Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Improving Cloud-based Performance of Distribution Planning - Improvements to GridLAB-D

This report provides a high-level summary of the improvements to the GridLAB-D distribution analysis software, including work with GridUnity to focus the areas of improvement and test the final implementation. The improvements allow repetitive, time-series-based simulations, such as renewable hosting capacity studies, to show a 30% or more improvement in execution time. All improvements from this project are available on GridLAB-D’s open-source repository, with most of the changes migrated into the upcoming version 4.3 release of the software.

97 MATHEMATICS AND COMPUTING↗

Hazard Detection Detector Cards

This report presents a comprehensive summary of five advanced anomaly detection tools developed and deployed by Oak Ridge National Laboratory in support of the VA’s Health Information Technology modernization. These detectors—Order Path Tracker, Trend Watcher, Pain Pointer, Performance Monitor, and Patient Record Flag Detector—leverage statistical and machine learning methods to monitor workflow disruptions, detect anomalies in care sequences and volumes, identify bottlenecks, and track system-level performance metrics across VistA and Millennium systems. All detectors have been integrated into the Health Data Analytics Platform (HDAP), with most having completed deployment and testing using live data from targeted stations in cardiology and oncology domains. This work enhances VA’s capacity for proactive system surveillance, promotes patient safety, and informs data-driven operational improvements across the EHR ecosystem.

97 MATHEMATICS AND COMPUTING↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

The Effect of Acetylation on Iron Uptake and Diffusion in Water Saturated Wood Cell Walls and Implications for Decay

Acetylation is widely used as a wood modification process that protects wood from fungal decay. The mechanisms by which acetylation protects wood are not fully understood. With these experiments, we expand upon the literature and test whether previously observed differences in iron uptake by wood were a result of decreased iron binding capacity or slower diffusion. We measured the concentration of iron in 2 mm thick wood sections at 0, 10, and 20% acetylation as a function of time after exposure to iron solutions. The iron was introduced either strongly chelated with oxalate or weakly chelated with acetate. The concentrations of iron and oxalate in solution were chosen to be similar to those found during brown rot decay, while the concentration of iron and acetate matched previous work. The iron content of oxalate-exposed wood increased only slightly and was complete within an hour, suggesting little absorption and fast diffusion, or only slight surface adsorption. The increase in iron concentration from acetate solutions with time was consistent with Fickian diffusion, with a diffusion coefficient on the order of 10 -16 m 2 s -1 . The rather slow diffusion rate was likely due to significant binding of iron within the wood cell wall. The diffusion coefficient did not depend on the acetylation level; however, the capacity for iron absorption from acetate solution was greatly reduced in the acetylated wood, likely due to the loss of OH groups. We explored several hypotheses that might explain why the diffusion rate appears to be independent of the acetylation level and found none of them convincing. Implications for brown rot decay mechanisms and future research are discussed.

54 ENVIRONMENTAL SCIENCES↗

Entropy and crystal-facet modulation of P2-type layered cathodes for long-lasting sodium-based batteries

Abstract P2-type sodium manganese-rich layered oxides are promising cathode candidates for sodium-based batteries because of their appealing cost-effective and capacity features. However, the structural distortion and cationic rearrangement induced by irreversible phase transition and anionic redox reaction at high cell voltage (i.e., >4.0 V) cause sluggish Na-ion kinetics and severe capacity decay. To circumvent these issues, here, we report a strategy to develop P2-type layered cathodes via configurational entropy and ion-diffusion structural tuning. In situ synchrotron X-ray diffraction combined with electrochemical kinetic tests and microstructural characterizations reveal that the entropy-tuned Na 0.62 Mn 0.67 Ni 0.23 Cu 0.05 Mg 0.07 Ti 0.01 O 2 (CuMgTi-571) cathode possesses more {010} active facet, improved structural and thermal stability and faster anionic redox kinetics compared to Na 0.62 Mn 0.67 Ni 0.37 O 2 . When tested in combination with a Na metal anode and a non-aqueous NaClO 4 -based electrolyte solution in coin cell configuration, the CuMgTi-571-based positive electrode enables an 87% capacity retention after 500 cycles at 120 mA g −1 and about 75% capacity retention after 2000 cycles at 1.2 A g −1 .

