Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “burgers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Prognostic Implications of MRI-Detected EMVI and Tumor Deposits and Their Response to Neoadjuvant Therapy in cT3 and cT4 Rectal Cancer

Magnetic resonance imaging–detected extramural venous invasion (mrEMVI) and tumor deposits (TDs) are risk factors for the development of local recurrence and distant metastases (DMs) in rectal cancer. However, little is known about their response to neoadjuvant treatment and its relation to oncologic outcomes. This study evaluated the incidence and features of mrEMVI and TDs before and after neoadjuvant treatment in relation to the development of local recurrence and DMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broad SARS-CoV-2 neutralization by monoclonal and bispecific antibodies derived from a Gamma-infected individual

The pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has remained a medical threat due to the evolution of multiple variants that acquire resistance to vaccines and prior infection. Therefore, it is imperative to discover monoclonal antibodies (mAbs) that neutralize a broad range of SARS-CoV-2 variants. A stabilized spike glycoprotein was used to enrich antigen-specific B cells from an individual with a primary Gamma variant infection. Five mAbs selected from those B cells showed considerable neutralizing potency against multiple variants, with COVA309-35 being the most potent against the autologous virus, as well as Omicron BA.1 and BA.2, and COVA309-22 having binding and neutralization activity against Omicron BA.4/5, BQ.1.1, and XBB.1. When combining the COVA309 mAbs as cocktails or bispecific antibodies, the breadth and potency were improved. In addition, the mechanism of cross-neutralization of the COVA309 mAbs was elucidated by structural analysis. Altogether these data indicate that a Gamma-infected individual can develop broadly neutralizing antibodies.

60 APPLIED LIFE SCIENCES↗

Advanced high-performance large diameter Cs 2 HfCl 6 (CHC) and mixed halides scintillator

This paper reports on successful growth and performance evaluation of two large diameter Cs 2 HfCl 6 (CHC) and Cs 2 HfCl 4 Br 2 (CHCB), both recently developed scintillator crystals. The discovery of Cs 2 HfCl 6 (CHC) as a scintillator has lately generated much interest in this material and its family, which belongs to the K 2 PtCl 6 cubic crystal structure. CHC is an intrinsic scintillator that is non-hygroscopic (slightly deliquescent, i.e., slightly moisture sensitive but does not deteriorate much when left in air), has no self-radioactivity, provides excellent energy resolution, and has excellent non-proportionality. CHC has a moderate density of 3.9 g/cm 3 and an effective atomic number of 58. Reported in this paper are transparent crack-free single crystal CHC and CHCB boules of one inch in diameter, both grown using the vertical Bridgman method. Samples retrieved from the boules, sized 23 mm × 30 mm and 23 mm × 26 mm, respectively, are characterized for their optical and scintillation properties. Energy resolutions of 3.5% and 3.7% (FWHM) at 662 keV, respectively, are reported. Light yields of 23,000 ph/MeV and 20,000 ph/MeV have been calculated for the large diameter CHC and CHCB crystals, respectively. Results comparable to previously reported results for smaller crystals have been obtained. Studies on decay time, non-proportionality, as well as detector characterization are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-induced negative optical nonlinearities in fused silica, sapphire, and borosilicate glass

Here, negative nonlinear absorption is reported in neutron- and gamma-irradiated high-OH content fused silica, low-OH content fused silica, sapphire, borosilicate glass, and radiation-resistant borosilicate glass irradiated to total neutron fluences of 3.4 × 10 16 n ∙ cm –2 (42 Mrad γ), 1.7 × 10 17 n ∙ cm –2 (211 Mrad γ), and 3.6 × 10 17 n ∙ cm –2 (433 Mrad γ). Nonlinear absorption coefficients were measured via Z-scan and are on the order of – (10 –14 –10 –10 ) m∙W –1 . The Z-scan also reveals a negative nonlinear index of refraction in neutron- and gamma-irradiated radiation-resistant borosilicate glass on the order of –10 –19 m 2 ∙ W –1 . Thermal annealing at temperatures up to 800 °C is shown to restore these nonlinearities to their positive unirradiated values in all four materials. All Z-scan measurements were performed at 532 nm with a nanosecond pulsed laser. The occurrence of negative nonlinearities may be attributed to the presence of metallic impurities and the resulting saturable absorption. A limited effect of photobleaching is observed in measurements and is quantified in multiple Z-scans.

