Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “below- threshold ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Multi-chord fiber-coupled interferometry of supersonic plasma jets andcomparisons with synthetic data

A multi-chord fiber-coupled interferometer [Merritt et al., Rev. Sci. Instrum. 83, 033506 (2012)] is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment [Hsu et al., Bull. Amer. Phys. Soc. 56, 307 (2011)]. The long coherence length of the laser (> 10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which an initially positive phase shift becomes negative when the ionization fraction drops below a certain threshold. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx} 15-50 km/s), jet length ({approx} 20-100 cm), and 3D expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

60 APPLIED LIFE SCIENCES↗

A versatile electron-ion coincidence spectrometer for photoelectron momentum imaging and threshold spectroscopy on mass selected ions using synchrotron radiation

We present a photoelectron-photoion coincidence (PEPICO) spectrometer named DELICIOUS II which combines a velocity map imaging apparatus with a Wiley-McLaren time of flight analyzer for the study of gas phase samples in interaction with the synchrotron radiation (SR). This versatile system is capable of providing photoelectron images on mass-selected compounds with kinetic energy resolutions of {delta}E/E=5% and a 17 eV bandwidth, as well as threshold photoelectron spectra with a measured resolution of 0.8 meV, as demonstrated on the 3p{sup -1} ionization of argon. This instrument is also employed for threshold PEPICO experiments, allowing the selection of the parent ion's internal state with sub-meV resolution for light masses (<40 amu) and with typically 2 meV resolution for a mass of 100 amu and with a mass resolving power above 200. The continuous operation of the extraction fields and the independence from the electron's time of flight are well adapted to the quasicontinuous multibunch mode of the SR. This, together with the high transmission of both the electron and ion detection, allows a high coincidence counting rate and facilitates the subtraction of false coincidences. We illustrate the spectrometer's coincidence principle of operation with examples from the valence photoionization of an Ar+Xe mixture and of CF{sub 4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of self-focusing on tunnel-ionization-induced injection in a laser wakefield accelerator

We report on the study of the self-focusing effects on the tunnel-ionization-induced injection in a laser wakefield accelerator. Targets composed of a gas mixture of 94% helium and 6% oxygen were used. The energy, energy spread, and charge of the generated electron beams can be adjusted by changing the input laser intensity and the plasma density, but the different aspects of the properties of the electron beams were not independent. It was inferred that the K-shell electrons of oxygen were ionized and injected into the plasma wake for acceleration when the laser intensity was increased beyond the threshold for generating O{sup 7+} by tunnel-ionization, due to the relativistic self-focusing in the propagation. Controlling the self-focusing of the laser beam by adjusting the input laser energy to shorten the distance over which the electrons were injected into the wake, quasi-monoenergetic electron beams were observed.

43 PARTICLE ACCELERATORS↗

Relaxation channels of multi-photon excited xenon clusters

The relaxation processes of the xenon clusters subjected to multi-photon excitation by laser radiation with quantum energies significantly lower than the thresholds of excitation of atoms and ionization of clusters were studied. Results obtained by means of the photoelectron spectroscopy method showed that desorption processes of excited atoms play a significant role in the decay of two-photon excited xenon clusters. A number of excited states of xenon atoms formed during this process were discovered and identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionization of cytosine monomer and dimer studied by VUV photoionization and electronic structure calculations

