Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blind systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Reliable and practical computational description of molecular crystal polymorphs

Reliable prediction of the polymorphic energy landscape of a molecular crystal would yield profound insight into drug development in terms of the existence and likelihood of late-appearing polymorphs. However, the computational prediction of molecular crystal polymorphs is highly challenging due to the high dimensionality of conformational and crystallographic space accompanied by the need for relative free energies to within 1 kJ/mol per molecule. In this study, we combine the most successful crystal structure sampling strategy with the most successful first-principles energy ranking strategy of the latest blind test of organic crystal structure prediction methods. Specifically, we present a hierarchical energy ranking approach intended for the refinement of relative stabilities in the final stage of a crystal structure prediction procedure. Such a combined approach provides excellent stability rankings for all studied systems and can be applied to molecular crystals of pharmaceutical importance.

36 MATERIALS SCIENCE↗

ESM data downscaling: a comparison of super-resolution deep learning models

Abstract Climate projections at fine spatial resolutions are required to conduct accurate risk assessment for critical infrastructure and design adaptation planning. Generating these projections using advanced Earth system models (ESM) requires significant computational resources. To address this issue, various statistical downscaling techniques have been introduced to generate fine-resolution data from coarse-resolution simulations. In this study, we evaluate and compare five deep learning-based downscaling techniques, namely, super-resolution convolutional neural networks, fast super-resolution convolutional neural network ESM, efficient sub-pixel convolutional neural network, enhanced deep residual network (EDRN), and super-resolution generative adversarial network (SRGAN). These techniques are applied to a dataset generated by the Energy Exascale Earth System Model (E3SM), focusing on key surface variables such as surface temperature, shortwave heat flux, and longwave heat flux. Models are trained and validated using paired fine-resolution (0.25 $$^{\circ }$$ ∘ ) and coarse-resolution (1 $$^{\circ }$$ ∘ ) monthly data obtained from a 9-year simulation. Next, blind testing is performed using monthly data obtained from two different years outside of the training and validation set. To evaluate the efficiency of each technique, different statistical metrics are used, including mean squared error (MSE), peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and learned perceptual image patch similarity (LPIPS). The results show that EDRN outperforms other algorithms in terms of PSNR, SSIM, and MSE, but struggles to capture fine-scale features in the data. In contrast, SRGAN, a generative model that uses perceptual loss, excels in capturing fine details at boundaries and internal structures, resulting in lower LPIPS than other methods.

Pawar, Nikhil M. (ORCID:0000000211613289)↗

A Phase III, Double-Blind, Placebo-Controlled Prospective Randomized Clinical Trial of d-Threo-Methylphenidate HCl in Brain Tumor Patients Receiving Radiation Therapy

Purpose: The quality of life (QOL) and neurocognitive function of patients with brain tumors are negatively affected by the symptoms of their disease and brain radiation therapy (RT). We assessed the effect of prophylactic d-threo-methylphenidate HCl (d-MPH), a central nervous system (CNS) stimulant on QOL and cognitive function in patients undergoing RT. Methods and Materials: Sixty-eight patients with primary or metastatic brain tumors were randomly assigned to receive d-MPH or placebo. The starting dose of d-MPH was 5 mg twice daily (b.i.d.) and was escalated by 5 mg b.i.d. to a maximum of 15 mg b.i.d. The placebo was administered as one pill b.i.d. escalating three pills b.i.d. The primary outcome was fatigue. Patients were assessed at baseline, the end of radiation therapy, and 4, 8, and 12 weeks after brain RT using the Functional Assessment of Cancer Therapy with brain and fatigue (FACIT-F) subscales, as well as the Center for Epidemiologic Studies Scale and Mini-Mental Status Exam. Results: The Mean Fatigue Subscale Score at baseline was 34.7 for the d-MPH arm and 33.3 for the placebo arm (p = 0.61). At 8 weeks after the completion of brain RT, there was no difference in fatigue between patient groups. The adjusted least squares estimate of the Mean Fatigue Subscale Score was 33.7 for the d-MPH and 35.6 for the placebo arm (p = 0.64). Secondary outcomes were not different between the two treatment arms. Conclusions: Prophylactic use of d-MPH in brain tumor patients undergoing RT did not result in an improvement in QOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Assessment of Manual Ultrasonic Examinations Applied to Detect Flaws in Primary System Dissimilar Metal Welds at North Anna Power Station

