Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Fabrication of low blaze angle gratings by replication and plasma etch

We suggest a new method of making ultra-low blaze angle gratings for synchrotron application. The method is based on reduction of the blaze angle of a master grating by replication followed by a plasma etch. A master blazed grating with a relatively large blaze angle is fabricated by anisotropic wet etching of a Si single crystal substrate. The surface of the master grating is replicated by a polymer material on top of a quartz substrate by nanoimprinting and then transferred into quartz by a plasma etch. Then a 2nd nanoimprint step is applied to transfer the saw-tooth surface into a resist layer on top of a Si grating substrate. The plasma etch through the patterned resist layer provides transfer of the grooves into the Si substrate and results in reduction of the blaze angle due to the difference in etch rates of the resist and Si. We investigated the impact of the replication process on the groove shape, facet surface roughness, and diffraction efficiency of the fabricated 200 lines/mm low blaze angle grating.

Park, Sooyeon↗

TH-C-BRD-08: Reducing the Effect of Respiratory Motion On the Delivered Dose in Proton Therapy Through Proper Field Angle Selection

Purpose: This work investigated a novel planning strategy of selecting radiotherapy beam angles that minimizes the change in water equivalent thickness (dWET) during respiration in order to reduce the effects of respiratory motion in passively scattered proton therapy (PSPT). Methods: In a clinical trial treating locally-advanced lung cancer with proton therapy, 2–4 co-planar beams were previously selected by dosimetrists in the design of physician-approved PSPT treatment plans. The authors identified a cohort of patients in which respiratory motion affected the planned PSPT dose delivery. For this cohort, this work analyzed dWET during respiration over a 360 degree arc of potential treatment angles around the patient: the dWET was defined as the difference in WET between the full-exhale (T50) and full-inhale (T0) phases of the simulation 4DCT. New PSPT plans were redesigned by selecting new beam angles that demonstrated significant reduction in the value of dWET. Between the T50 and T0 phases, the root-mean-square deviation of dose and the change in dose-volume histogram curves (dAUC) for anatomical structures were calculated to compare the original to dWET reduction plans. Results: To date, three plans were retrospectively redesigned based on dWET analysis. In the dWET reduction plan, the root mean square dose (T50-T0) was reduced by 15–35% and the DVH dAUC values were reduced by more than 60%.The PSPT plans redesigned by selecting appropriate field angles to minimize dWET demonstrated less dosimetric variation due to respiration. Conclusion: We have introduced the use of a new metric to quantify respiratory motion in proton therapy: dWET. The use of dWET allows us to minimize the impact of respiratory motion of the entire anatomy in the beam path. This work is a proof of principle that dWET could suggest field angles in proton therapy that are more robust to the effects of respiratory motion.

60 APPLIED LIFE SCIENCES↗

SU-E-T-42: A Method to Determine the Optimal Proton Scanned Beam Angle to Ensure Robust Treatment Planning

Purpose: The ability of pencil beam scanning (PBS) to deliver highly conformal dose distributions may be affected by patient- and physics-related uncertainties. In clinical practice, selection of proton beam angles is determined qualitatively. This study investigates whether an optimal proton PBS beam angle could be quantitatively determined to ensure robust planning for pelvic targets. Methods: PBS beam angles were optimized based on two independent criteria; shortest and most homogeneous path from the patient surface to the distal edge of the target. The beam angle optimization criteria for gantry angles between 90°-270° were quantified in 10° increments for each ray, calculated as the straight line distance from the surface of the skin to the CTV’s distal edge. The goal was to minimize the path length of a proton PBS beam from the patient surface to the distal edge of the CTV, relative to the entry point, while minimizing HU inhomogeneity along the ray. HU homogeneity (i.e. HU variation) was quantitatively defined as the standard deviation of the average intra-ray HU intensity distribution of the rays comprising a single beam. This method was validated relative to inter-fraction changes on ten consecutive, locally advanced, rectal cancer patients, who underwent an average 4 verification CTs. The displacement of the 95–98% isodose lines was determined from forward calculated dose distributions on verification CTs. Results: The posterior beam (180°) had the average shortest path length, 132.7±17.2mm, and the most homogenous path, 31.9±4.3HU. The 95–98% isodose lines from all plans verified our path length to within 2.3±1.2% and HU homogeneity to within 1.2±0.5%. Conclusion: The proposed optimization algorithm determined the posterior beam dose distribution as the most robust relative to inter-fraction variation for large pelvic targets treated with PBS and was validated via verification CT for our patient cohort. Future work will focus on further algorithm development.

