Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservation of intensity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Precision Fe K-Alpha and Fe K-Beta Line Spectroscopy of the Seyfert 1.9 Galaxy NGC 2992 with Suzaku

We present detailed time-averaged X-ray spectroscopy in the 0.5-10 keV band of the Seyfert 1.9 galaxy NGC 2992 with the Suzaku X-ray Imaging Spectrometers (XIS). The source had a factor approximately 3 higher 2-10 keV flux (approximately 1.2 x l0(exp -11) erg per square cm per s) than the historical minimum and a factor approximately 7 less than the historical maximum. The XIS spectrum of NGC 2992 can be described by several components. There is a primary continuum, modeled as a power-law with a photon index of Gamma = 1.57(sup +0.06) (sup -0.03) that is obscured by a Compton-thin absorber with a column density of 8.01(sup +0.6) (sup -0.5)x l0 (exp 21) per square cm. . There is another, weaker, unabsorbed power-law component (modeled with the same slope as the primary), that is likely to be due to the primary continuum being electron-scattered into our line-of-sight by a region extended on a scale of hundreds of parsecs. We measure the Thomson depth of the scattering zone to be Tau = 0.072 +/- 0.021. An optically-thin thermal continuum emission component, which probably originates in the same extended region, is included in the model and yields a temperature and luminosity of KT = 0.656(sup +0.088) (sup -0.0.61) keV and approximately 1.2 +/- 0.4 x l0 (exp 40) erg per s respectively. We detect an Fe K emission complex which we model with broad and narrow lines and we show that the intensities of the two components are decoupled at a confidence level > 3 sigma. The broad Fe K alpha line has an equivalent width of 118(sup +32) (sup -61) eV and could originate in an accretion disk (with inclination angle greater than approximately 30 deg) around the putative central black hole. The narrow Fe K alpha line has an equivalent width of 1632(sup +47) (sup -26) eV and is unresolved (FWHM < 4630 km per s) and likely originates in distant matter. The absolute flux in the narrow line implies that the column density out of the line-of-sight could be much higher than measured in the line-of-sight, and that the mean (historically-averaged) continuum luminosity responsible for forming the line could be a factor of several higher than that measured from the data. We also detect the Fe K Beta line (corresponding to the narrow Fe K alpha line) with a high signal-to-noise ratio and describe a new robust method to constrain the ionization state of Fe responsible for the Fe K alpha and Fe K Beta lines that does not require any knowledge of possible gravitational and Doppler energy shifts affecting the line energies. For the distant line-emitting matter (e. g. the putative obscuring torus) we deduce that the predominant ionization state is lower than Fe VIII (at 99% confidence), conservatively taking into account residual calibration uncertainties in the XIS energy scale and theoretical and experimental uncertainties in the Fe K fluorescent line energies. From the limits on a possible Compton-reflection continuum it is likely that the narrow Fe K alpha and Fe K Beta lines originate in a Compton-thin structure.

Yaqoob, Tahir↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unlocking Energy Efficiency: Debunking Myths on the Road to Decarbonization

Energy efficiency is widely recognized as the foundational and most critical strategy for decarbonizing the manufacturing sector. Misconceptions surrounding energy efficiency measures often hinder their widespread adoption. This article aims to debunk five common myths and provides data and resources to help implement efficiency projects faster and more effectively to achieve greater decarbonization. First, the article challenges the myth that organizations have exhausted all possible energy efficiency opportunities by achieving voluntary energy intensity goals or energy performance certification. Second, it also addresses the misconceptions that efficiency projects are capital-intensive, require many qualified specialists, and have long investment return periods. By presenting real-world case studies and referencing commonly found efficiency opportunities, the article illustrates that energy-savings opportunities are ubiquitous. Organizations can use various contracting mechanisms as well as financial and technical resources from utility companies and government programs to lessen their burden. The notion that efficiency measures can be implemented solely in proprietorship facilities is dispelled. This article emphasizes the importance of green leases and explains that aligning decarbonization goals between the lessor and lessee can help drive savings for both parties. Finally, using unbundled renewable energy certificates as the sole pathway to decarbonization is strongly discouraged. By debunking these prevalent myths, this article aims to foster a deeper understanding of energy efficiency’s potential as a cornerstone of decarbonization efforts and to embrace it as a critical pathway toward a sustainable future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Skewering the silos: using Brick to enable portable analytics, modeling and controls in buildings

