Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

CRPropa 3.1—a low energy extension based on stochastic differential equations

The propagation of charged cosmic rays through the Galactic environment influences all aspects of the observation at Earth. Energy spectrum, composition and arrival directions are changed due to deflections in magnetic fields and interactions with the interstellar medium. Today the transport is simulated with different simulation methods either based on the solution of a transport equation (multi-particle picture) or a solution of an equation of motion (single-particle picture). We developed a new module for the publicly available propagation software CRPropa 3.1, where we implemented an algorithm to solve the transport equation using stochastic differential equations. This technique allows us to use a diffusion tensor which is anisotropic with respect to an arbitrary magnetic background field. The source code of CRPropa is written in C++ with python steering via SWIG which makes it easy to use and computationally fast. In this paper, we present the new low-energy propagation code together with validation procedures that are developed to proof the accuracy of the new implementation. Furthermore, we show first examples of the cosmic ray density evolution, which depends strongly on the ratio of the parallel κ{sub ∥} and perpendicular κ{sub ⊥} diffusion coefficients. This dependency is systematically examined as well the influence of the particle rigidity on the diffusion process.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of pair interparticle interaction in nonideal dissipative systems

A new method is proposed for determining the interaction forces between particles in nonideal dissipative systems with isotropic pair potentials. The method is based on the solution of the inverse problem describing the motion of interacting particles by a system of Langevin equations and allows one to recover the parameters of the external confining potential without referring to a priori information on the friction coefficients of the particles. This procedure was tested by a numerical simulation of the problem in a wide range of parameters typical of experimental conditions in a laboratory dusty plasma. The results of the first experimental approbation of the method as applied to the analysis of the interaction of dust particles in a laboratory high-frequency capacitive discharge plasma are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of the stability and electronic properties of carbon nanotori synthesized by a high-voltage pulsed discharge in ethanol vapor

An experimental technique for increasing the yield of carbon-nanotube nanotori using the modified arc synthesis method is proposed. New physical knowledge on the systematic features of the interrelation between the properties of nanotori and atomic-network topology are theoretically established for the first time. The experiments are performed based on new technology for synthesizing nanotori on nickel-catalyst particles by a high-voltage pulsed discharge in ethanol vapor and using atomic-force microscopy. Stability is predicted using an original procedure for calculating local atomic stresses. Simulation shows that the zigzag chirality corresponds to the most stable topology of nanotori. Using the tight binding method, it is shown that, depending on the chirality type, nanotori are divided into two classes, i.e., those with metal and semiconductor conductivity.

36 MATERIALS SCIENCE↗

Lung Tumor Radiofrequency Ablation: Where Do We Stand?

Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3-14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Percutaneous Needle Biopsy in Patients with Suspected Retroperitoneal Fibrosis: A Retrospective Cohort Study

Purpose: The outcome of CT-guided biopsy in patients with suspected retroperitoneal fibrosis (RF), regarded as technically challenging, remains unclear. This study aimed to evaluate the results of CT-guided biopsy in patients with lesions considered in the differential diagnosis of RF and compare them with results from patients with other retroperitoneal lesions. Materials and Methods: Patients who underwent CT-guided biopsy of retroperitoneal lesions between January 2010 and September 2018 were retrospectively reviewed. The study cohort with retroperitoneal lesions surrounding the infra-abdominal aorta, iliac vessels, and/or ureters was divided into two groups: Group F included patients with lesions for which RF was considered in the differential diagnosis, and Group C comprised patients with a retroperitoneal mass or lymphadenopathy. Lesion size and depth, and biopsy details including technical success, position, procedure time, diagnostic yield, and complications between the two groups were compared. Results: Group F included 27 patients (mean age 68.5 years ± 11.6, 17 male) and Group C 30 patients (mean age 65.0 years ± 11.8, 16 male). The short axis was significantly smaller in Group F than in Group C (19 mm vs 26 mm, P = 0.041), and procedure time was significantly longer in Group F than in Group C (31.5 min ± 13.2 vs 20.3 min ± 8.4, P = 0.001). Technical success rate (93% vs 100%), accuracy (93% vs 93%), and complications (3.7% vs 10%) between Groups F and C were not significantly different. Conclusions: CT-guided biopsy of patients with suspected RF is considered safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to Boost the Breast Tumor Bed? A Multidisciplinary Approach in Eight Steps

