Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Phase-Sensitive Coherence and the Classical-Quantum Boundary in Ghost Imaging

The theory of partial coherence has a long and storied history in classical statistical optics. the vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-sate light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost imaging most closely mimicking those obtained in biphotons, and we derived the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

coherence theory↗

Instrument for in situ hard x-ray nanobeam characterization during epitaxial crystallization and materials transformations

Solid-phase epitaxy (SPE) and other three-dimensional epitaxial crystallization processes pose challenging structural and chemical characterization problems. The concentration of defects, the spatial distribution of elastic strain, and the chemical state of ions each vary with nanoscale characteristic length scales and depend sensitively on the gas environment and elastic boundary conditions during growth. The lateral or three-dimensional propagation of crystalline interfaces in SPE has nanoscale or submicrometer characteristic distances during typical crystallization times. Here, an in situ synchrotron hard x-ray instrument allows these features to be studied during deposition and crystallization using diffraction, resonant scattering, nanobeam and coherent diffraction imaging, and reflectivity. The instrument incorporates a compact deposition system allowing the use of short-working-distance x-ray focusing optics. Layers are deposited using radio-frequency magnetron sputtering and evaporation sources. The deposition system provides control of the gas atmosphere and sample temperature. The sample is positioned using a stable mechanical design to minimize vibration and drift and employs precise translation stages to enable nanobeam experiments. Results of in situ x-ray characterization of the amorphous thin film deposition process for a SrTiO 3 /BaTiO 3 multilayer illustrate implementation of this instrument.

47 OTHER INSTRUMENTATION↗

Room temperature giant magnetostriction in single-crystal nickel nanowires

Magnetostriction is the emergence of a mechanical deformation induced by an external magnetic field. The conversion of magnetic energy into mechanical energy via magnetostriction at the nanoscale is the basis of many electromechanical systems such as sensors, transducers, actuators, and energy harvesters. However, cryogenic temperatures and large magnetic fields are often required to drive the magnetostriction in such systems, rendering this approach energetically inefficient and impractical for room-temperature device applications. Here, we report the experimental observation of giant magnetostriction in single-crystal nickel nanowires at room temperature. We determined the average values of the magnetostrictive constants of a Ni nanowire from the shifts of the measured diffraction patterns using the 002 and 111 Bragg reflections. At an applied magnetic field of 600 Oe, the magnetostrictive constants have values of λ 100 = -0.161% and λ 111 = -0.067%, two orders of magnitude larger than those in bulk nickel. Using Bragg coherent diffraction imaging (BCDI), we obtained the three-dimensional strain distribution inside the Ni nanowire, revealing nucleation of local strain fields at two different values of the external magnetic field. Our analysis indicates that the enhancement of the magnetostriction coefficients is mainly due to the increases in the shape, surface-induced, and stress-induced anisotropies, which facilitate magnetization along the nanowire axis and increase the total magnetoelastic energy of the system.

36 MATERIALS SCIENCE↗

Method for phase retrieval to reduce a sampling requirement when imaging a dynamic process

A method for retrieving phase information in a coherent diffraction imaging process includes acquiring a plurality of 3D data sets, each 3D data set corresponding to one of a plurality of time states, and reconstructing a 3D image of the object at a given time state using the 3D data set from all of the time states. Each 3D data set is acquired by: illuminating an object positioned in a first position with a coherent beam; measuring a first 2D diffraction pattern using an area detector; rotating the object around a tilt axis thereof to a second position that is different from the first position; re-illuminating the object positioned in the second position with the coherent beam; re-measuring a second 2D diffraction pattern using the area detector; and repeating the rotating, re-illuminating and re-measuring steps such that each 3D data set includes a predetermined number of diffraction patterns.

36 MATERIALS SCIENCE↗

Modelling the SIR-B image response to partially coherent seas

A mathematical model of transient seas modulated by coherent swells is developed as a Rayleigh-Poisson random process subject to deterministic correlations of scattering sites, as they appear in a time window defined by a SAR's range-Doppler measurements of the surface coordinates. This model of SAR response to sea surface dynamics is discussed as a Fourier domain predictor/corrector of a dynamic motion blur.

