range over delta 16(22) 0/00 to +18(10) 0/00 for Monahans and +3(10) 0/00 to +27(11) 0/00 for Zag. These variations are larger than the reproducibility of standard analyses and suggest that isotope equilibria were under way in the fluids before trapping into halite. The mean values of delta D and Delta O-17 are +290 0/00 and +9 0/00, respectively. The mean values and the variations of these fluids are different from the representative values of ordinary chondrites, verifying our working hypothesis that the fluid inclusion-bearing halites were not indigenous to the H chondrite parent-asteroid but rather represent exogenous material delivered onto the asteroid from a separate cryovolcanically-active body. This initial isotopic work has demonstrated the feasibility of the measurements, but also revealed sample processing and analytical shortcomings that are now being addressed. Examination of solid mineral inclusions within Monahans and Zag halite grains by confocal Raman spectroscopy at the Carnegie Geophysical Laboratory has revealed them to be metal, magnetite, forsteritic olivine (Fo.98), macromolecular carbon (MMC), pyroxenes, feldspar with Raman spectral affinity to anorthoclase and, probably, fine-grained lepidocrocite (FeO(OH)). In addition, one inclusion features aliphatic material with Raman spectral features consistent with a mixture of short-chain aliphatic compounds. We have initiated analyses of the bulk composition of the fluids within the inclusions in Zag and Monahans halites at Virginia Tech by LA ICPMS using angilent 7500ce quadrupole ICPMS and a Lambda Physik GeoLas 193 nm excimer laser ablation system. Preliminary results reveal that the inclusion aqueous fluids contain highly charged cations of Ca, Mg and Fe. The minerals and compounds discovered thus far within Monahans/Zag halites are indicative of an originating body at least partly composed of unequilibrated anhydrous materials (high Fo olivine, pyroxenes, feldspars, possibly the metal) which were subjected to aqueous alteration (the halite parent brine) and containing a light organic component (the short-chain aliphatic compounds). This material was ejected from the originating body with little or no disruption, as evidenced with the presence of fluid inclusions. An actively geysering body similar to modern Enceladus (Postberg et al., 2011) may be a reasonable analogue in this respect. Also, the originating body should have been within close proximity to the H chondrite parent in order to generate the number of halite grains seen in Monahans and Zag. Other candidates for Monahans/Zag halite parent bodie(s) may include a young Ceres with its possible liquid ocean, or Main Belt comets.

Zolensky, Michael E.↗

A Magnetic Bumper-Tether System Using ZFC Y123

We consider the use of magnetic forces in a bumper system, to soften docking procedures. We investigate a system which exhibits no magnetic field except during the docking process, which, if desired, can automatically tether two craft together, and which provides lateral stability during docking. A system composed of zero field cooled Y(1.7)Ba2Cu3O(7-delta) (Y123) tiles and electromagnets is proposed. The Y123 high temperature superconductor (HTS) is mounted on one craft, and the electromagnet on the other. Results of small prototype laboratory experiments are reported. The electromagnet has, for convenience, been replaced by a permanent SmCo ferromagnet in these measurements. When the two craft approach, a mirror image of the ferromagnet is induced in the Y123, and a repulsive bumper force, F(sub B), results. F(sub B) is velocity dependent, and increases with v. For presently available HTS materials, bumper pressure of approx. 3.7 N/cm(exp 2) is achieved using SmCo. This extrapolates to approx. 18 N/cm(exp 2) for an electromagnet, or a force of up to 20 tons for a 1 m(exp 2) system. After reaching a minimum distance of approach, the two colliding craft begin to separate. However, the consequent change of SmCo magnetic field at the Y123 results in a reversal of current in the Y123 so that the Y123 is attractive to the SmCo. The attractive (tether) force, F(sub T), is a function of R = B(sub Fe)/B(sub t, max), where B(sub Fe) is the field at the surface of the ferromagnet, and B(sub t, max) is the maximum trapped field of the Y123, i.e., the trapped field in the so-called critical state. For R greater than or equal to 2, F(sub T) saturates at a value comparable to F(sub B). For a range of initial approach velocities the two craft are tethered following the bumper sequence. Most of the kinetic energy of the collision is first converted to magnetic field energy in the Y123, and then into heat via the creep mechanism. About 15% of the work done against magnetic forces during collision remains stored as magnetic energy after 1 hour. Experiments have also been conducted on the spatial range of the bumper force for arrays of HTS tiles. For a single HTS tile approx. 2 cm in diameter, the range of F(sub B) is approx. l cm. For a l m(exp 2) array the range of F(sub B) will be circa 50 cm.