25 ENERGY STORAGE↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemically Cross-Linked Cellulose Nanocrystal Aerogels for Effective Removal of Cation Dye

In this study, porous aerogels were prepared by directional freeze-drying via cross-linking cellulose nanocrystals (CNCs) with poly(methyl vinyl ether-co-maleic acid) (PMVEMA) and poly(ethylene glycol) (PEG). The thermal properties and physical adsorption performance toward cation methylene blue dye of the obtained CNC aerogels were investigated. The maximum degradation temperature was increased from 324°C of CNCs to 355°C of cross-linked CNC aerogels. The dye adsorption isotherm results showed that the maximum methylene blue adsorption capacity of CNC aerogels was 116.2 mg g −1 , according to the Langmuir model, which was mainly due to the electrostatic attractions between negatively charged carboxyl groups or sulfonate groups on the CNC aerogles and cation MB molecules. The reusability test showed that the CNC aerogels contained the same dye adsorption performance in five adsorption/desorption cycles. Overall, this study described an ideal alternative for water purification with high dye adsorption capacity and enhanced physical performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Report Highlights LAMP's Role as a Robust and Reliable System for Wave Energy Converter Testing

Harnessing the power of waves requires more than just putting devices in the ocean - it takes tools that can refine and accelerate innovation before the first deployment. That's where NLR's largeamplitude motion platform, or LAMP, comes in. LAMP is a six-degree-of-freedom motion system designed to replicate the response of a wave energy converter (WEC) device in realistic ocean conditions. By letting researchers evaluate WEC performance in a safe, controlled lab environment before moving offshore, LAMP helps accelerate innovation while reducing risk. An NLR report, titled Initial Characterization of the NLR LargeAmplitude Motion Platform (https://www.nrel.gov/docs/fy26osti/93733.pdf), provides a deeper understanding of LAMP's capabilities and also lays the groundwork for future advancements in WEC testing methodologies. Researchers studied LAMP's amplitude and frequency limits across different payloads and collected data from 16 test profiles. Testing demonstrated that platform accuracy remained consistent across all payloads evaluated; researchers expect similar accuracy up to LAMP's 10,000-kilogram capacity limit. The measured position limits for single degrees of freedom experienced by WECs, including surge, sway, heave, roll, pitch, and yaw, also exceeded the original manufacturer specifications, providing new insight into the true boundaries of the system.

16 TIDAL AND WAVE POWER↗

Thermophysical Properties Experimentally Tested for NaCl-KCl-MgCl 2 Eutectic Molten Salt as a Next-Generation High-Temperature Heat Transfer Fluids in Concentrated Solar Power Systems

A new eutectic chloride molten salt, MgCl 2 -KCl-NaCl (wt% 45.98–38.91–15.11), has been recognized as one of the most promising high-temperature heat transfer fluids (HTF) for both heat transfer and thermal storage for the third-generation concentrated solar power (CSP) systems. For the first time, some essential thermophysical properties of this eutectic chloride molten salt needed for basic heat transfer and energy storage analysis in the application of concentrating solar power systems have been experimentally tested and provided as functions of temperature in the range from 450 °C to 700 °C. The studied properties include heat capacity, melting point, heat of fusion, viscosity, vapor pressure, density, and thermal conductivity. The property equations provide essential database for engineers to use to calculate convective heat transfer in concentrated solar receivers, heat exchangers, and thermal storage for concentrated solar power plants.

14 SOLAR ENERGY↗

Technology Pathways Could Help Drive the U.S. West Coast Grid's Exposure to Hydrometeorological Uncertainty

Abstract Previous studies investigating deep decarbonization of bulk electric power systems and wholesale electricity markets have not sufficiently explored how future grid pathways could affect the grid's vulnerability to hydrometeorological uncertainty on multiple timescales. Here, we employ a grid operations model and a large synthetic weather ensemble to “stress test” a range of future grid pathways for the U.S. West Coast developed by ReEDS, a well‐known capacity planning model. Our results show that gradual changes in the underlying capacity mix from 2020 to 2050 can cause significant “re‐ranking” of weather years in terms of annual wholesale electricity prices (with “good” years becoming bad, and vice versa). Nonetheless, we find the highest and lowest ranking price years in terms of average electricity price remain mostly tied to extremes in hydropower availability (streamflow) and load (summer temperatures), with the strongest sensitivities related to drought. Seasonal dynamics seen today involving spring snowmelt and hot, dry summers remain well‐defined out to 2050. In California, future supply shortfalls in our model are concentrated in the evening and occur mostly during periods of high temperature anomalies in late summer months and in late winter; in the Pacific Northwest, supply shortfalls are much more strongly tied to negative streamflow anomalies. Under our more robust sampling of stationary hydrometeorological uncertainty, we also find that the ratio of dis‐patchable thermal (i.e., natural gas) capacity to wind and solar required to ensure grid reliability can differ significantly from values reported by ReEDS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methane generation rates from Tank 50 simulant with methylmercury containing saltstone grout solids