60 APPLIED LIFE SCIENCES↗

SU-F-T-161: The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality

Purpose: To investigate the effect of spot size variation as function of gantry angle on the quality of treatment plans for pencil beam scanning proton plans. Method: Three homogeneous 26×26×7cm dose volumes with different ranges and SOBPs were delivered on the matrixxPT 2D array at gantry angles of 0 and 270 degrees. The spot size sigma varies by 1.8, 7.8, and 1.4%, for nominal energies of 215, 183, and 103 MeV (Range 29, 22, and 8cm, respectively). The resulting dose planes are compared and evaluated with the gamma index for 2%/2mm and 1%/1mm criteria. Results: Patient specific QA is performed at a gantry angle of 0 degrees. However, beam sigmas vary as function of gantry angle because of the beam optics for each gantry. This will cause differences between the delivered and planned treatment plans. Delivered plans were compared and a gamma pass rate of 96.5% for criteria of 2%/2mm and 91.4% for 1%/1mm were seen for plans with a nominal energy of 183 MeV. For plans with a nominal energy of 103 MeV, gamma pass rates of 97.3% for 2%/2mm and 91.5% for 1%/1mm were seen. For plans with a nominal energy of 215 MeV the pass rate was 99.8% for 1%/1mm between the two gantry angles. Conclusion: Differences in beam sigma of up to 7.8% do not cause significant differences in the dose distribution of different spot size gammas.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Experimental study of coherent transition radiation from relativistic electrons in a dihedral angle

Angular intensity distributions for transition radiation excited by a beam of relativistic electrons in the emitter in the form of a dihedral angle are measured in the millimeter range. The angle is formed by the intersection of two conducting planes. The source of radiation is a microtron with an electron energy of 7.4 MeV. We analyze the effect of the magnitude of the dihedral angle of the emitter, the position of the electron transition point on the surface of the angle, and the direction of motion of electrons on the angular distribution of radiation intensity. It is shown that the spectral and angular distributions of radiation intensity in the dihedral angle substantially differ from analogous distributions for a particle intersecting a planar conducting surface. The possibility of using radiation to measure the energy, spatial position, and direction of motion of charges is considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peculiarities of the spectral-angular distribution of transition radiation from a relativistic particle in a dihedral angle

The spatial distributions of transition radiation from relativistic particles entering and exiting the edge of a dihedral angle formed by perfectly conducting flat surfaces have been investigated. The angular distributions of the radiation intensity in dihedral angles with various opening angles have been calculated. The angular distributions of forward radiation (when the particle exits the dihedral angle) and backward radiation (when the particle enters the dihedral angle) are shown to differ significantly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ESTIMATING LONG GRB JET OPENING ANGLES AND REST-FRAME ENERGETICS

We present a method to estimate the jet opening angles of long duration gamma-ray bursts (GRBs) using the prompt gamma-ray energetics and an inversion of the Ghirlanda relation, which is a correlation between the time-integrated peak energy of the GRB prompt spectrum and the collimation-corrected energy in gamma-rays. The derived jet opening angles using this method and detailed assumptions match well with the corresponding inferred jet opening angles obtained when a break in the afterglow is observed. Furthermore, using a model of the predicted long GRB redshift probability distribution observable by the Fermi Gamma-ray Burst Monitor (GBM), we estimate the probability distributions for the jet opening angle and rest-frame energetics for a large sample of GBM GRBs for which the redshifts have not been observed. Previous studies have only used a handful of GRBs to estimate these properties due to the paucity of observed afterglow jet breaks, spectroscopic redshifts, and comprehensive prompt gamma-ray observations, and we potentially expand the number of GRBs that can be used in this analysis by more than an order of magnitude. In this analysis, we also present an inferred distribution of jet breaks which indicates that a large fraction of jet breaks are not observable with current instrumentation and observing strategies. We present simple parameterizations for the jet angle, energetics, and jet break distributions so that they may be used in future studies.