Weinstein, Roy↗

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Test Results for a MEMS Microshutter Operating at 60 K

The James Webb Space Telescope (JWST), the successor to the Hubble Space Telescope, is due to be launched in 2013 with the goal of searching the very distant Universe for stars that formed shortly after the Big Bang. Because this occurred so far back in time, the available light is strongly red-shifted, requiring the use of detectors sensitive to the infrared portion of the electromagnetic spectrum. HgCdTe infrared focal plane arrays, cooled to below 30 K to minimize noise, will be used to detect the faint signals. One of the instruments on JWST is the Near Infrared Spectrometer (NIRSPEC) designed to measure the infrared spectra of up to 100 separate galaxies simultaneously. A key component in NIRSPEC is a Micro-Electromechanical System (MEMS), a two-dimensional micro-shutter array (MSA) developed by NASA/GSFC. The MSA is inserted in front of the detector to allow only the light from the galaxies of interest to reach the detector and to block the light from all other sources. The MSA will have to operate at 30 K to minimize the amount of thermal radiation emitted by the optical components from reaching the detector array. It will also have to operate in the space radiation environment that is dominated by the MSA will be exposed to a large total ionizing dose of approximately 200 krad(Si). Following exposure to ionizing radiation, a variety of MEMS have exhibited performance degradation. MEMS contain moving parts that are either controlled or sensed by changes in electric fields. Radiation degradation can be expected for those devices where there is an electric field applied across an insulating layer that is part of the sensing or controlling structure. Ionizing radiation will liberate charge (electrons and holes) in the insulating layers, some of which may be trapped within the insulating layer. Trapped charge will partially cancel the externally applied electric field and lead to changes in the operation of the MEMS. This appears to be a general principle for MEMS. Knowledge of the above principle has raised the concern at NASA that the MSA might also exhibit degraded performance because, i) each shutter flap is a multilayer structure consisting of metallic and insulating layers and ii) the movement of the shutter flaps is partially controlled by the application of an electric field between the shutter flap and the substrate (vertical support grid). The whole mission would be compromised if radiation exposure were to prevent the shutters from opening and closing properly. energetic ionizing particles. Because it is located A unique feature of the MSA is that, as outside the spacecraft and has very little shielding, previously mentioned, it will have to operate at temperatures near 30 K. To date, there are no published reports on how very low temperatures (- 30K) affect the response of MEMS devices to total ionizing dose. Experiments on SiO2 structures at low temperatures (80 K) indicate that the electrons generated by the ionizing radiation are mobile and will move rapidly under the application of an external electric field. Holes, on the other hand, that would normally move in the opposite direction through the SiO2 via a "thermal hopping" process, are effectively immobile at low electric fields as they are trapped close to their generation sites. However, for sufficiently large electric fields (greater than 3 MV/cm) holes are able to move through the SiO2. The larger the field, the more rapidly the holes move. The separation of the electrons and holes leads to a reduced electric field within the insulating layer. To overcome this reduction in electric field, a greater external voltage will have to be applied that alters the normal operation of the device. This report presents the results of radiation testing of the MSA at 60 K. The temperature was higher than the targeted temperature because of a faulty electrical interconnect on the test board. Specifically, our goal was to determine whether the MSA would function propey after a TID of 200 krad(Si).