This report documents the tests performed to address the requirements listed in the Technical Assistance Request, which resulted in a Test Plan to obtain the required information. To that end the results are documented herein to determine the capacity, and reaction time, for methylmercury (MeHg) contained within Tank 50 salt solution simulant (T50SS) to produce methane when mixed with saltstone dry feed ingredients, as individual components (cement, slag cement, and fly ash) or a combination of those components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Hybrid FPOG Applications in Regulated and Deregulated Markets Using HERON

Recent changes in the U.S. energy market, such as low natural gas prices and increased electricity production for variable renewable energy (VRE) sources, have led to an economic crisis for existing light-water reactor (LWR) nuclear power plants (NPP). Many owners and operators of LWRs have elected to decommission these plants rather than continue using them as consistent sources of clean baseload power. This has led to exploration of various possibilities to increase the economic viability of these units, including market restructuring to monetize benefits LWRs already provide to the grid through ancillary markets, load following and economic dispatch, and possible integration of secondary systems directly to the NPP for production of additional products through technologies such as hydrogen electrolysis or water desalination. Previous studies have considered the technologies associated with these Integrated Energy Systems (IES) activities, and the analysis of markets for these secondary products. To analyze the economic viability of various system configurations including IES, especially given the uncertainty surrounding load demand, electricity prices, and the availability of VRE resources, the stochastic technoeconomic analysis package HERON (Heuristic Energy Resource Optimization Network) was released earlier this year as an extension of the risk analysis framework RAVEN (Risk Analysis Virtual Environment). HERON focuses foremost on making the complex uncertainty quantification analysis tools approachable for energy systems analysts, also providing general dispatch optimization algorithms for those workflows. HERON continues to be improved and tested as a significant part of the IES viability analyses performed in this work. HERON is not a capacity expansion model. To consider market and grid energy system development in a variety of scenarios, HERON is best used in coupling with modelling tools such as US-REGEN, which sacrifice some of the uncertainty analysis and resolution of HERON's modelling for the ability to efficiently predict the change in the grid energy system's profile due to economic drivers over decades. HERON can then use this information to explore the economic viability of introducing changes to the predicted outcomes, such as the introduction of an IES. In this work, experts at EPRI using US-REGEN provide six projection scenarios for use in HERON stochastic technoeconomic analysis (STEA) in considering the options available for increasing LWR economic viability through introduction of a hydrogen-centric IES using a high-temperature steam electrolysis plant (HTSE), hydrogen storage, and a constant-rate contracted hydrogen consumer. The results obtained are differential in nature; they do not report expected profits for any configuration, but rather report on the possible increase in the NPV of a configuration with respect to a baseline no-IES configuration. Due to the uncertainty captured in the variable net load of the systems, there is likewise uncertainty in the mean values reported. We consider this viability both in terms of a regulated market, where the energy producers and IES are owned and operated by single entity, as well as a deregulated market, where the IES chooses its bid for electricity generation and is then dispatched by the grid system operator. Results indicate that for deregulated markets, the inclusion of the IES is often statistically beneficial. This is especially true in policies that are not favorable towards nuclear, as nuclear is less often dispatched and is forced to deal with frequent idle capacity. In the nominal case as well as the case of carbon tax policies, inclusion of the IES clearly benefited the economic performance of the NPP. In the regulated case, however, there was a trend towards minimizing the IES, likely due to the optimal sizing performed by US-REGEN of the NPP within the system as well as the lack of penalty for idle capacity at the NPP in the regulated market analyses.

99 GENERAL AND MISCELLANEOUS↗

High-Speed and Dynamic Diaphragm Compressor for High-Capacity Fueling (Final Technical Report)

Goal of the project is to scale the NEL hydrogen compressor technology from 1.1 kg/minute to 5.5 kg/minute capacity (scale 1:5). This will enable achievement of 330 kg/hour capacity, sufficient to achieve fast high-capacity heavy-duty vehicle (HDV) fueling. The technology readiness level (TRL) maturity objective is to develop and test a scaled-up compressor that is to advance from TRL3 to TRL7.

