Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Geometric surprises in the Python's lunch conjecture

A bulge surface, on a time reflection-symmetric Cauchy slice of a holographic spacetime, is a non-minimal extremal surface that occurs between two locally minimal surfaces homologous to a given boundary region. According to the python’s lunch conjecture of Brown et al., the bulge’s area controls the complexity of bulk reconstruction, in the sense of the amount of post-selection that needs to be overcome for the reconstruction of the entanglement wedge beyond the outermost extremal surface. We study the geometry of bulges in a variety of classical spacetimes, and discover a number of surprising features that distinguish them from more familiar extremal surfaces such as Ryu-Takayanagi surfaces: they spontaneously break spatial isometries, both continuous and discrete; they are sensitive to the choice of boundary infrared regulator; they can self-intersect; and they probe entanglement shadows, orbifold singularities, and compact spaces such as the sphere in AdS _p× S^q p × S q . These features imply, according to the python’s lunch conjecture, novel qualitative differences between complexity and entanglement in the holographic context. We also find, surprisingly, that extended black brane interiors have a non-extensive complexity; similarly, for multi-boundary wormhole states, the complexity pleateaus after a certain number of boundaries have been included.

Physics↗

Post-Fukushima Research and Development Strategy for MELCOR

Numerous MELCOR modeling improvements and analyses have been performed in the time since the severe accidents at Fukushima Daiichi Nuclear Power Station that occurred in March 2011. This report briefly summarizes the related accident reconstruction and uncertainty analysis efforts. It further discusses a number of potential pursuits to further advance MELCOR modeling and analysis of the severe accidents at Fukushima Daiichi and severe accident modeling in general. Proposed paths forward include further enhancements to identified MELCOR models primarily impacting core degradation calculations, and continued application of uncertainty analysis methods to improve model performance and a develop deeper understanding of severe accident progression.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PROJECTION EFFECTS IN CORONAL DIMMINGS AND ASSOCIATED EUV WAVE EVENT

We investigate the high-speed ( v > 1000 km s{sup −1}) extreme-ultraviolet (EUV) wave associated with an X1.2 flare and coronal mass ejection (CME) from NOAA active region 11283 on 2011 September 6 (SOL2011-09-06T22:12). This EUV wave features peculiar on-disk signatures; in particular, we observe an intermittent “disappearance” of the front for 120 s in Solar Dynamics Observatory ( SDO )/AIA 171, 193, 211 Å data, whereas the 335 Å filter, sensitive to hotter plasmas ( T ∼ 2.5 MK), shows a continuous evolution of the wave front. The eruption was also accompanied by localized coronal dimming regions. We exploit the multi-point quadrature position of SDO and STEREO-A , to make a thorough analysis of the EUV wave evolution, with respect to its kinematics and amplitude evolution and reconstruct the SDO line-of-sight (LOS) direction of the identified coronal dimming regions in STEREO-A . We show that the observed intensities of the dimming regions in SDO /AIA depend on the structures that are lying along their LOS and are the combination of their individual intensities, e.g., the expanding CME body, the enhanced EUV wave, and the CME front. In this context, we conclude that the intermittent disappearance of the EUV wave in the AIA 171, 193, and 211 Å filters, which are channels sensitive to plasma with temperatures below ∼2 MK is also caused by such LOS integration effects. These observations clearly demonstrate that single-view image data provide us with limited insight to correctly interpret coronal features.