Tilley, D. G.↗

Particle image fields and partial coherence

The accuracy of Young's fringe method for reducing velocity field data is compromized by a spatially incoherent background field which originates in the random locations of the seeding particles. The probability density function for the spatial frequency cutoff of this background is derived as a function of the particle count, the distribution governing the power in each frequency interval is derived, and conditions are found under which the Van Cittert-Zernike theorem applies. The background field resembles the far field of a partially coherent source in the high particle count limit, but departs significantly at low and moderate counts.

Rubinstein, Robert↗

The effect of exit beam phase aberrations on parallel beam coherent x-ray reconstructions

Diffraction artifacts from imperfect x-ray windows near the sample are an important consideration in the design of coherent x-ray diffraction measurements. In this study, we used simulated and experimental diffraction patterns in two and three dimensions to explore the effect of phase imperfections in a beryllium window (such as a void or inclusion) on the convergence behavior of phasing algorithms and on the ultimate reconstruction. A predictive relationship between beam wavelength, sample size, and window position was derived to explain the dependence of reconstruction quality on beryllium defect size. Defects corresponding to this prediction cause the most damage to the sample exit wave and induce signature error oscillations during phasing that can be used as a fingerprint of experimental x-ray window artifacts. The relationship between x-ray window imperfection size and coherent x-ray diffractive imaging reconstruction quality explored in this work can play an important role in designing high-resolution in situ coherent imaging instrumentation and will help interpret the phasing behavior of coherent diffraction measured in these in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Explanation of the Dielectric Enhancement of Barium Titanate Nanoparticles Grown under Hydrothermal Conditions

Abstract When synthesized under certain conditions, barium titanate (BaTiO 3 , BTO) nanoparticles are found to have the non‐thermodynamic cubic structure at room temperature. These particles also have a several‐fold enhanced dielectric constant, sometimes exceeding 6000, and are widely used in thin‐layer capacitors. A hydrothermal approach is used to synthesize BTO nanocrystals, which are characterized by a range of methods, including X‐ray Rietveld refinement and the Williamson–Hall approach, revealing the presence of significant inhomogeneous strain associated with the cubic phase. However, X‐ray pair distribution function measurements clearly show the local structure is lower symmetry than cubic. This apparent inconsistency is resolved by examining 3D Bragg coherent diffraction images of selected nanocrystals, which show the existence of ≈50 nm‐sized domains, which are interpreted as tetragonal twins, and yet cause the average crystalline structure to appear cubic. The ability of these twin boundaries to migrate under the influence of electric fields explains the dielectric anomaly for the nanocrystalline phase.

36 MATERIALS SCIENCE↗

Imaging the Phase Transformation in Single Particles of Lithium Titanate Anode for Lithium-ion Batteries

Lithium uptake and release in lithium titanate (LTO) anode materials during a discharge and charge cycle is one of the fundamental processes of a Lithium-ion battery (LIB), still not fully understood at the microscopic level.During discharge cycle, LTO undergoes a phase transformation between Li 4 Ti 5 O 12 and Li 7 Ti 5 O 12 states within a cubic crystal lattice. To reveal the details of the microscopic mechanism,it is necessary to track the sequence of phase transformation sat different discharge/charge states under operating conditions.Here we use in-situ Bragg Coherent Diffraction Imaging (BCDI) and in-situ X-ray diffraction (XRD) experiments to examine the lithium insertion-induced materials phase transformation within a single LTO particle anda bulk battery analogue,respectively. BCDI analysis from (111) Bragg peak, shows the two-phase transformation manifesting as a distinct image phase modulation within a single LTO nanoparticle occurring in the middle of the discharge region then subsiding towards the end of the discharge cycle. We observe the biggest phase variation at the two-phase stage,indicating the formation of phase domains of 200 nm in size during the discharge process. Additionally, we also observe a lattice contraction of >0.2% in a single LTO nanoparticle at the (400) Bragg peak measurement, larger than that in the corresponding bulk material. Our observation of this phase transformation at a single particle level has implications for the understanding of the microscopic/mesoscale picture of the phase transformation in anode and cathode LIBs materials.

