Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Initial Commissioning Experience With the LCLS Injector

The Linac Coherent Light Source (LCLS) is a SASE xray Free-Electron Laser (FEL) project presently under construction at SLAC [1]. The injector section, from drive-laser and RF photocathode gun through first bunch compressor chicane, was installed in fall 2006. Initial system commissioning with an electron beam is taking place during the spring and summer of 2007. The second phase of construction, including second bunch compressor and full linac, will begin later, in the fall of 2007. We report here on experience gained during the first phase of machine commissioning, including RF photocathode gun, linac booster section, S-band and X-band RF systems, first bunch compressor, and the various beam diagnostics.

43 PARTICLE ACCELERATORS↗

Commissioning of soft and deep X-ray lithography beamline on Indus-2

Soft and Deep x-ray lithography (SDXRL) beamline is commissioned on Indus-2. The beamline can be operated between 1.5 to 20 keV and in white beam mode. Beamline consists of two x-ray mirrors, slits, Be-windows, beam diagnostics and filters assemblies and radiation safety systems. A custom built X-ray scanner is used to create 3-D high aspect ratio micro structures. The paper reports the commissioning results of this beamline.

43 PARTICLE ACCELERATORS↗

Space-time resolved measurements of spontaneous magnetic fields in laser-produced plasma

The first space-time resolved spontaneous magnetic field (SMF) measurements realized on Prague Asterix Laser System are presented. The SMF was generated as a result of single laser beam (1.315 μm) interaction with massive planar targets made of materials with various atomic numbers (plastic and Cu). Measured SMF confirmed azimuthal geometry and their maximum amplitude reached the value of 10 MG at the laser energy of 250 J for both target materials. It was demonstrated that spatial distributions of these fields are associated with the character of the ablative plasma expansion which clearly depends on the target material. To measure the SMF, the Faraday effect was employed causing rotation of the vector of polarization of the linearly polarized diagnostic beam. The rotation angle was determined together with the phase shift using a novel design of a two-channel polaro-interferometer. To obtain sufficiently high temporal resolution, the polaro-interferometer was irradiated by Ti:Sa laser pulse with the wavelength of 808 nm and the pulse duration of 40 fs. The results of measurements were compared with theoretical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser

This is the final report for the DoE BES contract DE-FG02-07ER46272. This grant began under a title that gives its history in a few words: The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser. At the time of adopting this name, the UCLA Particle Beam Physics Laboratory (PBPL) was at the forefront of the first demonstrations of SASE FEL, giving the experimental basis for the 4th generation X-ray light source now exemplified by the LCLS, a remarkable generation of machines that have revolutionize nanoscale and ultrafast science. The grant title indicates that physical aspects of the FEL are of interest, and implies that progress requires comprehensive investigations. These aspects include: the physics and technology of high brightness electron beam generation, phase space manipulations, advanced beam diagnostics, state-of-the-art undulators, studies of FEL mode characteristics, as well as the introduction of new theoretical models and start-to-end simulations, all yielding a deep understanding of the SASE FEL. The latest period (2010-13) of BES grant support has been the most productive yet for the UCLA PBPL, and the extensive list of accomplishments is illustrative of our central contributions to advanced FEL research. We give a concise overview here and review our research results in further detail below. In FEL and ultrafast beam physics, we have experimentally investigated: production of helical beams and FEL modes with orbital angular momentum; chirp-taper single-spike FEL gain; new FROG techniques optimized for FEL, introduced coherent imaging of beam profiles using transition radiation; and demonstrated a next generation cryoundulator. We have performed deep theoretical studies of these phenomena and other advanced FEL physics concepts, such as the space-charge amplifier. In high brightness beams, we have: introduced a new class of hybrid photoinjector for <100 fs beam production; developed new approaches to self-shaped ellipsoidal beams; used nonlinear plasma oscillations to create beam pulse trains; tested new plasmonic, high quantum efficiency cathodes, and developed new methods of beam measurement with um spatial/sub-fs temporal resolution. In ultrafast imaging, we have: developed advanced electro-optic timing systems, performed the 1st pump-probe study using single shot UED, demonstrated continuously time-resolved UED with RF deflection; made initial use of inverse Compton scattering (ICS) X-ray sources in application through single-shot inline phase contrast imaging, established single-shot X-ray diffraction, and observed ICS high harmonic generation and redshifting due to nonlinear effects. In 5th generation light source research, we have developed the techniques of narrowband, very high power coherent Cerenkov radiation sources based on dielectric wakefield devices. This work is represented by numerous publications in leading journals: e.g. Nature Physics, Physical Review Letters, Applied Physics Letters. The PBPL program’s influence on the field also extends to organization of the electron beam applications community; we have organized the first international UED workshops and the initial two meetings dedicated to 5th generation light source.

