Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Characterization of Low-Velocity Impact Damage in Toughened Non-Crimp Fabric Laminates

The damage response of resin-infused composites was investigated using quasi-static indentation (QSI) and instrumented drop-weight impact testing. The test specimens were composed of six layers of non-crimp fabrics where each layer contained +45°, 90°, −45°, and 0° plies. The goals of the testing were to identify damage responses that may differ from traditional thermoset materials and provide damage characterization data to evaluate current damage prediction analyses and aid improvements to current damage models. The damage was characterized using X-ray computed tomography (CT) and ultrasonic testing (UT). Incremental QSI loading was used on a single specimen to investigate damage growth in nine steps at progressively higher loads. Realtime acoustic emission data were used to determine the unloading points. Unlike typical thermoset composites, the force-displacement was smooth and showed no obvious indications of damage. The primary damage consisted of large lines of fiber fracture on the plies near the impact surface and delaminations through the thickness. Nine specimens were impacted at nominal impact energies of 25 ft-lbs, 30 ft-lbs, and 35 ft-lbs. The force histories at each energy followed nearly identical paths. Again, no obvious signs of damage were observed in any of the force histories. The general damage response in the dynamic tests was similar to the QSI-loaded specimens. However, repeat specimens impacted with a given impact energy showed variations in the damage. Some characteristics of the damage response were different than those typically observed in thermoset composites and will need to be evaluated using current analysis methods.

Composite Materials↗

Towards Quantifying and Correlating RTV Intumescence to Entry-Relevant Conditions

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also adopted to bond instrumentation plugs of temperature and pressure sensors into heatshield’s tiles. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Experimental data has also shown heating rate-dependent swelling (or intumescence) and shrinking of RTV, these volume changes may cause roughness-induced boundary layer transition. Outgassing and surface oxide formation of RTV upon decomposition also occur, which can be sources of contamination of heat shield sensors. This combination of detrimental effects motivates a critical need to develop a high-fidelity model for RTV ablation. As a first critical step in RTV modeling, a comprehensive material properties database for RTV was collected that account for the lack of data in properties such as pyrolysis char yield, shape change, virgin and char porosity. The next step is to quantify the volume change of RTV as a function of temperature. While this was done in previous campaigns, limited data was collected which showed a possible heating rate dependent intumescent behavior. To further understand the intumescence phenomenon of RTV, numerous dedicated experiments were performed at Beamline 8.3.2 of the Advanced Light Source, where RTV samples were heated while X-ray scans were taken in situ. Micro-Computed Tomography scans were taken in situ for low heating rates (≤ 60 °C/min), whereas continuous radiography scans were taken for higher heating rates (≤ 1500 ºC/min). Unconstrained samples and samples constrained in different holders (quartz, graphite, FiberForm and PICA) were tested to determine the change in intumescence due to confinement. Using deep learning techniques, the tomographies and radiographies are segmented to obtain volume change, porosity, pore size distributions and connectivity. From the results obtained, modifications to the previous RTV intumescence model are proposed, along with preliminary comparisons to testing RTV at high-enthalpy facilities.

RTV↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Phosphate Textural Diversity in CI Chondrites and C-Type Asteroids

