Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Automatic Tuning Matching Cycler (ATMC) in situ NMR spectroscopy as a novel approach for real-time investigations of Li- and Na-ion batteries

We have developed and explored the use of a new Automatic Tuning Matching Cycler (ATMC) in situ NMR probe system to track the formation of intermediate phases and investigate electrolyte decomposition during electrochemical cycling of Li- and Na-ion batteries (LIBs and NIBs). The new approach addresses many of the issues arising during in situ NMR, e.g., significantly different shifts of the multi-component samples, changing sample conditions (such as the magnetic susceptibility and conductivity) during cycling, signal broadening due to paramagnetism as well as interferences between the NMR and external cycler circuit that might impair the experiments. We provide practical insight into how to conduct ATMC in situ NMR experiments and discuss applications of the methodology to LiFePO4 (LFP) and Na3V2(PO4)2F3 cathodes as well as Na metal anodes. Automatic frequency sweep 7Li in situ NMR reveals significant changes of the strongly paramagnetic broadened LFP line shape in agreement with the structural changes due to delithiation. Additionally, 31P in situ NMR shows a full separation of the electrolyte and cathode NMR signals and is a key feature for a deeper understanding of the processes occurring during charge/discharge on the local atomic scale of NMR. 31P in situ NMR with “on-the-fly” re-calibrated, varying carrier frequencies on Na3V2(PO4)2F3 as a cathode in a NIB enabled the detection of different P signals within a huge frequency range of 4000 ppm. The experiments show a significant shift and changes in the number as well as intensities of 31P signals during desodiation/sodiation of the cathode. The in situ experiments reveal changes of local P environments that in part have not been seen in ex situ NMR investigations. Furthermore, we applied ATMC 23Na in situ NMR on symmetrical Na–Na cells during galvanostatic plating. An automatic adjustment of the NMR carrier frequency during the in situ experiment ensured on-resonance conditions for the Na metal and electrolyte peak, respectively. Thus, interleaved measurements with different optimal NMR set-ups for the metal and electrolyte, respectively, became possible. This allowed the formation of different Na metal species as well as a quantification of electrolyte consumption during the electrochemical experiment to be monitored. The new approach is likely to benefit a further understanding of Na-ion battery chemistries.

25 ENERGY STORAGE↗

A Climate-Data Record (CDR) of the "Clear Sky" Surface Temperature of the Greenland Ice Sheet

To quantify the ice-surface temperature (IST) we are developing a climate-data record (CDR) of monthly IST of the Greenland ice sheet, from 1982 to the present using Advanced Very High Resolution Radiometer (AVHRR) and Moderate-Resolution Imaging Spectroradiometer (MODIS) data at 5-km resolution. "Clear-sky" surface temperature increases have been measured from the early 1980s to the early 2000s in the Arctic using AVHRR data, showing increases ranging from 0.57-0.02 (Wang and Key, 2005) to 0.72 0.10 deg C per decade (Comiso, 2006). Arctic warming has implications for ice-sheet mass balance because much of the periphery of the ice sheet is near 0 deg C in the melt season and is thus vulnerable to more extensive melting (Hanna et al., 2008). The algorithm used for this work has a long history of measuring IST in the Arctic with AVHRR (Key and Haefliger, 1992). The data are currently available from 1981 to 2004 in the AVHRR Polar Pathfinder (APP) dataset (Fowler et al., 2000). J. Key1NOAA modified the AVHRR algorithm for use with MODIS (Hall et al., 2004). The MODIS algorithm is now being processed over Greenland. Issues being addressed in the production of the CDR are: time-series bias caused by cloud cover, and cross-calibration between AVHRR and MODIS instruments. Because of uncertainties, time series of satellite ISTs do not necessarily correspond with actual surface temperatures. The CDR will be validated by comparing results with in-situ (see Koenig and Hall, in press) and automatic-weather station data (e.g., Shuman et al., 2001).

Hall, Dorothy K.↗

Fast Beam-Based BPM Calibration

The Alignment Diagnostic System (ADS) of the LCLS undulator system indicates that the 33 undulator quadrupoles have extremely high position stability over many weeks. However, beam trajectory straightness and lasing efficiency degrade more quickly than this. A lengthy Beam Based Alignment (BBA) procedure must be executed every two to four weeks to re-optimize the X-ray beam parameters. The undulator system includes RF cavity Beam Position Monitors (RFBPMs), several of which are utilized by an automatic feedback system to align the incoming electron-beam trajectory to the undulator axis. The beam trajectory straightness degradation has been traced to electronic drifts of the gain and offset of the BPMs used in the beam feedback system. To quickly recover the trajectory straightness, we have developed a fast beam-based procedure to recalibrate the BPMs. This procedure takes advantage of the high-precision monitoring capability of the ADS, which allows highly repeatable positioning of undulator quadrupoles. This report describes the ADS, the position stability of the LCLS undulator quadrupoles, and some results of the new recovery procedure.