79 ASTRONOMY AND ASTROPHYSICS↗

TILT ANGLE AND FOOTPOINT SEPARATION OF SMALL AND LARGE BIPOLAR SUNSPOT REGIONS OBSERVED WITH HMI

We investigate bipolar sunspot regions and how tilt angle and footpoint separation vary during emergence and decay. The Helioseismic and Magnetic Imager on board the Solar Dynamic Observatory collects data at a higher cadence than historical records and allows for a detailed analysis of regions over their lifetimes. We sample the umbral tilt angle, footpoint separation, and umbral area of 235 bipolar sunspot regions in Helioseismic and Magnetic Imager—Debrecen Data with an hourly cadence. We use the time when the umbral area peaks as time zero to distinguish between the emergence and decay periods of each region and we limit our analysis of tilt and separation behavior over time to within ±96 hr of time zero. Tilt angle evolution is distinctly different for regions with small (≈30 MSH), midsize (≈50 MSH), and large (≈110 MSH) maximum umbral areas, with 45 and 90 MSH being useful divisions for separating the groups. At the peak umbral area, we determine median tilt angles for small (7.°6), midsize (5.°9), and large (9.°3) regions. Within ±48 hr of the time of peak umbral area, large regions steadily increase in tilt angle, midsize regions are nearly constant, and small regions show evidence of negative tilt during emergence. A period of growth in footpoint separation occurs over a 72-hr period for all of the regions from roughly 40 to 70 Mm. The smallest bipoles (<9 MSH) are outliers in that they do not obey Joy's law and have a much smaller footpoint separation. We confirm the Muñoz-Jaramillo et al. results that the sunspots appear to be two distinct populations.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the Viewing Angle of GW170817 with Electromagnetic and Gravitational Waves

The joint detection of gravitational waves (GWs) and electromagnetic (EM) radiation from the binary neutron star merger GW170817 ushered in a new era of multi-messenger astronomy. Joint GW–EM observations can be used to measure the parameters of the binary with better precision than either observation alone. Here, we use joint GW–EM observations to measure the viewing angle of GW170817, the angle between the binary's angular momentum and the line of sight. We combine a direct measurement of the distance to the host galaxy of GW170817 (NGC 4993) of 40.7 ± 2.36 Mpc with the Laser Interferometer Gravitational-wave Observatory (LIGO)/Virgo GW data and find that the viewing angle is ${32}_{-13}^{+10}\,\pm 1.7$ degrees (90% confidence, statistical, and systematic errors). We place a conservative lower limit on the viewing angle of ≥13°, which is robust to the choice of prior. This measurement provides a constraint on models of the prompt γ-ray and radio/X-ray afterglow emission associated with the merger; for example, it is consistent with the off-axis viewing angle inferred for a structured jet model. Lastly, we provide for the first time the full posterior samples from Bayesian parameter estimation of LIGO/Virgo data to enable further analysis by the community.

79 ASTRONOMY AND ASTROPHYSICS↗

Discriminating electromagnetic radiation based on angle of incidence

The present invention provides systems, articles, and methods for discriminating electromagnetic radiation based upon the angle of incidence of the electromagnetic radiation. In some cases, the materials and systems described herein can be capable of inhibiting reflection of electromagnetic radiation (e.g., the materials and systems can be capable of transmitting and/or absorbing electromagnetic radiation) within a given range of angles of incidence at a first incident surface, while substantially reflecting electromagnetic radiation outside the range of angles of incidence at a second incident surface (which can be the same as or different from the first incident surface). A photonic material comprising a plurality of periodically occurring separate domains can be used, in some cases, to selectively transmit and/or selectively absorb one portion of incoming electromagnetic radiation while reflecting another portion of incoming electromagnetic radiation, based upon the angle of incidence. In some embodiments, one domain of the photonic material can include an isotropic dielectric function, while another domain of the photonic material can include an anisotropic dielectric function. In some instances, one domain of the photonic material can include an isotropic magnetic permeability, while another domain of the photonic material can include an anisotropic magnetic permeability. In some embodiments, non-photonic materials (e.g., materials with relatively large scale features) can be used to selectively absorb incoming electromagnetic radiation based on angle of incidence.

