Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Toward fusion plasma scenario planning for NSTX-U using machine-learning-accelerated models

One of the most promising devices for realizing power production through nuclear fusion is the tokamak. To maximize performance, it is preferable that tokamak reactors achieve advanced operating scenarios characterized by good plasma confinement, improved magnetohydrodynamic (MHD) stability, and a largely non-inductively driven plasma current. Such scenarios could enable steady-state reactor operation with high \emph{fusion gain} --- the ratio of produced fusion power to the external power provided through the plasma boundary. Precise and robust control of the evolution of the plasma boundary shape as well as the spatial distribution of the plasma current, density, temperature, and rotation will be essential to achieving and maintaining such scenarios. The complexity of the evolution of tokamak plasmas, arising due to nonlinearities and coupling between various parameters, motivates the use of model-based control algorithms that can account for the system dynamics. In this work, a learning-based accelerated model trained on data from the National Spherical Torus Experiment Upgrade (NSTX-U) is employed to develop planning and control strategies for regulating the density and temperature profile evolution around desired trajectories. The proposed model combines empirical scaling laws developed across multiple devices with neural networks trained on empirical data from NSTX-U and a database of first-principles-based computationally intensive simulations. The reduced execution time of the accelerated model will enable practical application of optimization algorithms and reinforcement learning approaches for scenario planning and control development. An initial demonstration of applying optimization approaches to the learning-based model is presented, including a strategy for mitigating the effect of leaving the finite validity range of the accelerated model. The approach shows promise for actuator planning between experiments and in real-time.

machine learning↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services: Preprint

This paper develops a hierarchical control fram-ework to aggregate and control behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. Even though the increasing penetration of DERs will strain the power networks in terms of voltage regul-ation and coordination issues with existing transmission-level conventional generators, the distribution-level DERs can also be utilized to help provide flexibility to the power network while providing cost savings to the DER owners. Therefore, this paper develops a model-predictive control strategy to determine the available power flexibility, and to utilize the flexibility in an aggregated form to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

14 SOLAR ENERGY↗

Development of real-time density feedback control on MAST-U in L-mode

In this paper we report on the development and demonstration of density feedback control for MAST-U. Sinusoidal perturbations are used to measure the frequency response from a deuterium gas valve (actuator) to line-integrated core electron density measured by the interferometer (sensor). In the frequency range relevant for control design, only two system-identification experiments were needed to regress a first-order dynamic model. This control-oriented model informs the offline design of a proportional integral controller with the established loop-shaping controller design method. After offline verification of the controller implementation, control is demonstrated by experimentally tracking a staircase reference for the line-integrated electron density. This paper demonstrates the efficiency of controller design using system-identification and loop-shaping, providing reliable density control for MAST-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive Time Step Control for Multirate Infinitesimal Methods

Multirate methods have been used for decades to temporally evolve initial-value problems in which different components evolve on distinct time scales, and thus use of different step sizes for these components can result in increased computational efficiency. Generally, such methods select these different step sizes based on experimentation or stability considerations. For problems that evolve on a single time scale, adaptivity approaches that strive to control local temporal error are widely used to achieve numerical results of a desired accuracy with minimal computational effort, while alleviating the need for manual experimentation with different time step sizes. However, there is a notable gap in the publication record on the development of adaptive time step controllers for multirate methods. In this paper, we extend the single-rate controller work of Gustafsson [ACM Trans. Math. Software, 20 (1994), pp. 496-517] to the multirate method setting. Specifically, we develop controllers based on polynomial approximations to the principal error functions for both the "fast" and "slow" time scales within multirate infinitesimal (MRI) methods. We additionally investigate a variety of approaches for estimating the errors arising from each time scale within MRI methods. We then numerically evaluate the proposed multirate controllers and error estimation strategies on a range of multirate test problems, comparing their performance against an estimated optimal performance. Through this work, we combine the most performant of these approaches to arrive at a set of multirate adaptive time step controllers that robustly achieve desired solution accuracy with minimal computational effort.