43 PARTICLE ACCELERATORS↗

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

XRF-XFS-XAS-Auto v1.0 - Beta release

This software allows to analyze XRF maps, XFS spectra and XAS spectra collected at the Advanced Light Source's Beamline 10.3.2. Features include: 1) XRF maps: - process XRF maps, all elemental maps are saved as bmp automatically and labeled with the incident energy used, the scale bar is also labeled and can be controlled. - XRF elemental correlation plots, save the correlation plots automatically - Extract single or multiple transects in XRF maps on one or several regions of interest, each transect profile is numbered and saved in a corresponding folder, along with the corresponding maps showing transect location. 2) XFS spectra - save in log10 scale the XFS spectra, either a single or multiple files all at once. The files are saved as .bmp. - XFS spectra are labeled according to tabulated fluorescence emission lines. 3) XAS spectra - allows to plot individual scalers in the raw data. - allows calibration of the spectra using an Io internal glitch present in all spectra and performing 1st derivative. - Least-square linear combination fitting of XANES or extended XANES spectra using a database of standards using 1, 2 or 3 components maximum. It also provides the 5 top combinations and provide the user for the possibility of saving the 2nd, 3rd, 4th and 5th best combinations in addition to the best one. The processed spectra (pre-edge background substracted, post-edge normalized), the fits and residuals are automatically saved. A table of the component, with fit% and SSN is provided and saved automatically as well.

Fakra, Sirine↗

Fitness Tracker for Weight Lifting Style Workouts

This document proposes an early, high level design for a fitness tracking system which can automatically log weight lifting style workouts. The system will provide an easy to use interface both physically through the use of several wireless wristband style motion trackers worn on the limbs, and graphically through a smartphone application. Exercise classification will be accomplished by calibration of the user’s specific motions. The system will accurately track a user’s workout, miscounting no more than one repetition in every 20, have sufficient battery life to last several hours, work with existing smartphones and have a cost similar to those of current fitness tracking devices. This document presents the mission background, current state-of-theart, stakeholders and their expectations, the proposed system’s context and concepts, implementation concepts, system requirements, first sublevel function decomposition, possible risks for the system, and a reflection on the design process.

42 ENGINEERING↗

ATS-5 trilateration support

The development of an L-band trilateration network capable of locating the ATS-5 satellite, determining the satellite's orbital elements, and predicting the satellite position was investigated. An automatic tone-code ranging transponder was used to compare ranging measurements and communications reliability for the VHF and L-band. The L-band transponder network, analytical techniques, and the determination of the Kepler orbit parameters are described along with the calibration procedures, operation procedures, and verification of trilateration position.

Brisken, A. F.↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Recent developments at JPL in the application of image processing to astronomy

Four applications of image processing to astronomy, automated location and analysis of star and galaxy images, geometric and radiometric decalibration of vidicon spectra, display of multiband radio images, and generation of high resolution polarization direction and magnitude maps from images are presented with illustrative examples. The technique by which a digital image can be analyzed automatically to locate and segregate between stars and galaxies and the steps performed by the classifier to determine the nature of each object are outlined. The classification program executed on a 48 inch Schmidt plate of the cluster of galaxies 655 is described. The calibration and decalibration steps to remove geometric and radiometric distortions from a silicon vidicon camera digital spectra are discussed. Three methods of displaying multispectral radio data, generating a mosaic of each image, producing a color coded image to depict radio velocity, and producing a stereo pair with radial velocity as depth are described. The generation of polarization information from images obtained through linear polarizing filters is illustrated, and it is concluded that in each case information was displayed using digital techniques which could not readily have been provided visually.

