Better measurement of multijunction solar cell efficiency
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Endangered Species Act requires actions that improve the passage and survival rates for migrating salmonoids and other fish species that sustain injury and mortality when passing through hydroelectric dams. To develop a low-cost revolutionary acoustic transmitter that may be injected instead of surgically implanted into the fish, one major challenge that needs to be addressed is the micro-battery power source. This work focuses on the design and fabrication of micro-batteries for injectable fish tags. High pulse current and required service life have both been achieved as well as doubling the gravimetric energy density of the battery. The newly designed micro-batteries have intrinsically low impedance, leading to significantly improved electrochemical performances at low temperatures as compared with commercial SR416 batteries. Successful field trial by using the micro-battery powered transmitters injected into fish has been demonstrated, providing an exemplary model of transferring fundamental research into practical devices with controlled qualities.
Purpose: To identify the most informative methods for reporting results of treatment planning comparisons. Methods: Seven articles from the past year of International Journal of Radiation Oncology Biology Physics reported on comparisons of treatment plans for IMRT and IMAT. The articles were reviewed to identify methods of comparisons. Decision theoretical concepts were used to evaluate the study methods and highlight those that provide the most information. Results: None of the studies examined the correlation between objectives. Statistical comparisons provided some information but not enough to provide support for a robust decision analysis. Conclusions: The increased use of treatment planning studies to evaluate different methods in radiation therapy requires improved standards for designing the studies and reporting the results.
Purpose: The purpose of this work was to clarify the interactions between the parameters used in the {gamma} index with the surface-based distance method, which itself can be viewed as a generalized version of the {gamma} index. The examined parameters included the distance to agreement (DTA)/dose difference (DD) criteria, the percentage used as a passing criterion, and the passing percentage for given DTA/DD criteria. The specific aims of our work were (1) to understand the relationships between the parameters used in the {gamma} index, (2) to determine the detection limit, or the minimum detectable error, of the {gamma} index with a given set of parameters, and (3) to establish a procedure to determine parameters that are consistent with the capacity of an IMRT QA system. Methods: The surface-based distance technique with dose gradient factor was derived, and then the relationship between surface-based distance and {gamma} index was established. The dose gradient factor for plans and measurements of 10 IMRT patients, 10 spine stereotactic radiosurgery (SRS) patients, and 3 Radiological Physics Center (RPC) head and neck phantom were calculated and evaluated. The detection limits of the surface-based distance and {gamma} index methods were examined by introducing known shifts to the 10 IMRT plans. Results: The means of the dose gradient factors were 0.434 mm/% and 0.956 mm/% for the SRS and IMRT plans, respectively. Key quantities (including the mean and 90th and 99th percentiles of the distance distribution) of the surface-based distance distribution between two dose distributions were linearly proportional to the actual shifts. However, the passing percentage of the {gamma} index for a given set of DTA/DD criteria was not associated with the actual shift. For IMRT, using the standard quality assurance criteria of 3 mm/3% DTA/DD and a 90% passing rate, we found that the detection limit of the {gamma} index in terms of global shift was 4.07 mm/4.07 % without noise. Conclusions: Surface-based distance is a direct measure of the difference between two dose distributions and can be used to evaluate or determine parameters for use in calculating the {gamma} index. The dose gradient factor represents the weighting between spatial and dose shift and should be determined before DTA/DD criteria are set. The authors also present a procedure to determine {gamma} index parameters from measurements.
No abstract prepared.
Purpose: In standard proton therapy clinical practice, proton stopping power uncertainties are in the order of 3.5%, which affects the ability of placing the proton Bragg peak at the edge of the tumor. The innovating idea of this project is to approach the uncertainty problem in RSP by using combined information from X-ray CT and proton radiography along a few beam angles. In addition, this project aims to quantify the systematic error introduced by the theoretical models (Janni, ICRU49, Bischel) for proton stopping power in media. Methods: A 3D phantom of 36 cm3 composed of 9 materials randomly placed is created. Measured RSP values are obtained using a Gammex phantom with a proton beam. Theoretical RSP values are calculated with Beth-Block equation in combination with three databases (Janni, ICRU49 and Bischel). Clinical RSP errors are simulated by introducing a systematic (1.5%, 2.5%, 3.5%) and a random error (+/−0.5%) to the theoretical RSP. A ray-tracing algorithm uses each of these RSP tables to calculate energy loss for proton crossing the phantom through various directions. For each direction, gradient descent (GD) method is done on the clinical RSP table to minimize the residual energy difference between the simulation with clinical RSP and with theoretical RSP. The possibility of a systematic material dependent error is investigated by comparing measured RSP to theoretical RSP as calculated from the three models. Results: Using 10,000 iterations on GD algorithm, RSP differences between theoretical values and clinical RSP have converged (<1%) for each error introduced. Results produced with ICRU49 have the smallest average difference (0.021%) to the measured RSP. Janni (1.168%) and Bischel (−0.372%) database shows larger systematic errors. Conclusion: Based on these results, ray-tracing optimisation using information from proton radiography and X-ray CT demonstrates a potential to improve the proton range accuracy in a clinical environment.