Rapchun, David A.↗

Single Particle Damage Events in Candidate Star Camera Sensors

Si charge coupled devices (CCDs) are currently the preeminent detector in star cameras as well as in the near ultraviolet (uv) to visible wavelength region for astronomical observations in space and in earth-observing space missions. Unfortunately, the performance of CCDs is permanently degraded by total ionizing dose (TID) and displacement damage effects. TID produces threshold voltage shifts on the CCD gates and displacement damage reduces the charge transfer efficiency (CTE), increases the dark current, produces dark current nonuniformities and creates random telegraph noise in individual pixels. In addition to these long term effects, cosmic ray and trapped proton transients also interfere with device operation on orbit. In the present paper, we investigate the dark current behavior of CCDs - in particular the formation and annealing of hot pixels. Such pixels degrade the ability of a CCD to perform science and also can present problems to the performance of star camera functions (especially if their numbers are not correctly anticipated). To date, most dark current radiation studies have been performed by irradiating the CCDs at room temperature but this can result in a significantly optimistic picture of the hot pixel count. We know from the Hubble Space Telescope (HST) that high dark current pixels (so-called hot pixels or hot spikes) accumulate as a function of time on orbit. For example, the HST Advanced Camera for Surveys/Wide Field Camera instrument performs monthly anneals despite the loss of observational time, in order to partially anneal the hot pixels. Note that the fact that significant reduction in hot pixel populations occurs for room temperature anneals is not presently understood since none of the commonly expected defects in Si (e.g. divacancy, E center, and A-center) anneal at such a low temperature. A HST Wide Field Camera 3 (WFC3) CCD manufactured by E2V was irradiated while operating at -83C and the dark current studied as a function of temperature while the CCD was warmed to a sequence of temperatures up to a maximum of +30C. The device was then cooled back down to -83 and re-measured. Hot pixel populations were tracked during the warm-up and cool-down. Hot pixel annealing began below 40C and the anneal process was largely completed before the detector reached +3OC. There was no apparent sharp temperature dependence in the annealing. Although a large fraction of the hot pixels fell below the threshold to be counted as a hot pixel, they nevertheless remained warmer than the remaining population. The details of the mechanism for the formation and annealing of hot pixels is not presently understood, but it appears likely that hot pixels are associated with displacement damage occurring in high electric field regions.

Marshall, Paul↗

Toward a high-fidelity tritium transport modeling for retention and permeation experiments

We report Tritium Migration Analysis Program version 8 (TMAP8), the latest version of TMAP, was developed within the framework of the Multiphysics Object-Oriented Simulation Environment (MOOSE). Created at Idaho National Laboratory (INL), MOOSE is an open-source, dimension-agnostic, fully coupled, and fully implicit multiphysics platform featuring massively parallel computation capabilities. Using TMAP8, tritium transport in a divertor monoblock was analyzed to elucidate the effects of pulsed operation (up to fifty 1,600 s plasma discharge and cool-down cycles) on the tritium in-vessel inventory source term and ex-vessel release term (i.e., tritium retention and permeation) for safety analysis. With its built-in Message Passing Interface capability, TMAP8 can, in under 2 h, simulate tritium transport in three different layered materials (i.e., tungsten, copper, and copper-chromium-zirconium alloy) in 2D geometry, using a single device/computer with 10 cores. The MOOSE-based TMAP8 code can leverage other MOOSE tools developed under the Nuclear Energy Advanced Modeling and Simulation program to perform tritium and thermal transport in complex geometries and multiphysics environments. And via its massively parallel computation, MOOSE will enable the fusion pilot plant designers to conduct high-fidelity multiphysics modeling for the design of the divertor and blanket systems as well as for the safety analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Assessment of Off-Gas System Technologies for Potential Use in Molten Salt Reactors