36 MATERIALS SCIENCE↗

Approximation rates of DeepONets for learning operators arising from advection–diffusion equations

Here we present the analysis of approximation rates of operator learning in Chen and Chen (1995) and Lu et al. (2021), where continuous operators are approximated by a sum of products of branch and trunk networks. In this work, we consider the rates of learning solution operators from both linear and nonlinear advection–diffusion equations with or without reaction. We find that the approximation rates depend on the architecture of branch networks as well as the smoothness of inputs and outputs of solution operators.

97 MATHEMATICS AND COMPUTING↗

First evaluation of fast neutron imaging with LiInSe 2 semiconductors

Fast neutron imaging is a powerful tool to investigate elemental/isotopic compositions of objects, supporting both scientific studies as well as cargo scanning. Current neutron imaging systems are faced with challenges associated with timing, detection efficiency, and/or spatial resolution. Here, we report on the use of a semiconducting lithium indium diselenide neutron sensor coupled to a Timepix ASIC for fast neutron imaging. Using a 15 cm thick copper knife edge, the spatial resolution of the neutron imager was found to be 1.55 mm for 9 MeV neutrons. In conclusion, the experimental detection efficiency at 9 MeV was in general agreement with calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium indium diselenide — An advanced material for neutron detection

Here, this paper describes the synthesis, crystal growth, detector fabrication, radiation hardening studies, MCNP modeling, and characterization of lithium indium diselenide or LiInSe 2 . This newly-developed room temperature thermal neutron detector has semiconducting and scintillating properties and it is suitable for neutron detection application. LiInSe 2 was synthesized starting from elemental Li, In, Se in two steps due to high reactivity of Li. A single crystal of LiInSe 2 was grown using the Vertical Bridgman method. The room temperature band gap was found to be 2.8 eV using optical absorption measurements. Bulk resistivity was measured at ∼5 × 10 11 Ωcm. Photoconductivity measurements of LiInSe 2 wafers identified a peak in the photocurrent around 445 nm. Nuclear radiation detectors were fabricated from single crystal wafer and the responses to alpha particles at various biases were measured. The mobility-lifetime product was estimated. Gamma irradiation studies were performed with calculated absorbed doses ranging from 0.2126 to 21,262 Gy. The characterization of the two wafers for their scintillator performance was conducted after each irradiation. The gamma irradiation produced a reduction of the light yield that translated to a lower channel number for the centroid of alpha detection spectra. It also showed a considerable reduction of the decay time after the first irradiation. These are the first studies on gamma radiation hardening with this material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural network-based control of an ultrafast laser

With the recent advances in machine learning (ML) and data science (DS), the control, modeling, and analysis of these complex systems continues to improve. In this work, we report on the optimization of the intensity of a femtosecond laser using feedforward neural networks (FFNN) that model the input–output relationships of the data. The input parameters of the system were optimized to achieve the required performance of the femtosecond laser. We propose a neural network-based control system to model the relationship between the spectral amplitude and phase of the input laser pulse at the amplifier input and the shape of the output pulse. Low-jitter laser parameter inputs and the resulting laser pulse duration were modeled, and the resulting correlation between the input and output data was used to optimize the laser pulse. Here, we demonstrate improved processing and laser control performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Filament-induced breakdown spectroscopy signal enhancement using optical wavefront control

Filament-induced breakdown spectroscopy (FIBS) is an analytical method that holds significant promise for remote sensing. In FIBS, it is desirable to maximize the intensity and improve the reproducibility of a selected spectroscopic feature. Here, we demonstrate the use of wavefront control in conjunction with a genetic algorithm in FIBS of metallic copper and show that this approach can increase the efficacy of filament-induced breakdown signal production. Through wavefront optimization, we enhance the intensity of a chosen characteristic spectroscopic feature of copper by a factor of approximately 3 when performing filamentation over a 1-meter distance. The relative standard deviation of signal intensity is reduced from ~17% to ~12% after optimization. We find that modification of the wavefront by introduction of astigmatism and coma maximizes the signal intensity, and these aberrations appear in two distinct trials of the genetic algorithm. We compare these findings to previous work on multiple filament control and discuss the possible mechanisms that lead to signal enhancement associated with both the beam amplitude and phase profile. A broader use of wavefront control with feedback may improve the performance of FIBS in remote sensing applications.