PNNL conducted a technical assessment of the NDE issues and protocols that led to missed detections of several axially oriented flaws in a steam generator primary inlet dissimilar metal weld at North Anna Power Station, Unit 1 (NAPS-1). This particular component design exhibits a significant outside-diameter (OD) taper that is not included as a blind performance demonstration mock-up within the industry’s Performance Demonstration Initiative, administered by EPRI. For this reason, the licensee engaged EPRI to assist in the development of a technical justification to support the basis for a site-specific qualification. The service-induced flaws at NAPS-1 were eventually detected as a result of OD surface machining in preparation for a full structural weld overlay. The machining operation uncovered the existence of two through-wall flaws, based on the observance of primary water leaking from the dissimilar metal weld. A total of five axially oriented flaws were detected in varied locations around the weld circumference. The field volumetric examination that was conducted at NAPS-1 was a non-encoded, real-time manual ultrasonic examination. PNNL conducted both an initial assessment, and subsequently, a more rigorous technical evaluation (reported here), which has identified an array of NDE issues that may have led to the subject missed detections. These evaluations were performed through technical reviews and discussions with NRC staff, EPRI NDE Center personnel, industry and ISI vendor personnel, and ultrasonic transducer manufacturers, and laboratory tests, to better understand the underlying issues at North Anna.

cracks↗

J-GEM optical and near-infrared follow-up of gravitational wave events during LIGO’s and Virgo’s third observing run

The Laser Interferometer Gravitational-wave Observatory Scientific Collaboration and Virgo Collaboration (LVC) sent out 56 gravitational-wave (GW) notices during the third observing run (O3). The Japanese Collaboration for Gravitational wave ElectroMagnetic follow-up (J-GEM) performed optical and near-infrared observations to identify and observe an electromagnetic (EM) counterpart. We constructed a web-based system that enabled us to obtain and share information on candidate host galaxies for the counterpart, and the status of our observations. Candidate host galaxies were selected from the GLADE catalog with a weight based on the 3D GW localization map provided by LVC. We conducted galaxy-targeted and wide-field blind surveys, real-time data analysis, and visual inspection of observed galaxies. We performed galaxy-targeted follow-ups to 23 GW events during O3, and the maximum probability covered by our observations reached 9.8%. Among these, we successfully started observations for 10 GW events within 0.5 days after the detection. This result demonstrates that our follow-up observation has the potential to constrain EM radiation models for a merger of binary neutron stars at a distance of up to ~100 Mpc with a probability area of ≤ 500 deg 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Probiotic Lactobacillus Casei DN-114 001 in Prevention of Radiation-Induced Diarrhea: Results From Multicenter, Randomized, Placebo-Controlled Nutritional Trial

Purpose: To determine whether a probiotic drink containing Lactobacillus casei DN-114 001 reduces the incidence of radiation-induced diarrhea in patients with gynecologic cancer. Methods and Materials: Patients who were undergoing pelvic radiotherapy (45-50 Gy, conventional fractionation) for either cervical carcinoma (radiotherapy and weekly cisplatin) or endometrial adenocarcinoma (postoperative radiotherapy) were randomly assigned to a probiotic drink or placebo, in a double-blind fashion. The probiotic drink consisted of liquid yogurt containing L. casei DN-114 001 at 10{sup 8} CFU/g. The patients recorded the daily the number of bowel movements and scored the stool consistency using the Bristol scale. Diarrhea was graded weekly according the Common Toxicity Criteria system. The primary endpoint was to reduce the incidence of diarrhea, defined by a Common Toxicity Criteria Grade of 2 or greater or the need for loperamide. Results: A total of 85 patients were enrolled. Grade 2 or greater diarrhea and/or the use of loperamide was observed in 24 of 41 patients in the placebo group and 30 of 44 in the probiotic group (p = 0.568). No differences were found in the median time to the presentation of the primary endpoint. Probiotic intervention had a significant effect on stool consistency (p = 0.04). The median time for patients to present with Bristol scale stools of Type 6 or greater was 14 days for patients receiving the probiotic drink vs. 10 days for those receiving placebo. Conclusion: Nutritional intervention with the probiotic drink containing L. casei DN-114 001 does not reduce the incidence of radiation-induced diarrhea as defined by a Common Toxicity Criteria Grade 2 or greater. However, it had a significant effect on stool consistency as measured by the Bristol scale.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Future Aviation Biofuel Analysis Using the Biomass Scenario Model