Purpose: To describe a new procedure for breast radiotherapy that will improve tumor bed localization and radiotherapy treatment using a multidisciplinary approach. Patients and Methods: This pilot study was conducted by departments of radiation oncology, surgery, and radiology. A new procedure has been implemented, summarized as eight steps: from pre-surgery contrast CT to surgery, tumor bed planning target volume (PTV) determination, and finally breast and tumor bed irradiation. Results: Twenty patients presenting with T1N0M0 tumors were enrolled in the study. All patients underwent lumpectomy with the placement of surgical clips in the tumor bed region. During surgery, 1 to 5 clips were placed in the lumpectomy cavity before the plastic procedure. All patients underwent pre- and postoperative CT scans in the treatment position. The two sets of images were registered with a match-point registration. All volumes were contoured and the results evaluated. The PTV included the clips region, the gross tumor volume, and the surgical scar, with an overall margin of 5-10 mm in all directions, corresponding to localization and setup uncertainties. For each patient the boost PTV was discussed and compared with our standard forward-planned PTV. Conclusions: We demonstrate the feasibility of a tumor bed localization and treatment procedure that seems adaptable to routine practice. Our study shows the advantages of a multidisciplinary approach for tumor bed localization and treatment. The use of more than 1 clip associated with pre- to postoperative CT image registration allows better definition of the PTV boost volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Functionalization of SBA-15 mesoporous silica by Cu-phosphonate units: Probing of synthesis route

Mesoporous silica SBA-15 containing propyl-copper phosphonate units was investigated. The structure of mesoporous samples was tested by N{sub 2} isothermal sorption (BET and BHJ analysis), TEM microscopy and X-Ray scattering. Quantitative analysis EDX has given information about proportions between component atoms in the sample. Quantitative elemental analysis has been carried out to support EDX. To examine bounding between copper atoms and phosphonic units the Raman spectroscopy was carried out. As a support of Raman scattering, the theoretical calculations were made based on density functional theory, with the B3LYP method. By comparison of the calculated vibrational spectra of the molecule with experimental results, distribution of the active units inside silica matrix has been determined. - Graphical abstract: The present study is devoted to mesoporous silica SBA-15 containing propyl-copper phosphonate units. The species were investigated to confirm of synthesis procedure correctness by the micro-Raman technique combined with DFT numerical simulations. Complementary research was carried out to test the structure of mesoporous samples. - Highlights: • SBA-15 silica functionalized with propyl-copper phosphonate units was synthesized. • Synthesis efficiency probed by Raman study supported with DFT simulations. • Homogenous distribution of active units was proved. • Synthesis route enables precise control of distance between copper ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using standard calibrated geometries to characterize a coaxial high purity germanium gamma detector for Monte Carlo simulations

A detector model optimization procedure based on matching Monte Carlo simulations with measurements for two experimentally calibrated sample geometries which are frequently used in radioactivity measurement laboratories results in relative agreement within 5% between simulated and measured efficiencies for a high purity germanium detector. The optimization procedure indicated that the increase in dead layer thickness is largely responsible for a detector efficiency decrease in time. The optimized detector model allows Monte Carlo efficiency calibration for all other samples of which the geometry and bulk composition is known. The presented method is a competitive and economic alternative to more elaborate detector scanning methods and results in a comparable accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled scalar fields in a flat FRW universe: renormalisation

We study the non-equilibrium dynamics of a system of coupled scalar fields in a Friedmann-Robertson-Walker (FRW) universe. We consider the evolution of spatially homogeneous ''classical'' fields and of their quantum fluctuations including the quantum backreaction in the one-loop approximation. We discuss in particular the dimensional regularisation of the coupled system and a special subtraction procedure in order to obtain the renormalised equations of motion and the renormalised energy-momentum tensor and ensure that the energy is well-defined and covariantly conserved. These results represent at the same time a theoretical analysis and a viable scheme for stable numerical simulations. As an example for an application of the general formalism, we present simulations for a hybrid inflationary model.