Nearly all large commercial buildings have heating, ventilation and air conditioning (HVAC) systems, lighting systems, safety and other systems controlled by a computer—a dedicated server with a building energy management system (BMS). However, these BMSs are proprietary with each building’s assets (that is, fans, valves, pumps, and their setpoints) named and coded uniquely by the BMS vendor or engineer; building analytics and control algorithms are written specific to the assets and the building. Thus, any control updates or analytics to improve building performance—especially critical to reduce greenhouse emissions or improve load flexibility—are labor intensive and costly. The Brick schema was developed so the same analysis or control algorithms can work on a variety of buildings if each is digitally represented in a Brick data model. The goal of this project was to further the development of Brick to extend it beyond an academic project with demonstrated success in a small field study, to a practical choice for industrial and commercial stakeholders seeking to realize value from building data. To do this, we executed four objectives: (1) expand the Brick schema including its modeling capabilities and vocabulary, (2) develop tools for integrating Brick with existing digital technologies and representations in buildings, (3) develop an open-source analytics platform to facilitate use of Brick in delivering data value, and (4) demonstrate Brick-driven analytics and controls in real settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Pilot-scale Black Liquor Membrane for Water Removal at Ahlstrom-Munksjö Paper Mill in Mosinee, WI

Project Background: The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized technologies in the industrial sector to help inform decisions towards accelerating commercialization and deployment. Pulp and paper is considered one of the most energy-intensive industries in the manufacturing sector. There are several methodologies for converting wood into pulp in the paper-making industry. The kraft process is a chemical method for producing wood pulp. The kraft process generates black liquor as a byproduct of pulp production. Traditionally, water is evaporated from the liquor by a set of multi-effect evaporators (MEEs), which concentrate weak black liquor (WBL) into strong black liquor (SBL) to support efficient combustion in a recovery boiler. Concentrating black liquor is an energy-intensive step in recovering pulping chemicals and generating high-pressure steam from dissolved wood solids. About 7% of pulp and paper energy usage, or nearly 164 trillion Btu, is used to remove water from black liquor in U.S. kraft pulp mills per year. The U.S. DOE’s IEDO is interested in the black liquor membrane technology evaluated in this report because it offers the potential for a more energy-efficient and less carbon-intensive kraft pulping process across 99 kraft pulp mills in 24 states (Agenda 2020 Technology Alliance 2016). This ITV project validates an innovative black liquor membrane technology for kraft pulp mills to understand its impact and benefits. Via Separations is a technology vendor that developed a graphene oxide membrane system to remove water from WBL before entering the evaporator set. High-pressure positive displacement (HPR) pumps move the black liquor through membranes that separate water and create a more concentrated black liquor. The vendor claims their pre-commercial technology reduces evaporator steam consumption by dewatering WBL before entering the evaporators. They also claim their technology has non-energy benefits such as enhanced soap collection and improved pulp throughput. This evaluation focuses on validating the energy and carbon dioxide (CO 2 e) emissions benefits associated with the membrane system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Lighting Application Efficacy Measurement Framework

Lighting significantly contributes to electricity consumption in buildings. The most widely used measure of lighting energy efficiency, luminous efficacy, quantifies only the intensity of light generated by light sources, weighted by the spectral sensitivity of the human visual system (i.e., the energy efficiency of individual lighting devices). However, luminous efficacy does not fully address the use of lighting in architectural spaces. To address these limitations, we developed a framework to framework to calculate lighting application efficacy (LAE), the relationship between the electrical power consumed by lighting hardware, and the amount of light that contributes to the visual perception of building occupants. The proposed LAE framework is based on the primary pathway of light in architectural settings: the generation and emission of light from a luminaire, the travel of the light throughout the space and into the eyes of occupants, and the process of visual perception. The project’s primary outputs are a method for measuring lighting application efficacy and a framework for facilitating future research to improve the metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Assembly Progress Monitoring in Modular Construction Factories Using Computer Vision-Based Instance Segmentation

