Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collaborative development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

M4SF-20LL010301082-Sorption Database and Model for Generic Disposal System Assessment

This progress report (Level 4 Milestone Number M4SF-20LL010301082) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Argillite International Collaborations Activity Number Activity SF-20LL010301081. The activity is focused on our long-term commitment to engaging our partners in international nuclear waste repository research. The focus of this milestone is surface complexation model international collaborations. Specifically, we are developing a database framework for Spent Fuel and Waste and Science Technology (SFWST) that is aligned with the Helmholtz Zentrum Dresden Rossendorf (HZDR) sorption database development group in support of the database needs of the SFWST program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acciona Power Plant Hydrogen Mitigation Project

In 2014, Acciona Solar Power and the National Renewable Energy Laboratory initiated discussions to identify a method to solve a long-standing efficiency loss problem at parabolic trough power plants. Parabolic trough power plants begin to show lost thermal efficiency after six years of operation, due to the presence of trace concentrations of hydrogen in the heat transfer fluid that circulates in the power plant. Trace levels of hydrogen infiltrate the collector field receivers, increasing their heat loss, and decreasing the power plants’ thermal efficiency. At the time, Acciona’s Nevada Solar One power plant in Boulder City, Nevada was starting to show this efficiency loss. After several discussions, APS and NREL agreed to a collaborative effort (CRADA) to develop and implement a method to reduce hydrogen levels in the circulating HTF at the NSO power plant. The project was planned as a three-year effort, and work started in June 2015. The CRADA’s goal was to solve the long-standing lost efficiency problem caused by the buildup of hydrogen in the HTF, which significantly impacts the efficiency, electricity generation, and revenue from parabolic trough power plants.

08 HYDROGEN↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Explosive Dispersal of Radiological Material: A Nonparametric Analysis

The National Atmospheric Release Advisory Center (NARAC) is a Department of Energy (DOE) asset that provides guidance on the potential effects of atmospherically released hazards based on dispersion simulation results. Numerical simulation results are compared to well-characterized experimental measurements whenever possible to validate and refine the model predictions. In 2012, such measurements were obtained by Defence Research and Development Canada (DRDC) and collaborating organizations for the case of explosively released 140 La – a radioactive isotope with a half-life of 1.6781 days.

42 ENGINEERING↗

Guidelines for Broadband Seismometer Testing

The Comprehensive Nuclear-Test-Ban Treaty mandates the four verification technologies to be used by the International Monitoring System (IMS) to monitor compliance to the Treaty. These technologies are seismic, hydroacoustic, infrasound, and radionuclide. Operational manuals for each of these technologies specify the requirements that equipment installed at IMS stations must meet for data from said stations to be accepted by the International Data Center. Following a model in which a revised set of infrasound sensor specifications and accompanying test procedures were developed in an international collaboration overseen by the Comprehensive Nuclear-Test-Ban Treaty Organization, the same process was recently followed for seismometers potentially of use by the IMS. This document, a product of that collaboration, defines key concepts and recommends test procedures to be followed to characterize broadband seismometers in a consistent and standardized way. Results from these test procedures can be used to verify that a seismometer meets the manufacturers stated specifications and IMS requirements. ACKNOWLEDGEMENTS The writers of this document would like to acknowledge Charles R. Hutt, John R. Evans, Fred Followill, Robert L. Nigbor, and Erhard Wielandt, the authors of the 2009 Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers funded by the U.S. Department of Interior, on which this document is based. Although this document is limited in scope to seismometers and much of the document has been updated, the structure remains essentially the same.

58 GEOSCIENCES↗

Non-Electrostatic Surface Complexation Database for GDSA

This progress report (Level 4 Milestone Number M4SF-21LL010301062) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Argillite International Collaborations Activity Number Activity SF-21LL010301061. The activity is focused on our long-term commitment to engaging our partners in international nuclear waste repository research. The focus of this milestone is surface complexation model international collaborations. Specifically, we are developing a database framework for Spent Fuel and Waste and Science Technology (SFWST) that is aligned with the Helmholtz Zentrum Dresden Rossendorf (HZDR) sorption database development group in support of the database needs of the SFWST program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NNMC–DP Continuing Education Summary [Slides]

DP technicians voiced a desire for more development and learning opportunities. DP management and technician partners identified the opportunity to expand the knowledge of the technicians through employee development to strengthen the collaboration.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MFIX DEM Enhancement for Industry-Relevant Flows (Final Report)