79 ASTRONOMY AND ASTROPHYSICS↗

The Importance of Dosimetry Standardization in Radiobiology

Radiation dose is central to much of radiobiological research. Precision and accuracy of dose measurements and reporting of the measurement details should be sufficient to allow the work to be interpreted and repeated and to allow valid comparisons to be made, both in the same laboratory and by other laboratories. Despite this, a careful reading of published manuscripts suggests that measurement and reporting of radiation dosimetry and setup for radiobiology research is frequently inadequate, thus undermining the reliability and reproducibility of the findings. To address these problems and propose a course of action, the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Diseases (NIAID), and the National Institute of Standards and Technology (NIST) brought together representatives of the radiobiology and radiation physics communities in a workshop in September, 2011. The workshop participants arrived at a number of specific recommendations as enumerated in this paper and they expressed the desirability of creating dosimetry standard operating procedures (SOPs) for cell culture and for small and large animal experiments. It was also felt that these SOPs would be most useful if they are made widely available through mechanism(s) such as the web, where they can provide guidance to both radiobiologists and radiation physicists, be cited in publications, and be updated as the field and needs evolve. Other broad areas covered were the need for continuing education through tutorials at national conferences, and for journals to establish standards for reporting dosimetry. This workshop did not address issues of dosimetry for studies involving radiation focused at the sub-cellular level, internally-administered radionuclides, biodosimetry based on biological markers of radiation exposure, or dose reconstruction for epidemiological studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wavelet Analyses of F/A-18 Aeroelastic and Aeroservoelastic Flight Test Data

Time-frequency signal representations combined with subspace identification methods were used to analyze aeroelastic flight data from the F/A-18 Systems Research Aircraft (SRA) and aeroservoelastic data from the F/A-18 High Alpha Research Vehicle (HARV). The F/A-18 SRA data were produced from a wingtip excitation system that generated linear frequency chirps and logarithmic sweeps. HARV data were acquired from digital Schroeder-phased and sinc pulse excitation signals to actuator commands. Nondilated continuous Morlet wavelets implemented as a filter bank were chosen for the time-frequency analysis to eliminate phase distortion as it occurs with sliding window discrete Fourier transform techniques. Wavelet coefficients were filtered to reduce effects of noise and nonlinear distortions identically in all inputs and outputs. Cleaned reconstructed time domain signals were used to compute improved transfer functions. Time and frequency domain subspace identification methods were applied to enhanced reconstructed time domain data and improved transfer functions, respectively. Time domain subspace performed poorly, even with the enhanced data, compared with frequency domain techniques. A frequency domain subspace method is shown to produce better results with the data processed using the Morlet time-frequency technique.

Martin J Brenner↗

Detection of Missing Assemblies and Estimation of the Scattering Densities in a VSC-24 Dry Storage Cask with Cosmic-Ray-Muon-Based Computed Tomography

We report that highly energetic, cosmic-ray muons can penetrate a dry storage cask and yield information about the material inside it by making use of the physics of multiple Coulomb scattering. Work by others has shown this information may be used for verification of dry storage cask contents after continuity of knowledge has been lost. In our modeling and simulation approach, we use ideal planar radiation detectors to record the trajectories and momentum of both incident and exiting cosmic ray muons; this choice allows us to demonstrate the fundamental limit of the technology for a particular measurement and reconstruction method. In a method analogous to computed tomography with the attenuation coefficient replaced by scattering density, we apply a filtered back projection algorithm in order to reconstruct the geometry in modeled scenarios for a VSC-24 concrete-walled cask. We also report on our attempt to estimate material-specific information. A scenario where one of the middle four spent nuclear fuel assemblies is missing—undetectable with a simple PoCA-based approach—is expected to be detectable with a CT-based approach. Moreover, a trickier scenario where one or more assemblies is replaced by a dummy assembly is put forward. Lastly, in this case, we expect that this dry storage cask should be found to be not as declared based on our simulation and reconstruction results.

36 MATERIALS SCIENCE↗

Advancing Supersonic Retropropulsion Using Mars-Relevant Flight Data: An Overview

Advanced robotic and human missions to Mars require landed masses well in excess of current capabilities. One approach to safely land these large payloads on the Martian surface is to extend the propulsive capability currently required during subsonic descent to supersonic initiation velocities. However, until recently, no rocket engine had ever been fired into an opposing supersonic freestream. In September 2013, SpaceX performed the first supersonic retropropulsion (SRP) maneuver to decelerate the entry of the first stage of their Falcon 9 rocket. Since that flight, SpaceX has continued to perform SRP for the reentry of their vehicle first stage, having completed multiple SRP events in Mars-relevant conditions in July 2017. In FY 2014, NASA and SpaceX formed a three-year public-private partnership centered upon SRP data analysis. These activities focused on flight reconstruction, CFD analysis, a visual and infrared imagery campaign, and Mars EDL design analysis. This paper provides an overview of these activities undertaken to advance the technology readiness of Mars SRP.