36 MATERIALS SCIENCE↗

Discriminating electromagnetic radiation based on angle of incidence

The present invention provides systems, articles, and methods for discriminating electromagnetic radiation based upon the angle of incidence of the electromagnetic radiation. In some cases, the materials and systems described herein can be capable of inhibiting reflection of electromagnetic radiation (e.g., the materials and systems can be capable of transmitting and/or absorbing electromagnetic radiation) within a given range of angles of incidence at a first incident surface, while substantially reflecting electromagnetic radiation outside the range of angles of incidence at a second incident surface (which can be the same as or different from the first incident surface). A photonic material comprising a plurality of periodically occurring separate domains can be used, in some cases, to selectively transmit and/or selectively absorb one portion of incoming electromagnetic radiation while reflecting another portion of incoming electromagnetic radiation, based upon the angle of incidence. In some embodiments, one domain of the photonic material can include an isotropic dielectric function, while another domain of the photonic material can include an anisotropic dielectric function. In some instances, one domain of the photonic material can include an isotropic magnetic permeability, while another domain of the photonic material can include an anisotropic magnetic permeability. In some embodiments, non-photonic materials (e.g., materials with relatively large scale features) can be used to selectively absorb incoming electromagnetic radiation based on angle of incidence.

Hamam, Rafif E.↗

Visualization of the flat electronic band in twisted bilayer graphene near the magic angle twist

Bilayer graphene was theorized to host a moire miniband with flat dispersion if the layers are stacked at specific twist angles known as the magic angles. Recently, such twisted bilayer graphene (tBLG) with the first magic angle twist was reported to exhibit correlated insulating state and superconductivity, where the presence of the flat miniband in the system is thought to be essential for the emergence of these ordered phases in the transport measurements. Tunneling spectroscopy and electronic compressibility measurements in tBLG have revealed a van Hove singularity that is consistent with the presence of the flat miniband. However, a direct observation of the flat dispersion in the momentum-space of such moire miniband in tBLG is still elusive. Here, we report the visualization of the flat moire miniband by using angle-resolved photoemission spectroscopy with nanoscale resolution (nanoARPES). The high spatial resolution in nanoARPES enabled the measurement of the local electronic structure of the tBLG. We clearly demonstrate the existence of the flat moire band near the charge neutrality for tBLG close to the magic angle at room temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlating inter-particle forces and particle shape to shear-induced aggregation/fragmentation and rheology for dilute anisotropic particle suspensions: A complementary study via capillary rheometry and in-situ small and ultra-small angle X-ray scattering

Predicting the stability of suspensions composed of anisotropic particles is difficult due to the complexity and interplay of hydrodynamic and colloidal forces. For example, it is not well understood how non-spherical particle shapes affect suspension-rheological responses. This study presents evidence showing how the stacking of boehmite platelets dispersed in aqueous solution leads to moderate shear thinning, even at low boehmite mass fractions. Wide angle X-ray, small angle X-ray, and ultra-small angle X-ray scattering were used to simultaneously monitor changes to the size and fractal dimensions of boehmite aggregates from 6 – 10,000 Å as the sample was recirculated through an in situ capillary rheometer. The latter also provided simultaneous measurements of the viscosity of the suspensions. Computational fluid dynamics modeling of the apparatus was used to provide a more rigorous analysis of the fluid flow. In addition to shear-induced aggregation/fragmentation correlated to a complicated balance between hydrodynamic and colloidal forces, the results indicate that orientationally-dependent interactions, arising from non-spherical boehmite aggregate sub-units, may explain the relatively large experimental viscosity when the hydrodynamic force is small compared to colloidal forces. Ultimately, the results from this study can provide a foundation for future work investigating particle shape effects on colloidal and hydrodynamics forces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phenomenological relations for quark and neutrino mixing angles

