Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Acute effects of bright light and caffeine on nighttime melatonin and temperature levels in women taking and not taking oral contraceptives

Caffeine and bright light effects on nighttime melatonin and temperature levels in women were tested during the luteal phase of the menstrual cycle (n=30) or the pseudo luteal phase for oral contraceptive users (n=32). Participants were randomly assigned to receive either bright (5000 lux) or dim room light (<88 lux) between 20:00 and 08:00 h under a modified constant routine protocol. Half the subjects in each lighting condition were administered either caffeine (100 mg) or placebo in a double-blind manner at 20:00, 23:00, 02:00 and 05:00 h. Results showed that the combination of bright light and caffeine enhanced nighttime temperature levels to a greater extent than did either caffeine or bright light alone. Both of the latter groups had higher temperature levels relative to the dim light placebo condition and the two groups did not differ. Temperature levels in the bright light caffeine condition were maintained at near peak circadian levels the entire night in the luteal and pseudo luteal phase. Melatonin levels were reduced throughout the duration of bright light exposure for all women. Caffeine reduced the onset of melatonin levels for women in the luteal phase, but it had little effect on melatonin levels for oral contraceptive users. The results for women in the luteal phase of the menstrual cycle are consistent with our previous findings in men. The results also suggest that oral contraceptives may alter the effects of caffeine on nighttime melatonin levels.

Clinical Trial↗

Abnormalities of the QT interval in primary disorders of autonomic failure

BACKGROUND: Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. SUBJECTS AND METHODS: Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. RESULTS: Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. CONCLUSIONS: Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.

Non-NASA Center↗

Assessment of a remote sensing-based model for predicting malaria transmission risk in villages of Chiapas, Mexico

A blind test of two remote sensing-based models for predicting adult populations of Anopheles albimanus in villages, an indicator of malaria transmission risk, was conducted in southern Chiapas, Mexico. One model was developed using a discriminant analysis approach, while the other was based on regression analysis. The models were developed in 1992 for an area around Tapachula, Chiapas, using Landsat Thematic Mapper (TM) satellite data and geographic information system functions. Using two remotely sensed landscape elements, the discriminant model was able to successfully distinguish between villages with high and low An. albimanus abundance with an overall accuracy of 90%. To test the predictive capability of the models, multitemporal TM data were used to generate a landscape map of the Huixtla area, northwest of Tapachula, where the models were used to predict risk for 40 villages. The resulting predictions were not disclosed until the end of the test. Independently, An. albimanus abundance data were collected in the 40 randomly selected villages for which the predictions had been made. These data were subsequently used to assess the models' accuracies. The discriminant model accurately predicted 79% of the high-abundance villages and 50% of the low-abundance villages, for an overall accuracy of 70%. The regression model correctly identified seven of the 10 villages with the highest mosquito abundance. This test demonstrated that remote sensing-based models generated for one area can be used successfully in another, comparable area.

Insect Vectors/growth & development↗

Predictions of malaria vector distribution in Belize based on multispectral satellite data

Use of multispectral satellite data to predict arthropod-borne disease trouble spots is dependent on clear understandings of environmental factors that determine the presence of disease vectors. A blind test of remote sensing-based predictions for the spatial distribution of a malaria vector, Anopheles pseudopunctipennis, was conducted as a follow-up to two years of studies on vector-environmental relationships in Belize. Four of eight sites that were predicted to be high probability locations for presence of An. pseudopunctipennis were positive and all low probability sites (0 of 12) were negative. The absence of An. pseudopunctipennis at four high probability locations probably reflects the low densities that seem to characterize field populations of this species, i.e., the population densities were below the threshold of our sampling effort. Another important malaria vector, An. darlingi, was also present at all high probability sites and absent at all low probability sites. Anopheles darlingi, like An. pseudopunctipennis, is a riverine species. Prior to these collections at ecologically defined locations, this species was last detected in Belize in 1946.