Braun, Robert D.↗

Advancing Supersonic Retropropulsion Using Mars-Relevant Flight Data: An Overview

Advanced robotic and human missions to Mars require landed masses well in excess of current capabilities. One approach to safely land these large payloads on the Martian surface is to extend the propulsive capability currently required during subsonic descent to supersonic initiation velocities. However, until recently, no rocket engine had ever been fired into an opposing supersonic freestream. In September 2013, SpaceX performed the first supersonic retropropulsion (SRP) maneuver to decelerate the entry of the first stage of their Falcon 9 rocket. Since that flight, SpaceX has continued to perform SRP for the reentry of their vehicle first stage, having completed multiple SRP events in Mars-relevant conditions in July 2017. In FY 2014, NASA and SpaceX formed a three-year public-private partnership centered upon SRP data analysis. These activities focused on flight reconstruction, CFD analysis, a visual and infrared imagery campaign, and Mars EDL design analysis. This paper provides an overview of these activities undertaken to advance the technology readiness of Mars SRP.

Braun, Robert D.↗

Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, less EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporal forecasting of the edge localized modes in tokamak plasmas using neural networks

Artificial intelligence techniques have been increasingly adopted by the plasma and fusion science to address problems like plasma reconstruction, surrogate modeling, and tokamak/stellarator optimization. A key focus in sustained fusion research is the prediction and mitigation of edge-localized-modes (ELMs), instabilities that occur in short, periodic bursts and can cause erosion to the tokamak vessel wall. Recent research has demonstrated the power of neural networks in approximating continuous functions. In this work, we build spatiotemporal forecasting models that can predict the onset of ELMs and their evolution at early stages. We leverage recent advances in generative modeling, sequence-to-sequence modeling, and Fourier neural operators to propose architectures and training strategies that can learn to forecast short to long term dynamics of the noisy signals due to ELMs. We benchmark the developed model against a state-of-the-art foundation model using the beam emission spectroscopy (BES) data that captures the plasma fluctuations due to ELMs over a 8 x 8 spatial grid. Our models demonstrate high accuracy, outperforming the baselines, in predicting the evolution of BES signals during ELM events. Furthermore, the developed models exhibit high accuracy in predicting the rapid rise and relaxation of the signals due to ELMs within 30–80 µs.

edge localized modes↗

TU-A-18A-01: Basic Principles of PET/CT, Calibration Methods and Contrast Recovery Across Multiple Cameras

This continuing education session will discuss the physical principles of PET/CT imaging and characterization of contrast recovery using accreditation phantoms. A detailed overview will be given on the physical principles of PET including positron decay physics, 2D and 3D data acquisition, time-of-flight, scatter correction, CT attenuation correction, and image reconstruction. Instrument quality control and calibration procedures will be discussed. Technical challenges, common image artifacts and strategies to mitigate these issues will also be discussed. Data will be presented on acquisition techniques and reconstruction parameters affecting contrast recovery. The discussion will emphasize the minimization of reconstruction differences in quantification metrics such as SUV and contrast recovery coefficients for the NEMA and ACR clinical trial phantoms. Data from new and older generation scanners will be shown including comparison of contrast recovery measurements to their analytical solutions. The goal of this session is to update attendees on the quality control and calibration of PET/CT scanners, on methods to establish a common calibration for PET/CT scanners to control for instrument variance across multiple sites. Learning Objectives: Review the physical principles of PET/CT, quality control and calibration Gain further understanding on how to apply techniques for improving quantitative agreement across multiple cameras Describe the differences between measured and expected contrast recovery for the NEMA and ACR PET phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mathematical Morphological Filtering with a Self-Adaptive Reconstruction Technique and Application to Local Seismic Data

