Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power-Conserving Stepping-Motor Drive Circuits

Two improved drive circuits for sinusoidally commutated stepping motor include feedback loops reducing unnecessary consumption of power by reducing drive-current amplitude, I, when motor operates under light load. Basic design strategy attempts to supply only little more current than minimum needed to overcome friction in lightly loaded condition. In this sinusoidally commutated two-phase stepping motor, magnetic field generated by drive currents in phase-A and phase-B stator windings urges rotor toward commanded angle x.

Nola, Frank J.↗

Conservative buffering of approximate nonlinear constraints

In engineering design practice behavior is usually predicted based on some known nominal design. However, when the design is fabricated it will differ from the nominal design because of manufacturing tolerances. In order to generate nominal designs that will still satisfy behavior constraints in the presence of manufacturing tolerances, engineers resort to the use of safety factors, over and above those introduced to account for other uncertainties (e.g., in load conditions, material properties, analysis modeling). The accurate selection of the values of these manufacturing tolerances safety factors is dependent on the capability of the engineer to determine the sensitivity of the critical constraints to changes in the design variables. This process usually leads to overly conservative designs. The task of choosing safety factors is much more difficult in structural synthesis because: (1) it is not known which constraints will be active at the final design, (2) as the design changes during the synthesis process the sensitivities of the constraints with respect to the design variables also change, and (3) the imposition of the safety factors themselves may change the set of critical constraints. These difficulties can be overcome with the approximation concepts approach to structural synthesis by buffering the approximate constraints with quantities that are related to the design variable tolerances and the accurate sensitivities of the constraints with respect to the design variable. Designs generated by this approach tend to be feasible but not overly conservative.

Thomas, H. L.↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulating dispatchable grid services provided by flexible building loads: State of the art and needed building energy modeling improvements

End-use electrical loads in residential and commercial buildings are evolving into flexible and cost-effective resources to improve electric grid reliability, reduce costs, and support increased hosting of distributed renewable generation. This article reviews the simulation of utility services delivered by buildings for the purpose of electric grid operational modeling. We consider services delivered to (1) the high-voltage bulk power system through the coordinated action of many, distributed building loads working together, and (2) targeted support provided to the operation of low-voltage electric distribution grids. Although an exhaustive exploration is not possible, we emphasize the ancillary services and voltage management buildings can provide and summarize the gaps in our ability to simulate them with traditional building energy modeling (BEM) tools, suggesting pathways for future research and development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Pressure Distribution Over the Fuselage of a PW-9 Pursuit Airplane in Flight

This report presents the results obtained from pressure distribution tests on the fuselage of a PW-9 pursuit airplane in a number of conditions of flight. The investigation was made to determine the contribution of the fuselage to the total lift in conditions considered critical for the wing structure, and also to determine whether the fuselage loads acting simultaneously with the maximum tail loads were of such a character as to be of concern with respect to the structural design of other parts of the airplane. The results show that the contribution of the fuselage toward the total lift is small on this airplane. Aerodynamic loads on the fuselage are, in general, unimportant from the structural viewpoint, and in most cases they are of such character that, if neglected, a conservative design results. In spins, aerodynamic forces on the fuselage produce diving moments of appreciable magnitude and yawing moments of small magnitude, but opposing the rotation of the airplane. A table of cowling pressures for various maneuvers is included in the report.

Rhode, Richard V↗

The fine nebula dust component: A key to chondrule formation by lightning

Our assessment indicates that chondrule formation by lightning is indeed possible in the solar nebula. Previously the overriding objection to the lightning process of chondrule formation has been that low nebula pressures prevented the buildup of large potential differences. The breakdown potential is controlled by the mean free live distance of an electron. We calculate the mean free live distance in pure H2 gas at 2 AU to be approximately 500 m. A fine dust load constituting 4 wt% of the dust in the dusty midplane region leads to a reduced mean free live distance of only 7 m. Very conservatively we estimate the breakdown potential to be at least 10, 1.8, and 0.7 V/cm at 1, 2, and 3 AU respectively. We set the radius of the lightning bolt equal to the kinetic mean free path of the gas. Our calculations based on electron drift velocities in a fully ionized H2 gas show that first strike durations are 0.96, 3.4, and 7.0 ms at 1, 2, and 3 AU respectively, in much better accordance with the meteoritic evidence than previous estimates of 10-100 s.