42 ENGINEERING↗

Hot-pressed 6 LiInSe 2 for use as a ceramic radiation detector

Lithium based chalcogenides have many uses in the nuclear science field. 6 LiInSe 2 (or LISe) has been researched extensively because of its ability to operate in both scintillator and semiconductor modes. Here, this makes it useful in applications including nuclear material detection for national security, space applications, and medical imaging. In some applications growth and fabrication costs are of concern, as it takes upwards of 40 days to synthesize a charge, grow a crystal and fabricate a detector. Ceramics are a solution for this long route of preparation. This research shows that using a 6 LiInSe 2 ceramic instead of a single crystal significantly decreases the time required to make a detector. In the present work, ceramic wafers can be formed using a mechanical press equipped with a heating attachment. The resulting ceramic wafer performs very similar to a slow-growth single crystal when used in the scintillator mode.

36 MATERIALS SCIENCE↗

Advanced inorganic halide ceramic scintillators

Research in ceramic scintillators has steadily progressed alongside the research in bulk single crystal scintillator growth. As interest in faster scintillation material production with lower cost increases, more research on scintillating ceramics is needed. Research targeting optimization of optically transparent ceramics that can rival bulk-grown crystals grown may lower cost, increase yield, increase volume, and improve energy resolution in applications and systems currently using sodium iodide and alike. Ceramic scintillators that are dense (>5 g/cm 3 ), have high effective Z (>60), are bright (>40,000 photons/MeV), and are not sensitive to moisture as well as those that can be handled without protection are desired. Ultra-fast ceramic materials are also of interest. This paper presents an equipment design and technique to produce inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Improvements and optimization of CHC and THC ceramic scintillator fabrication are gauged by monitoring the energy resolution and peak position of 137 Cs full energy peak at 662 keV. With a 1-inch diameter CHC ceramic scintillator, energy resolution of 5.4% (FWHM) and light yield of 20,700 ph/MeV are achieved, while with a 16-mm diameter THC ceramic scintillator, energy resolution of 5.1% (FWHM) and light yield of 27,800 ph/MeV are achieved. Decay times of 0.6 μs (21%) and 3.0 μs (79%) are measured for CHC and 0.3 μs (13%) and 1.0 μs (87%) for THC. Here, both ceramic CHC and THC scintillators have similarly good proportionality data when compared to their single crystal counterparts.

36 MATERIALS SCIENCE↗

Plasma-assisted chemical-looping combustion: Mechanistic insights into low temperature methane oxidation with CuO

The low-temperature oxidation of CH 4 by CuO in a coaxial, fixed bed, double dielectric barrier discharge (DBD) reactor was investigated with time-dependent species measurements by an electron-ionization molecular beam mass spectrometer (EI-MBMS). In the experiment, 10% methane carried by noble gasses was flown at 50 sccm through 1 g CuO dispersed in quartz wool both under plasma and non-plasma conditions, while time-dependent gas-phase species profiles were collected. Plasma conditions were explored from 300 to 600 °C while the non-plasma conditions were set from 300 to 900 °C. Mechanistic insights into the oxidation of CH 4 by CuO with plasma discharge at lower temperatures (≤ 600 °C) were obtained by quantifying the fuel oxidation, intermediate species, and CO 2 production in comparison to the non-plasma conditions. Here, we observed significant enhancement of fuel oxidation from the plasma discharge between 400 and 500 °C. The CO 2 production at 500 °C with plasma was greater than that at 700 °C without plasma, reducing fuel oxidation temperature by 200+ °C. During tests, three distinct reaction stages were observed: a gas-phase transport limited stage, a surface reaction limited kinetic stage, and an oxygen ion diffusion limited stage. It was observed that plasma greatly improved the reactivity of the second stage at low temperature. In addition, no carbon deposits were observed on the resultant particles, even under the presence of plasma. M. species such as C 4 H 2 and C 6 H 6 not previously observed or predicted in CuO/CH 4 chemical looping were observed, with some species such as CH 3 OH only becoming detectable as total flowrate was increased from 50 to 1500sccm. A non-plasma reaction pathway for CH 4 based the observed species from the MBMS spectrum and previous predictions from reactive molecular dynamics simulations was created, providing a framework from which more complex plasma CuO mechanisms can be crafted from.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active control of laser beam pointing for the Zettawatt-Equivalent Ultrashort pulse laser System: a proof-of-principle study with 16-inch optics

We present a proof-of-principle study of active beam-pointing control for the Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) using a piezo-actuated 16-inch mirror. To the best of our knowledge, this is the largest actively controlled mirror reported in a high-power laser system. A simple proportional feedback control was implemented based on a field-programmable gate array, which reduced the standard deviation of beam-pointing fluctuations by 91% to 0.075 μrad in the horizontal direction and by 78% to 0.25 μrad in the vertical direction. We also demonstrated the elimination of long-term pointing jitter caused by temperature drift using the same apparatus.

laser pointing control↗