43 PARTICLE ACCELERATORS↗

Beam Compression in Heavy-Ion Induction Linacs

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using space-charge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has been demonstrated in the LBNL Neutralized Drift Compression Experiment (NDCX) experiment with controlled ramps and forced neutralization. The achieved peak beam current and energy can be used in experiments to heat targets and create warm dense matter. Using an injected 30 mA K{sup +} ion beam with initial kinetic energy 0.3 MeV, axial compression leading to {approx}50x current amplification and simultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss experiments that are under development to reach the necessary higher beam intensities and the associated beam diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Advances and New Techniques in Visualization of Ultra-short Relativistic Electron Bunches

Ultrashort electron bunches with rms length of {approx} 1 femtosecond (fs) can be used to generate ultrashort x-ray pulses in FELs that may open up many new regimes in ultrafast sciences. It is also envisioned that ultrashort electron bunches may excite {approx}TeV/m wake fields for plasma wake field acceleration and high field physics studies. Recent success of using 20 pC electron beam to drive an x-ray FEL at LCLS has stimulated world-wide interests in using low charge beam (1 {approx} 20 pC) to generate ultrashort x-ray pulses (0.1 fs {approx} 10 fs) in FELs. Accurate measurement of the length (preferably the temporal profile) of the ultrashort electron bunch is essential for understanding the physics associated with the bunch compression and transportation. However, the shorter and shorter electron bunch greatly challenges the present beam diagnostic methods. In this paper we review the recent advances in the measurement of ultra-short electron bunches. We will focus on several techniques and their variants that provide the state-of-the-art temporal resolution. Methods to further improve the resolution of these techniques and the promise to break the 1 fs time barrier is discussed. We review recent advances in the measurement of ultrashort relativistic electron bunches. We will focus on several techniques and their variants that are capable of breaking the femtosecond time barrier in measurements of ultrashort bunches. Techniques for measuring beam longitudinal phase space as well as the x-ray pulse shape in an x-ray FEL are also discussed.

43 PARTICLE ACCELERATORS↗

Infrared imaging diagnostics for intense pulsed electron beam

Infrared imaging diagnostic method for two-dimensional calorimetric diagnostics has been developed for intense pulsed electron beam (IPEB). By using a 100-μm-thick tungsten film as the infrared heat sink for IPEB, the emitting uniformity of the electron source can be analyzed to evaluate the efficiency and stability of the diode system. Two-dimensional axisymmetric finite element method heat transfer simulation, combined with Monte Carlo calculation, was performed for error estimation and optimization of the method. The test of the method was finished with IPEB generated by explosive emission electron diode with pulse duration (FWHM) of 80 ns, electron energy up to 450 keV, and a total beam current of over 1 kA. The results showed that it is possible to measure the cross-sectional energy density distribution of IPEB with energy sensitivity of 0.1 J/cm{sup 2} and spatial resolution of 1 mm. The technical details, such as irradiation protection of bremsstrahlung γ photons and the functional extensibility of the method were discussed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Beam-Beam Counter: A Local Polarimeter at STAR

At the Brookhaven National Laboratory (BNL) Relativistic Heavy Ion Collider (RHIC) the Beam-Beam Counter (BBC) array for the Solenodial Tracker at RHIC (STAR) is a very versatile tool for polarized proton beam diagnostics. The BBC setup provides an excellent minimum bias trigger; and for hits on the inner annuli of six hexagonal scintillator tiles the BBC coincidence trigger with a suitable algorithm has a quite large single spin analyzing power {approx}8x10{sup -3} for 100 GeV polarized proton -100 GeV polarized proton collisions. The STAR BBC is a very effective local polarimeter at these energies. For 100 GeV p-vector -100 GeV p-vector running in 2006 the BBC measured single spin asymmetries to a statistical accuracy of better than 2% for a data run of 20-30 minutes; and these measurements were quite robust. For fills with a duration of at least six hours these STAR BBC asymmetry measurements were used to study the time dependence of the polarization for 100 GeV proton beams in the RHIC rings. The decrease of the polarization is quite small, <0.01P{sub B} per hour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CSR Fields: Direct Numerical Solution of the Maxwell___s Equation