The most recent experimental data on quark and neutrino mixing angles are discussed. It is indicated that the results of the latest kaon-decay experiments are consistent with the unitarity condition for the first row of the Cabibbo-Kobayashi-Maskawa matrix if the currently available world-average value of the neutron lifetime is used to determine the element V{sub ud} of this matrix. The quark mixing angles are calculated within the Fritzsch-Scadron-Delbourgo-Rupp phenomenological approach on the basis of values of the masses of light and heavy constituent quarks. The neutrino mixing angles are calculated to a high precision with the aid of the hypothesis that the quark and neutrino mixing angles are complementary. The results are compatible with experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the bond-angle distribution in vitreous B{sub 2}O{sub 3} by {sup 11}B double rotation (DOR) NMR spectroscopy

The B-O-B bond angle distributions for both ring and non-ring boron sites in vitreous B{sub 2}O{sub 3} have been determined by {sup 11}B double rotation (DOR) NMR and multiple-quantum (MQ) DOR NMR. The [B{sub 3}O{sub 6}] boroxol rings are observed to have a mean internal B-O-B angle of 120.0+-0.7 deg. with a small standard deviation, sigma{sub R}=3.2+-0.4 deg., indicating that the rings are near-perfect planar, hexagonal structures. The rings are linked predominantly by non-ring [BO{sub 3}] units, which share oxygens with the boroxol ring, with a mean B{sub ring}-O-B{sub non-ring} angle of 135.1+-0.6 deg. and sigma{sub NR}=6.7+-0.4 deg. In addition, the fraction of boron atoms, f, which reside in the boroxol rings has been measured for this sample as f=0.73+-0.01. - Graphical abstract: Connectivities and B-O-B bond angle distributions of ring and non-ring boron atoms in v-B{sub 2}O{sub 3} have been determined by {sup 11}B double rotation (DOR) NMR, multiple-quantum (MQ) DOR NMR and spin-diffusion DOR. Near-perfect planar, hexagonal [B{sub 3}O{sub 6}] boroxol rings are shown to be present. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-resolution defect contrast in low angle annular dark-field STEM

While traditional high-resolution STEM is performed by exclusively collecting electrons which have been scattered to high angles (i.e., HAADF), the present contribution will focus on small-angle scattered electrons, as in low angle annular dark-field (LAADF) STEM. This unique imaging mode allows one to image defect contrast while maintaining directly interpretable atomic resolution. By simply adjusting the microscope camera length, and thus the acceptance angle of the annular detector, it is possible to transition between Z-contrast and defect contrast. Both LAADF and HAADF experimental and computational results are discussed in regards to zone axis imaging of a y/y1Ni-superalloy; various length scales are explored. Electron de-channeling is observed while the probe is placed over defected regions of crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CO 2 –Brine Contact Angle Measurements on Navajo, Nugget, Bentheimer, Bandera Brown, Berea, and Mt. Simon Sandstones

In this study, contact angles were measured for CO 2 bubbles on six different sandstones (Navajo, Nugget, Bentheimer, Bandera Brown, Berea, and Mt. Simon) that could potentially represent properties of CO 2 storage depositional environments. The impacts of pressure and temperature were studied by focusing on the CO 2 phase behavior in three different scenarios: gaseous, liquid, and supercritical conditions. Despite controlling the sample preparation and cleanliness, CO 2 -brine equilibration conditions, and pressure and temperature, there were inconsistencies in contact angle trends that could largely be attributed to natural sample heterogeneity resulting from localized variations in topography, surface roughness, and mineral composition across the surface. Despite these variations, the analysis of 298 measurements from this study showed that 81% of the contact angles were below 40° representing strongly water-wet to (moderately) water-wet behaviors. Also, 17.3% of the measurements were between 40° and 60° (weakly water-wet) and primarily belonged to small CO 2 bubbles (< 500 μm) that were heavily impacted by localized surface heterogeneity in natural sandstone samples. Additionally, only 1.7% of the measurements had angles greater than 60° and could be classified as CO 2 -wet behavior, but these measurements occurred on extremely small bubbles (100-200 μm) that were very dependent on localized surface heterogeneity. While some of the detailed physics of the CO 2 -brine-sandstone interface is still poorly understood, from an application standpoint, the sandstones of this study were best characterized as strongly water-wet to (moderately) water-wet.

03 NATURAL GAS↗