Non-NASA Center↗

Microneurographic evidence of sudden sympathetic withdrawal in carotid sinus syncope; treatment with ergotamine

A proportion of patients with carotid sinus syncope (CSS) remain symptomatic even after pacemaker implantation because of persistence of a vasodepressor component. We report a patient with CSS whose syncopal episodes could be reproduced by carotid sinus massage and were due to profound hypotension associated with sudden sympathetic withdrawal, based on direct measurements of sympathetic nerve traffic. A double-blind trial with inhaled ergotamine provided significant symptomatic relief.

Non-NASA Center↗

Human performance and physiological function during a 24-hr exposure to 1% bromotrifluoromethane (Halon 1301)

Performance and physiological measurements were obtained from four pairs of men exposed for 24 hr to 1% (10,000 ppm) Halon 1301 (bromotrifluoromethane, CBrF3) and to air with order counterbalanced using a double-blind protocol. Cognitive and motor performance was assessed before, during, and after the exposures using seven scales of the Automated Portable Testing System, which produced 13 measures of performance. Halon inhalation induced decrements in 2 of the 13 measures, but actual and estimated magnitudes of the decrements were no greater than 5% of baseline values. Physiological data were obtained before, during, and after the exposures from clinical chemistry analyses of blood and urine samples, pulmonary function tests, and monitoring of vital signs. Significant change during Halon inhalation was observed for 6 of the 52 variables assessed; however, all physiological values remained within clinically acceptable limits. No cardiovascular effects were noted. This study demonstrated that exposure to 1% Halon 1301 for 24 hr can produce minor disturbance of central nervous system function as assessed by cognitive tasks.

Randomized Controlled Trial↗

Aircraft Detection System Ensures Free-Space Laser Safety

As scientists continue to explore our solar system, there are increasing demands to return greater volumes of data from smaller deep-space probes. Accordingly, NASA is studying advanced strategies based on free-space laser transmissions, which offer secure, high-bandwidth communications using smaller subsystems of much lower power and mass than existing ones. These approaches, however, can pose a danger to pilots in the beam path because the lasers may illuminate aircraft and blind them. Researchers thus are investigating systems that will monitor the surrounding airspace for aircraft that could be affected. This paper presents current methods for safe free space laser propagation.

Smithgall, Brian↗

VEGF165 Stimulates Vessel Density and Vessel Diameter Differently in Angiogenesis and Lymphangiogenesis

Vascular endothelial growth factor-165 (VEGF(sub 165)) stimulated angiogenesis in the quail chorioallantoic membrane (CAM) by vessel expansion from the capillary network. However, lymphangiogenesis was stimulated by the filopodial guidance of tip cells located on blind-ended lymphatic sprouts. As quantified by fractal/generational branching analysis using the computer code VESGEN, vascular density increased maximally at low VEGF concentrations, and vascular diameter increased most at high VEGF concentrations. Increased vascular density and diameter were statistically independent events (r(sub s), -0.06). By fluorescence immunohistochemistry of VEGF receptors VEGFR-1 and VEGFR-2, alpha smooth muscle actin ((alpha) SMA) and a vascular/lymphatic marker, VEGF(sub 165) increased the density and diameter of sprouting lymphatic vessels guided by tip cells (accompanied by the dissociation of lymphatics from blood vessels). Isolated migratory cells expressing (alpha)SMA were recruited to blood vessels, whereas isolated cells expressing VEGFR-2 were recruited primarily to lymphatics. In conclusion, VEGF(sub 165) increased lymphatic vessel density by lymphatic sprouting, but increased blood vessel density by vascular expansion from the capillary network.

Parsons-Wingerter, Patricia↗

Fitting Flux Ropes to a Global MHD Solution: A Comparison of Techniques

Flux rope fitting (FRF) techniques are an invaluable tool for extracting information about the properties of a sub-class of coronal mass ejections (CMEs) in the solar wind. However, it has proven difficult to assess their accuracy since the underlying global structure of the CME cannot be independently determined from the data. In contrast, large-scale MHD simulations of CME evolution can provide both a global view as well as localized time series at specific points in space. In this study we apply five different fitting techniques to two hypothetical time series derived from MHD simulation results. Independent teams performed the analysis of the events in "blind tests", for which no information, other than time series, was provided. From the results, we infer the following: 1) Accuracy decreases markedly with increasingly glancing encounters; 2) Correct identification of the boundaries of the flux rope can be a significant limiter; 3) Results from techniques that infer global morphology must be viewed with caution. In spite of these limitations, FRF techniques remain a useful tool for describing in situ observations of flux rope CMEs.