This presentation summarizes the findings from two articles that use the Biomass Scenario Model (BSM) to explore potential future aviation biofuels scenarios. Newes et al. (2017) concluded that construction/build out capabilities and development of the feedstock market are key bottlenecks in the initial years. Displacement of jet fuel by 30% with biofuels by 2030 is possible, but several factors related to policy design-in the absence of high oil prices or policy uncertainty-contribute to the timing and magnitude of aviation biofuels production. First, incentives targeted toward jet fuel production, such as financial incentives (e.g., a producer tax credit or a CO2 tax) could be sufficient to reach six billion gallons. Second, R&D investment in pre-commercial technologies is needed to reduce the cost of production through learning-by-doing. Third, reduction of investment risk through loan guarantees and offtake agreements may allow production to ramp up more quickly through accelerating industry learning. Lewis et al. (2018) showed that both BSM and the Freight and Fuel Transportation Optimization Tool suggest that 200 million to 1 billion gallons per year of alternative jet fuel production are possible by 2030, given multiple incentives and a favorable investment climate. However, different capital costs and technology maturation rates in the two models will affect deployment of different fuel production technologies and therefore the feedstocks needed. Further collaboration on these modeling approaches would reduce methodological blind spots while providing insights into future industry trajectories.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Standardisation of radiation portal monitor controls and readouts

There is an urgent need to standardise the numbering configuration of radiation portal monitor sensing panels. Currently, manufacturers use conflicting numbering schemes that may confuse operators of these varied systems. There is a similar problem encountered with the varied choices of colored indicator lights and colored print lines designated for gamma and neutron alarms. In addition, second-party software that changes the alarm color scheme may also have been installed. Furthermore, no provision exists for the color blind or to provide work stations with only black ink on alarm printouts. These inconsistencies and confusing setups could inadvertently cause a misinterpretation of the alarm, resulting in the potential release of a radiological hazard into a sovereign country. These issues are discussed, and a proposed solution is offered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-Blind Quantification of Natural Gas Leaks from 1 km Distance Using Frequency Combs

A new method is tested in a single-blind study for detection, attribution, and quantification of methane emissions from the natural gas supply chain, which contribute substantially to annual U.S. emissions. The monitoring approach couples atmospheric methane concentration measurements from an open-path dual frequency comb laser spectrometer with meteorological data in an inversion to characterize emissions. During single-blind testing, the spectrometer is placed >1 km from decommissioned natural gas equipment configured with intentional leaks of control- lable rate. Single, steady emissions ranging from 0 to 10.7 g min -1 (0-34.7 scfh) are detected, located, and quantified at three gas pads of varying size and complexity. The system detects 100% of leaks, including leaks as small as 0.96 g min -1 (3.1 scfh). It attributes leaks to the correct pad or equipment group (tank battery, separator battery, wellhead battery) 100% of the time and to the correct equipment (specific separator, tank, or wellhead) 67% of the time. All leaks are quantified to within 3.7 g min -1 (12 scfh); 94% are quantified to within 2.8 g min -1 (9 scfh). Finally, these tests are an important initial demonstration of the methodology’s viability for continuous monitoring of large regions, with extension to other trace gases and industries.