08 HYDROGEN↗

Organic Iodide Sorption from Dilute Gas Streams

Reprocessing used nuclear fuel releases volatile radionuclides, including 129 iodine (I), into the off-gas of a processing plant. Volatile radioiodine could be present in several forms, depending on the chemistry of the process used and the off-gas stream. Inorganic I 2 is expected to be the predominant I species in the dissolver off-gas (DOG), with minor organic iodides present. The bulk of the I is expected to volatilize into the DOG in parts-per-million-level (ppm) concentrations. In contrast, in the vessel off-gas (VOG), most of the volatile I is expected to be found as organic iodides, such as CH 3 I, C 4 H 9 I, and C 12 H 25 I. These species are expected to be present in parts-per-billion-level (ppb) concentrations but require abatement, even at low expected concentrations, to meet regulatory emissions limits in the United States. Historically, studies of I abatement by Ag-functionalized sorbents have focused on inorganic I in the DOG, but in the last few years, more research attention has been given to organic iodides, especially longer chain species, such as C 4 H 9 I, and C 12 H 25 I. This report has three main goals: (1) to present new data generated at Oak Ridge National Laboratory (ORNL) in FY21 on the sorption behavior of organic iodides on AgZ, (2) to summarize and synthesize organic iodide data produced by ORNL and Idaho National Laboratory (INL) over the last 4 years to answer questions on organic iodides behavior outlined in the 2018 joint test plan (Jubin et al. 2018), and (3) to propose a VOG abatement system design that can provide the capture efficiencies required to meet I emission limits. The 2021 ORNL experimental campaign tested the effects of organic iodide speciation and concentration in the off-gas, superficial velocity of the off-gas, and effects of aging on AgZ sorbent capacity. These studies found that the sorption rate of organic iodides by AgZ depends on the hydrocarbon chain length and the concentration in the off-gas. Higher molecular weight organic iodides adsorb to AgZ more slowly than I. At a concentration of 50 ppm concentration in the off-gas, CH 3 I loads 8% slower, C 4 H 9 I loads 20% slower, and C 12 H 25 I loads 40% slower than I. The lowest concentration loading rates calculated were in 5 ppm organic iodide gas streams in which AgZ gained on average 0.14 mg I/g sorbent/hour in the bench scale test system. Thus, longer sorbent beds might be needed to accommodate slower loading rates onto AgZ in lower concentration gas streams. Although sorption rate varies as a function of hydrocarbon chain length, the saturation concentration of the sorbent for these I-bearing species does not vary. Aging AgZ in a humid air stream for 9 months drops the overall sorbent capacity by ~35% for CH 3 I, ~50% for C 4 H 9 I, and ~40% for C 12 H 25 I. This results in a saturation capacity between 35 and 70 mg I/g sorbent for the aged AgZ. In conjunction with recent data produced by INL, these data are used to estimate the mass transfer zone (MTZ) and decontamination factor (DF) for sorbent beds of AgZ. Sorption tests performed with iodide gas concentrations of about 1 ppm and higher at a superficial gas velocity of 10 m/min, indicate that MTZ depths for these conditions tend to range between about 8-20 cm. Tests performed at lower concentrations between 50-90 ppb and at gas superficial velocities of 1, 10, and 20 m/min indicate that the MTZ depth increases with increasing superficial gas velocity. The 20 m/min test indicates that the MTZ for those conditions was at least 22 cm, and doubling the superficial gas velocity from 10 to 20 m/min could roughly double or triple the MTZ depth. Doubling and tripling the bounding MTZ depth of 20 cm for the body of MTZ estimates made at with 10 m/min superficial velocity would extend the MTZ for a superficial velocity of 20 m/min to 40-60 cm. This bounding limit applies to all of the organic iodides that have been tested. These results also indicate that the sorption rate-limiting step is not sensitive to the superficial gas velocity; otherwise the MTZ depth would not have increased approximately in proportion to the increase in the gas superficial velocity. This further suggests that the rate limiting step is not associated with mass transfer of the sorbate to the sorbent surface, or mass transfer of the reaction byproducts from the sorbent surface, but is associated with sorption or chemical reactions on the sorbent surface or in sorbent pores. Deep bed testing at INL has established DFs of >2,000 for I, CH 3 I, and C 4 H 9 I under a range of conditions (Soelberg et al. 2021, Bruffey et al. 2019). DF does not seem to be affected by the concentration of the organic iodide in the gas stream over the range of 1 to 50 ppm. Thus, if the MTZ is accommodated in sorbent bed design for the DOG and VOG, then regulatory DFs will be met. To meet the third objective outlined in this report, these experimental data were used to update an engineering evaluation of the VOG first completed in 2016. The updated VOG design can be found in an accompanying document (Welty et al., 2021; INL- LTD-21-64587). This report finds that the VOG will decrease in both size and complexity, relative to previous designs, and will still meet regulatory requirements for all iodine forms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid Phase Exfoliation of Chemically Prelithiated Bilayered Vanadium Oxide in Aqueous Media for Li-Ion Batteries