Riley, Pete↗

Comparative Soot Diagnostics Experiment Looks at the Smoky World of Microgravity Combustion

From an economic standpoint, soot is one of the most important combustion intermediates and products. It is a major industrial product and is the dominant medium for radiant heat transport in most flames used to generate heat and power. The nonbuoyant structure of most flames of practical interest (turbulent flames) makes the understanding of soot processes in microgravity flames important to our ability to predict fire behavior on Earth. In addition, fires in spacecraft are considered a credible possibility. To respond to this risk, NASA has flown fire (or smoke) detectors on Skylab and the space shuttles and included them in the International Space Station design. The design of these detectors, however, was based entirely on normal gravity (1g) data. The detector used in the shuttle fleet is an ionization detector, whereas the system planned for the space station uses forward scattering of near-infrared light. The ionization detector, which is similar to smoke detectors used in homes, has a comparative advantage for submicron particulates. In fact, the space shuttle model uses a separation system that makes it blind to particles larger than a micron (believed to be dust). In the larger size range, the lightscattering detector is most sensitive. Without microgravity smoke data, the difference in the particle size sensitivities of the two detectors cannot be evaluated. As part of the Comparative Soot Diagnostics (CSD) experiment, these systems were tested to determine their response to particulates generated during long periods of low gravity. This experiment provided the first such measurements toward understanding soot processes on Earth and for designing and implementing improved spacecraft smoke detection systems. The objectives of CSD were to examine how particulates form from a variety of sources and to quantify the performance of several diagnostic techniques. The sources tested included four overheated materials (paper, silicone rubber, Teflon-coated (DuPont) wire, and Kapton-coated (DuPont) wires), each tested at three heating rates, and a candle tested at three air velocities. Paper, silicone rubber, and wire insulation, materials found in spacecraft crew cabins, were selected because of their different smoke properties. The candle yielded hydrocarbon soot typical of many 1g flames. Four diagnostic techniques were employed: thermophoretic sampling collected particulates for size analysis; laser light extinction measurements near the source tallied total particulate production; and laser light scattering and ionization detector measurements far from the particulate source provided data for evaluating the performance of smoke detection systems for these particulate sources.

Urban, David L.↗

Development of Ultra-High Sensivity Silicon Carbide Detectors

A variety of silicon carbide (SiC) detectors have been developed to study the sensitivity of SiC ultraviolet (UV) detectors, including Schottky photodiodes, p-i-n photodiodes, avalanche photodiodes (APDs), and single photon-counting APDs. Due to the very wide bandgap and thus extremely low leakage current, Sic photo-detectors showed excellent sensitivity. The specific detectivity, D*, of SiC photodiodes are orders of magnitude higher than that of their competitors, such as Si photodiodes, and comparable to the D* of photomultiplier tubes (PMTs). To pursue the ultimate detection sensitivity, SiC APDs and single photon-counting avalanche diodes (SPADs) have also been fabricated. By operating the SiC APDs at a linear mode gain over 10(exp 6), SPADs in UV have been demonstrated. SiC UV detectors have great potential for use in solar blind UV detection and biosensing. Moreover, SiC detectors have excellent radiation hardness and high temperature tolerance which makes them ideal for extreme environment applications such as in space or on the surface of the Moon or Mars.