We report a combined theoretical and experimental study of ionization of cytosine monomers and dimers. Gas-phase molecules are generated by thermal vaporization of cytosine followed by expansion of the vapor in a continuous supersonic jet seeded in Ar. The resulting species are investigated by single photon ionization with tunable vacuum-ultraviolet (VUV) synchrotron radiation and mass analyzed using reflectron mass spectrometry. Energy onsets for the measured photoionization efficiency (PIE) spectra are 8.60+-0.05 eV and 7.6+-0.1 eV for the monomer and the dimer, respectively, and provide an estimate for the adiabatic ionization energies (AIE). The first AIE and the ten lowest vertical ionization energies (VIEs) for selected isomers of cytosine dimer computed using equation-of-motion coupled-cluster (EOM-IP-CCSD) method are reported. The comparison of the computed VIEs with the derivative of the PIE spectra, suggests that multiple isomers of the cytosine dimer are present in the molecular beam. The calculations reveal that the large red shift (0.7 eV) of the first IE of the lowest-energy cytosine dimer is due to strong inter-fragment electrostatic interactions, i.e., the hole localized on one of the fragments is stabilized by the dipole moment of the other. A sharp rise in the CH+ signal at 9.20+-0.05 eV is ascribed to the formation of protonated cytosine by dissociation of the ionized dimers. The dominant role of this channel is supported by the computed energy thresholds for the CH+ appearance and the barrierless or nearly barrierless ionization-induced proton transfer observed for five isomers of the dimer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effects of Threshold Voltage and Number of Fins per Transistor on the TID Response of GF 12LP Technology

This abstract presents a comprehensive analysis of total ionizing dose (TID) response in GlobalFoundries’ 12LP 12nm bulk FinFET technology using 10keV X-rays. Devices with higher threshold voltages (VTs) demonstrated lower increases in off-state leakage current (IDS,OFF) post-irradiation, highlighting the mitigating role of high VT in TID response. Our data shows that transistors with fewer fins exhibit superior TID resistance, implying lower susceptibility to radiation effects. Our study also probed two bias conditions, "Gate-On" and "Pass-Gate," with the former displaying more severe TID degradation. Interestingly, p-type devices displayed negligible degradation, underscoring their inherent resilience to TID effects. Additionally, medium thick n-type devices echoed the fin-count-dependent TID response observed in other transistor types, further strengthening our findings. These results underscore the importance of strategic transistor selection and design for enhancing the TID resilience of future CMOS FinFET architectures, particularly critical in radiation-intense environments.

42 ENGINEERING↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrashort-pulse laser ablation of nanocrystalline aluminum

Molecular-dynamics simulations of the ablation of nanocrystalline Al films by ultrashort laser pulses in the low-fluence (no-ionization) regime (0-2.5 times the ablation threshold, F{sub th}) are reported. The simulations employ an embedded-atom method potential for the dynamics of the ions and a realistic two-temperature model for the electron gas (and its interactions with the ion gas), which confers different electronic properties to the monocrystalline solid, nanocrystalline solid, and liquid regions of the targets. The ablation dynamics in three nanocrystalline structures is studied: two dense targets with different crystallite sizes (d=3.1 and 6.2 nm on average) and a d=6.2 nm porous sample. The results are compared to the ablation of monocrystalline Al. Significant differences are observed, the nanocrystalline targets showing, in particular, a lower ablation threshold and a larger melting depth, and yielding pressure waves of higher amplitude than the monocrystalline targets. Furthermore, it is shown that nanocrystalline targets experience no residual stress associated with thermal expansion and lateral constraints, and that little crystal growth occurs in the solid during and after ablation. Laser-induced spallation of the back surface of the films is also investigated; we find, in particular, that the high-strain fracture resistance of nanocrystalline samples is significantly reduced in comparison to the crystalline material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-photon ionization and fragmentation of uracil: Neutral excited-state ring opening and hydration effects

Multi-photon ionization (MPI) of the RNA base uracil has been studied in the wavelength range 220–270 nm, coinciding with excitation to the S{sub 2}(ππ*) state. A fragment ion at m/z = 84 was produced by 2-photon absorption at wavelengths ≤232 nm and assigned to C{sub 3}H{sub 4}N{sub 2}O{sup +} following CO abstraction. This ion has not been observed in alternative dissociative ionization processes (notably electron impact) and its threshold is close to recent calculations of the minimum activation energy for a ring opening conical intersection to a σ(n-π)π* closed shell state. Moreover, the predicted ring opening transition leaves a CO group at one end of the isomer, apparently vulnerable to abstraction. An MPI mass spectrum of uracil-water clusters is presented for the first time and compared with an equivalent dry measurement. Hydration enhances certain fragment ion pathways (particularly C{sub 3}H{sub 3}NO{sup +}) but represses C{sub 3}H{sub 4}N{sub 2}O{sup +} production. This indicates that hydrogen bonding to water stabilizes uracil with respect to neutral excited-state ring opening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiments to Further the Understanding of the Triple-Alpha Process in Hot Astrophysical Scenarios