97 MATHEMATICS AND COMPUTING↗

Controls Optimization Final Report, Controls Algorithms Report, Control Optimization - SPA II: Heaving Buoy Test Results [Three reports]

The over-arching project objective is to fully develop and validate optimal controls frameworks that can subsequently be applied widely to different WEC devices and concepts. Optimal controls of WEC devices represent a fundamental building block for WEC designers that must be considered as an integral part of every stage of device development. Using a building-blocks approach to optimal controls development, this effort will result in the full development of a feed-forward and feed-back control approach and a wave prediction system. Phase I focused primarily on numerical offline optimization and validation using wave tank testing of three industry partners’ WEC devices, including; CalWave, Ocean Energy, and Resolute Marine Energy. These industry partnerships allowed us to identify optimal control strategies for these different WEC topologies at different maturity levels. Phase II focused on demonstrating an integrated control system on an at-sea prototype that is to be custom-built and maturing the HW and SW required to successfully run our advanced controls code frameworks on at-sea systems. A secondary focus during phase II is to adapt our systems identification, controls and wave-prediction frameworks to become more robust and comprehensive in respect to RT capability, robustness, and reliability.

16 TIDAL AND WAVE POWER↗

Fabrication of porous transport electrodes: Development of quantitative approach for quality control

This work focuses on porous transport electrodes (PTEs), which integrate the anodic catalyst with the adjacent Ti porous transport layer (PTL). Challenges in catalyst deposition on PTLs, particularly at low loadings, motivated this study to evaluate various fabrication methods and characterization approaches. This work investigated Pt-treated PTLs coated with Ir-based catalysts using several common methods, including airbrush coating, rod coating, ultrasonic spray coating, electrodeposition, and sputter deposition, with catalyst loadings ranging from 2.9 to 0.1 mg/cm 2 , providing the opportunity for comparisons across a large set of samples produced by different methods. Two widely accessible characterization techniques: X-ray computed tomography (XCT) and scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDS) were explored. Initial evaluation of selected samples with XCT provided qualitative insights into catalyst distribution, however comprehensive quantitative analysis was limited. SEM-EDS enabled detailed information on the catalyst distribution both qualitatively and quantitatively using two metrics. Atomic and surface area % ratios of Pt:Ir and Ti:Ir revealed trends in catalyst loading and losses into the PTL pores, as well as evaluating the homogeneity of catalyst coatings. The analysis demonstrated that ultrasonic spray coating, electrodeposition, and sputter coating produced the most homogeneous coatings, with minimal catalyst losses observed for electrodeposition and sputter coating. By adapting common techniques with novel, standardized methodologies, this work establishes a universally applicable framework for cross-study comparison of PTEs. The SEM-EDS approach provides a practical, accessible tool for PTE characterization and contributes a reference dataset supporting both research development and rapid quality control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-based real-time surface heat flux and temperature estimation for the DIII-D tokamak

A control-oriented model for monitoring of wall power flux densities on the DIII-D tokamak has been successfully implemented and validated experimentally. Future reactors will have to withstand severe steady state high heat flux loads on plasma-facing components (PFCs). Due to the difficulty of directly-measuring local heat fluxes on these components, monitoring and protection of PFCs during the plasma discharge can benefit from simplified physics-based real-time (RT) functional models to estimate and guide heat load control. As a first step into the development, a control-oriented model for monitoring of wall power flux densities and temperatures on DIII-D tokamak has been successfully implemented. The paper discusses the experimental demonstration and comparison of the 2-D model-based wall heat flux algorithm on the DIII-Dinner wall limiter (IWL) against infra-red camera heat flux measurements for limited plasma configurations. The paper also reports on the benchmarking of the field line tracing environment, SMITER, developed at ITER organization on DIII-D tokamak against experimental IR diagnostic data and the derivation of the component shaping weighting factors for the 2-D model-based approach. Here, the extension of the model-based approach for surface temperature estimation on the DIII-D IWL is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating Nuclear Facility Mission Completion Through an Improved Chemical Hazard Control Strategy - 20460