Purpose: To reduce uncertainties in relative stopping power (RSP) estimates for ions (alpha and carbon) by using Ion radiographic-imaging and X-ray CT prior-knowledge. Methods: A 36×36 phantom matrix composed of 9 materials with different thicknesses and randomly placed is generated. Theoretical RSPs are calculated using stopping power (SP) data from three references (Janni, ICRU49 and Bischel). We introduced an artificial systematic error (1.5%, 2.5% or 3.5%) and a random error (<0.5%) to the SP to simulated patient ion-range errors present in clinic environment. Carbon/alpha final energy for each RSPs set (theoretical and from CT images) is obtained with a ray-tracing algorithm. A gradient descent (GD) method is used to minimize the difference in exit particle energy, between theory and X-ray CT RSP maps, by iteratively correcting the RSP map from X-ray CT. Once a new set of RSPs is obtained for a direction a new optimization is done over other direction using the RSPs from the previous optimization. Theoretical RSPs are compared with experimental RSPs obtained with Gammex Phantom. Results: Preliminary results show that optimized RSP values can be obtained with smaller uncertainties (<1%) than clinical RSPs (1.5% to 3.5%). Theoretical values from three different references show uncertainties, up to 3% from experimental values. Further investigation will consider prior-knowledge from RSP obtained with CT images and ion radiographies from Monte Carlo Simulations. Conclusion: GD and ray-tracing methods have been implemented to reduce RSP uncertainties from values obtained for clinical treatment. Experimental RSPs will be obtained using carbon/alpha beams to consider the existence of material dependent systematic errors. Based on the results, it is hoped to show that using ray-tracing optimization with ion radiography and prior knowledge on RPSs, treatment planning accuracy and cost-effectiveness can be improved.
Purpose: HNC IMRT treatment planning is a challenging process that relies heavily on the planner’s experience. Previously, we used the single, best match from a library of manually planned cases to semi-automatically generate IMRT plans for a new patient. The current multi-case Knowledge Based Radiation Therapy (MC-KBRT) study utilized different matching cases for each of six individual organs-at-risk (OARs), then combined those six cases to create the new treatment plan. Methods: From a database of 103 patient plans created by experienced planners, MC-KBRT plans were created for 40 (17 unilateral and 23 bilateral) HNC “query” patients. For each case, 2D beam’s-eye-view images were used to find similar geometric “match” patients separately for each of 6 OARs. Dose distributions for each OAR from the 6 matching cases were combined and then warped to suit the query case’s geometry. The dose-volume constraints were used to create the new query treatment plan without the need for human decision-making throughout the IMRT optimization. The optimized MC-KBRT plans were compared against the clinically approved plans and Version 1 (original KBRT) using the dose metrics: mean, median, and maximum (brainstem and cord+5mm) doses. Results: Compared to Version 1, MC-KBRT had no significant reduction of the dose to any of the OARs in either unilateral/bilateral cases. Compared to the manually-planned unilateral cases, there was significant reduction of the oral cavity mean/median dose (>2Gy) at the expense of the contralateral parotid. Compared to the manually-planned bilateral cases, reduction of dose was significant in the ipsilateral parotid, larynx, and oral cavity (>3Gy mean/median) while maintaining PTV coverage. Conclusion: MC-KBRT planning in head and neck cancer generates IMRT plans with equivalent dose sparing to manually created plans. MC-KBRT using multiple case matches does not show significant dose reduction compared to using a single match case with dose warping.