Wasson, J. T.↗

Cell Free and Immobilization Technologies (CFIT)

Today, several key factors negatively impact the production of fuels and chemicals from renewable sources. Common hindrances in the biological production of biochemicals are: (1) end-product or intermediate toxicity to the microbial biocatalyst, (2) the diversion of carbon to biomass formation, and (3) co-production of undesired byproducts. A particularly attractive alternative is to eliminate the biocatalyst entirely and instead operate the desired metabolic pathways in isolation, thus circumventing the roadblocks of biological toxicity, lower yields, and lack of specificity. However, cell-free enzyme systems still suffer from low productivities owing in part to the effects of free diffusion of intermediates, lack of long term enzyme stability, cofactor cost or inefficient recycling rates, and finally, the cost of enzyme production/purification. This project represents a new effort to propose innovative and cost competitive routes to producing biochemicals from a variety of feedstocks using cell free approaches. These routes will help reduce the current risk and cost associated with classical cell free production. Cell free technologies show promise for application to the production of toxic/inhibitory products or products difficult to separate from microbial growth media and can help reduce the production barriers in multiple areas of biological conversion of feedstocks to biochemicals. More specifically, we are developing new technologies and routes that could be used to produce high value biochemicals such as 2,3 BDO and terpenes (among many others) from biomass derived C5/C6 sugars or lignin but also from waste byproducts such as glycerol. This project will lead to significant innovation and also lead to new concepts and rational design of pathways and enzymes. Within this project, we will develop new metabolic enzyme cascades that will represent natural or artificial combinations of enzymes to produce the desired biochemicals from a variety of feedstocks. We are also developing basic design principals for constructing synthetic metabolons, using fusion proteins and synthetic protein scaffolds, to promote substrate channeling and stability while conserving peak activity. Additionally, our efforts include a techno economic analysis (TEA) of cell free approaches to provide the sensitivities of the process to enzyme loading, activity, pH, reactor volumes, cofactor recycling rates. Finally, we are focusing on further increasing stability, operating lifetime and efficiency of the pathway enzymes by immobilization on support surfaces. We are also focus on immobilizing pathway enzymes or combinations of enzymes on several different conducting polymers and evaluate the effect on stability and operating lifetime. As more combinations become available we will conduct a more systematic study of the means of immobilizing these enzymes. This preliminary work will enable the in-depth study of cofactor recycling at these interfaces using mediators for electron transfer. Taken together, these approaches will enable process intensification, continuous operation, lower capital and separations costs and end-product flexibility, and thus has the potential to contribute significantly to BETO's goals of cost competitive biofuels and bioproducts. To date we have demonstrated 1) the conversion of pyruvate to 2,3 BDO (4 enzymes with cofactor recycling, no additional cofactors needed) at >100g/L (>3g/L/h) using our enzyme tethering approach, 2) Generated mutants of a key redox enzyme with >180- fold improvement in NADH utilization over WT to >85% of NADPH utilization. 3) Produced mevalonate at >10g/L from glucose, limonene at >10g/L from mevalonate and more than >5g/L from glucose with crude enzyme preparations and complete cofactor recycling. 4) successfully generated fully active cross-linked aggregates (CLEAs) of NOX, a cofactor-regenerating water-forming oxidase that is key to our process with increased stability 5) Engineered and identified enzymes able to use the biomimetic cofactor NMN and synthesized new synthetic cofactors.

biocatalysis↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Rooftop unit comparison calculator: a framework for comparing performance of rooftop units with building energy simulation

The applications of building energy simulation (BES) in designing heating, ventilation, and air conditioning (HVAC) systems are limited by the high costs of developing simulation models and the lack of references for determining the model parameters. This paper presents a software framework for selecting designs for rooftop unit HVAC (RTU) systems with BES. Specifically, this framework reduces the cost of using BES by automating the generation of EnergyPlus models. It also employs a systematic method for determining model parameters based on well-accepted datasets. We applied this framework in a comprehensive assessment of an advanced design of RTU systems in which 478 EnergyPlus models were developed without human involvement. The assessment reveals that replacing a constant-speed fan/coil with a multiple-speed fan/coil may not guarantee better overall performance. In conclusion, it also suggests the benefits of replacing furnace coils with heat pumps are subject to utility cost, weather conditions, and heating load profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Why is My Zero Energy Home Not a Zero Carbon Home?