We discuss the properties of the coherent electromagnetic fields of a very short, ultra-relativistic bunch in a rectangular vacuum chamber inside a bending magnet. The analysis is based on the results of a direct numerical solution of Maxwell's equations together with Newton's equations. We use a new dispersion-free time-domain algorithm which employs a more efficient use of finite element mesh techniques and hence produces self-consistent and stable solutions for very short bunches. We investigate the fine structure of the CSR fields including coherent edge radiation. This approach should be useful in the study of existing and future concepts of particle accelerators and ultrafast coherent light sources. The coherent synchrotron radiation (CSR) fields have a strong action on the beam dynamics of very short bunches, which are moving in the bends of all kinds of magnetic elements. They are responsible for additional energy loss and energy spread; micro bunching and beam emittance growth. These fields may bound the efficiency of damping rings, electron-positron colliders and ultrafast coherent light sources, where high peak currents and very short bunches are envisioned. This is relevant to most high-brightness beam applications. On the other hand these fields together with transition radiation fields can be used for beam diagnostics or even as a powerful resource of THz radiation. A history of the study of CSR and a good collection of references can be found in [1]. Electromagnetic theory suggests several methods on how to calculate CSR fields. The most popular method is to use Lienard-Wiechert potentials. Other approach is to solve numerically the approximate equations, which are a Schrodinger type equation. These numerical methods are described in [2]. We suggest that a direct solution of Maxwell's equations together with Newton's equations can describe the detailed structure of the CSR fields [3].

43 PARTICLE ACCELERATORS↗

A 10 nN resolution thrust-stand for micro-propulsion devices

We report on the development of a nano-Newton thrust-stand that can measure up to 100 μN thrust from different types of microthrusters with 10 nN resolution. The compact thrust-stand measures the impingement force of the particles emitted from a microthruster onto a suspended plate of size 45 mm × 45 mm and with a natural frequency over 50 Hz. Using a homodyne (lock-in) readout provides strong immunity to facility vibrations, which historically has been a major challenge for nano-Newton thrust-stands. A cold-gas thruster generating up to 50 μN thrust in air was first used to validate the thrust-stand. Better than 10 nN resolution and a minimum detectable thrust of 10 nN were achieved. Thrust from a miniature electrospray propulsion system generating up to 3 μN of thrust was measured with our thrust-stand in vacuum, and the thrust was compared with that computed from beam diagnostics, obtaining agreement within 50 nN to 150 nN. The 10 nN resolution obtained from this thrust-stand matches that from state-of-the-art nano-Newton thrust-stands, which measure thrust directly from the thruster by mounting it on a moving arm (but whose natural frequency is well below 1 Hz). The thrust-stand is the first of its kind to demonstrate less than 3 μN resolution by measuring the impingement force, making it capable of measuring thrust from different types of microthrusters, with the potential of easy upscaling for thrust measurement at much higher levels, simply by replacing the force sensor with other force sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High power RF conditioning of 2856 MHz, 40 keV prototype buncher cavity system

An on axis biperiodic buncher cavity system at 2856 MHz with three bunching cells plus one power feed cell has been designed and fabricated for 40 keV pulsed electron beam injection from a thermionic gun. The vacuum and high power RF conditioning prior to the beam injection is presented in this paper. Initially the cavity system along with the in-flange fast current transformer and the beam diagnostics chamber has been baked at 60-65 °C for 22 hours under a vacuum ≤ 6 x 10{sup -6} mbar. The final ultimate vacuum was 2.3 x 10{sup -6} mbar and it took 195 seconds to reach to 1 x 10{sup -5} mbar with the gate valve closed. After this the high power RF conditioning was done from 0.3 MW to 1.2 MW input RF power with 4μsec. pulse at 1 Hz PRF. At this point the ultimate vacuum reached to 2.3 x 10{sup -6} mbar and reached to 1 x 10{sup -5} mbar in 195 seconds after closing the gate valve. Finally the system was conditioned with 1MW, 4μsec. RF pulses at 20 Hz PRF. (author)

