Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Particle Imaging Velocimetry Used in a Transonic Compressor Facility

Particle Imaging Velocimetry (PIV) is an optical technique whereby a pulsed laser sheet is used to illuminate particles entrained in a fluid across an extended planar cross section of a flow field. Electronic recording of the particle positions at two closely timed laser pulses permits the computation of the flow velocity. PIV captures the instantaneous flow field, permitting the study of unsteady flow phenomena. Mean flow statistics can be computed by acquiring several hundred images and averaging the results. The first-ever successful application of PIV to acquire measurements in a high-speed rotating turbomachinery blade row was completed in NASA Lewis Research Center's W-8 Single Stage Axial Compressor Facility. Measurements were acquired in a 20-in.-diameter transonic compressor rotor operating at 17,188 rpm. A custom-designed light-sheet generating probe was used to insert the high-energy, pulsed light-sheet illumination required for recording the unblurred images of particles entrained in the fluid. Measurements of the shock wave formed within the rotor blade passage and of unsteady structures within the blade wakes were acquired. These measurements provide insight into unsteady spatial structures in the flow field which cannot be measured with the more conventional laser anemometry technique. The PIV technique provides both instantaneous and average velocity data in a transonic compressor in an order of magnitude less time than required for other conventional optical diagnostic techniques.

Wernet, Mark P.↗

The Multistage Compressor Facility

Research and developments of new aerospace technologies is one of Glenn Research Center's specialties. One facility that deals with the research of aerospace technologies is the High-speed Multistage Compressor Facility. This facility will be testing the performance and efficiency of an Ultra Efficient Engine Technology (UEET) two-stage compressor. There is a lot of preparation involved with testing something of this caliber. Before the test article can be installed into the test rig, the facility must be fully operational and ready to run. Meaning all the necessary instrumentation must be calibrated and installed in the facility. The test rig should also be in safe operating condition, and the proper safety permits obtained. In preparation for the test, the Multistage Compressor Facility went through a few changes. For instance the facility will now be utilizing slip rings, the gearbox went through some maintenance, new lubrications systems replaced the old ones, and special instrumentation needs to be fine tuned to achieve the maximum amount of accurate data. Slips rings help gather information off of a rotating device - in this case from a shaft - onto stationary contacts. The contacts (or brushes) need to be cooled to reduce the amount of frictional heat produced between the slip ring and brushes. The coolant being run through the slip ring is AK-225, a material hazardous to the ozone. To abide by the safety regulations the coolant must be run through a closed chiller system. A new chiller system was purchased but the reservoir that holds the coolant was ventilated which doesn t make the system truly closed and sealed. My task was to design and have a new reservoir built for the chiller system that complies with the safety guidelines. The gearbox had some safety issues also. Located in the back of the gearbox an inching drive was set up. When the inching drive is in use the gears and chain are bare and someone can easily get caught up in it. So to prevent anyone from getting hurt in the gears I designed a chain guard. Additional information is included in the original extended abstract.

Flegel, Ashlie↗

Itegrated Test and Evaluation of a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removtal System (CDRA), Mechanical Compressor Engineering Development Unit (EDU), and Sabitier Engineering Development Unit (EDU)

Currently on the International Space Station s (ISS) U.S. Segment, carbon dioxide (CO2) scrubbed from the cabin by a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removal Assembly (CDRA) is vented overboard as a waste product. Likewise, the product hydrogen (H2) that will be generated by the Oxygen Generation Assembly (OGA) planned for installation will also be vented. A flight experiment has been proposed that will take the waste CO2 removed from the cabin, and via the catalytic Sabatier process, reduce it with waste H2 to generate water and methane. The water produced may provide cost and logistics savings for ISS by reducing the amount of water periodically re-supplied to orbit. To make this concept viable, a mechanical piston compressor and accumulator were developed for collecting and storing the CO2 from the CDRA. The compressor, accumulator and Sabatier system would be packaged together as one unit and referred to as the Carbon Dioxide Reduction Assembly (CRA). Testing was required to evaluate the performance of a 4BMS CDRA, compressor, accumulator, and Sabatier performance along with their operating rules when integrated together. This had been numerically modeled and simulated; however, testing was necessary to verify the results from the engineering analyses. Testing also allowed a better understanding of the practical inefficiencies and control issues involved in a fully integrated system versus the theoretical ideals in the model. This paper presents and discusses the results of an integrated engineering development unit test.