Code of Federal Regulation (CFR) 10 CFR 830, Nuclear Safety Management [1], explicitly identifies hazardous materials in addition to radioactive materials when establishing the scope of materials that must be evaluated in Hazard Category (HC) 1, 2, and 3 nuclear facilities. This inclusion has led to a near decade-long progression of more and more rigorous application of chemical hazard controls in these facilities. The progressive addition of more rigorous chemical hazard controls has occurred across the Department of Energy (DOE) Complex, having been driven by contractors and regulators alike. However, chemical hazards in other DOE facilities have been, and continue to be, controlled using traditional industrial safety centered strategies. Thus, identical chemical hazards are controlled using dramatically different approaches based solely on the facility type. Not only are the controls different, the analysis and derivation rigor and requirements are also significantly different. In particular, chemical control derivation and application in non-nuclear facilities are much less onerous than the comprehensive hazard analysis process used in nuclear facilities, even in circumstances in which chemicals are not initiators to, or do not exacerbate a nuclear event. While the derivation and control approaches used in these two types of facilities are disparate, the safety results are similarly effective based on a review of reported chemical events from 2014 through 2018. While both approaches achieve comparable safety outcomes, the approach used in nuclear facilities results in significantly greater preparation costs and implementation costs. Furthermore, the problem with the differing approach is not relegated to the control preparation and implementation burden. The operational impact of potentially unnecessary controls slows mission completion without a corresponding increase in safety, not to mention the dilution of the importance of Technical Safety Requirements. The proposed solution must first include a critical and thorough examination of DOE Complex and top-tier chemical industry chemical hazard control practices, coupled with a similar examination of the driving facility regulatory requirements. Results from the examination can then be used to fuel a bold departure from current chemical control practices in Hazard Category 1, 2, and 3 nuclear facilities. Development of an improved and consistent chemical hazard control process would follow, one that continues to ensure safety while accelerating mission completion and significantly reducing the burden associated with chemical hazard control development and implementation. The improved process must establish a hierarchy where radiological hazards are addressed using safety class and safety significant controls and chemical hazards are addressed using overarching safety management programs (with limited unique exceptions). The improved Hazard Category 1,2, and 3 nuclear facility chemical hazard control strategy, while compliant with 10 CFR 830 [1], would be founded on the requirements in 10 CFR 851, Worker Safety and Health Program [2], and the complementary DOE O 151.1D, Comprehensive Emergency Management System [3]. In this way, the Hazard Category 1, 2, and 3 nuclear facility chemical hazard control strategy would, wherever appropriate, be the same process used at other DOE Complex facilities. Ultimately, the improved process will maintain safety and significantly reduce costs and life cycle risk through faster mission completion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Citadels Final Report (GMLC 2.2.1: Citadels)

This is the final project report for the Grid Modernization Laboratory Consortium (GMLC) Resilient Distribution System (RDS) Citadels project. The primary goal of this GMLC project was to increase the operational flexibly of power systems by engaging microgrids distributedly, coordinated using consensus algorithms. The primary goal was successfully achieved. The primary goal was divided into three areas: Implement peer-to-peer control between microgrid controllers using the Open Field Message Bus (OpenFMB) approach; Develop and implement consensus algorithms on commercially available hardware that allows a group of microgrids to distributedly implement operational controls; Develop the architectures and controls to enable groups of microgrids to coordinate their operations to support the bulk power system during abnormal events, and end-use loads in the event the bulk power systems fail.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Pressure Rail System Design with Variable Pressure Control Strategy

This paper presents the design and the control method of a Multiple Pressure Rail system (MPR) with a variable pressure control logic that allows minimization of throttling loss, therefore, increasing the overall fluid power actuation efficiency. An MPR system allows controlling hydraulic actuators with a pressure control logic, as opposed to traditional flow control logics which are well established in mobile applications. A proper setting of the number of pressure rails and the pressure level in each rail permits optimizing the system efficiency of an MPR solution. MPR systems have been recently proposed with different purposes, but seldom adopt variable pressure control strategies to manage the pressure variations in the rails. Moreover, the related past work attempts to maximize the energy recovery during overrunning load conditions. This paper, instead, addresses the case of an MPR system that handles a multitude of hydraulic functions without significant overrunning loads, as it occurs in many mobile applications such as in agriculture. The paper first presents the design alternatives considered for the MPR system, including the supply, the control valves, and the controller. Second, a dedicated test rig is developed to support experimental activities and validations of a lumped parameter model developed within this research to develop the MPR control strategy. The results describe the operating features of the proposed MPR solution. By considering the case of a traditional LS system, the paper results also show how system efficiency can be highly improved, with energy savings in the order of 49%

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Validation of Home Comfort System for Total Performance Deficiency/Fault Detection and Optimal Comfort Control

In this project, we developed and tested a learning-based home thermal model that facilitates the operation of a model predictive control (MPC)-based optimization agent and an automated fault detection and diagnosis (AFDD) agent. The home thermal model was constructed using a two-node resistor-capacitor model. Moreover, two accompanying parameter identification methods were introduced, least-squares and optimization. Based on the home thermal model, the MPC-based optimization agent was developed to optimize residential HVAC operation. Using two FDD methods, the AFDD agent was constructed to detect and diagnose two prevalent residential AC faults, airflow reduction and refrigerant undercharge. The home thermal model, along with the MPC-based optimization agent and AFDD agent, were tested at the Norman Test House, Miami Test House, Pacific Northwest National Laboratory (PNNL) Test House A, and PNNL Test House B. Finally, they were also field tested in nine demonstration homes with real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemical compositions, pharmacological activities, quality control studies of Erycibes plants, and the development of their substitutes