03 NATURAL GAS↗

Interrater Reliability of the Categorization of Late Radiographic Changes After Lung Stereotactic Body Radiation Therapy

Purpose: Radiographic changes after lung stereotactic body radiation therapy (SBRT) have been categorized into 4 groups: modified conventional pattern (A), mass-like fibrosis; (B), scar-like fibrosis (C), and no evidence of increased density (D). The purpose of this study was to assess the interrater reliability of this categorization system in patients with early-stage non-small cell lung cancer (NSCLC). Methods and Materials: Seventy-seven patients were included in this study, all treated with SBRT for early-stage (T1/2) NSCLC at a single institution, with a minimum follow-up of 6 months. Six experienced clinicians familiar with post-SBRT radiographic changes scored the serial posttreatment CT images independently in a blinded fashion. The proportion of patients categorized as A, B, C, or D at each interval was determined. Krippendorff's alpha (KA), Multirater kappa (M-kappa), and Gwet's AC1 (AC1) scores were used to establish interrater reliability. A leave-one-out analysis was performed to demonstrate the variability among raters. Interrater agreement of the first and last 20 patients scored was calculated to explore whether a training effect existed. Results: The number of ratings ranged from 450 at 6 months to 84 at 48 months of follow-up. The proportion of patients in each category was as follows: A, 45%; B, 16%; C, 13%; and D, 26%. KA and M-kappa ranged from 0.17 to 0.34. AC1 measure range was 0.22 to 0.48. KA increased from 0.24 to 0.36 at 12 months with training. The percent agreement for pattern A peaked at 12 month with a 54% chance of having >50% raters in agreement and decreased over time, whereas that for patterns B and C increased over time to a maximum of 20% and 22%, respectively. Conclusion: This post-SBRT radiographic change categorization system has modest interrater agreement, and there is a suggestion of a training effect. Patterns of fibrosis evolve after SBRT and alternative categorization systems should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machined phononic crystals to block high-order Lamb waves and crosstalk in through-metal ultrasonic communication systems

For systems that require complete metallic enclosures (e.g., containment buildings for nuclear reactors), it is impossible to access interior sensors and equipment using standard electromagnetic techniques. A viable way to communicate and supply power through metallic barriers is the use of elastic waves and ultrasonic transducers, introducing several design challenges that must be addressed. Specifically, the use of multiple communication channels on the same enclosure introduces an additional mechanism for signal crosstalk between channels: guided waves propagating in the barrier between channels. This work numerically and experimentally investigates a machined phononic crystal to block MHz Lamb wave propagation between ultrasonic communication channels, greatly reducing wave propagation and the resulting crosstalk voltage. Blind grooves are machined into one or both sides of a metallic barrier to introduce a periodic unit cell, greatly altering the guided wave dispersion in the barrier. Numerical simulations are used to determine a set of groove geometries for testing, and experiments were performed to characterize the wave-blocking performance of each design. The best-performing design was tested using piezoelectric transducers bonded to the barrier, showing a 14.4 dB reduction in crosstalk voltage. Overall, the proposed periodic grooving method is a promising technique for completely isolating ultrasonic power/data transfer systems operating in a narrow frequency range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A case study evaluating the portability of an executable computable phenotype algorithm across multiple institutions and electronic health record environments

Abstract Electronic health record (EHR) algorithms for defining patient cohorts are commonly shared as free-text descriptions that require human intervention both to interpret and implement. We developed the Phenotype Execution and Modeling Architecture (PhEMA, http://projectphema.org) to author and execute standardized computable phenotype algorithms. With PhEMA, we converted an algorithm for benign prostatic hyperplasia, developed for the electronic Medical Records and Genomics network (eMERGE), into a standards-based computable format. Eight sites (7 within eMERGE) received the computable algorithm, and 6 successfully executed it against local data warehouses and/or i2b2 instances. Blinded random chart review of cases selected by the computable algorithm shows PPV ≥90%, and 3 out of 5 sites had >90% overlap of selected cases when comparing the computable algorithm to their original eMERGE implementation. This case study demonstrates potential use of PhEMA computable representations to automate phenotyping across different EHR systems, but also highlights some ongoing challenges.