Recorded seismic data are generally contaminated by noise from different sources, which masks the signals of interest. In the seismology community, frequency filtering (FF) is the standard method for noise suppression. However, when the signal of interest and noise share the same frequency band, the latter cannot be filtered out without infringing on the former. We implemented a noise suppression approach based on the mathematical morphology theorem. The method involves compound operations of dilation and erosion using structuring elements of varying lengths and decomposes an input noisy waveform into several time functions with differing characteristics. Further, the filtered waveform is constructed from the time functions using a self-adaptive reconstruction technique. Application to a data set of >4700 local waveforms suggests that the implemented mathematical morphological filtering (MMF) approach is efficient for data with low signal-to-noise ratio (SNR) and significantly outperforms FF in that SNR range. For most of the dataset, FF, machine learning (ML) denoising, and continuous wavelet transform (CWT) thresholding result in higher SNR values compared with the MMF method. However, for ~42% of the waveforms, MMF outperforms FF, and the SNR gain achieved with MMF is as large as ~23 dB. Compared to ML denoising and CWT thresholding, this proportion drops to only ~10%–14%. Our results suggests that in an operational setting, MMF cannot replace the other noise suppression methods; however, signal detection can be improved if MMF is used to supplement them in some scenarios. MMF could help detect signals in problematic low-SNR data, which are currently being missed particularly when using FF alone.

58 GEOSCIENCES↗

Long-slit Spectra of the Red Rectangle at 3 Microns

We have observed the Red Rectangle with the Cryogenic Spectrometer (CRSP) at the 2.1 m telescope of Kitt Peak National Observatory. The Red Rectangle is a well-known source of the infrared emission features associated with polycyclic aromatic hydrocarbons (PAHs). Our long-slit spectra cover the 3.2-3.6 micrometer regime, which includes the strong PAH band at 3.29 micrometers, a weaker component at 3.40 micrometers, and an emission plateau which continues out to 3.6 micrometers. Emission in the PAH bands extends several arcseconds to the north and south of the central source (HD 44179). The seeing during our observations was approximately 1.5 arcseconds, but we have deconvolved the point spread function from our spectral images at each wavelength using maximum entropy reconstruction, allowing us to examine the relative behavior of these emission components at finer spatial scales. With the new 256x256 array installed on CRSP, each pixel covers 0.6 arcseconds of sky. Our reconstructions reveal that the strength of the small 3.4 micrometer emission feature increases with respect to the 3.3 micrometer feature as the distance from the central source increases. In particular, there appears to be a region of enhanced 3.4 micrometer emission roughly 3" to the north and south of the central source. We are analyzing our results in terms of the competing models for the origin of the 3.4 micrometer emission feature, which could be a vibrational overtone of the 3.3 micrometer feature, or could result from the attachment of molecular sidegroups to the PAH molecule.

Sloan, G. C.↗

The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

The balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approximately 20 keV to greater than approximately 10 MeV. GRIPS will address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution of less than 0.1 cubic millimeter. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-centimeter thick tungsten alloy slit/slat grid with pitches that range quasi-continuously from 1 to 13 millimeters. The MPRM is situated 8 meters from the spectrometer to provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e., as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS is scheduled for a continental-US engineering test flight in fall 2013, followed by long or ultra-long duration balloon flights in Antarctica.

Shih, Albert Y.↗

Fermi Large Area Telescope Operations: Progress Over 4 Years

The Fermi Gamma-ray Space Telescope was launched into orbit in June 2008, and is conducting a multi-year gamma-ray all-sky survey, using the main instrument on Fermi, the Large Area Telescope (LAT). Fermi began its science mission in August 2008, and has now been operating for almost 4 years. The SLAC National Accelerator Laboratory hosts the LAT Instrument Science Operations Center (ISOC), which supports the operation of the LAT in conjunction with the Mission Operations Center (MOC) and the Fermi Science Support Center (FSSC), both at NASA's Goddard Space Flight Center. The LAT has a continuous output data rate of about 1.5 Mbits per second, and data from the LAT are stored on Fermi and transmitted to the ground through TDRS and the MOC to the ISOC about 10 times per day. Several hundred computers at SLAC are used to process LAT data to perform event reconstruction, and gamma-ray photon data are subsequently delivered to the FSSC for public release with a few hours of being detected by the LAT. We summarize the current status of the LAT, and the evolution of the data processing and monitoring performed by the ISOC during the first 4 years of the Fermi mission, together with future plans for further changes to detected event data processing and instrument operations and monitoring.