Yan, Feng↗

Old Journey, New Heights

If you could see the road ahead, you might pass up a fantastic opportunity because you're blinded by the potential pitfalls. In my case, I was testing the project management waters at the NASA Dryden Flight Research Center after ten years of being a research engineer. I was an eager (but ignorant) rookie project manager (PM) and I was willing to engage in just about any project without knowing what it would entail. The assignment I accepted was to help NASA's Environment Research Aircraft and Sensor Technology (ERAST) Project, a partnership with a fledgling Uninhabited Aerial Vehicle (UAV) industry, to tackle stratospheric flight. I remember one of our industrial partners querying me about whether or not I understood what 1 was getting into. Like one of those bobble-head toys that have become quite popular, I nodded. But in reality, I didn't have a clue. His response was, "Hang on, it's going to be a wild ride." He was right. In retrospect, if I had clearly understood the ten years of pitfalls that were coming, I might not have "hung on." Now I can look back and say that I would not trade the experience for anything. The lows included the destruction of a number of UAVs on my watch. Later someone told me that we should not be surprised if we lost one UAV for every ten flights. We wrote many chapters in the book on what can go wrong with UAVs-and we are still writing. As you can imagine, each mishap was accompanied by an investigation. What an education!

DelFrate, John↗

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.↗

Dynamic Light-Scattering Probe Used for the Very Early Detection of Cataracts and to Measure Response to Therapy (or Treatment)

Half of all blindness worldwide is due to cataracts, and 34 million Americans over the age of 65 have cataracts. This figure is expected to rise to 70 million by the year 2030. Currently, no medical treatment is available to prevent or halt the progression of a cataract; nor is there any way to reverse a cataract once it has been detected by conventional methods. The only known treatment is surgical removal of the lens. It is estimated that over $5 billion will be spent this year for the treatment of cataract patients in the United States alone. According to Carl Kupfer, M.D., former Director of the National Eye Institute at the National Institutes of Health, "A delay in cataract formation of about 10 years would reduce the prevalence of visually disabling cataracts by about 45 percent." However, this vision remains a dream because of the lack of objective methods that can be used to detect cataracts very early and, hence, can be used for screening potential anticataract drugs. This is about to change. The National Eye Institute and NASA entered into a formal interagency agreement in late 1996 to develop and test a dynamic light-scattering (DLS) device to detect the earliest changes due to cataract formation. The new DLS probe developed by Dr. Ansari at the NASA Glenn Research Center is several orders of magnitude more sensitive than conventional clinical systems. This ultrahigh sensitivity enables the probe to detect the onset of a cataract before it has any effect on vision and allows researchers to test the effectiveness of anticataract drugs in reversing cataracts. This device (see the following illustration) was originally designed to study transport phenomena in microgravity fluid physics experiments onboard the space shuttle orbiters and space station. It will be very useful in testing anticataract drugs to halt or reverse the progression of cataracts during longitudinal clinical trials.

Ansari,Rafat R.↗

Calibration Experiments Conducted for Noninvasive Blood Glucose Sensing Through the Eye

There are more than 16 million diabetics in the United States and more than 100 million worldwide. Diabetes can lead to severe complications over time such as blindness, renal and cardiovascular diseases, and peripheral neuropathy in the limbs. Poor blood circulation in diabetics can lead to gangrene and the subsequent amputation of extremities. In addition, this pathology is the fourth leading cause of death in the United States. The most effective way to manage diabetes is frequent blood glucose monitoring performed by the patients themselves. However, because of pain, inconvenience, and the fear of developing infections from finger-prick blood tests or implants, many patients monitor their blood glucose levels less frequently than is recommended by their physicians. Therefore, a noninvasive, painless, and convenient method to monitor blood glucose would greatly benefit diabetics. Likewise, detecting, preventing, and treating the untoward effects of prolonged space travel (e.g., a human mission to Mars) in real-time requires the development of noninvasive diagnostic technologies that are compact and powerful. As a "window to the body," the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and to help develop preventative and therapeutic countermeasures early. The noninvasive feature of these technologies permits frequent repetition of tests, enabling an evaluation of the response to therapy.