Knox, James C.↗

Compressor Performance Enhanced by Active Flow Control Over Stator Vanes

The application of active flow control technology to enhance turbomachinery system performance is being investigated at the NASA Glenn Research Center through experimental studies. Active flow control involves the use of sensors and actuators embedded within engine components to dynamically alter the internal flow path during off nominal operation in order to optimize engine performance and maintain stable operation. Modern compressors are already highly optimized components that must be designed to accommodate a broad range of operating conditions in a safe and efficient manner. Since overall engine performance is driven by compressor performance, advances in compressor technology that reduce weight and parts count, reduce fuel consumption, and lower maintenance costs will have a significant impact on the cost of aircraft ownership. Active flow control holds the promise of delivering such technology advances.

Culley, Dennis E.↗

Measurement of Flow Pattern Within a Rotating Stall Cell in an Axial Compressor

Effective active control of rotating stall in axial compressors requires detailed understanding of flow instabilities associated with this compressor regime. Newly designed miniature high frequency response total and static pressure probes as well as commercial thermoanemometric probes are suitable tools for this task. However, during the rotating stall cycle the probes are subjected to flow direction changes that are far larger than the range of probe incidence acceptance, and therefore probe data without a proper correction would misrepresent unsteady variations of flow parameters. A methodology, based on ensemble averaging, is proposed to circumvent this problem. In this approach the ensemble averaged signals acquired for various probe setting angles are segmented, and only the sections for probe setting angles close to the actual flow angle are used for signal recombination. The methodology was verified by excellent agreement between velocity distributions obtained from pressure probe data, and data measured with thermoanemometric probes. Vector plots of unsteady flow behavior during the rotating stall regime indicate reversed flow within the rotating stall cell that spreads over to adjacent rotor blade channels. Results of this study confirmed that the NASA Low Speed Axial Compressor (LSAC) while in a rotating stall regime at rotor design speed exhibits one stall cell that rotates at a speed equal to 50.6 percent of the rotor shaft speed.

Lepicovsky, Jan↗

Experimental Investigation of Rotating Stall in a Research Multistage Axial Compressor

A collection of experimental data acquired in the NASA low-speed multistage axial compressor while operated in rotating stall is presented in this paper. The compressor was instrumented with high-response wall pressure modules and a static pressure disc probe for in-flow measurement, and a split-fiber probe for simultaneous measurements of velocity magnitude and flow direction. The data acquired to-date have indicated that a single fully developed stall cell rotates about the flow annulus at 50.6% of the rotor speed. The stall phenomenon is substantially periodic at a fixed frequency of 8.29 Hz. It was determined that the rotating stall cell extends throughout the entire compressor, primarily in the axial direction. Spanwise distributions of the instantaneous absolute flow angle, axial and tangential velocity components, and static pressure acquired behind the first rotor are presented in the form of contour plots to visualize different patterns in the outer (midspan to casing) and inner (hub to mid-span) flow annuli during rotating stall. In most of the cases observed, the rotating stall started with a single cell. On occasion, rotating stall started with two emerging stall cells. The root cause of the variable stall cell count is unknown, but is not attributed to operating procedures.

Lepicovsky, Jan↗

Aerodynamic Inner Workings of Circumferential Grooves in a Transonic Axial Compressor