Modular construction has recently gained interest as a transformative construction method. In this method, a large portion of the construction is performed inside factories, where processes are fast-paced and interdependent; therefore, any deviation from the schedule can delay the production. Such deviations are frequent in modular factories due to the labor-intensive nature of the tasks. This propagation of delays can be mitigated by continuously monitoring each process; however, current manual monitoring methods are laborious, and recently proposed contact sensor-based methods are intrusive to the work. In addition, recent computer vision-based monitoring methods inside factories are limited to detection algorithms that fail to provide the pixel-level accuracy required for assembly progress monitoring in highly occluded factory scenes, and they require a large number of manual annotations. Therefore, this paper proposes a method to monitor the installation of subassemblies in modular construction factories using mask R-CNN instance segmentation and improves the data efficiency of the model using a copy-paste augmentation method. This method was validated on the CCTV videos captured from a modular construction factory in the US, resulting in a 9% mAP improvement in segmentation.

computer vision↗

The First Swift Intensive AGN Accretion Disk Reverberation Mapping Survey

Swift intensive accretion disk reverberation mapping of four AGN yielded light curves sampled ∼200–350 times in 0.3–10 keV X-ray and six UV/optical bands. Uniform reduction and cross-correlation analysis of these data sets yields three main results: (1) The X-ray/UV correlations are much weaker than those within the UV/optical, posing severe problems for the lamp-post reprocessing model in which variations in a central X-ray corona drive and power those in the surrounding accretion disk. (2) The UV/optical interband lags are generally consistent with t μ l4 3 as predicted by the centrally illuminated thin accretion disk model. While the average interband lags are somewhat larger than predicted, these results alone are not inconsistent with the thin disk model given the large systematic uncertainties involved. (3) The one exception is the U band lags, which are on average a factor of ∼2.2 larger than predicted from the surrounding band data and fits. This excess appears to be due to diffuse continuum emission from the broad-line region (BLR). The precise mixing of disk and BLR components cannot be determined from these data alone. The lags in different AGN appear to scale with mass or luminosity. We also find that there are systematic differences between the uncertainties derived by JAVELIN versus more standard lag measurement techniques, with JAVELIN reporting smaller uncertainties by a factor of 2.5 on average. In order to be conservative only standard techniques were used in the analyses reported herein.

R. Edelson↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty in inventories for life cycle assessment: State‐of‐the‐art, challenges, and new technologies

Uncertainty is a critical factor that can hinder the quality and potential applications of life cycle assessment (LCA) results. A prominent source of uncertainty stems from the life cycle inventory (LCI) data. Various methodologies exist to estimate the uncertainty associated with LCI data, primarily based on the widely used structured pedigree matrix approach or the computationally intensive Monte Carlo simulation. This perspective review explores how new technologies (e.g., computational algorithms and data collection methods) from data science and related fields can contribute to identifying, quantifying, and reducing uncertainty in LCI modeling. A brief overview of the sources of uncertainty in LCI modeling and how they are addressed in current LCA practice is provided. Additionally, several new technologies are identified, and the potential benefits of their implementation in reducing uncertainties in LCI modeling are discussed. This perspective review concludes by identifying potential areas that require further development for these technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moving Zero Energy Office Buildings to the Mainstream: Establishing Design Guidelines and Energy Targets: Preprint

Office buildings represent a significant portion of the commercial sector and are ideal candidates to lead the market towards achieving zero energy or zero energy ready buildings. The variety of sizes and uses for office buildings make them challenging to determine set design guidance that can be deployed across the market. A project committee for ASHRAE’s Zero Energy - Advanced Energy Design Guide (ZE-AEDG) for small and medium office buildings , comprised of members from five major national associations with market-pull in commercial buildings, created design guidance for achieving zero energy office buildings for new construction and major retrofit. This design guidance focuses on the process, providing a pathway for both office owners and design teams to achieve zero energy status. Energy use intensity targets range from 16 kBtu/ft²·yr to 36 kBtu/ft²·yr for the different climate zones were established such that office buildings can be “zero-ready,” that is, having low energy consumption that can easily be offset with renewables, preferably on-site. The design guidance was rooted in extensive energy modeling, as well as case studies of actual office buildings that have achieved high levels of energy performance and met zero energy or zero energy ready status. A unique aspect of the zero-energy guide is that it is not compared against a baseline but focuses on achieving an absolute target. The paper presents process of creating the targets, the selection of strategies to achieve the targets, and sample case studies that show how the cost-sensitive solutions are achievable for the design community. It also presents outreach strategies to deploy market achievable zero energy measures.