43 PARTICLE ACCELERATORS↗

A Test Stand for Ion Sources of Ultimate Reliability

The rationale behind the ITUR project is to perform a comparison between different kinds of H{sup -} ion sources using the same beam diagnostics setup. In particular, a direct comparison will be made in terms of the emittance characteristics of Penning Type sources such as those currently in use in the injector for the ISIS (UK) Pulsed Neutron Source and those of volumetric type such as that driving the injector for the ORNL Spallation Neutron Source (TN, U.S.A.). The endeavour here pursued is thus to build an Ion Source Test Stand where virtually any type of source can be tested and its features measured and, thus compared to the results of other sources under the same gauge. It would be possible then to establish a common ground for effectively comparing different ion sources. The long term objectives are thus to contribute towards building compact sources of minimum emittance, maximum performance, high reliability-availability, high percentage of desired particle production, stability and high brightness. The project consortium is lead by Tekniker-IK4 research centre and partners are companies Elytt Energy and Jema Group. The technical viability is guaranteed by the collaboration between the project consortium and several scientific institutions, such the CSIC (Spain), the University of the Basque Country (Spain), ISIS (STFC-UK), SNS (ORNL-USA) and CEA in Saclay (France)

43 PARTICLE ACCELERATORS↗

Fueling Studies on the Lithium Tokamak Experiment

Lithium plasma facing components reduce the flux of "recycled" particles en- tering the plasma edge from the plasma facing components. This results in increased external fueling requirements and provides the opportunity to control the magnitude and distribution of the incoming particle flux. It has been pre- dicted that the plasma density profile will then be determined by the deposition profile of the external fueling, rather than dominated by the recycled particle flux. A series of experiments on the Lithium Tokamak Experiment demonstrate that lithium wall coatings facilitate control of the neutral and plasma particle in- ventories. With fresh lithium coatings and careful gas injection programming, over 90% of the injected particle inventory can be absorbed in the lithium wall during a discharge. Furthermore, dramatic changes in the fueling requirements and plasma parameters were observed when lithium coatings were applied. This is largely due to the elimination of water as an impurity on the plasma facing components. A Molecular Cluster Injector (MCI) was developed for the fueling of LTX plas- mas. The MCI uses a supersonic nozzle, cooled to liquid nitrogen temperatures, to create the conditions necessary for molecular cluster formation. It has been predicted that molecular clusters will penetrate deeper into plasmas than gas- phase molecules via a reduced ionization cross-section and by improving the collimation of the neutral jet. Using an electron beam diagnostic, the densities of the cryogenic MCI are measured to be an order of magnitude higher than in the room-temperature jets formed with the same valve pressure. This indi- cates increased collimation relative to what would be expected from ideal gas dynamics alone. A systematic study of the fueling efficiencies achieved with the LTX fueling systems is presented. The fueling efficiency of the Supersonic Gas Injector (SGI) is demonstrated to be strongly dependent on the distance between the nozzle and plasma edge. The fueling efficiency of the gas puffer was improved by the addition of a guide tube to keep the gas flow collimated and directed towards the plasma edge. Contrary to results reported on other devices, the MCI yields fueling efficiencies that are at best equal to the SGI. This suggests that any enhanced penetration from cluster formation is nullified by the reduced velocity of the cryogenic gas. Furthermore, at very high neutral fluxes, the fueling efficiency of the MCI dropped off dramatically, suggesting that the build-up of pressure in the scrape-off-layer is producing a self-shielding effect. All of these results are consistent with the idea that the best gas-based fueling source is one that brings highly directed neutrals to the plasma edge, without being scattered or ionized in the scrape-off-layer. The density profiles of LTX plasmas are measured during external fueling with the gas puffer, SGI, and cryogenic MCI. While the density profile amplitude increases with higher fueling rates, the shape of the profile remains constant. This suggests that particle transport is such that differences in the neutral deposition cannot be discerned. The density profiles are consistently hollow, suggesting a region of reduced particle transport in the core of LTX plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results of the plasma wakefield acceleration experiment at PITZ