The current paper reports on investigations of the fundamental flow mechanisms of circumferential grooves applied to a transonic axial compressor. Experimental results show that the compressor stall margin is significantly improved with the current set of circumferential grooves. The primary focus of the current investigation is to advance understanding of basic flow mechanics behind the observed improvement of stall margin. Experimental data and numerical simulations of a circumferential groove were analyzed in detail to unlock the inner workings of the circumferential grooves in the current transonic compressor rotor. A short length scale stall inception occurs when a large flow blockage is built on the pressure side of the blade near the leading edge and incoming flow spills over to the adjacent blade passage due to this blockage. The current study reveals that a large portion of this blockage is created by the tip clearance flow originating from 20% to 50% chord of the blade from the leading edge. Tip clearance flows originating from the leading edge up to 20% chord form a tip clearance core vortex and this tip clearance core vortex travels radially inward. The tip clearance flows originating from 20% to 50% chord travels over this tip clearance core vortex and reaches to the pressure side. This part of tip clearance flow is of low momentum as it is coming from the casing boundary layer and the blade suction surface boundary layer. The circumferential grooves disturb this part of the tip clearance flow close to the casing. Consequently the buildup of the induced vortex and the blockage near the pressure side of the passage is reduced. This is the main mechanism of the circumferential grooves that delays the formation of blockage near the pressure side of the passage and delays the onset of short length scale stall inception. The primary effect of the circumferential grooves is preventing local blockage near the pressure side of the blade leading edge that directly determines flow spillage around the leading edge. The circumferential grooves do not necessarily reduce the over all blockage built up at the rotor tip section.

Hah, Chunill↗

SWIFT Code Assessment for Two Similar Transonic Compressors

One goal of the NASA Fundamental Aeronautics Program is the assessment of computational fluid dynamic (CFD) codes used for the design and analysis of many aerospace systems. This paper describes the assessment of the SWIFT turbomachinery analysis code for two similar transonic compressors, NASA rotor 37 and stage 35. The two rotors have identical blade profiles on the front, transonic half of the blade but rotor 37 has more camber aft of the shock. Thus the two rotors have the same shock structure and choking flow but rotor 37 produces a higher pressure ratio. The two compressors and experimental data are described here briefly. Rotor 37 was also used for test cases organized by ASME, IGTI, and AGARD in 1994-1998. Most of the participating codes over predicted pressure and temperature ratios, and failed to predict certain features of the downstream flowfield. Since then the AUSM+ upwind scheme and the k- turbulence model have been added to SWIFT. In this work the new capabilities were assessed for the two compressors. Comparisons were made with overall performance maps and spanwise profiles of several aerodynamic parameters. The results for rotor 37 were in much better agreement with the experimental data than the original blind test case results although there were still some discrepancies. The results for stage 35 were in very good agreement with the data. The results for rotor 37 were very sensitive to turbulence model parameters but the results for stage 35 were not. Comparison of the rotor solutions showed that the main difference between the two rotors was not blade camber as expected, but shock/boundary layer interaction on the casing.

Chima, Rodrick V.↗

Effect of Various Blade Modifications on Performance of a 16-Stage Axial-Flow Compressor. III - Effect on Over-All Performance Characteristics on Increasing Stator-Blade Angles in Inlet Stages

The stator-blade angles in the first four stages of a 16-stage axial-flow compressor were increased in order to decrease the angles of attack of these stages, and thereby to improve part-speed performance. The performance of this modified compressor was compared with that of the same compressor with original blade angles.

Medeiros, Arthur A.↗

Oscillating-Linear-Drive Vacuum Compressor for CO2

A vacuum compressor has been designed to compress CO2 from approximately equal to 1 psia (approximately equal to 6.9 kPa absolute pressure) to approximately equal to 75 psia (approximately equal to 0.52 MPa), to be insensitive to moisture, to have a long operational life, and to be lightweight, compact, and efficient. The compressor consists mainly of (1) a compression head that includes hydraulic diaphragms, a gas-compression diaphragm, and check valves; and (2) oscillating linear drive that includes a linear motor and a drive spring, through which compression force is applied to the hydraulic diaphragms. The motor is driven at the resonance vibrational frequency of the motor/spring/compression-head system, the compression head acting as a damper that takes energy out of the oscillation. The net effect of the oscillation is to cause cyclic expansion and contraction of the gas-compression diaphragm, and, hence, of the volume bounded by this diaphragm. One-way check valves admit gas into this volume from the low-pressure side during expansion and allow the gas to flow out to the high-pressure side during contraction. Fatigue data and the results of diaphragm stress calculations have been interpreted as signifying that the compressor can be expected to have an operational life of greater than 30 years with a confidence level of 99.9 percent.