Bilayered vanadium oxides are attractive for energy storage due to their high initial specific capacities, which could be stabilized by integrating the bilayers with conductive nanoflakes often produced in a form of aqueous dispersions. Therefore, exfoliation of the bilayered vanadium oxides in water with high yield is desirable. Here, this work introduces the first aqueous exfoliation of chemically prelithiated bilayered vanadium oxide (i.e., δ-Li x V 2 O 5 ·nH 2 O or LVO) followed by vacuum filtration to produce a free-standing film, exhibiting a lamellar stacking of the bilayered vanadium oxide nanoflakes as evidenced by scanning electron microscopy. Due to the hydrated nature of bilayered vanadium oxides, the relationship between interlayer water content and the vacuum drying temperature (105 °C vs 200 °C) was studied using X-ray diffraction, thermogravimetric analysis, and Raman spectroscopy. It was found that vacuum drying the LVO nanoflakes at 200 °C enabled more efficient removal of crystallographic water than drying at 105 °C, and did not induce a phase transformation. Scanning transmission electron microscopy confirmed the layered structure of the samples, which was more well-ordered in the 200 °C case and had no clear boundaries between flakes at the atomic scale. Furthermore, electrochemical testing in nonaqueous Li-ion cells revealed that vacuum drying at 200 °C led to improvements in ion storage capacity and electrochemical stability. Improvements in electrochemical charge storage properties of the electrodes obtained via LVO exfoliation and free-standing film assembly in water dried at 200 °C reveal that conventional battery electrode drying protocols need to be revised as new electrochemically active materials are synthesized, such as hydrated layered oxides with expanded interlayer regions. The remaining capacity fading can be attributed to the structural LVO degradation, dissolution of vanadium oxide in electrolyte, and parasitic effects of the remaining interlayer water molecules. Our results establish an environmentally friendly and safe approach to obtain two-dimensional (2D) bilayered vanadium oxide nanoflakes and create a pathway to constructing novel 2D heterostructures for improved performance in energy storage applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concealed Cathode Degradation in Lithium-Ion Cells with a Ni-Rich Oxide

Difficulties with sourcing cobalt and the interest in increasing cell energy have motivated the development of Ni-rich oxide materials for lithium-ion battery cathodes. Despite the intense research on the topic, there is limited information available on the long-term performance of novel cathode formulations. Here, we evaluate the stability of LiNi 0.9 Mn 0.05 Co 0.05 O 2 in full-cells tested for over five months, assessing how cycling, voltage and electrolyte additives impact cathode aging. We use differential voltage analysis to extract insights about the cathode from the full-cell data and identify the isolation of cathode particles in the delithiated (charged) state as a relevant mode of aging. Importantly, this particular mechanism of cathode aging does not cause immediate cell capacity fade, causing the simple analysis of cell capacity retention to overestimate the cathode stability under the investigated conditions. So, our observations serve as cautionary tale indicating that careful analysis of data from extended testing may be required for assessing the performance of Ni-rich cathodes and for evaluating how these materials are affected by electrolyte additives.

25 ENERGY STORAGE↗

Market Implications of Alternative Operating Reserve Modeling in Wholesale Electricity Markets

Pricing and settlement mechanisms are crucial for efficient resource allocation, investment incentives, market competition, and regulatory oversight. In the United States, Regional Transmission Operators (RTOs) adopts a uniform pricing scheme that hinges on the marginal costs of supplying additional electricity. This study investigates the pricing and settlement impacts of alternative reserve constraint modeling, highlighting how even slight variations in the modeling of constraints can drastically alter market clearing prices, reserve quantities, and revenue outcomes. Focusing on the diverse market designs and assumptions in ancillary services by U.S. RTOs, particularly in relation to capacity sharing and reserve substitutions, the research examines four distinct models that combine these elements based on a large-scale synthetic power system test data. Our study provides a critical insight into the economic implications and the underlying factors of these alternative reserve constraints through market simulations and data analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