Introduction: Apatite, Ca 5 (PO 4 ) 3 (CL/F/OH-), is a ubiquitous phosphate found throughout the solar system, including the most primitive solids, CI-chondrites [1,2] and related samples of carbonaceous asteroids Ryugu [3] and Bennu [4], returned by JAXA’s Hayabusa2 and NASA’s OSIRIS-REx missions, respectively. Apatite in these primitive solids is found as individual grains or mineral clusters and has been inferred to form from the hydrothermal sequence during cooling of their respective parent body or bodies. To better understand the formation history and reworking of these early phosphates we have undertaken a highly coordinated study of phosphate microstructures, geochemistry and U/Pb geochronology from a suite of CI meteorites and carbonaceous asteroid samples. These data have identified novel phosphate microstructures and complex relationships across a suite of apatite grains from the early solar system, indicating multiple episodes of growth and modification on the CI parent body(ies). Methods: Samples of CI chondrites, Alais, Ivuna, Orgueil, Oued Chebeika 002, Yamato (Y) 82162, Y980115, Y980134, and two chips of Hayabusa2 Ryugu particles (A0262 and C0263) have been acquired for analysis. The bulk texture of the samples were first scanned by X-ray Computed Tomography (XCT) using the Nikon XT H 320 within the XFACT facility at NASA JSC or the Xradia 620 Versa at the UTCT facility. Based on the identification of petrofabrics or features of interest from the XCT data, samples were chipped, oriented, potted in epoxy and thick sections were prepared. After anhydrously polishing the samples with silicon carbide and dry diamond powder down to 1 µm, the samples were ion polished using a Hitachi ArBlade. Energy dispersive Xray spectrometry (EDS) maps were collected to ID phosphates of interest using a JEOL 7900F SEM. The internal microstructures of identified phosphates were then mapped by electron backscatter diffraction (EBSD) using the JEOL 7900F. Based on the EDS and EBSD data, domains of interest were targeted for quantitative chemical analyses using a JEOL 8530 EPMA. Subsequently, in situ U-Pb and 207 Pb/ 206 Pb ages will be collected using a Cameca ims1290 secondary ion mass spectrometer at UCLA across a range of microstructures. Results: Apatite grains are ubiquitous throughout the CI chondrites and carbonaceous asteroid materials, found as individual grains, disseminated clusters or grain aggregates. Apatite grains are associated with serpentine, magnet-ite, and/or carbonate. Of particular interest, we have identified individual and aggregate polycrystalline grains ex-hibiting an internal ‘honeycomb’ texture (Fig. 1). Some of these grains appear overprinted by subsequent alteration while others remain unaltered. Apatite halogen sites are dominated by the missing component, assumed to be OH, and F, comparable to published values from Bennu, Ryugu and CM-chondrites [3-5]. However, the Yamato CI-like meteorites show a broader range of Cl values, and one grain from Alais is dominated by CL. Summary: Apatite growth features indicate a protracted and complex growth history, consistent with precipitation from an evolving fluid system. The ‘honeycomb’ texture identified in some CI meteorites is, to the best of our knowledge, the first report of such a microstructure in meteoritic phosphate. The microtextures and zoning will guide subsequent age analyses, to better constrain the formation and reworking of phosphate in CI(-like) materials. Acknowledgments: We thank the National Institute of Polar Research, Japan for samples of Y82162, 980115 and 980134 meteorites, ASU’s Buseck Center for Meteorite Studies for samples of Ivuna and Alais meteorites, and JAXA curation for chips of Ryugu material. This work was funded by NASA ROSES LARS grant 24-LARS24-0014. References: [1] Morlok et al., 2016, GCA 70:5371-5394. [2] Alfin g et al., 2019, Geochemistry 79:125532. [3] Nakamura et al. (2022) Science 379:1-15. [4] Seifert et al. (2026) MAPS 61:504-521. [5] Piralla et al. (2021) MAPS 56:809-828.

CI chondrites↗

PROTECT: Production and Reuse of Thermally Efficient Ceramic Thermal Protection Systems

PROTECT (Production and Reuse Of Thermally Efficient Ceramic TPS) is a NASA Early Career Initiative focused on developing the next generation of reusable ceramic thermal protection systems (TPS). This project addresses key challenges in TPS design, including temperature capability, thermal stability, and refurbishment time, by integrating novel material development with predictive modeling. Leveraging enhanced capabilities in NASA’s Porous Microstructure Analysis (PuMA) software, PROTECT introduces new modeling tools to predict the thermal and mechanical behavior of fibrous ceramic materials. These tools enable accurate prediction of performance metrics such as thermal conductivity and structural integrity, reducing reliance on costly physical testing. Preliminary advances in these areas will be presented. To support model validation, PROTECT is building a comprehensive database of raw material properties using advanced characterization techniques, including micro computed tomography (CT) scanning in collaboration with the University of Illinois Urbana-Champaign (UIUC). The presentation will detail the sampling workflows and analysis methods used to generate this detailed microstructural data and how it is used to develop improved models in PuMA. This multi-center collaboration, spanning NASA (JSC, ARC, KSC, GRC), Oak Ridge National Laboratory, UIUC, and SpaceX, is developing tailored TPS solutions for LEO, lunar, and Martian missions. By bridging heritage systems with the demands of modern spaceflight, PROTECT contributes to the advancement of reusable TPS technologies for future exploration missions.

Propulsion, Refractory, and Coating Materials↗

PROTECT: Production and Reuse of Thermally Efficient Ceramic Thermal Protection Systems

PROTECT (Production and Reuse Of Thermally Efficient Ceramic TPS) is a NASA Early Career Initiative focused on developing the next generation of reusable ceramic thermal protection systems (TPS). This project addresses key challenges in TPS design, including temperature capability, thermal stability, and refurbishment time, by integrating novel material development with predictive modeling. Leveraging enhanced capabilities in NASA’s Porous Microstructure Analysis (PuMA) software, PROTECT introduces new modeling tools to predict the thermal and mechanical behavior of fibrous ceramic materials. These tools enable accurate prediction of performance metrics such as thermal conductivity and structural integrity, reducing reliance on costly physical testing. Preliminary advances in these areas will be presented. To support model validation, PROTECT is building a comprehensive database of raw material properties using advanced characterization techniques, including micro computed tomography (CT) scanning in collaboration with the University of Illinois Urbana-Champaign (UIUC). The presentation will detail the sampling workflows and analysis methods used to generate this detailed microstructural data and how it is used to develop improved models in PuMA. This multi-center collaboration, spanning NASA (JSC, ARC, KSC, GRC), Oak Ridge National Laboratory, UIUC, and SpaceX, is developing tailored TPS solutions for LEO, lunar, and Martian missions. By bridging heritage systems with the demands of modern spaceflight, PROTECT contributes to the advancement of reusable TPS technologies for future exploration missions.