Lorre, J. J.↗

Hexavalent chromium sensor for real-time In situ measurement of ground water contamination - 15433

Hexavalent chromium (Cr{sup 6+}) is a contaminant of concern at multiple Department of Energy (DOE) and industrial sites across the United States. It is used in stainless steel production, textile dyes, tanning, wood preservation, and in conversion coatings. It was used at DOE sites, such as the Hanford Nuclear Reservation in Washington state, in the form sodium dichromate (Na{sub 2}Cr{sub 2}O{sub 7}) to inhibit corrosion. This has resulted in the release of chromate (CrO{sub 4}{sup 2-}) to groundwater. Chromate is anionic and is readily transported with ground water through the subsurface to receptors such as river biota at Hanford, and in some regions to potable water wells. To improve Cr{sup 6+} groundwater plume monitoring while reducing monitoring cost, a cable-deployed, submersible sensor was developed for direct measurements of Cr{sup 6+} in natural groundwater. With a diameter of 3.8 cm (1.5 inch) the sensor could be deployed in 5 cm (2 inch) diameter screened wells. The sensor uses ultra violet (UV) photo-spectroscopy to measure Cr{sup 6+} at concentrations as low as 5 to 10 μg L{sup -1} (as hexavalent chromium, Cr{sup +6}) in natural water. Turbidity, caused by colloidal material suspended in natural water, can interfere with the chromate measurement but was automatically compensated within the instrument. Because the instrument had some temperature sensitivity, a correction was also applied based on in situ temperature measurements in the sensor. The sensor has been tested in the laboratory and was deployed to the field with encouraging results. Laboratory calibrations consistently yielded concentration measurements that correlate well with standard analytical methods (r{sup 2} = 0.99). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Climate-Data Record (CDR) of the Surface Temperature of the Greenland Ice Sheet

Regional "clear sky" surface temperature increases since the early 1980s in the Arctic, measured using Advanced Very High Resolution Radiometer (AVHRR) infrared data, range from 0.57+/-0.02 deg C to 72+/-0.10 deg C per decade. Arctic warming has important implications for ice-sheet mass balance because much of the periphery of the Greenland Ice Sheet is already near 0 deg C during the melt season, and is thus vulnerable to rapid melting if temperatures continue to increase. An increase in melting of the ice sheet would accelerate sea-level rise, an issue affecting potentially billions of people worldwide. To quantify the ice-surface temperature (IST) of the Greenland Ice Sheet, and to provide an IST dataset of Greenland for modelers that provides uncertainties, we are developing a climate-data record (CDR) of daily "clear-sky" IST of the Greenland Ice Sheet, from 1982 to the present using AVHRR (1982 - present) and Moderate-Resolution Imaging Spectroradiometer (MODIS) data (2000 - present) at a resolution of approximately 5 km. Known issues being addressed in the production of the CDR are: time-series bias caused by cloud cover (surface temperatures can be different under clouds vs. clear areas) and cross-calibration in the overlap period between AVHRR instruments, and between AVHRR and MODIS instruments. Because of uncertainties, mainly due to clouds, time-series of satellite IST do not necessarily correspond with actual surface temperatures. The CDR will be validated by comparing results with automatic-weather station data and with satellite-derived surface-temperature products and biases will be calculated.

Hall, Dorthy K.↗

MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine

Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart review.

60 APPLIED LIFE SCIENCES↗

Eye tracking and gating system for proton therapy of orbital tumors

Purpose: A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. Methods: We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. Results: Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. Conclusions: The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors.

60 APPLIED LIFE SCIENCES↗

Weather satellite picture receiving stations, APT digital scan converter

The automatic picture transmission digital scan converter is used at ground stations to convert signals received from scanning radiometers to data compatible with ground equipment designed to receive signals from vidicons aboard operational meteorological satellites. Information necessary to understand the circuit theory, functional operation, general construction and calibration of the converter is provided. Brief and detailed descriptions of each of the individual circuits are included, accompanied by a schematic diagram contained at the end of each circuit description. Listings of integral parts and testing equipment required as well as an overall wiring diagram are included. This unit will enable the user to readily accept and process weather photographs from the operational meteorological satellites.

Vermillion, C. H.↗

Reinforcement learning based automated history matching for improved hydrocarbon production forecast

History matching aims to find a numerical reservoir model that can be used to predict the reservoir performance. An engineer and model calibration (data inversion) method are required to adjust various parameters/properties of the numerical model in order to match the reservoir production history. In this study, we develop deep neural networks within the reinforcement learning framework to achieve automated history matching that will reduce engineers’ efforts, human bias, automatically and intelligently explore the parameter space, and remove the need of large set of labeled training data. To that end, a fast-marching-based reservoir simulator is encapsulated as an environment for the proposed reinforcement learning. The deep neural-network-based learning agent interacts with the reservoir simulator within reinforcement learning framework to achieve the automated history matching. Reinforcement learning techniques, such as discrete Deep Q Network and continuous Deep Deterministic Policy Gradients, are used toth, used to train the learning agents. The continuous actions enable the Deep Deterministic Policy Gradients to explore more states at each iteration in a a learning episode; consequently, a better history matching is achieved using this algorithm as compared to Deep Q Network. For simplified dual-target composite reservoir models, the best history-matching performances of the discrete and continuous learning methods in terms of normalized root mean square errors are 0.0447 and 0.0038, respectively. Furthermore, our study shows that continuous action space achieved by the deep deterministic policy gradient drastically outperforms deep Q network.