Purpose: To quantitatively compare patient internal target volume (ITV)-based plans with retrospectively generated gated plans to evaluate potential dosimetric improvements in lung toxicity from gated radiotherapy. Methods: Evaluation was conducted for 150 stereotactic body radiation therapy (SBRT) treatment plans for 128 early-stage (T1–T3, <5cm) NSCLC patients. PTV margins were: ITV+5 mm (ITV-plan) and GTV+5 mm (Gated-plan). ITV-based and gated treatment plans were compared on the same free-breathing CT. ITV-based plan constraints were used to re-optimize and recalculate new gated plans. Plans were generated for 3 fractionation regimens: 3×18Gy, 4×12Gy (original), and 5×10Gy. Physical dose was converted to equivalent dose in 2Gy fractions (EQD2), which was used to determine mean lung dose (MLD) and percent volume of lung receiving ≥20Gy (V20). MLD and V20 differences between gating and ITV-based plans were analyzed as a function of both three-dimensional (3D) motion and tumor volume. The low dose region, V5, was also evaluated. Results: MLD and V20 differences between gated and ITV-based plans were larger for lower (1.48±1.32Gy and 1.44±1.29%) than for upper lobe tumors (0.89±0.74Gy and 0.92±0.71%) due to smaller tumor motion (2.9±3.4mm) compared to lower lobe tumors (8.1±6.1mm). Average differences of <1–2% were noted in V5 between ITV and gated plans. Dosimetric differences between gating and ITV-based methods increased with increasing tumor motion and decreasing tumor volume. Overall, average MLD (8.04±3.92Gy) and V20 (8.29±4.33%) values for ITV-based plans were already well below clinical guidelines, even for the 3×18Gy dose scheme, for which largest differences were noted relative to gated plans. Similar results were obtained for 5×10Gy and 4×12Gy regimens. Conclusion: Clinically relevant improvement in pulmonary toxicity, based on predictors of radiation pneumonitis (MLD and V20) was not generally observed, though improvement for tumors with 3D motion >15 mm, mainly concentrated in peripheral lower lobe tumors, may be considered clinically relevant. Work supported in part by a grant from Varian Medical systems, Palo Alto, CA.
Purpose: To standardize the tube calibration for Elekta XVI cone beam CT (CBCT) systems in order to provide a meaningful estimate of the daily imaging dose and reduce the variation between units in a large centre with multiple treatment units. Methods: Initial measurements of the output from the CBCT systems were made using a Farmer chamber and standard CTDI phantom. The correlation between the measured CTDI and the tube current was confirmed using an Unfors Xi detector which was then used to perform a tube current calibration on each unit. Results: Initial measurements showed measured tube current variations of up to 25% between units for scans with the same image settings. In order to reasonably estimate the imaging dose, a systematic approach to x-ray generator calibration was adopted to ensure that the imaging dose was consistent across all units at the centre and was adopted as part of the routine quality assurance program. Subsequent measurements show that the variation in measured dose across nine units is on the order of 5%. Conclusion: Increasingly, patients receiving radiation therapy have extended life expectancies and therefore the cumulative dose from daily imaging should not be ignored. In theory, an estimate of imaging dose can be made from the imaging parameters. However, measurements have shown that there are large differences in the x-ray generator calibration as installed at the clinic. Current protocols recommend routine checks of dose to ensure constancy. The present study suggests that in addition to constancy checks on a single machine, a tube current calibration should be performed on every unit to ensure agreement across multiple machines. This is crucial at a large centre with multiple units in order to provide physicians with a meaningful estimate of the daily imaging dose.