Izenson, Michael G.↗

Turbine Engine with Differential Gear Driven Fan and Compressor

A gas turbine engine provides a differential gear system coupling the turbine to the bypass fan and the compressor. In this manner, the power/speed split between the bypass fan and the compressor can be optimized under all conditions. In the example shown, the turbine drives a sun gear, which drives a planet carrier and a ring gear in a differential manner. One of the planet carrier and the ring gear is coupled to the bypass fan, while the other is coupled to the compressor.

Suciu, Gabriel L.↗

Shock Losses in Transonic Compressor Blade Rows

The rather extensive study of the shock losses in transonic compressors can he summarized by the following remarks: 1. A simple flow model can be used to estimate shock losses at the design point for transonic compressor blade rows and results iii reasonable correlation of loss data. It is indicated that shock losses can constitute a sizable portion of the total losses in it transonic compressor rotor. This includes all blade elements at which sonic or higher relative velocities are obtained. 2. Shock losses can he shown to exist across the blade passage (free-stream loss) and by the method of superposition with the blade profile losses result in an estimated design total loss coefficient. 3. The shock configuration was experimentally determined by the rapid pressure rise between the blades as measured by the use of barium titanate crystals. At the minimum loss operating conditions the shock is very similar to that assumed in the simple How model. 4. Shock losses obtained from a more detailed flow model were compared with the losses obtained by the simple flow model. Measured loss distribution from blade to blade closely approaches the analytical shock loss distribution. The measured distribution shows the effect of a shock boundary layer interaction. 5. The analytical method (from the detailed flow model) of determining the shock location ahead of the blade seems to apply reasonably well over a range of incidence angles. The analytical shock losses do not vary a great deal with blade element incidence angles.

Miller, Genevieve R.↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device for a hot water tank utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a tank having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to tanks and pump hydrogen back and forth to form a heat transfer device, such as a hot water heater. A heat transfer device may be coupled with the tank or may comprise the outer surface of the tank to transfer heat to an object or to the surroundings. A closed loop may be configured having two tanks and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a reservoir having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to reservoirs and pump hydrogen back and forth to form a heat transfer device. A heat exchange device may be coupled with the reservoir or may comprise the outer surface of the reservoir to transfer heat to an object or to the surroundings. A closed loop may be configured having two reservoirs and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a reservoir having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to reservoirs and pump hydrogen back and forth to form a heat transfer device. A heat exchange device may be coupled with the reservoir or may comprise the outer surface of the reservoir to transfer heat to an object or to the surroundings. A closed loop may be configured having two reservoirs and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

:investigation of a 24-inch Shock-in-rotor Type Supersonic Compressor Designed for Simple Radial Equilibrium Behind Normal Shock

A 24-inch-diameter shock-in-rotor supersonic compressor rotor designed to obtain simple radial equilibrium behind the normal shock obtained a maximum total-pressure ratio of 2.02 at an adiabatic efficiency of 0.74 and a weight flow of 61.5 pounds per second at design speed. Although this design method considerably reduced the radial forces, there was no apparent reduction in the radial forces, there was no apparent reduction in the radial redistribution of mass flow over the radial redistribution obtained in the previous investigation. This investigation indicates that the shock boundary-layer interaction pattern and associated effects have a very large effect on the radial redistribution of mass flow through the shock-in-rotor supersonic-compressor rotor.

FLOW, SUPERSONIC↗

Analysis of Off-design Performance of a 16-stage Axial-flow Compressor with Various Blade Modifications

The over-all performance of a 16-stage axial-flow compressor was determined with various stator-blade resettings and a reduction in solidity of the rotor blades in the last three stages. It was shown that little control over the sudden change in slope of the surge-limit line at intermediate speeds was obtained with the blade modifications attempted, except that some change in speed at which the change in slope occurred could be effected by stator-blade resettings. Interstage data indicated that the severe surge limit at intermediate speeds was caused by stall of the inlet stage, which, because of stage interaction effects, resulted in a simultaneous decrease in performance of the following five or six stages. Stage data are presented which indicate the flow and pressure-ratio range over which each stage is required to operate at compressor speeds from 50 to 100 percent of design speed.

COMPRESSORS - AXIAL-FLOW↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