42 ENGINEERING↗

Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers

To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a “beacon transmitter” which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.

47 OTHER INSTRUMENTATION↗

NORSAR Final Scientific Report Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Correlation detection is a relatively new approach in seismology that offers significant advantages in increased sensitivity and event screening over standard energy detection algorithms. The basic concept is that a representative event waveform is used as a template (i.e. matched filter) that is correlated against a continuous, possibly multichannel, data stream to detect new occurrences of that same signal. These algorithms are therefore effective at detecting repeating events, such as explosions and aftershocks at a specific location. This final report summarizes the results of a three-year cooperative project undertaken by NORSAR and Lawrence Livermore National Laboratory. The overall objective has been to develop and test a new advanced, automatic approach to seismic detection using waveform correlation. The principal goal is to develop an adaptive processing algorithm. By this we mean that the detector is initiated using a basic set of reference ('master') events to be used in the correlation process, and then an automatic algorithm is applied successively to provide improved performance by extending the set of master events selectively and strategically. These additional master events are generated by an independent, conventional detection system. A periodic analyst review will then be applied to verify the performance and, if necessary, adjust and consolidate the master event set. A primary focus of this project has been the application of waveform correlation techniques to seismic arrays. The basic procedure is to perform correlation on the individual channels, and then stack the correlation traces using zero-delay beam forming. Array methods such as frequency-wavenumber analysis can be applied to this set of correlation traces to help guarantee the validity of detections and lower the detection threshold. In principle, the deployment of correlation detectors against seismically active regions could involve very large numbers of very specific detectors. To meet this challenge, we have examined two strategies: (1) use of subspace detectors, a multi-dimensional extension of correlators, which allow representation and detection of signals exhibiting some degree of variation; and (2) autonomous calibration of many subspace and correlation detectors in an adaptive detection framework, subject to analyst review. Because correlation detectors are relatively new to seismology, a significant amount of research on how to tune these detectors has been needed to address later calibration efforts that will arise as they are adopted for operational use. We have approached these challenges by carrying out a number of case studies, encompassing various monitoring scenarios such as earthquake aftershock sequences and swarms, recurring mining explosions, other types of explosions, and rockbursts. We have studied several different geographical regions (the European Arctic, Central Asia, and the western United States). We have drawn on available Ground Truth data in assessing the results of the various processing schemes. In all cases, we have benefited from the high-quality seismic arrays or networks available in these regions, and we have thus been able to evaluate the performance of array-based correlation processing under a variety of conditions. The main results of the project are summarized as follows: (1) Array-based waveform correlation has been demonstrated to lower significantly detection thresholds in comparison with standard single-channel waveform correlation. (2) Frequency-wavenumber analysis of the correlation traces on a small-aperture array provides an effective method for screening out a certain category of false alarms, and can therefore be used to improve detector sensitivity by lowering the threshold for automatic array detection. (3) We have developed and tested a framework for autonomous correlation detection. The framework comprises a set of conventional (STA/LTA) detectors on a collection of array beams, augmented by correlation and subspace detectors. The detectors are applied in parallel. (4) We have experimentally tested the processing of a large aftershock sequence using various transformations of the signals from the main event to construct what we denote an incoherent correlation detector or characteristic function correlation detector. (5) An important application of multi-channel waveform correlation is to identify instances of erroneous instrumental timing. We provide examples of detected timing errors on single channels of an array, as well as on a remote three-component station.

58 GEOSCIENCES↗

A Fast Radio Burst Backend for the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array is a radio interferometer array consisting of 16 six-meter dish antennas. The original digital backend integration time is at the seconds level, designed for H I intensity mapping experiment. A new digital backend with millisecond response is added to enable it to search for fast radio burst during its observations. The design and calibration of this backend, and the real time search pipeline for it are described in this paper. It is capable of forming 16 digital beams for each linear polarization, covering an area of 19.6 square degrees. The search pipeline is capable of searching for, recording and classifying FRBs automatically in real time. Finally, in commissioning, we succeeded in capturing the signal pulses from the pulsars PSR B0329+54 and B2021+51.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