The overall goal of this two-phase project is to implement performance improvements of the Multiphase Flow with Interphase Exchanges (MFIX) Discrete Element Model (DEM) code that enable a transformative shift for industrial use. Prior to this effort, the largest simulations performed using MFIX are O(10 7 ) particles. This falls short of the O(10 9 ) particle simulations that must be completed on a timescale of days or weeks (vs. months or years) to enable simulations with physically-relevant domain sizes to be incorporated into industrial design cycles within five years. This was accomplished by tailoring best-in-class practices to bear on the unique challenges posed by the MFIX-DEM algorithm and code base. Scientific simulations (e.g., in cosmology, turbulent combustion) routinely use massively parallel computing to update far more particles in short wall clock times. Results from Phase 1 (1.5 years in duration) indicated significant gains in speed were possible for a wide range of benchmark cases. Moreover, a survey sent to >35 companies indicates that the timing is ideal for such an enhanced tool, with >80% of the respondents indicating that DEM is already value-added or will be within the next 5 years, and >70% of the respondents indicating that improved speed is the top computational priority. In Phase 2 (3.5 years in duration), the two major barriers that hinder industry from effectively using multiphase Computational Fluid Dynamics (CFD) to cut costs and improve performance, namely computational overhead and confidence in predictions, continued to be addressed. Regarding the former, the results from Phase 1 to guide the effort, with enhancements focused on an improved time-stepping algorithm and particle sorting. Four target problems of 1 billion particles each and increasing complexity were identified: homogeneous cooling, tumbler with continuous particle size distribution, discharge from a rectangular hopper and a cylindrical riser. Each of these were successfully simulated for relevant time scales (on order of seconds) using less than 24 hours of wall clock time. These represent the first 1-billion particle DEM simulations performed with MFIX, namely using the MFIX-Exa code. This code is currently under development at NETL in collaboration with Lawrence Berkeley National Laboratory. Regarding the second barrier on predictive uncertainty, experiments from Phase 1 (interacting nozzles - hydrodynamics only) and Phase 2 (very small-scale segregation experiments) were used to demonstrate the ability of two simplified approaches to uncertainty quantification (UQ). By limiting the number of particles, UQ based on the simplified treatment was compared to standard UQ, which was shown to have much higher computational demands. Experiments were also performed on a pilot-scale stripper unit to provide validation data for future CFD-DEM simulations and UQ.

20 FOSSIL-FUELED POWER PLANTS↗

Capability: Selective Endotoxin Uptake

Researchers at Los Alamos National Lab are developing a new capability to selectively absorb lipopolysaccharide, also known as endotoxin. Current sepsis treatment technologies generally target the bacteria causing the infection, but do not mitigate the host response that causes sickness. This disruptive capability could enable the removal of endotoxin from patient blood adding a much needed tool to the toolkit of sepsis treatments. We are seeking a CRADA partner with the desire to develop sepsis treatments and collaborate on the next steps.

59 BASIC BIOLOGICAL SCIENCES↗

Deep Learning for Fish Identification from Sonar Data: CRADA 481 [Abstract only]

To help solve the challenges of hydropower energy production related to the potential for eel injury and mortality from passage through hydropower turbines, we will develop a deep learning method for identifying migrating eels from imaging sonar. This project continues with a prior project conducted by the Pacific Northwest National Laboratory (PNNL) and the Electric Power Research Institute (EPRI) in FY2018-2019. The proposed method employs Convolution Neural Network (CNN), a powerful deep learning method for image classification, to distinguish between images of eels and non-eel moving objects. We propose to collect more laboratory data and add more existing field data to train a powerful deep learning model. In addition to eels and sticks as classified in previous studies, we will add images containing several non-eel fish species and macrophyte mats to the training data. A multi-class classification model will be developed to distinguish these objects. Object detection algorithm will be explored and developed to locate and identify multiple objects in each sonar frame. Motion analysis will be performed to track the movement of objects in sonar video clips. We will also improve the data conversion algorithm so that it can read in both DIDSON and ARIS (both are imaging sonars developed by Sound Metrics Corp) data files and convert them to images with comparably high resolution, regardless of the varying detection ranges in different environments. The developed algorithms will be packaged as a software with a graphic user interface. The software will be evaluated by external collaborators in the field. The developed framework can be generalized for automatic monitoring of fish passage and migration using other imaging sonars like ARIS and will benefit the design and operation of ecologically friendly hydroelectric projects. The developed wavelet and CNN model configuration parameters can potentially be transferred to lamprey detection in similar riverine environments.

13 HYDRO ENERGY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