In astrophysics, the first excited 0{sup +} state of {sup 12}C at 7.654 MeV (Hoyle state) is the most important in the triple-{alpha} process for carbon nucleosynthesis. In explosive scenarios like supernovae, where temperatures of several 10{sup 9} K are achieved, the interference of the Hoyle state with the second 0{sup +} state located at 10.3 MeV in {sup 12}C becomes significant. The recent NACRE compilation of astrophysical reaction rates assumes a 2{sup +} resonance at 9.1 MeV for which no experimental evidence exists. Thus, it is critical to explore in more detail the 7-10 MeV excitation energy region, especially the minimum between the two 0{sup +} resonances for carbon nucleosynthesis. The states in {sup 12}C were populated through the {beta}-decay of {sup 12}B and {sup 12}N produced at the ATLAS (Argonne Tandem Linac Accelerator System) in-flight facility. The decay of {sup 12}C into three alphas is detected in a Frisch grid twin ionization chamber, acting as a low-threshold calorimeter. This minimizes the effects of {beta}-summing and allowed us to investigate the minimum above the Hoyle state with much higher accuracy than previously possible. A detailed data analysis will include an R-matrix fit to determine an upper limit on the 2{sup +} resonance width.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results on low-mass weakly interacting massive particles from an 11 kg d target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

WIMP search, Dark Matter, DAMIC, SNOLAB↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface

Evolution of rapid ({approx}10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 10{sup 14}-10{sup 20} cm{sup -3} and T{sub e} = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm{sup 2}; above this value, heating becomes explosive (namely, an increase in the temperature growth rate ({delta}{sup 2}T/{delta}t{sup 2} > 0) and in passing current ({delta}J/{delta}t > 0) is observed in the final stage at T {approx} 10{sup 4} K and j {approx} 10{sup 8} A/cm{sup 2}). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm{sup -3} because the current is limited by the space charge of electrons, rapid overheating of top of microprotrusion is observed much sooner (over a time period of {approx}1 ns) when the threshold is exceeded. In this case, intense ionization of vapor of the wall material leads to an increase in the plasma density at the surface, and the heating becomes of the Ohmic explosion type. Such conditions for the formation of a micrixplosion on the surface and of an ecton accompanying it can be created during the interaction of a plasma with the cathode, anode, or an insulated wall and may lead to the formation of cathode and anode spots, as well as unipolar arcs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Atmospheric Pressure and Composition on LIBS