Erycibes are members of the Convolvulaceae family, including more than 10 species worldwide that are distributed in tropical Asia. Some Erycibes species have long been used as traditional remedies for rheumatoid arthritis, fever, hepatitis, and liver injury in China and Thailand. A total of 152 compounds from Erycibes plants have been isolated and identified, categorized as flavonoids, coumarins, quinic acid derivatives, lignans, and alkaloids. Coumarins are the characteristic and active constituents of this species, including scopoletin and scopolin. Modern pharmacological studies have shown that the extracts and bioactive components of Erycibes plants exhibit several biological activities, including antiinflammatory, analgesic, hepatoprotective, anti‐gout, antitumor, antioxidation, and other therapeutic effects. However, in recent years, due to destructive exploitation and utilization, some Erycibes plants' natural resources have become rare or endangered. Developing substitutes is a strategy to alleviate the pressure on those endangered medicinal plant resources. To provide a scientific basis for the development and protection of those threatened Erycibes species, this review summarized the current status of the chemical compositions, pharmacological activities, quality control studies, and the development of substitutes for Erycibes plants. In particular, the rationale for use of Porana sinensis currently on the market is discussed.

Peng, Yu↗

Leveraging Real-World Driving Data for Design and Impact Evaluation of Energy Efficient Control Strategies

Modeling and simulation are crucial in the development of advanced energy efficient control strategies. Utilizing real-world driving data as the underlying basis for control design and simulation lends veracity to projected real-world energy savings. Standardized drive cycles are limited in their utility for evaluating advanced driving strategies that utilize connectivity and on-vehicle sensing, primarily because they are typically intended for evaluating emissions and fuel economy under controlled conditions. Real-world driving data, because of its scale, is a useful representation of various road types, driving styles, and driving environments. The scale of real-world data also presents challenges in effectively using it in simulations. A fast and efficient simulation methodology is necessary to handle the large number of simulations performed for design analysis and impact evaluation of control strategies. In this study, two methods are presented of leveraging real-world data in both design optimization of energy efficient control strategies and in evaluating the real-world impact of those control strategies upon large-scale deployment. Through these methodologies, strategies with highest impact on energy savings were selected to be implemented as control algorithms. The developed algorithms were incorporated into a vehicle dynamics and powertrain control architecture implemented on a Cadillac CT6 demonstration vehicle. The control algorithms were then exercised on real-world driving scenarios to determine their impact on collective energy savings. The methodology utilizes the large-scale driving data sets maintained by the National Renewable Energy Laboratory to extract real-world driving scenarios and efficient simulation software tools. The insights obtained through this research help in guiding technology selection for energy efficient driving controls.

ARPA-E↗

Developing a Hybrid Electric Vehicle Eco-Cooperative Adaptive Cruise Control System at Signalized Intersections.

This study develops an eco-driving strategy for hybrid electric vehicles (HEVs) in the vicinity of signalized intersections, entitled HEV Eco-Cooperative Adaptive Cruise Control at Intersections (Eco-CACC-I). The proposed system computes real-time, energy-optimized vehicle trajectories using HEV vehicle dynamics and energy consumption models. In the proposed system, a simple HEV energy model is used to compute the instantaneous fuel consumption. This HEV energy model is selected since it is general, transferable, and can be easily used to compute instantaneous energy consumption levels for HEVs without the additional input of vehicle engine data or complicated power control strategies. In addition, a vehicle dynamics model is used to capture the relationship between speed, acceleration level, and tractive/resistance forces on vehicles. The energy-optimum problem is formulated as an optimization problem with constraints, which is solved using a moving-horizon dynamic programming approach. The proposed HEV Eco-CACC-I system was tested to evaluate its performance for various speed limits, roadway grades, and signal timings. Lastly, the proposed HEV controller was implemented in a microscopic traffic simulation software to test its network-wide performance. The test results from an arterial corridor with three signalized intersections demonstrate that the proposed system can effectively reduce stop-and-go traffic in the vicinity of signalized intersections producing savings of 7.4% in energy consumption, 5.8% in traffic delay and 23% vehicle stops, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