79 ASTRONOMY AND ASTROPHYSICS↗

Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach

Purpose: A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values (''intensity''). Methods: A variant of the Demons algorithm was developed in which an estimate of the relationship between CT and CBCT intensity values for specific materials in the image is computed at each iteration based on the set of currently overlapping voxels. This tissue-specific intensity correction is then used to estimate the registration output for that iteration and the process is repeated. The robustness of the method was tested in CBCT images of a cadaveric head exhibiting a broad range of simulated intensity variations associated with x-ray scatter, object truncation, and/or errors in the reconstruction algorithm. The accuracy of CT-CBCT registration was also measured in six real cases, exhibiting deformations ranging from simple to complex during surgery or radiotherapy guided by a CBCT-capable C-arm or linear accelerator, respectively. Results: The iterative intensity matching approach was robust against all levels of intensity variation examined, including spatially varying errors in voxel value of a factor of 2 or more, as can be encountered in cases of high x-ray scatter. Registration accuracy without intensity matching degraded severely with increasing magnitude of intensity error and introduced image distortion. A single histogram match performed prior to registration alleviated some of these effects but was also prone to image distortion and was quantifiably less robust and accurate than the iterative approach. Within the six case registration accuracy study, iterative intensity matching Demons reduced mean TRE to (2.5{+-}2.8) mm compared to (3.5{+-}3.0) mm with rigid registration. Conclusions: A method was developed to iteratively correct CT-CBCT intensity disparity during Demons registration, enabling fast, intensity-based registration in CBCT-guided procedures such as surgery and radiotherapy, in which CBCT voxel values may be inaccurate. Accurate CT-CBCT registration in turn facilitates registration of multimodality preoperative image and planning data to intraoperative CBCT by way of the preoperative CT, thereby linking the intraoperative frame of reference to a wealth of preoperative information that could improve interventional guidance.

60 APPLIED LIFE SCIENCES↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1.4 mSv was measured, respectively. Using kilovoltage or megavoltage radiation to obtain cone beam computed tomography scans led to an additional dose of 8-46 mSv. For treatment verification images performed once per week using double exposure technique, an additional effective dose of up to 18 mSv was measured. Conclusions: Daily setup imaging using kilovoltage planar images or TomoTherapy megavoltage fan beam CT imaging can be used as a standard procedure in clinical routine. Daily kilovoltage and megavoltage cone beam computed tomography setup imaging should be applied on an individual or indication based protocol. Depending on the imaging scheme applied, image-guided radiation therapy can be administered without increasing the dose outside of the treated volume compared to therapies without image guidance.

60 APPLIED LIFE SCIENCES↗

Clinical implementation of radiosurgery using the Helical TomoTherapy unit

The American Society of Radiation Oncology has recently recommended the use of radiosurgery to manage brain metastases. For such a recommendation to be implemented in a widespread manner, radiosurgery must be accessible at community radiation therapy facilities. The work presented here describes our clinical experience in the implementation of radiosurgery using a Helical TomoTherapy unit. Helical TomoTherapy is a unique dose-delivery system designed to perform intensity-modulated radiation therapy (IMRT). The system built on the ring-based gantry has the tight machine tolerances required for radiosurgery. A frameless system consisting of a thermoplastic mask and a noninvasive ''stereotactic radiosurgery (SRS)-stereotactic radiotherapy (SRT)'' fixation device is used for patient immobilization. Treatment planning is performed using the TomoHD treatment planning system designed for IMRT. The image-guidance system on the Helical TomoTherapy is used for patient localization. Our clinical experience demonstrated that the radiosurgery procedure can be streamlined as we do for IMRT patients. The treatment time of about 10 minutes is comparable with that for IMRT patients. The same patient-specific quality assurance for IMRT is used for radiosurgery. As demonstrated, SRS using Helical TomoTherapy is not a whole-day event, unlike SRS using other dose-delivery systems or SRS performed in the past.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing the quasi-absolute method in photon activation analysis