Most LIBS experiments are conducted at standard atmospheric pressure in air. However, there are LIBS studies that vary the pressure and composition of the gas. These studies have provided insights into fundamentals of the mechanisms that lead to the emission and methods for improving the quality of LIBS spectra. These atmospheric studies are difficult because the effects of pressure and gas composition and interconnected, making interpretation of the results difficult. The influence of pressures below and above 760 Torr have been explored. Performing LIBS on a surface at reduced pressures (<760 Torr) can result in enhanced spectra due to higher resolution, increased intensity, improved signal-to-noise (S/N), and increased ablation. Lower pressures produce increased resolution because the line width in LIBS spectra is predominantly due to Stark and Doppler broadening. Stark broadening is primarily caused from collisions between electrons and atoms, while Doppler broadening is proportional to the plasma temperature. Close examination using a high resolution spectrometer reveals that spectra show significant peak broadening and self-absorption as pressures increase, especially for pressures >760 Torr. During LIBS plasma expansion, energy is lost to the surrounding atmosphere, which reduces the lifetime of the laser plasma. Therefore, reducing the pressure increases the lifetime of the plasma, allowing more light from the laser plasma to be collected; thus, increasing the observed signal intensity. However, if pressures are too low (<10 Torr), then there is a steep drop in LIBS spectral intensity. This loss in intensity is mostly due to a disordered plasma that results from the lack of sufficient atmosphere to provide adequate confinement. At reduced pressures, the plasma expands into a less dense atmosphere, which results in a less dense shock wave. The reduced density in the shock wave results in reduced plasma shielding, allowing more photons to reach the sample. Increasing the number of photons interacting with the sample surface results in increased ablation, which can lead to increased intensity. The composition of the background gas has been shown to greatly influence the observed LIBS spectra by altering the plasma temperature, electron density, mass removal, and plasma shielding that impact the emission intensity and peak resolution. It has been reported that atmospheric Ar results in the highest plasma temperature and electron density, while a He atmosphere results in the lowest plasma temperatures and electron density. Studying temporal data, it was also found that Ar had the slowest decay of both electron density and plasma temperature, while He had the fastest decay in both parameters. The higher plasma temperature and electron density results in an increase in line broadenin, or poor resolution, for Ar compared to He. A rapidly developing LIBS plasma with a sufficient amount of electrons can absorb a significant portion of the laser pulse through inverse Bremsstahlung. Ar (15.8 eV ) is more easily ionized than He (24.4 eV). The breakdown threshold for He at 760 Torr is approximately 3 times greater than Ar and approximately 5 times greater at 100 Torr. The lower breakdown threshold in Ar, compared to He, creates an environment favorable for plasma shielding, which reduces sample vaporization and leads to a weaker LIBS signal.

36 MATERIALS SCIENCE↗

Results on low-mass weakly interacting massive particles from a 11 kg-day target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the K-shell ionization cross sections of Si by 3-25-keV electron impact using the thick-target method

In this paper, the K-shell ionization cross sections of Si element in the threshold energy region of 3-25 keV have been measured by using the thick-target method. With the Monte Carlo simulations, the effects of multiple scattering of incident electrons and from the bremsstrahlung photons and other secondary particles in the thick-target method have been discussed. The detection efficiency calibration in the lower-energy region has been performed by using the bremsstrahlung spectra of thick carbon target by electron impact in combination with the use of standard x-ray sources, and the detector thickness parameters have also been determined by a nonlinear least-squares fit. The ill-posed inverse problem involved in the thick-target method has been dealt with by the Tikhonov regularization method. The experimental K-shell ionization cross sections for Si element obtained in this paper have also been compared with some theoretical models, and it has been observed that the experimental data in this paper are in good agreement with the theoretical values based on the distorted-wave Born approximation model developed most recently.

74 ATOMIC AND MOLECULAR PHYSICS↗

Impact of 12-nm FinFET Technology Variations on TID Effects: A Comparative Study of GF 12LP and 12LP+ at the Transistor Level

Here, this article presents a comparative analysis of total ionizing dose (TID) response in GlobalFoundries’ (GF) 12 low-power (LP) and 12LP+12-nm bulk fin field effect transistor (FinFET) technologies using 10-keV X-rays. Our findings show that 12LP+ n-type transistors demonstrate higher sensitivity to TID degradation of the off-state leakage drain current compared to 12LP. Data indicate that for both 12LP and 12LP+, transistors with higher threshold voltages (VTs) exhibit lower off-state drain-source leakage postirradiation compared to transistors with lower VTs. Data consistently show that transistors with fewer fins per transistor show superior TID tolerance, in both 12LP and 12LP+ technologies. Lower VT transistors in both technologies display similar preirradiation leakage currents. On the other hand, higher VT transistors in 12LP+ show lower preirradiation leakage currents than those in 12LP, highlighting that the front-end-of-line of 12LP+ technology has been modified compared to 12LP. p-type devices in 12LP+ presented negligible degradation. Larger TID sensitivity in 12LP+ might be attributed to the implementation of dual-metal gate work functions, reduced halo doping, deeper source/drain (S/D) doping profiles, and/or 12LP+ having narrower fins compared to 12LP.

Dual-metal gate work functions↗