For years, carbon calculations were done very simply. The method of calculation was to take annual totals of energy consumption and multiply by an average emission factor, either for the grid serving a project or for a larger region (e.g. an EPA eGRID sub region). The level of accuracy of this approximation was reasonably good, although the issue of accuracy was not, to our knowledge, tested. And the data required were minimal – just a year’s worth of bills for each fuel and one lookup factor. But this method assures that a net zero energy home is automatically a net zero carbon home because zero times any possible emission factor is still zero. Starting in the early 2010s, things changed – grids were starting to rely more and more heavily on renewables, and the difference was showing up on aggregate load curves. This was perhaps noticed first in California, where aggressive renewable policies led to significant renewable power generation large enough to affect the overall shape of the diurnal load curve for the Independent Systems Operator.

14 SOLAR ENERGY↗

Isotopic Evidence for the Source and Fate of Phosphorus in Everglades Wetland Ecosystems

Phosphorus has historically been a limiting nutrient in the Florida Everglades. Increased P loading to the Everglades over the past several decades has led to significant changes in water quality and plant communities. Stormwater runoff that drains agricultural lands and enters the Water Conservation Areas (WCAs) are known to contain elevated levels of P, but the exact source of this P has not been fully determined. Here the results of an O isotope study of dissolved inorganic phosphate (DIP) in both polluted and relatively pristine (or reference) areas of the Everglades are reported. The data reveal spatial and temporal variations in the delta 18O signature of DIP, reflecting the source and the degree of cycling of P. The delta 18O values of DIP collected from the Everglades National Park were close or equal to the predicted delta 18O values of DIP formed in situ in equilibrium with ambient water, indicating that P is quickly cycled in the water column in oligotrophic ecosystems with very low P concentrations. However, most DIP samples collected from areas impacted by agricultural runoff yielded delta 18O values that deviated from the predicted equilibrium DIP delta 18O values based on the delta 18O of water and water temperature, suggesting that biological cycling of P was not rapid enough to remove the fertilizer ?18O signature in the DIP pool from areas receiving high P loading. The delta 18O signature of DIP in impacted areas reflects a mixing of fertilizer P and biologically cycled P, where the relative proportions of biologically cycled vs. fertilizer DIP are controlled by both biological (microbial activities and plant uptake) and hydrologic factors (loading rate and residence time). Using a two-end-member (i.e., fertilizer P and biologically cycled P) mixing model, fertilizers were estimated to contribute about 15 100% of the DIP pool in the highly impacted areas of the northern Everglades, whereas the DIP pool in the reference (i.e., relatively pristine) wetlands in the Everglades National Park was dominated by biologically cycled P. The study shows that O isotopic measurements of dissolved PO(exp 3-, sub 4) can be a useful tool for tracing the fertilizer P inputs to freshwater ecosystems.

Li, Xin↗

On the Loading Rate Dependence of Environment-assisted Cracking in Sensitized AA5456-H116 Exposed to Marine Environments

The influence of the applied loading rate (dK/dt) on the environment-assisted cracking (EAC) behavior of sensitized AA5456-H116 in 0.6 M NaCl at applied potentials ranging from −800 to −900 mV_SCE is assessed via a rising-K testing framework. The applied potential strongly affects the dK/dt-dependence of EAC with results suggesting a minimal influence for potentials more positive than −830 mVSCE and a stronger dK/dt-dependence for potentials more negative than −830 mV_SCE. Crack growth rates measured using rising versus static K testing are compared, which demonstrates that rising K methods consistently yield conservative EAC metrics with increased efficiency.

Al-Mg↗