Purpose: To propose a simple and effective cost value function to search optimal planning phase (gating window) and demonstrated its feasibility for respiratory correlated radiation therapy. Methods: We acquired 4DCT of 10 phases for 10 lung patients who have tumor located near OARs such as esophagus, heart, and spinal cord (i.e., central lung cancer patients). A simplified mathematical optimization function was established by using overlap volume histogram (OVH) between the target and organ at risk (OAR) at each phase and the tolerance dose of selected OARs to achieve surrounding OARs dose-sparing. For all patients and all phases, delineation of the target volume and selected OARs (esophagus, heart, and spinal cord) was performed (by one observer to avoid inter-observer variation), then cost values were calculated for all phases. After the breathing phases were ranked according to cost value function, the relationship between score and dose distribution at highest and lowest cost value phases were evaluated by comparing the mean/max dose. Results: A simplified mathematical cost value function showed noticeable difference from phase to phase, implying it is possible to find optimal phases for gating window. The lowest cost value which may result in lower mean/max dose to OARs was distributed at various phases for all patients. The mean doses of the OARs significantly decreased about 10% with statistical significance for all 3 OARs at the phase with the lowest cost value. Also, the max doses of the OARs were decreased about 2∼5% at the phase with the lowest cost value compared to the phase with the highest cost value. Conclusion: It is demonstrated that optimal phases (in dose distribution perspective) for gating window could exist differently through each patient and the proposed cost value function can be a useful tool for determining such phases without performing dose optimization calculations. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)
Energy storage has mainly focused on electrochemical systems (1). However, more than 90% of the world's primary energy generation is consumed or wasted thermally. Thermal energy storage has a broad and critical role to play in making energy use more sustainable for heating and cooling, solar energy harvesting, and other applications. Thermal storage technologies are still based on solutions developed decades ago, such as molten salt, ice, and paraffin phase-change systems, whose performance and cost do not merit widerscale adoption. Progress in materials science, chemistry, and engineering may lead to dramatic breakthroughs in thermal energy storage that could improve the efficiency with which we produce, distribute, and consume energy.
A common strategy aimed at achieving a high temporal resolution in ultrafast electron microscopy and diffraction is based on the use of strong electrostatic fields in the accelerating gap to form fast electron pulses of ultrashort duration. In this work, the dynamics of the propagation of ultrashort photoelectron bunches is studied taking into account the time-of-flight chromatic aberration: the spread-out of electron pulses at the exit from the region of the accelerating electric field. The results of the calculation of the duration of photoelectron pulses taking into account Coulomb repulsion are presented. According to the analysis, the use of strong electrostatic fields in the accelerating gap for the formation of fast electron pulses of ultrashort duration is not a necessary condition for achieving the final high temporal resolution in the method of ultrafast electron microscopy. The modes of operation of ultrafast transmission electron microscope were found for which the temporal resolution increases with the growth of time-of-flight chromatic aberration.
BUHFS is a fuse-based POSIX compliant filesystem interface for HPSS. BUHFS was written to provide users with a stable, POSIX compliant interface to EMSL new HPSS based Scientific Data Archive, Aurora.
This is an open-source, empirical data-driven, virtual building energy analysis and retrofit targeting tool. The open-source tool will provide a fully-automated, "no-cost/no-touch" approach to screen large volumes of buildings for operational improvement and equipment upgrade opportunities and quantify associated potential energy and cost savings.
Representation of cloud microphysics is a key aspect of simulating clouds. From the early days of cloud modeling, numerical models have relied on an Eulerian approach for all cloud and thermodynamic and microphysics variables. Over time the sophistication of microphysics schemes has steadily increased, from simple representations of bulk masses of cloud and rain in each grid cell, to including different ice particle types and bulk hydrometeor concentrations, to complex schemes referred to as bin or spectral schemes that explicitly evolve the hydrometeor size distributions within each model grid cell. As computational resources grow, there is a clear trend toward wider use of bin schemes, including their use as benchmarks to develop and test simplified bulk schemes. We argue that continuing on this path brings fundamental challenges difficult to overcome. The Lagrangian particle-based probabilistic approach is a practical alternative in which the myriad of cloud and precipitation particles present in a natural cloud is represented by a judiciously selected ensemble of point particles called superdroplets or superparticles. Here, the advantages of the Lagrangian particle-based approach when compared to the Eulerian bin methodology are explained, and the prospects of applying the method to more comprehensive cloud simulations—for instance, targeting deep convection or frontal cloud systems—are discussed.
A key to good processor utilization for sparse matrix computations is storing the data in the format that is most conducive to fast access by the memory system. In particular, for sparse matrix triangular solves the traditional compressed sparse matrix format is poor, and minor adjustments to the data structure can increase the processor utilization dramatically. Such adjustments involve storing the L and U factors separately and storing the U rows 'backwards' so that they are accessed in a simple streaming fashion during the triangular solves. Changes to the PETSc libraries to use this modified storage format resulted in over twice the floating-point rate for some matrices. This improvement can be accounted for by a decrease in the cache misses and TLB (transaction lookaside buffer) misses in the modified code.