In photon activation analysis (PAA), relative methods are widely used because of their accuracy and precision. Absolute methods, which are conducted without any assistance from calibration materials, are seldom applied for the difficulty in obtaining photon flux in measurements. This research is an attempt to perform a new absolute approach in PAA - quasi-absolute method - by retrieving photon flux in the sample through Monte Carlo simulation. With simulated photon flux and database of experimental cross sections, it is possible to calculate the concentration of target elements in the sample directly. The QA/QC procedures to solidify the research are discussed in detail. Our results show that the accuracy of the method for certain elements is close to a useful level in practice. Furthermore, the future results from the quasi-absolute method can also serve as a validation technique for experimental data on cross sections. The quasi-absolute method looks promising.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intrahepatic Flow Redistribution in Patients Treated with Radioembolization

IntroductionIn planning Yttrium-90 ({sup 90}Y)-radioembolizations, strategy problems arise in tumours with multiple arterial supplies. We aim to demonstrate that tumours can be treated via one main feeding artery achieving flow redistribution by embolizing accessory vessels.MethodsOne hundred {sup 90}Y-radioembolizations were performed on 90 patients using glass microspheres. In 19 lesions/17 patients, accessory branches were found feeding a minor tumour portion and embolized. In all 17 patients, the assessment of the complete perfusion was obtained by angiography and single photon emission computerized tomography–computerized tomography (SPECT–CT). Dosimetry, toxicity, and tumor response rate of the patients treated after flow redistribution were compared with the 83 standard-treated patients. Seventeen lesions in 15 patients with flow redistribution were chosen as target lesions and evaluated according to mRECIST criteria.ResultsIn all patients, the complete tumor perfusion was assessed immediately before radioembolization by angiography in all patients and after the {sup 90}Y-infusion by SPECT–CT in 15 of 17 patients. In the 15 assessable patients, the response rate in their 17 lesions was 3 CR, 8 PR, and 6 SD. Dosimetric and toxicity data, as well tumour response rate, were comparable with the 83 patients with regular vasculature.ConclusionsAll embolization procedures were performed successfully with no complications, and the flow redistribution was obtained in all cases. Results in term of toxicity, median dose administered, and radiological response were comparable with standard radioembolizations. Our findings confirmed the intratumoral flow redistribution after embolizing the accessory arteries, which makes it possible to treat the tumour through its single main feeding artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palliative Treatment of Rectal Carcinoma Recurrence Using Radiofrequency Ablation

Purpose: To evaluate the safety and efficacy of CT-guided radiofrequency (RF) ablation for the palliative treatment of recurrent unresectable rectal tumors. Materials and Methods: Twenty-seven patients with locally recurrent rectal cancer were treated with computed tomography (CT)-guided RF ablation. Therapy was performed with the patient under conscious sedation with a seven- or a nine-array expandable RF electrode for 8-10 min at 80-110 Degree-Sign C and a power of 90-110 W. All patients went home under instructions the next day of the procedure. Brief Pain Inventory score was calculated before and after (1 day, 1 week, 1 month, 3 months, and 6 months) treatment. Results: Complete tumor necrosis rate was 77.8% (21 of a total 27 procedures) despite lesion location. BPI score was dramatically decreased after the procedure. The mean preprocedure BPI score was 6.59, which decreased to 3.15, 1.15, and 0.11 at postprocedure day 1, week 1, and month 1, respectively, after the procedure. This decrease was significant (p < 0.01 for the first day and p < 0.001 for the rest of the follow-up intervals (paired Student t test; n - 1 = 26) for all periods during follow-up. Six patients had partial tumor necrosis, and we were attempted to them with a second procedure. Although the necrosis area showed a radiographic increase, no complete necrosis was achieved (secondary success rate 65.6%). No immediate or delayed complications were observed. Conclusion: CT-guided RF ablation is a minimally invasive, safe, and highly effective technique for treatment of malignant rectal recurrence. The method is well tolerated by patients, and pain relief is quickly achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolotherapy with N-Butyl Cyanoacrylate for Ectopic Varices