Ansari, Rafat R.↗

By Different Cellular Mechanisms, Lymphatic Vessels Sprout by Endothelial Cell Recruitment Whereas Blood Vessels Grow by Vascular Expansion

The development of effective vascular therapies requires the understanding of all modes of vessel formation contributing to vasculogenesis, angiogenesis (here termed hemangiogenesis) and lymphangiogenesis. We show that lymphangiogenesis proceeds by blind-ended vessel sprouting via recruitment of isolated endothelial progenitor cells to the tips of growing vessels, whereas hemangiogenesis occurs by non-sprouting vessel expansion from the capillary network, during middevelopment in the quail chorioallantoic membrane (CAM). Blood vessels expanded out of capillaries that displayed transient expression of alpha smooth muscle actin (alphaSMA), accompanied by mural recruitment of migratory progenitor cells expressing SMA. Lymphatics and blood vessels were identified by confocal/fluorescence microscopy of vascular endothelial growth factor (VEGF) receptors VEGFR-1 and VEGFR-2, alphaSMA (expressed on CAM blood vessels but not on lymphatics), homeobox transcription factor Prox-1 (specific to CAM lymphatic endothelium), and the quail hematopoetic/vascular marker, QH-1. Expression of VEGFR-1 was highly restricted to blood vessels (primarily capillaries). VEGFR-2 was expressed intensely in isolated hematopoietic cells, lymphatic vessels and moderately in blood vessels. Prox-1 was absent from endothelial progenitor cells prior to lymphatic recruitment. Although vascular endothelial growth factor-165 (VEGF(sub 165)) is a key regulator of numerous cellular processes in hemangiogenesis and vasculogenesis, the role of VEGF(sub 165) in lymphangiogenesis is less clear. Exogenous VEGF(sub 165) increased blood vessel density without changing endogenous modes of vascular/lymphatic vessel formation or marker expression patterns. However, VEGF(sub 165) did increase the frequency of blood vascular anastomoses and strongly induced the antimaturational dissociation of lymphatics from blood vessels, with frequent formation of homogeneous lymphatic networks.

Parsons-Wingerter, Patricia↗

Application of Eddy Current Techniques for Orbiter Reinforced Carbon-Carbon Structural Health Monitoring

The development and application of advanced nondestructive evaluation techniques for the Reinforced Carbon-Carbon (RCC) components of the Space Shuttle Orbiter Leading Edge Structural Subsystem (LESS) was identified as a crucial step toward returning the shuttle fleet to service. In order to help meet this requirement, eddy current techniques have been developed for application to RCC components. Eddy current technology has been found to be particularly useful for measuring the protective coating thickness over the reinforced carbon-carbon and for the identification of near surface cracking and voids in the RCC matrix. Testing has been performed on as manufactured and flown RCC components with both actual and fabricated defects representing impact and oxidation damage. Encouraging initial results have led to the development of two separate eddy current systems for in-situ RCC inspections in the orbiter processing facility. Each of these systems has undergone blind validation testing on a full scale leading edge panel, and recently transitioned to Kennedy Space Center to be applied as a part of a comprehensive RCC inspection strategy to be performed in the orbiter processing facility after each shuttle flight.

Wincheski, Buzz↗

Bioavailability and Pharmacodynamics of Promethazine in Human Subjects

The acute effects of exposure to microgravity include the development of space motion sickness, which usually requires therapeutic intervention. The current drug of choice, promethazine (PMZ), is available to astronauts in three different dosage forms during space flight; its side effects include nausea, dizziness, sedation and impaired psychomotor performance. This ground-based study is designed to validate flight-suitable methods for pharmacodynamic evaluation of PMZ and to estimate bioavailability and pharmacodynamics of PMZ. Experimental design consists of intramuscular administration of three doses of PMZ (12.5,25 and 50 mg) and placebo in a randomized double blind fashion to human subjects and collecting blood, urine and saliva samples for 72 h. Subjects also complete cognitive performance test batteries, WinSCAT (Windows based Space Cognitive Assessment Test) and ARES (ANAM Readiness Evaluation System). Preliminary results indicate a significant relationship (p=9.88e-05) between circulating PMZ levels and cognitive performance parameters. Time to accurately complete memory tasks increases significantly with concentrations; higher concentrations also increase response time and decrease accuracy of substitution and matching tasks. AUC and half-life estimates for PMZ ranged between 0.12 and 1.7 mg.h/L and 15 and 50 h, respectively. These preliminary results indicate that PMZ may exhibit dose-dependent pharmacokinetics in humans; also, WinSCAT and ARES are sensitive for pharmacodynamic assessment of PMZ, and may be applicable for assessing the pharmacodynamics of other neurocognitive drugs.

Boyd, J. L.↗