Propulsion, Refractory, and Coating Materials↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence↗

Computing the effective elasticity of anisotropic porous media from X-ray computed micro-tomography images

Development and optimization of composite materials designed for thermal protection of NASA’s spacecraft requires the understanding of their physical response to high-enthalpy environments. To predict their macro-scale properties and behavior, high-fidelity 3D simulations are performed at the micro-scale on realistic representations of these composites. The digital micro-structures are generated either synthetically or through X-ray micro-tomography reconstructions. One of the main challenges in the prediction of heatshield material structural response is the computation of the effective elasticity of the fibrous composite, as well as the understanding of the deformation and stresses generated at the micro-scale. These are driven by the fiber layout within the micro-structure and the distribution of the infused matrix. In this effort, the micro-mechanical linear elastic behavior of fibrous ablators is modeled through the use of a numerical method based on the Multi-Point Stress Approximation (MPSA) finite volume scheme. The MPSA, a generalization of the more commonly used Multi-Point Flux Approximation (MPFA), was discussed in a previous presentation at the 15th USCCN and in reference. To predict the behavior of fibrous and woven architectures, algorithms that compute the local fiber orientation are used. The implementation of the MPSA was verified using analytical solutions, engineering test cases and compared against legacy Finite Element Analysis (FEA) software. The stress analysis models were then applied to real geometries used by NASA in thermal protection systems such as fibrous preforms and woven materials and the results were compared to experimental data.

Federico Semeraro↗

Method for beam hardening correction in quantitative computed X-ray tomography

Each voxel is assumed to contain exactly two distinct materials, with the volume fraction of each material being iteratively calculated. According to the method, the spectrum of the X-ray beam must be known, and the attenuation spectra of the materials in the object must be known, and be monotonically decreasing with increasing X-ray photon energy. Then, a volume fraction is estimated for the voxel, and the spectrum is iteratively calculated.

Yan, Chye Hwang↗

X-ray Micro-Tomography of Ablative Heat Shield Materials

X-ray micro-tomography is a non-destructive characterization technique that allows imaging of materials structures with voxel sizes in the micrometer range. This level of resolution makes the technique very attractive for imaging porous ablators used in hypersonic entry systems. Besides providing a high fidelity description of the material architecture, micro-tomography enables computations of bulk material properties and simulations of micro-scale phenomena. This presentation provides an overview of a collaborative effort between NASA Ames Research Center and Lawrence Berkeley National Laboratory, aimed at developing micro-tomography experiments and simulations for porous ablative materials. Measurements are carried using x-rays from the Advanced Light Source at Berkeley Lab on different classes of ablative materials used in NASA entry systems. Challenges, strengths and limitations of the technique for imaging materials such as lightweight carbon-phenolic systems and woven textiles are discussed. Computational tools developed to perform numerical simulations based on micro-tomography are described. These enable computations of material properties such as permeability, thermal and radiative conductivity, tortuosity and other parameters that are used in ablator response models. Finally, we present the design of environmental cells that enable imaging materials under simulated operational conditions, such as high temperature, mechanical loads and oxidizing atmospheres.Keywords: Micro-tomography, Porous media, Ablation

tomography↗

Volumetric visualization of 3D data

In recent years, there has been a rapid growth in the ability to obtain detailed data on large complex structures in three dimensions. This development occurred first in the medical field, with CAT (computer aided tomography) scans and now magnetic resonance imaging, and in seismological exploration. With the advances in supercomputing and computational fluid dynamics, and in experimental techniques in fluid dynamics, there is now the ability to produce similar large data fields representing 3D structures and phenomena in these disciplines. These developments have produced a situation in which currently there is access to data which is too complex to be understood using the tools available for data reduction and presentation. Researchers in these areas are becoming limited by their ability to visualize and comprehend the 3D systems they are measuring and simulating.

Russell, Gregory↗

Body Imaging

Magnetic Resonance Imaging (MRI) and Computer-aided Tomography (CT) images are often complementary. In most cases, MRI is good for viewing soft tissue but not bone, while CT images are good for bone but not always good for soft tissue discrimination. Physicians and engineers in the Department of Radiology at the University of Michigan Hospitals are developing a technique for combining the best features of MRI and CT scans to increase the accuracy of discriminating one type of body tissue from another. One of their research tools is a computer program called HICAP. The program can be used to distinguish between healthy and diseased tissue in body images.

Source record↗

Three-dimensional, transonic rotor flow field reconstructed from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic flow field of a model rotor blade in hover. A pulsed ruby laser records 40 interferograms with a 61 cm-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates pressure coefficients in several planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations and laser velocimeter measurements at most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Kittleson, J. K.↗

Reconstruction of a 3-dimensional transonic rotor flow field from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2-ft-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in seeral planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Yu, Y. H.↗