PurposeTo address technical feasibility and clinical outcome of transcatheter embolotherapy with N-butyl cyanoacrylate (NBCA) for bleeding ectopic varices.MethodsThe institutional review board approved this retrospective study and waived informed consent. From January 2004 to June 2013, a total of 12 consecutive patients received transcatheter embolotherapy using NBCA for bleeding ectopic varices in our institute. Clinical and radiologic features of the endovascular procedures were comprehensively reviewed.ResultsPreprocedural computed tomography images revealed ectopic varices in the jejunum (n = 7), stoma (n = 2), rectum (n = 2), and duodenum (n = 1). The 12 procedures consisted of solitary embolotherapy (n = 8) and embolotherapy with portal decompression (main portal vein stenting in 3, transjugular intrahepatic portosystemic shunt in 1). With regard to vascular access, percutaneous transhepatic access (n = 7), transsplenic access (n = 4), and transjugular intrahepatic portosystemic shunt tract (n = 1) were used. There was no failure in either the embolotherapy or the vascular accesses (technical success rate, 100 %). Two patients died within 1 month from the procedure from preexisting fatal medical conditions. Only one patient, with a large varix that had been partially embolized by using coils and NBCA, underwent rebleeding 5.5 months after the procedure. The patient was retreated with NBCA and did not undergo any bleeding afterward for a follow-up period of 2.5 months. The remaining nine patients did not experience rebleeding during the follow-up periods (range 1.5–33.2 months).ConclusionTranscatheter embolotherapy using NBCA can be a useful option for bleeding ectopic varices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization by Direct Puncture with a Transpedicular Approach Using an Isocenter Puncture (ISOP) Method in a Patient with a Type II Endoleak After Endovascular Aortic Repair (EVAR)

BackgroundEndovascular aortic repair (EVAR) requires further intervention in 20-30 % of cases, often due to type II endoleak (T2EL). Management options for T2EL include transarterial embolization, direct puncture (DP), or transcaval embolization. We report the case of an 80-year-old man with T2EL who successfully underwent DP embolization.MethodsEmbolization by DP was performed with a transpedicular approach using an isocenter puncture (ISOP) method. An isocenter marker (ICM) was placed at a site corresponding to the aneurysm sac on fluoroscopy in two directions (frontal and lateral views). A vertebroplasty needle was inserted tangentially to the ICM under fluoroscopy and advanced to the anterior wall of the vertebral body. A 20 cm-length, 20-G-PTCD needle was inserted through the outer needle of the 13-G needle and advanced to the ICM. Sac embolization using 25 % N-buty-2-cyanoacrylate diluted with Lipiodol was performed. After complete embolization, rotational DA confirmed good filling of the sac with Lipiodol. The outer cannula and 13-G needle were removed and the procedure was completed.ResultsThe patient was discharged the next day. Contrast-enhanced computed tomography 1 and 8 months later showed no Lipiodol washout in the aneurysm sac, no endoleak recurrence, and no expansion of the excluded aneurysm.ConclusionDP with a transpedicular approach using ISOP may be useful when translumbar and transabdominal approaches prove difficult.

62 RADIOLOGY AND NUCLEAR MEDICINE↗