Molten salt reactors (MSRs) are a class of Generation IV advanced reactor technologies aimed to enhance and improve the safety, fuel utilization and cost-effectiveness of nuclear power generation. MSR concepts are based on using a molten salt mixture as a primary nuclear reactor coolant, while the fuel can be either directly dissolved in the coolant (i.e., fluid-fueled) or can be in a separate solid form (i.e., salt-cooled solid-fueled). MSRs can be operated in either thermal or fast neutron spectra, as simple fissile convertors, or breeder reactors (e.g., utilizing both fissile and fertile fuels), as well as accelerator-driven sub-critical reactors or transuranic element burners. Operation of MSRs will necessitate management and treatment of the off-gas streams released to the headspace of the reactor where, in some designs, a cover gas can be circulated to remove certain fission products and maintain an inert atmosphere. An inert MSR cover gas swept over or sparged into the salt will confine radionuclides emerging from the free surface, including radioactive noble and non-noble gases, aerosols, and volatile species. The elements and compounds of these species will have a wide range of thermochemical and physical properties, some of which will decay to different products in the off-gas stream. Therefore, system components used to manage and treat MSR off-gas streams will need to be robust under dynamic reactor and chemistry conditions to support adequate reactor performance by managing the composition and species in the salt coolant and cover gas space. Off-gas system components would perform as a radionuclide boundary to the reactor vessel and a primary means for preventing radionuclide release; therefore, they are of high safety significance for MSR operations. This report reviews various technologies and materials for potential implementation in the design of an MSR off-gas system per a general conceptual framework. The reviewed technologies operate based on scrubbing, capture, delay, or separation of species in the off-gas stream. These include molten hydroxide scrubbers, solid sorbents, delay off-gas systems, particle traps, and cryogenic distillation. Since aspects of an off-gas system will be design-specific, the approach is to provide general discussions on attributes of these technologies and materials, including target off-gas stream species, operational parameters and conditions of importance to decontamination factors, implementation maturity, system component monitoring, potential off-normal conditions and considerations for waste products. The information aims to support the U.S. Nuclear Regulatory Commission in their safety evaluations for MSR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Observation of a dipole-bound excited state in 4-ethynylphenoxide and comparison with the quadrupole-bound excited state in the isoelectronic 4-cyanophenoxide

Negative ions do not possess Rydberg states, but can have Rydberg-like nonvalence excited states near the electron detachment threshold, including dipole-bound states (DBSs) and quadrupole-bound states (QBSs). While DBSs have been studied extensively, quadrupole-bound excited states have been more rarely observed. 4-cyanophenoxide (4CP – ) was the first anion observed to possess a quadrupole-bound exited state 20 cm-1 below its detachment threshold. Here we report the observation of a DBS in the isoelectronic 4-ethynylphenoxide anion (4EP – ), providing a rare opportunity to compare the behaviors of a dipole-bound and a quadrupole-bound excited state in a pair of very similar anions. Photodetachment spectroscopy (PDS) of cryogenically-cooled 4EP – reveals a DBS 76 cm -1 below its detachment threshold. Photoelectron spectroscopy (PES) at 266 nm shows that the electronic structure of 4EP – and 4CP – are nearly identical. The observed vibrational features in both the PDS and PES, as well as autodetachment from the nonvalence excited states, are also found to be similar for both anions. However, resonant two-photon detachment (R2PD) from the bound vibrational ground state is observed to be very different for the DBS in 4EP – and the QBS in 4CP – . The R2PD spectra reveal that decays take place from both the DBS and QBS to the respective anion ground electronic states within the 5 ns detachment laser pulse due to internal conversion followed by intramolecular vibrational redistribution (IVR), but the decay mechanisms appear to be very different. In the R2PD spectrum of 4EP – , we observe strong threshold electron signals, which are due to detachment, by the second photon, of highly rotationally excited anions resulted from the decay of the DBS. On the other hand, in the R2PD spectrum of 4CP – we observe well-resolved vibrational peaks due to the three lowest-frequency vibrational modes of 4CP – , which are populated from the decay of the QBS. Here, the different behaviors of the R2PD spectra suggest unexpected differences between the relaxation mechanisms of the dipole-bound and quadrupole-bound excited states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissociative electron recombination and rotational cooling of the deuterated triatomic hydrogen ions H 2 ⁡D + and D 2 ⁢H +

We have measured the dissociative recombination (DR) of the deuterated triatomic hydrogen ions H 2 ⁡D + and D 2 ⁢H + as a function of storage time at the Cryogenic Storage Ring (CSR). Both molecular ions were stored for up to 1000 s inside the cryogenic vacuum of the CSR prior to the electron recombination measurements, allowing them to cool to their lowest rotational states. We implement a comprehensive model for all relevant processes to predict the internal state evolution of the ions during storage inside the CSR, employing calculated radiative transition strengths and state-selective rate coefficients for electron collisions. Our DR rate coefficient measurements with deuterated triatomic hydrogen ions in defined quantum states allow for meaningful comparisons with state-of-the-art theoretical calculations, paving the way for a better understanding of the complex DR process for polyatomic molecular ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