The self-modulation instability of long particle beams was proposed as a new mechanism to produce driver beams for proton driven plasma wakefield acceleration (PWFA). The PWFA experiment at the Photo Injector Test facility at DESY, Zeuthen site (PITZ) was launched to experimentally demonstrate and study the self-modulation of long electron beams in plasma. Key aspects for the experiment are the very flexible photocathode laser system, a plasma cell and well-developed beam diagnostics. In this contribution we report about the plasma cell design, preparatory experiments and the results of the first PWFA experiment at PITZ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An adaptive approach to machine learning for compact particle accelerators

Abstract Machine learning (ML) tools are able to learn relationships between the inputs and outputs of large complex systems directly from data. However, for time-varying systems, the predictive capabilities of ML tools degrade if the systems are no longer accurately represented by the data with which the ML models were trained. For complex systems, re-training is only possible if the changes are slow relative to the rate at which large numbers of new input-output training data can be non-invasively recorded. In this work, we present an approach to deep learning for time-varying systems that does not require re-training, but uses instead an adaptive feedback in the architecture of deep convolutional neural networks (CNN). The feedback is based only on available system output measurements and is applied in the encoded low-dimensional dense layers of the encoder-decoder CNNs. First, we develop an inverse model of a complex accelerator system to map output beam measurements to input beam distributions, while both the accelerator components and the unknown input beam distribution vary rapidly with time. We then demonstrate our method on experimental measurements of the input and output beam distributions of the HiRES ultra-fast electron diffraction (UED) beam line at Lawrence Berkeley National Laboratory, and showcase its ability for automatic tracking of the time varying photocathode quantum efficiency map. Our method can be successfully used to aid both physics and ML-based surrogate online models to provide non-invasive beam diagnostics.

97 MATHEMATICS AND COMPUTING↗

Spontaneous L-mode plasma rotation scaling in the TCV tokamak

Predicting intrinsic plasma rotation and its shear, which often help stabilize plasma instabilities affecting plasma performance, is important for prospective fusion grade devices. Although rotation in ITER-like scenarios has been extrapolated from measured experimental plasma rotation data, little is understood about the underlying mechanisms governing either the generation or dissipation of momentum in a tokamak plasma. This paper reports on studies of intrinsic toroidal and poloidal plasma rotation from charge exchange spectroscopy using a low power diagnostic beam on the TCV tokamak [Tonetti et al., in Proceedings of the Symposium on Fusion Technology (1991), p. 587] that drives negligible toroidal velocity. In TCV, plasma behavior can be separated by the core and edge regions. In limited configurations, the core rotates in the counter-current direction and can reverse to the co-current direction with a <10% increase in the plasma density. This is different for diverted configurations where the core rotates in the co-current direction reversing to the counter-current direction at higher plasma densities. For all these situations, core toroidal momentum is strongly transported by plasma sawteeth oscillations. In contrast, the toroidal edge rotation is close to stationary for limited discharges but evolves with plasma density for diverted configurations. Theoretical models that predict a change in momentum transport from turbulence have previously been suggested to provide a mechanism that might explain these phenomena. In this paper, mode activity that changes at the toroidal velocity reversal, is identified as a new possible candidate. In the absence of an available model that can explain these basic phenomena, this paper presents observations and, where possible, scaling of the rotation profiles with some of the major plasma parameters such as current, density and shape to guide the development of a physics model for use in improving the extrapolation of the rotation amplitude and profiles to future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metamaterials for Cherenkov Radiation Based Particle Detectors

Measurement of Cherenkov radiation (CR) has long been a useful technique for charged particle detection and beam diagnostics. We are investigating metamaterials engineered to have refractive indices tailored to enhance properties of CR that are useful for particle detectors and that cannot be obtained using conventional media. Cherenkov radiation in dispersive media with a large refractive index differs significantly from the same effect in conventional detector media, like gases or aerogel. The radiation pattern of CR in dispersive metamaterials presents lobes at very large angles with respect to particle motion. Moreover, the frequency and particle velocity dependence of the radiated energy can differ significantly from CR in a conventional dielectric medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of x-ray vortex dipoles using a single diffraction pattern and direct phase measurement using interferometry

We have devised a method for generating x-ray vortices by using a diffraction pattern from a simple aperture with illumination wave fronts with spherical curvatures. The interferometry visualized the x-ray vortex dipoles by the direct phase measurement. Our interference technique enabled us to sensitively detect and quantitatively measure various phase dislocations on the x-ray wave fronts, providing useful methodologies for beam diagnostics and materials science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