43 PARTICLE ACCELERATORS↗

Use of Electrical Imaging and Distributed Temperature Sensing Methods to Characterize Surface Water-Groundwater Exchange Regulating Uranium Transport at the Hanford 300 Area, Washington

A critical challenge in advancing prediction of solute transport between contaminated aquifers and rivers is improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along river corridors. Here, we explored the use of waterborne geoelectrical imaging, in conjunction with fiber-optic distributed temperature sensor (DTS) monitoring, to improve the conceptual model for uranium transport within the hyporheic corridor at the Hanford 300 Area. We first inverted waterborne geoelectrical (resistivity and induced polarization) datasets for distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units was reconstructed. Variations in the depth to the interface between the overlying coarse-grained, high permeability Hanford formation and the underlying finer-grained, less permeable Ringold formation, an important contact that limits vertical migration of contaminants, were resolved along ~3 km of the river corridor centered on the 300 Area. Polarizability images were translated into lithologic images using established relationships between polarizability and surface area normalized to pore volume (Spor). The spatial variability captured in the geoelectrical datasets indicates that previous studies based on borehole projections and point probing overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. The DTS data recorded on 1. 5 km of cable with a 1 m spatial resolution and 5 minute sampling interval revealed sub-reaches showing (1) high temperature anomalies and, (2) a strong negative correlation between temperature and river stage, both indicative of groundwater influxes during winter months. The DTS datasets confirm the hydrologic significance of the variability identified in the geoelectrical imaging and reveal a pattern of highly focused hyporheic exchange, with exchange concentrated at springs where the Hanford formation is thick, and coinciding with a paleochannel identified in ground penetrating radar surveys at one location. No evidence for focused hyporheic exchange is observed in the DTS data where the Ringold unit is in contact with the riverbed. Our findings illustrate how the combination of waterborne geoelectrical imaging and DTS technologies can characterize hyporheic exchange in a complex, coupled river-aquifer system.

300 area↗

Aerosol Profile Retrievals from Integrated Dual Wavelengths Space Lidar ESSP3-CENA and Spectral Radiance MODIS Data

The ESSP3-CENA space mission (formally PICASSO-CENA) will provide continues global observations with a two wavelength lidar. The attenuated backscattering coefficients measured by the lidar, have valuable information about the vertical distribution of aerosol particles and their sizes. However the information cannot be mapped into unique aerosol physical properties. Infinite number of physical solutions with different attenuations through the atmosphere can reconstruct the same two wavelength backscattered profile measured from space. Spectral radiance measured by MODIS simultaneously with the ESSP3 data can constrain the problem and resolve this ambiguity to a large extent. Sensitivity study shows that inversion of the integrated MODIS+ESSP3 data can derive the vertical profiles of the fine and coarse modes mixed in the same atmospheric column in the presence of moderate calibration uncertainties and electronic noise (approx. 10%). We shall present the sensitivity study and results from application of the technique to measurements in the SAFARI-2000 and SHADE experiments.

Kaufman, Yoram↗

Status of the Project 8 Phase II

The Project 8 collaboration aims to measure the absolute neutrino mass scale using cyclotron radiation emission spectroscopy on the beta decay of tritium. The second phase of the project will measure a continuous spectrum of molecular tritium beta decays and extract the tritium endpoint value with an eV or sub-eV scale precision. Monoenergetic electrons emitted by gaseous $^{83\mathrm{m}}$Kr atoms are used to determine the relationship between cyclotron frequency and electron energy. This study allows us to optimize both the event reconstruction algorithm and the hardware configuration, in preparation for measuring the tritium beta decay spectrum. Phase II will benefit from a gas system of krypton and tritium that will allow measurement and offline correction for magnetic field fluctuations. We present the recent progress in understanding the electron kinematics and implementing the magnetic field calibration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