25 ENERGY STORAGE↗

Shadow noise in OCT images of biological tissues

Optical coherence tomography (OCT) images of turbid medium with spatially fluctuating optical parameters demonstrate the presence of spatial noise ('shadow noise') caused by shading of the observed layer by variations in scattering and absorption coefficients of superficial layers. In this paper we report the development of the theoretical model of shadow noise in OCT images in which the features for discriminating this type of noise from the noise of a different origin are determined. Shadow noise is discovered in OCT images of biological tissue after specific image processing and the validity of the developed theoretical model is proven. The role of shadow noise as an interfering factor at imaging the variations in the backscattering coefficient, as well as the source of extra information on optical characteristics of the medium is analysed. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging in real and reciprocal space at the Diamond beamline I13

The Diamond Imaging and Coherence beamline I13 consists of two independent branchlines for imaging in real and reciprocal space. Different microscopies are available providing a range of spatial resolution from 5µm to potentially 5nm. The beamline operates in the energy range of 6-35keV covering different scientific areas such as biomedicine, materials science and geophysics. Several original devices have been developed at the beamline, such as the EXCALIBUR photon counting detector and the combined robot arms for coherent X-ray diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vehicle track identification in synthetic aperture radar images

Various technologies pertaining to identification of vehicle tracks in synthetic aperture radar coherent change detection image data are described herein. Coherent change detection images are analyzed in a parameter space using Radon transforms. Peaks of the Radon transforms correspond to features of interest, including vehicle tracks, which are identified and classified. New coherent change detection images in which the features of interest and their characteristics are signified are then generated using inverse Radon transforms.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-C-18A-04: 3D Markerless Registration of Lung Based On Coherent Point Drift: Application in Image Guided Radiotherapy

Purpose: This study evaluated a new probabilistic non-rigid registration method called coherent point drift for real time 3D markerless registration of the lung motion during radiotherapy. Method: 4DCT image datasets Dir-lab (www.dir-lab.com) have been used for creating 3D boundary element model of the lungs. For the first step, the 3D surface of the lungs in respiration phases T0 and T50 were segmented and divided into a finite number of linear triangular elements. Each triangle is a two dimensional object which has three vertices (each vertex has three degree of freedom). One of the main features of the lungs motion is velocity coherence so the vertices that creating the mesh of the lungs should also have features and degree of freedom of lung structure. This means that the vertices close to each other tend to move coherently. In the next step, we implemented a probabilistic non-rigid registration method called coherent point drift to calculate nonlinear displacement of vertices between different expiratory phases. Results: The method has been applied to images of 10-patients in Dir-lab dataset. The normal distribution of vertices to the origin for each expiratory stage were calculated. The results shows that the maximum error of registration between different expiratory phases is less than 0.4 mm (0.38 SI, 0.33 mm AP, 0.29 mm RL direction). This method is a reliable method for calculating the vector of displacement, and the degrees of freedom (DOFs) of lung structure in radiotherapy. Conclusions: We evaluated a new 3D registration method for distribution set of vertices inside lungs mesh. In this technique, lungs motion considering velocity coherence are inserted as a penalty in regularization function. The results indicate that high registration accuracy is achievable with CPD. This method is helpful for calculating of displacement vector and analyzing possible physiological and anatomical changes during treatment.

60 APPLIED LIFE SCIENCES↗

Evolutionary determination of experimental parameters for ptychographical imaging

The Ptychographical Iterative Engine (PIE) algorithm is a recently developed novel method of Coherent Diffractive Imaging (CDI) that uses multiple overlapping diffraction patterns to reconstruct an image. This method has successfully produced high quality reconstructions at both optical and X-ray wavelengths but the need for accurate knowledge of the probe positions is currently a limiting factor in the production of high resolution reconstructions at electron wavelengths. This paper examines the shape of the search landscape for producing optimal image reconstructions in the specific case of electron microscopy and then shows how evolutionary search methods can be used to reliably determine experimental parameters in the electron microscopy case (such as the spherical aberration in the probe and the probe positions).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose-efficient automatic differentiation for ptychographic reconstruction

Ptychography, as a powerful lensless imaging method, has become a popular member of the coherent diffractive imaging family over decades of development. The ability to utilize low-dose X-rays and/or fast scans offers a big advantage in a ptychographic measurement (for example, when measuring radiation-sensitive samples), but results in low-photon statistics, making the subsequent phase retrieval challenging. Here, we demonstrate a dose-efficient automatic differentiation framework for ptychographic reconstruction (DAP) at low-photon statistics and low overlap ratio. As no reciprocal space constraint is required in this DAP framework, the framework, based on various forward models, shows superior performance under these conditions. It effectively suppresses potential artifacts in the reconstructed images, especially for the inherent periodic artifact in a raster scan. We validate the effectiveness and robustness of this method using both simulated and measured datasets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