buildings↗

Feasibility Study of Real-Time Carbon Emission Responsive Electric Vehicle Charging Control in Buildings: Preprint

With the progressing electrification of the transportation sector, the source of carbon emissions is gradually shifting from fossil fuel to grid electricity because of electric vehicles (EVs). The carbon intensity of the grid can fluctuate significantly within hours due to the time-varying power generation mix. Therefore, shifting EV charging loads to cleaner hours in response to the carbon intensity signals can reduce carbon emissions. Existing EV charging control methods typically consider the electricity price or the available generation by distributed energy resources (e.g., photovoltaics) to inform decision-making. Such methods tend to reduce energy costs but may neglect the environmental impact of EV charging activities. We propose and compare four carbon emission responsive EV charging controllers with various control rules. The proposed controllers are evaluated based on simulation experiments using metrics such as carbon emission reduction potential, state of charge (SOC) at departure, and peak demand. We found that the need of EV owners to have full batteries at departure could lead to an emission increase when the curtailed EV charge was compensated before departure. Further, up to 12.7% of carbon emission reduction can be achieved if the EV owners reduce the target SOC at departure by less than 15%.

carbon emission↗

The pursuit of net-positive sustainability for industrial decarbonization with hybrid energy systems

We report signatories of the Paris Agreement are set to miss their climate targets. The net-zero pledges announced to date across many countries and private industries are insufficient to achieve carbon neutrality, which requires implementation of far-reaching and significantly scaled-up climate-positive actions. All technology options that pertain to deep decarbonization and carbon removal must be part of the mitigation portfolio. Transformative action plans must be established in which every individual/organization around the globe is an actor of changes in relation to net-zero goals. Such plans must involve governmental policy support but also encourage voluntary efforts to boost innovations, investments, initiatives, and behavioral changes. Recognition of these efforts is made quantifiable with the concepts of carbon handprint and net positivity. This paper presents a carbon handprint perspective on characterizing the environmental benefits of hybrid energy systems (HESs)—a widely applicable solution to cleaner production leveraging the capabilities of a portfolio of low-carbon energy sources—that provide heat and electricity to industrial processes. First, the carbon handprint and net positivity concepts and their calculation approach are introduced. The state of the art of HES-enabled industrial cogeneration is then surveyed, and the greenhouse gas emission intensities of different energy sources that power HESs are compared. Next, drawing on a case study about a US chemical facility's voluntary initiative to explore replacing its fossil fuel–based cogeneration infrastructure with a clean energy–generated HES, several technically viable scenarios are evaluated—especially those with small modular nuclear reactors—to illustrate how the positive-thinking handprint approach helps encourage and inform the search for widespread influence pathways in pursuit of net-positive sustainability. Finally, current knowledge gaps in the case study are identified, and opportunities to scale up the proposed handprint-based analysis are outlined with consideration of an expanded role of HESs in fulfilling climate objectives.It is envisioned that like-minded decision makers in the industry sector and beyond will adopt this perspective and act synergistically to enhance their environmental stewardship through voluntary actions and make greater contributions to the planet's climate future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mapping use cases and dataset needs for benchmarking buildings data

A perennial challenge in buildings research is the lack of high-quality datasets that can be relied upon for a wide array of tasks, including model calibration and improving energy efficiency and load flexibility. Instrumenting a building for data collection is resource intensive, so it is important to be methodical in the approach and ensure that resulting data are flexible and useful for a broad range of analyses. This study aims to fill the gaps in characterizing potential use cases for buildings datasets and mapping them to dataset needs using a well-defined data infrastructure. Here, we have developed a systematic mapping strategy between buildings dataset needs and use cases to help streamline the processes of efficiently targeting datasets, designing building sensing systems, and determining buildings research use cases. We selected 14 prospective use cases and 11 refined buildings data categories for developing the preliminary dataset-needs-to-use-cases mapping matrix (‘DN-UC mapping matrix’) with generic ‘Tags’—a detailed sub-level of data categories extracted by justifying the needs of an aspect of the datasets to use cases. We present two example applications of the developed mapping matrix to demonstrate use of the mapping matrix and its effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