Pacheco, Jennifer A.↗

Towards a predictive, physics-based friction model for the dynamics of jointed structures

Bolted connections are ubiquitous in mechanical designs and pose a significant challenge to understanding and predicting the vibration response of assembled structures. The present paper develops a physics-based rough contact model of the frictional interactions within a joint. This model sums over the probable interactions of asperities – defined as locally maximum surface features – to determine the contact forces. Here, the tangential contact forces vary smoothly between sticking and slipping and allow the model to better capture the qualitative trends of experimental amplitude dependent frequency and damping than previous studies. Furthermore, the novel model is generalized to allow for arbitrarily varying normal pressure including potential separation to better represent the interfacial dynamics. This includes developing a new, computationally tractable approximation to the analytical Mindlin partial slip solution for tangential loading of contacting spheres. Further, the results highlight the importance of accurately characterizing the as-built topology of the interface, the plastic behavior of the contacting asperities, the relevant length scale of asperities, and the eccentricity of asperities. A predictive friction coefficient based on plasticity provides a poor match to experiments, so fitting the friction coefficient is also considered. Numerical results are compared to experiments on the Brake-Reuß Beam to assess the predictive potential of the models. While blind predictions over-predict the slip limit, the current model presents a significant improvement in physics-based modeling and highlights areas for ongoing research.

42 ENGINEERING↗

Beta gallium oxide (β-Ga 2 O 3 ) nanoelectromechanical transducer for dual-modality solar-blind ultraviolet light detection

Empowered by an ultrawide bandgap ( E g = 4.5–4.9 eV), beta gallium oxide (β-Ga 2 O 3 ) crystal is an ideal material for solar-blind ultraviolet (SBUV, λ < 280 nm) detection. Here, we report on the first demonstration of dual-modality SBUV light sensing integrated in the same device enabled by multi-physics coupling across photo-electrical and photo-thermo-mechanical domains. The specially designed suspended β-Ga 2 O 3 nanoelectromechanical systems (NEMS) transducer reveals dual-modality responses, with a photocurrent responsivity of 4 mA/W and a frequency shift responsivity of 250 Hz/nW, upon SBUV light exposure. An additional demonstration of a β-Ga 2 O 3 photo-field-effect transistor exhibits a boosted responsivity of 63 A/W. Analysis on the device suggests that reducing the thickness and length of the transducer could further improve the SBUV light sensing responsivities for both modalities. The demonstration could pave the way for future realization of SBUV detectors with dual modalities for enhanced detection fidelity, or respectively optimized for different sensing scenarios.

36 MATERIALS SCIENCE↗

The effects of atmospheric turbulence on precision optical measurements used for antenna-pointing compensation

Blind pointing of the Deep Space Network (DSN) 70-meter antennas can be improved if distortions of the antenna structure caused by unpredictable environmental loads can be measured in real-time, and the resulting boresight shifts evaluated and incorporated into the pointing control loops. The measurement configuration of a proposed pointing compensation system includes an optical range sensor that measures distances to selected points on the antenna surface. The effect of atmospheric turbulence on the accuracy of optical distance measurements and a method to make in-situ determinations of turbulence-induced measurement errors are discussed.

Nerheim, N.↗

Imaging of Calibrated Defects in Additively Manufactured Materials: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. Currently, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. As a solution to NDE of AM, we are developing pulsed thermal imaging which is non-contact, one-sided, and scalable to arbitrary size and shape of the AM parts. Pulsed thermography (PT) system utilizes a high intensity flash lamp to rapidly heat surface of sample, and a high sensitivity fast-frame megapixel infrared (IR) camera to capture data of surface temperature variations. The acquired data cube consists of a stack of surface temperature images taken at different times. Information about material internal defects is extracted by analyzing the data cube. This report provides results of preliminary performance evaluation of pulsed thermal imaging capability in detection of imprinted flaws in AM metallic structures. The flaws were introduced into AM parts as imprinted hemispherical low density regions, consisting of trapped un-sintered metallic powder. Specimens for developed for this study consisted of AM stainless steel 316 and Inconel 718 plates. The diameters of imprinted defects varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. Pulsed thermal tomography (PTT) processes the measured data cube to obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. PTT has been previously used in imaging of similar size flat bottom hole (FBH) simulated defects in stainless steel 316 and Inconel 718 specimens. In the study involving AM specimens, PTT imaging results have shown that 1mm-diameter defects located 1mm and 2mm below the surface of specimens were detectable. Larger size defects were detectable at greater depth. We also explored an alternative approach to detection of material flaws in PT data cube, which is using neural learning-based approach to blind source separation. Detection of small material defects requires finding features in the data cube which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with phtotothermics, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

36 MATERIALS SCIENCE↗